Voltammetry and polarography offer unparalleled sensitivity and selectivity, making them indispensable tools in analytical chemistry for trace-level analysis. Our application experts have compiled numerous documents on applications of voltammetry and polarography for different industries, such as plating and galvanics, electronics and semiconductors, or environmental monitoring.
Use the filters to search by analyte/parameter, sample matrix, norm, or industry.
- AN-SENS-001Quantification of paracetamol with square wave voltammetry
This Application Note demonstrates square wave voltammetry for sensitive, reproducible quantification of paracetamol using a screen-printed electrode and INTELLO.
- AN-SENS-002Phát hiện kim loại nặng bằng vôn-ampe xung vi phân
Bản ghi chú ứng dụng này trình bày DPV là phương pháp nhạy, có chọn lọc để phát hiện kim loại nặng trong nước, trình bày chi tiết về thiết lập, thông số và ưu điểm so với các kỹ thuật khác.
- AN-EC-034Ion-selective electrodes based on screen-printed technology
Advances in polymeric membranes and screen-printed technologies have enabled miniaturized, portable potentiometric sensors ideal for point-of-care analysis.
- AN-V-240Determination of total iodine in thyroid tablets with polarography
Accurate iodine determination in thyroid tablets, ensuring treatment efficacy, is achieved using the 884 Professional VA and Multi-Mode Electrode pro per USP guidelines.
- AN-V-200Determination of thiourea in copper electrorefining solutions
Thiourea measurement during copper electrorefining can be complicated by high chloride levels. Voltammetric analysis overcomes this issue, improving copper quality.
- AN-V-209Carbonyl test methods for alcohols
This polarographic method uses the Multi-Mode Electrode Pro for simultaneous detection of carbonyl impurities in alcohols, ensuring high product quality and stability.
- AN-V-199Voltammetric determination of gold(I) in gold plating baths
Controlling Au(I) levels in gold plating baths is required for high quality. Voltammetric analysis with the Multi-Mode Electrode Pro is an efficient solution.
- AN-PAN-1066Online analysis of cadmium in incineration plant wet gas scrubbers
Incineration flue gas requires treatment such as wet scrubbing. The 2060 VA Process Analyzer monitors heavy metals in the scrubbing water, ensuring compliance.
- AN-V-061Iron speciation in water with the Multi-Mode Electrode pro
Accurate determination of Fe(II) and Fe(III) in water is crucial for many industries. Cathodic sweeping voltammetry (CSV) offers a robust, cost-effective solution.
- AN-V-070Determination of iodide in glacial acetic acid
Iodide contamination in glacial acetic acid poses risks for downstream processes. Cathodic stripping voltammetry (CSV) at the HMDE offers reliable iodide measurement.
- AN-V-197Indirect determination of iodide in brine with stripping voltammetry
It is crucial to monitor iodide in NaCl brine to prevent membrane fouling during chlor-alkali electrolysis. Stripping voltammetry offers precise iodide analysis.
- AN-V-239Iron speciation in LiFePO4 batteries
Lithium iron phosphate batteries offer users safety and durability. Polarographic speciation evaluates Fe(II) and Fe(III) in cathode material, useful for several tests.
- AN-V-238Bismuth stabilizer in an electroless Ni plating bath
Electroless Ni plating offers superior surface finish and corrosion resistance. Anodic stripping voltammetry allows Bi stabilizer to be monitored in Ni plating baths.
- AN-V-237Lead stabilizer in an electroless Ni plating bath
Electroless nickel plating ensures low-cost wear and corrosion resistance. Monitoring lead stabilizer levels in Ni plating baths is possible with the Bi drop electrode.
- AN-V-236Antimony stabilizer in an electroless Ni bath
Monitoring Sb(III) stabilizer levels during electroless Ni plating is critical for high-quality coatings. Anodic stripping voltammetry offers fast, reliable Sb(III) analysis.
- WP-087Green alternative methods for voltammetric analysis in different water matrices
This White Paper presents four different «green» sensors: the scTRACE Gold, screen-printed electrodes, the glassy carbon electrode, and the Bi drop electrode from Metrohm that can be used to determine low concentrations of heavy metals in different sample matrices, such as boiler feed water, drinking water, and sea water.
- WP-085Improved antioxidant monitoring of in-service industrial lubricants
Voltammetry (VA) is a fast and established method for testing the remaining antioxidant content in industrial lubricants. The flexible and modular Metrohm VA system setup discussed in this White Paper delivers more repeatable and more reproducible results which fulfill all ASTM requirements. Additionally, users can automate the complete analysis process which makes it possible to run series of samples completely unattended.
- AN-EC-031Monitoring ferrocyanide oxidation using hyphenated EC-Raman
This Application Note highlights the use of Metrohm Hyphenated EC-Raman Solutions to monitor the reversible oxidation of ferrocyanide at a gold electrode.
- AN-EC-025Study of the hydrogen region at platinum electrodes with linear scan cyclic voltammetry
The study of the electrochemical behavior of platinum in acidic media is of crucial importance in fundamental electrochemistry and electrocatalysis. Most electrocatalytic processes occurring at Pt electrodes are highly sensitive to the structure of the platinum surface. Cyclic voltammetry (CV) is a widely used rapid measurement technique that provides both a qualitative and quantitative fingerprint of platinum surfaces. A comparison of results given by linear and staircase CVs is presented in this Application Note.
- AN-EC-027Measuring the potential at the counter electrode with VIONIC powered by INTELLO
Many different configurations are made possible when using two-, three-, or four-electrode cell setups in research. Depending on the experimental requirements, one setup may be preferred over another. Therefore, the proper electrode arrangements for these three situations are defined in this Application Note. As an example, the potential at the counter electrode is measured during the platinum oxidation in acidic media, with the second sense (S2) of VIONIC powered by INTELLO. Since dissolved Pt in solution could bias the results, it is important to be able to monitor the potential of the counter electrode.
- AN-EC-026Comparison between linear and staircase cyclic voltammetry on a commercial capacitor
Capacitors are electronic components necessary for the success of the electronics industry. They have also become essential components of both electric and hybrid vehicles. Electrochemical tests, such as potentiostatic cyclic voltammetry, are used to check the performance of capacitors. VIONIC powered by INTELLO can perform both staircase and linear cyclic voltammetries (CV). This Application Note gives a comparison between the linear and the staircase potentiostatic cyclic voltammetries and highlights the necessity of using the linear CV to best study the performance of capacitors.
- AN-EC-002Reference electrodes and their usage
A reference electrode has a stable and well-defined electrochemical potential (at constant temperature), against which the applied or measured potentials in an electrochemical cell are referred. A good reference electrode is therefore stable and non-polarizable. In other words, the potential of such an electrode will remain stable in the used environment and also upon the passage of a small current. This application note lists the most used reference electrodes, together with their range of use.
- AN-EC-015Metrohm 663 VA stand for Heavy Metal Ions detection in Water Sample
The determination of heavy metal ions in a solution is one of the most successful application of electrochemistry. In this application note, anodic stripping voltammetry is used to measure the presence of two analytes, in a sample of tap water.
- AN-V-210Total arsenic in mineral water
Arsenic is ubiquitous in the earth’s crust in low concentrations. Elevated levels can be found in mineral deposits and ores. Arsenic from such deposits leaches into the groundwater in the form of arsenite (AsO33–) and arsenate (AsO43–), causing its contamination. In addition to the arsenic originating from natural sources, industry and agriculture contribute to the contamination to a lower extent. The guideline value for inorganic total arsenic in the World Health Organization’s «Guidelines for Drinking-water Quality» is set to 10 μg/L. With a limit of detection (LOD) of 0.9 μg/L, anodic stripping voltammetry is a viable, less sophisticated alternative to atomic absorption spectroscopy (AAS) for the determination of arsenic. While AAS (and competing methods) can only be performed in a laboratory, anodic stripping voltammetry can be used conventionally in the laboratory or alternatively in the field using the 946 Portable VA Analyzer. The determination is carried out on the scTRACE Gold electrode.
- AN-V-218Bismuth in drinking water
Bismuth is considered as a metal with a very low toxicity. In high concentrations toxic effects have been described, however. There is no guideline value for bismuth in the World Health Organization’s «Guidelines for Drinking-water Quality» because typical levels usually found in drinking water are of no concern. Anodic stripping voltammetry is a viable, less sophisticated alternative to atomic absorption spectroscopy (AAS) for the determination of bismuth in drinking water. While AAS (and competing methods) can only be performed in a laboratory, anodic stripping voltammetry can be used in the laboratory or alternatively in the field with the 946 Portable VA Analyzer. The determination is carried out on the scTRACE Gold electrode.
- AN-V-232Nickel and cobalt in drinking water
EU legislation specifies 20 µg/L as the limit value for nickel in drinking water. The current provisional guideline value for Ni in the World Health Organization’s «Guidelines for Drinking-water Quality» is set to a maximum concentration of 70 µg/L. The adsorptive stripping voltammetry (AdSV) technique performed on the ex-situ bismuth film modified Metrohm DropSens 11L screen-printed electrode (SPE) can be used to simultaneously detect concentrations as low as 0.4 µg/L for nickel and 0.2 µg/L for cobalt with a 30 s deposition time. The disposable, maintenance-free sensor can be used conventionally in the laboratory with the 884 Professional VA, or alternatively in the field with the 946 Portable VA Analyzer. This method is best suited for manual systems.
- AN-V-222Iron determination in drinking water
The presence of iron in drinking water can lead to an unpleasant taste, stains, or even growth of «iron bacteria» that can clog plumbing and cause an offensive odor. Over a longer period, the formation of insoluble iron deposits is problematic in many industrial and agricultural applications. To avoid these problems, the U.S. Environmental Protection Agency (EPA) defines the Secondary Maximum Contaminant Level (SMCL) for water treatment and processing plants as 0.3 mg/L Fe in drinking water. The voltammetric determination of the iron triethanolamine complex on the non-toxic Bi drop electrode allows both the detection at very low levels (limit of detection of 0.005 mg/L) and measurements in a wide range of concentrations up to 0.5 mg/L.
- AN-V-214Lead in drinking water
Lead is known to be highly toxic to humans as it interferes with enzyme reactions. Chronic lead poisoning can be caused by lead leaching into drinking water from piping systems. The current provisional guideline value in the World Health Organization’s «Guidelines for Drinking-water Quality» sets a maximum concentration of 10 μg/L. With a limit of detection (LOD) of 0.2 μg/L, anodic stripping voltammetry is a viable, less sophisticated alternative to atomic absorption spectroscopy (AAS) to determine lead in drinking water. While AAS (and competing methods) can only be performed in a laboratory, anodic stripping voltammetry can be used conventionally in the laboratory or alternatively in the field with the 946 Portable VA Analyzer. The determination is carried out on a silver film applied to the scTRACE Gold electrode.
- AN-V-206Determination of selenite in electrolyte solutions for production of CIGS solar cells
This Application Note describes the polarographic determination of selenite in electroplating baths used in the production of copper indium gallium diselenide thin-film solar cells (CIGS cells). The CIGS absorber layer is electrodeposited on a molybdenum-coated substrate. Selenite analysis is carried out after dilution of the sample with sulfuric acid as supporting electrolyte.
- AN-V-198Aluminum in drinking water by adsorptive stripping voltammetry using alizarin red S (DASA) as complexing agent
Aluminum can be determined in drinking water by adsorptive stripping voltammetry at the HMDE using alizarin red S (DASA) as complexing agent. The method is linear up to 35 μg/L. The detection limit for this method is β(Al) = 1 μg/L, the limit of quantification is β(Al) = 3 μg/L. The sensitivity of the method cannot be increased by deposition.
- AN-V-190Mercury in polymer materials as part of electrotechnical products
The EU directive on «Restriction of Hazardous Substances» (RoHS) requires the testing of four regulatedheavy metals (Pb, Hg, Cd, Cr(VI)) in electrotechnical products. After sample preparation according to IEC62321 the determination of mercury in polymer materials can be carried out by anodic stripping voltammetry (ASV)at a gold rotating disk electrode (Au-RDE).
- AN-V-174Arsenic in zinc plant electrolyte
The concentration of As(total) in zinc plant electrolyte is determined by anodic stripping voltammetry (ASV) on a lateral gold electrode in HCl electrolyte. Due to the high excess of zinc in the sample the deposition potential has to be adapted. A second potential approx. 100 mV more negative than the arsenic signal has to be applied to selectively oxidize interfering antimony. For sample preparation the sample was passed through a cation exchange column to reduce the concentration of zinc in the measuring solution.
- AN-V-166Nickel in phosphatation bath
The concentration of Ni in a Zn phosphatation bath is determined by polarography in ammonia buffer pH 9.3.
- AN-V-158Indium in a tin bath
The concentration of In in a Sn bath is determined in a HCl / Urotropin® containing electrolyte by anodic stripping voltammetry (ASV). The determination is linear up to approx. 0.5 mg/L with respect to the concentration of In in the measuring vessel. The standard addition solution is also prepared with HCl and Urotropin®.
- AN-V-149Cobalt in sulfamate-nickel plating bath
The concentration of Co in a sulfamate Ni plating bath is determined by adsorptive stripping voltammetry (AdSV) inammonia buffer pH 9.6 with dimethylglyoxime (DMG) as complexing agent. All reagents have to be added in the order listed below. Special care has to be taken that the measuring solution is mixed well before the complexing agent is added. In case of precipitations of Ni-DMG further dilution of the sample is necessary.
- AN-V-124Iron(III) traces in standard solution with solochrome violet RS
The concentration of Fe(III) is determined by adsorptive stripping voltammetry with solochrome violet RS as complexing agent. All reagents have to be added in the order as listed below. Fe(II) does not show any signal. All reagents typically contain iron impurities. Therefore a subtraction of the reagent blank is recommended.
- AN-V-115Antimony in polyethylene terephthalate (PET)
Sb is determined in polyethylene terephthalate (PET) after digestion in sulfuric acid and hydrogen peroxide. The application is carried out with anodic stripping voltammetry (ASV) in hydrochloric acid.
- AN-V-107Tin in wastewater after UV digestion
Tin can be determined in wastewater by anodic stripping voltammetry (ASV) in oxalate buffer after addition of methylene blue. Samples with organic substances have to undergo UV digestion before analysis. Samples with higher concentrations of metals can be diluted before digestion.
- AN-V-098Molybdenum in sulfuric acid
Mo is determined by polarography at the SMDE in nitric acid solution.
- AN-V-089Mercury in wastewater
Mercury can be determined in wastewater by anodic stripping voltammetry (ASV) on a gold rotating disk electrode (Au RDE). After the addition of hydrochloric acid and hydrogen peroxide, digestion is done by UV irradiation.
- AN-V-080Germanium in lead
Germanium can be determined by adsorptive stripping voltammetry (AdSV) at the HMDE using acetate buffer as supporting electrolyte and catechol as complexing agent.
- AN-V-072NTA and EDTA in wastewater
NTA and EDTA can be determined as their bismuth complexes at the DME.
- AN-V-063Cyanide in gases resulting from the incineration of plastic insulating materials
Polarographic determination of cyanide in gases resulting from the incineration of plastic insulation materials after sample preparation.
- AN-V-055ß-Propiolactone in vaccine
Determination of ß-propiolactone in vaccine.
- AN-V-044Boron in human plasma using Beryllon III as a ligand
Voltammetric determination of boron in plasma using Beryllon III as a ligand [L. Thunus (1996), Anal. Chim. Acta 318: 303–308].
- AN-V-032Zinc, cadmium, lead, copper, iron, nickel, and cobalt in freeze-dried hops
Determination of Zn, Cd, Pb, Cu, Ni, Co, and Fe in freeze-dried hops after a wet digestion.
- AN-V-023Aluminum in an alkaline zinc oxide solution
Determination of Al in alkaline ZnO solution with Eriochrome Blue Black R at 60 °C.
- AN-V-009Cadmium, lead, and copper in brine and sodium hydroxide
Determination of Cd, Pb, and Cu in brine and NaOH.
- AN-V-228Thallium in drinking water
Presence of thallium in surface water is an indicator of industrial effluents and poses a serious health hazard if imbibed. Monitoring of thallium concentration can easily be done with anodic stripping voltammetry on the silver film modified scTRACE Gold. This non-toxic method allows the determination of thallium concentrations between 10–250 µg/L and can be carried out with the 946 Portable VA Analyzer.
- AN-V-224Nickel and cobalt in drinking water
Due to the toxicity and the detrimental effects of nickel and cobalt on human health, their concentrations in drinking water must be controlled. Therefore, EU the legislation specifies 20 µg/L as the limit value for nickel in drinking water. The current provisional guideline value for Ni in the World Health Organization’s «Guidelines for Drinking-water Quality» is set to a maximum concentration of 70 µg/L. To monitor the concentrations of Ni and Co with the 884 Professional VA, a method for simultaneous determination on the glassy carbon electrode (GC-RDE) modified with a Bi film is used.
- AN-V-220Remaining Useful Life of lubricants
Testing of in-service lubricating oils for their remaining antioxidant content is critical for capital equipment uptime as well as reducing running costs and repair expenses. Test methodologies such as RPVOT (rotating pressure vessel oxidation test) are time consuming and expensive to perform. Remaining Useful Life is a proven voltammetric method for testing the remaining active antioxidant content in minutes. Depending on the electrolyte, aromatic amine and phenolic antioxidants or hindered phenolic antioxidants can be determined. For the first time, a fully automated system is demonstrated, showing dramatically improved repeatability of data for confidence in reporting. Operator time is saved during sample preparation and irreproducible manual interpretation is eliminated via completely autonomous software processing. The user adds the sample into the vials, then the determination process of the sample series (including sample preparation and result calculations) is carried out automatically. The system is based on methods ASTM D6810, ASTM D6971, ASTM D7527, and ASTM D7590.
- AN-V-212Mercury in mineral water
Mercury and its compounds are toxic. The highest risk is posed by chronic poisoning with mercury compounds ingested with food. A significant part of the mercury present in the environment is of anthropogenic origin. Considerable sources are coal-fired power plants, steel, and nonferrous metal production, waste incineration plants, the chemical industry, or artisanal gold mining where the use of elemental mercury for the extraction of gold from the ore is still common. The guideline value for inorganic mercury in the World Health Organization’s «Guidelines for Drinking-water Quality» is set to 6 μg/L. With a limit of detection (LOD) of 0.5 μg/L, anodic stripping voltammetry is a viable, less sophisticated alternative to atomic absorption spectroscopy (AAS).While AAS (and competing methods) can only be performed in a laboratory, anodic stripping voltammetry can be used conventionally in the laboratory or alternatively in the field with the 946 Portable VA Analyzer. The determination is carried out on the scTRACE Gold electrode.
- AN-V-208Determination of thiourea in electrolytes for production of CIS and CIGS solar cells
This Application Note describes the polarographic determination of thiourea in electroplating baths used in the production of copper indium gallium diselenide (CIGS) or copper indium diselenide thin-film solar cells (CIS). Cadmium sulfide (CdS) from the electrolyte solution is deposited as a thin film on the CIS or CIGS absorber layer via chemical bath deposition (CBD).
- AN-V-204Determination of indium in electrolyte solutions for production of CIGS solar cells
This Application Note describes the polarographic determination of indium in electroplating baths used in the production of copper indium gallium diselenide thin-film solar cells (CIGS cells). The CIGS absorber layer is electrodeposited on the molybdenum-coated substrate. Indium analysis is carried out after dilution of the bath sample with sulfuric acid as supporting electrolyte.
- AN-V-196Antimony and bismuth in electroless nickel baths
Electroless nickel plating is an important and well established process in the surface finishing industry. In the past the addition of small amounts of lead has widely been used to stabilize the plating bath. With the increasing number of restrictions in recent years on the use of lead in consumber products, particularly electronics, alternative stabilizers were developed and introduced. Two of the stabilizers used as lead replacement are antimony and bismuth. They can be used as a single additive or in combination with each other or iodate. This method allows the determination of antimony and bismuth directly in the plating bath sample by anodic stripping voltammetry (ASV). The method is simple and fast, however sensitive and robust
- AN-V-192Chromium(VI) in chromate coating on metallic materials as part of electrotechnical products
The EU directive on «Restriction of Hazardous Substances» (RoHS) requires the testing of four regulated heavy metals (Pb, Hg, Cd, Cr(VI)) in electrotechnical products. After sample preparation according to IEC 62321 the determination of chromium(VI) in chromate coating on metallic materials can be carried out by adsorptive stripping voltammetry (AdSV) using DTPA (diethylenetriamine pentaacetic acid) as complexing agent.
- AN-V-188Cadmium and lead in polymer materials as part of electrotechnical products
The EU directive on «Restriction of Hazardous Substances» (RoHS) requires the testing of four regulated heavy metals (Pb, Hg, Cd, Cr(VI)) in electrotechnical products. After sample preparation according to IEC 62321 the determination of lead and cadmium in polymer materials can be carried out by anodic stripping voltammetry (ASV) using ammonium oxalate buffer pH 2.
- AN-V-180Nitrobenzene in aniline
The concentration of nitrobenzene in aniline is determined by polarography in an ethanol / acetic acid electrolyte.
- AN-V-176Total selenium in drinking water after reduction of Se(VI) to Se(IV) with the 909 UV Digester
The Se(IV) concentration can be determined by cathodic Stripping Voltammetry (CSV) in an ammonium sulfate electrolyte. The analysis also functions in the presence of Cu. Se(IV) is determined in the first step. In order to register the entire content of Se, Se(VI) species are first reduced to Se(IV). This is handled by the 909 UV Digester at a pH value of between 7 and 9. The method requires practically no reagents and permits selenium speciation.
- AN-V-172Cobalt in zinc plant electrolyte with a furildioxime as complexing agent
The concentration of Co in zinc plant electrolyte (neutral zinc sulfate solution) is determined by adsorptive stripping voltammetry (AdSV) in ammonia buffer with α-furildioxime as complexing agent.
- AN-V-168Lead in phosphatation bath
The concentration of Pb in a Zn phosphatation bath is determined by anodic stripping voltammetry (ASV) in HCl electrolyte.
- AN-V-164Titan in a titan pickle bath
The concentration of Ti in a Ti pickle bath is determined by polarography in an oxalic acid electrolyte.
- AN-V-160Palladium in an activator
The concentration of Pd in an activator bath is determined by polarography in ammonium chloride electrolyte.
- AN-V-151Antimony(III) and antimony(total) in electroless nickel bath
The concentration of Sb(III) and Sb(total) in an electroless nickel bath is determined by anodic stripping voltammetry (ASV). In c(HCl) = 0.6 mol/L only Sb(III) shows a signal. In w(HCl) = 10% the Sb(total) content is determined.
- AN-V-131Nickel and cobalt in sulfuric acid
The concentration of Ni and Co is determined by adsorptive stripping voltammetry at the HMDE with dimethylglyoxime (DMG) as complexing agent.
- AN-V-127Fe(II) in iron sucrose injection (USP)
Iron sucrose injection is a dark brown liquid which contains sucrose and iron(III) hydroxide in an aqueous solution, commonly used for the treatment of iron deficiency anemia. As a medical product, iron sucrose is subject to strict controls. Among other tests, the U.S. Pharmacopeia (USP) requires to monitor the limit of Fe(II) in the iron sucrose injection solution by polarography. The benefit of polarography is that Fe(II) and Fe(III) show signals at different potentials, and therefore an easier determination of Fe(II) without a previous separation of the two oxidation states is possible. The 884 Professional VA together with the viva software allows a straightforward determination of the Fe(II) content of iron sucrose injection solution following the requirements of the USP. The Fe(II) content is automatically calculated and stored in a database together with all relevant determination and calculation parameters.
- AN-V-122Iron (total) in deionized water (triethanolamine-bromate-method)
The concentration of Fe(total) is determined in deionized water. The method is suitable for iron concentrations down to the mid µg/L range. Electrochemical deposition is not applicable for this method. A subtraction of the reagent blank is recommended. Fe(II) and Fe(III) give signals with the same sensitivity.
- AN-V-117Iron in ethanol
Iron can be determined in ethanol by adsorptive stripping voltammetry (AdSV) at the HMDE. PIPES buffer is used as supporting electrolyte and catechol as complexing agent at a pH value of 7.0.
- AN-V-113Titanium in polyethylene terephthalate (PET)
Ti is determined in polyethylene terephthalate (PET) after digestion in sulfuric acid and hydrogen peroxide. Adsorptive stripping voltammetry (AdSV) with mandelic acid as complexing agent is used for this application.
- AN-V-109Selenium in wastewater after UV digestion
Selenium is determined by cathodic stripping voltammetry (CSV) at the hanging mercury drop electrode (HMDE). Se(IV) is deposited on the surface of the mercury drop in sulfuric acid electrolyte under addition of copper ions as Cu xSe y. Wastewater samples containing organic contaminants have to be digested by UV irradiation before analysis. In addition, the sample has to undergo a second irradiation step at pH 7−9 to reduce Se(VI) to Se(IV), since only Se(IV) is electrochemically active.
- AN-V-105Thallium in the presence of an excess of cadmium in zinc plant electrolytes (concentrated ZnSO4 solutions)
Thallium and cadmium can be determined by anodic stripping voltammetry (ASV) at the HMDE (Tl) and polarography at the DME (Cd), respectively using aqueous hydrochloric acid as supporting electrolyte. Since Cd is present in high excess and would therefore interfere with the determination of thallium, a post electrolysis procedure is applied to remove the co-deposited metal from the mercury drop.
- AN-V-100Nickel and cobalt in triphosphate
Ni and Co are determined in triphosphate by adsorptive stripping voltammetry (AdSV) in ammonia buffer at pH 9.5 with addition of dimethylglyoxime (DMG).
- AN-V-096Platinum in urine after UV digestion
Platinum in urine can be determined by adsorptive stripping voltammetry (AdSV) after UV digestion of the sample.
- AN-V-092Nickel in white wine after UV digestion
For the determination of nickel in white wine, UV digestion is required to mineralize the sample. The determination is done by adsorptive stripping voltammetry (AdSV) at the HMDE in ammonia buffer with dimethylglyoxime (DMG).
- AN-V-086Cadmium, lead, and copper in drinking water
Cd, Pb, and Cu can be determined in one run in acetate buffer by anodic stripping voltammetry (ASV).
- AN-V-082Different chromium species in sea water
Cr(III) forms an electrochemically active complex with diethylenetriaminepentaacetic acid (DTPA), so does Cr(VI) after in situ reduction on the surface of the HMDE. Depending on the sample preparation procedure and the waiting time after the addition of the complexing agent, the different chromium species can be differentiated: Total active chromium [total concentration of Cr(VI) and free Cr(III)]:The measurement is carried out immediately after the addition of DTPA. Cr(VI): Between the addition of DTPA and the start of the analysis a minimum waiting time of 30 min is necessary. During this waiting time the Cr(III)-DTPA complex becomes electrochemically inactive. Cr(III): The difference between the total active Cr and Cr(VI). Total chromium: Determination of total active Cr after UV digestion.
- AN-V-078Antimony in zinc solutions
The concentration of total Sb in zinc plant electrolytes is determined by anodic stripping voltammetry (ASV) in 5 mol/L HCl. If 0.6 mol/L HCl is used, only the concentration of antimony(III) is determined selectively. The interference of an excess of Cu is suppressed by the selective oxidation of Cu. Nevertheless, the concentration of Cu in the sample limits the amount of sample that can be used for the determination.
- AN-V-074Riboflavin in vitamin tablets
Riboflavin (vitamin B2) can be determined in vitamin preparations at the DME.
- AN-V-065Tungsten in the organic phase
Determination of W(VI) in the organic phase after digestion
- AN-V-057Thiomersal in eye drops
Thiomersal (also called thimerosal) is a mercury containing organic molecule that has been widely used as preservative for vaccines and eye drops. It is very effective, even in very low concentrations, against a wide range of microorganisms and viruses. To reduce the risk for consumers the maximum concentration of mercury in the products is limited by the authorities. Polarography or voltammetry can be used to accurately determine the concentration of thiomersal in vaccines or other cosmetic and pharmaceutical solutions (such as eye drops). The method is simple to perform, specific, and free of interferences.
- AN-V-053Artemisinin and artesunate in a standard sample
Determination of artemisinin and artesunate in a standard.
- AN-V-046Zinc, cadmium, lead, copper, nickel, and cobalt in vitamin tablets
Determination (after digestion) of zinc, cadmium, lead, copper, nickel, and cobalt in fabrication powder of vitamin tablets.
- AN-V-041Cadmium, lead, copper, nickel, and cobalt in soybean oil after digestion
Determination of Cd, Pb, Cu, Ni, and Co in soybean oil after extraction by boiling with HCl under reflux.
- AN-V-035Zinc, cadmium, lead, and copper in chili sauce after UV digestion
Determination of Zn, Cd, Pb, and Cu in chili sauce after digestion UV.
- AN-V-030Zinc, cadmium, lead, nickel, and cobalt in iron(III) chloride solution (40%)
Determination of Zn, Cd, Pb, Ni, and Co in FeCl3 solution of 40%.
- AN-V-026Iron and zinc in a nickel sulfate bath containing surfactants
Determination of Fe and Zn in a nickel sulfate bath containing surfactants after UV digestion.
- AN-V-019Lead in a nickel plating bath
Lead is commonly used as stabilizer in electroless nickel plating processes. The regular and precise determination of the electrochemically active Pb(II) concentration is essential to keep the plating process running optimally under stable conditions. Differential pulse anodic stripping voltammetry can be used to determine the active lead content after dilution. The voltammetric determination has been established as a straightforward, sensitive, selective, and interference-free method for this application.
- AN-V-015Nickel, antimony, cadmium, thallium, and copper in a neutral, highly concentrated zinc solution
Determination of Ni, Sb, Cd, Tl, and Cu in a neutral, highly concentrated zinc solution from the plating industry.
- AN-V-004Zinc, cadmium, lead, copper, and chromium in triglyceride
Determination of Zn, Cd, Pb, Cu, and Cr in triglyceride.
- AN-V-234Tellurium(IV) in drinking water
Tellurium is one of the elements recently identified as technologically critical for photovoltaic conversion, quantum dots, as well as in thermoelectric technology, and has the potential to become a new emergent contaminant. Until now there is no guideline value in the World Health Organization’s «Guidelines for Drinking-water Quality» and in the European Drinking Water Directive for tellurium(IV) concentration in drinking water. To monitor the tellurium(IV) levels in drinking water, anodic stripping voltammetry (ASV) performed on the unmodified scTRACE Gold is recommended. This method allows determination of tellurium(IV) in the concentration range between 1 µg/L and 60 µg/L when using a 90 s deposition time. The scTRACE Gold electrode does not need extensive maintenance such as mechanical polishing. Measurements can be performed in the laboratory with the 884 Professional VA or alternatively in the field with the 946 Portable VA Analyzer.
- AN-V-230Chromium(VI) in drinking water
The guideline value for total chromium in the World Health Organization’s (WHO) «Guidelines for Drinking-water Quality» is 50 µg/L. Chromium(VI) is more toxic than its trivalent form (Cr(III)) and is also less abundant. Therefore a robust and sensitive method is required to monitor its concentration in drinking water. The mercury film modified scTRACE Gold can be used to monitor chromium(VI), offering easy handling and a high grade of stability.
- AN-V-227Chromium(VI) in drinking water
The guideline value for chromium in the World Health Organization’s (WHO) «Guidelines for Drinking-water Quality» is 50 µg/L. It should be noted here that chromium concentrations are often expressed as total chromium and not as chromium(III) or (VI). Chromium(VI) is responsible for changes in genetic material, and is found in significantly lower concentrations than Cr(III). Therefore an extremely sensitive method is required to monitor Cr(VI) in drinking water. The powerful adsorptive stripping voltammetry (AdSV) technique on the ex-situ mercury film modified glassy carbon electrode using DTPA as complexing agent can be used to determine such low concentrations.
- AN-V-225Cadmium and lead in drinking water
To reduce the toxic effects of cadmium on the kidneys, skeleton, and the respiratory system, as well as the neurotoxic effects of lead, the provisional guideline values in the World Health Organization’s (WHO) «Guidelines for Drinking-water Quality» are set to a maximum concentration of 3 µg/L for cadmium and 10 µg/L for lead. The powerful anodic stripping voltammetry (ASV) technique on the ex-situ mercury film modified glassy carbon electrode is more than sufficient to monitor the proposed WHO guidelines for Cd and Pb in drinking water.
- AN-V-223Nickel and cobalt in drinking water
The main sources of nickel pollution are electroplating, metallurgical operations, or leaching from pipes and fittings. Catalysts for the petroleum and chemical industries are major application fields for cobalt. In both cases, the metal is either released directly, or via the waste water-river pathway into the drinking water system. Therefore in the EU the legislation specifies 20 µg/L as the limit value for the Ni concentration in drinking water. The simultaneous and straightforward determination of nickel and cobalt is based on adsorptive stripping voltammetry (AdSV). The unique properties of the non-toxic Bi drop electrode combined with AdSV results in an excellent performance in terms of sensitivity.
- AN-V-221Cadmium and lead in drinking water
To reduce the toxic effects of cadmium on the human body, as well as to limit the neurotoxic effects of lead, the provisional guideline values in the World Health Organization’s «Guidelines for Drinking-water Quality» are set to a maximum concentration of 3 µg/L for cadmium and 10 µg/L for lead. The completely mercury-free Bi drop electrode takes the next step towards converting voltammetric analysis into a non-toxic approach for heavy metal detection. Using this environmentally friendly sensor for anodic stripping voltammetry (ASV) allows the simultaneous determination of Cd and Pb in drinking water. The outstanding sensitivity is more than sufficient to monitor the provisional WHO guideline values.
- AN-V-219Sn(II) in radiopharmaceuticals
Sodium pertechnetate (99mTc) radiopharmaceuticals are widely used in medical imaging diagnostic procedures to help diagnose a large number of diseases affecting the bones and major organs. These radiopharmaceuticals are usually prepared from cold kits consisting of several ingredients, including a reducing agent. Sn(II) is a typical reducing agent which reduces the Tc(VII) that is added to the cold kit to a lower oxidation state which then forms the stable organic complex. For quality control, the tin content has to be determined in the kit vial. Sn(II) can be selectively determined using differential pulse polarography. Polarography is a straightforward, sensitive, selective, and interference-free method for the determination of mg/L levels of Sn(II) in radiopharmaceuticals.
- AN-V-217Nickel, cobalt in drinking water
Nickel is widely used in stainless steel production. At high enough concentrations, it is known to cause allergic reactions when in contact with skin. Drinking water may be contaminated by taps which are made from metals containing nickel. The guideline value for nickel in the World Health Organization’s «Guidelines for Drinking-water Quality» is set to 70 μg/L. National limit values of typically lower at e. g. 20 μg/L. Cobalt usually occurs associated with nickel and can be found in smaller concentrations besides nickel. Adsorptive stripping voltammetry is a viable, less sophisticated alternative to atomic absorption spectroscopy (AAS) for the determination of nickel and cobalt in drinking water. While AAS (and competing methods) can only be performed in a laboratory, adsorptive stripping voltammetric determinations can be used in the laboratory or alternatively in the field with the 946 Portable VA Analyzer. The determination is carried out on a bismuth film applied to the scTRACE Gold electrode.
- AN-V-213Copper in drinking water
Higher levels of copper in drinking water are usually caused by corrosive action of water leaching copper from copper pipes. While copper is an essential nutrient for the human organism, ingestion of higher concentrations have an adverse effect on human health. The current World Health Organization’s «Guidelines for Drinking-water Quality» recommend a maximum concentration of 2000 μg/L. With a limit of detection (LOD) of 0.5 μg/L, anodic stripping voltammetry is a viable, less sophisticated alternative to atomic absorption spectroscopy (AAS) for the determination of copper in drinking water. While AAS (and competing methods) can only be performed in a laboratory, anodic stripping voltammetry can be used conventionally in the laboratory or alternatively in the field with the 946 Portable VA Analyzer. The determination is carried out on the scTRACE Gold electrode.
- AN-V-211Arsenic(III) in mineral water
Arsenic is ubiquitous in the earth’s crust in low concentrations. Elevated levels can be found in mineral deposits and ores. Arsenic from such deposits leaches into the groundwater in the form of arsenite (AsO33–) and arsenate (AsO43–), causing its contamination. As(III) is more toxic than As(V) and shows higher mobility in the environment. The selective determination of this species is possible using the method described in this document. With a limit of detection (LOD) of 0.3 μg/L, anodic stripping voltammetry allows speciation, i.e. the specific determination of As(III). While atomic absorption spectroscopy (AAS) (and competing methods) can only determine the total element concentration, anodic stripping voltammetry is selective to the As(III) oxidation state. The determination is carried out on the scTRACE Gold electrode.
- AN-V-207Determination of cadmium in electrolyte solutions for production of CIS and CIGS solar cells
This Application Note describes the polarographic determination of cadmium in electroplating baths used in the production of copper indium gallium diselenide (CIGS) or copper indium diselenide thin-film solar cells (CIS). Cadmium sulfide (CdS) from the electrolyte solution is deposited as a thin film on the CIS or CIGS absorber layer via chemical bath deposition (CBD).
- AN-V-205Determination of gallium in electrolyte solutions for production of CIGS solar cells
This Application Note describes the determination of gallium in electroplating baths used in the production of copper indium gallium diselenide thin-film solar cells (CIGS cells). The CIGS absorber layer is electrodeposited on a molybdenum-coated substrate. Gallium analysis using anodic stripping voltammetry (ASV) is carried out after dilution of the sample with sulfuric acid as supporting electrolyte.
- AN-V-203Determination of copper in electrolyte solutions for production of CIGS solar cells
This Application Note describes the polarograhic determination of copper in electroplating baths used in the production of thin-film copper indium gallium diselenide solar cells (CIGS cells). The CIGS absorber layer is electrodeposited on a molybdenum-coated substrate. Copper analysis is carried out after dilution of the sample with sulfuric acid as supporting electrolyte.
- AN-V-201Nickel and cobalt in red wine after UV digestion
The determination of nickel and cobalt in red wine using adsorptive stripping voltammetry can be carried out after UV digestion of the sample.
- AN-V-195Iodate in electroless nickel baths
Electroless nickel plating is an important and well established process in the surface finishing industry. In the past, the addition of small amounts of lead has widely been used to stabilize the plating bath. With the increasing number of restrictions in recent years on the use of lead in consumber products, particularly electronics, alternative stabilizers were developed and introduced. One of the stabilizers used as lead replacement is iodate. It can be used as a single additive or in combination with bismuth or antimony. This method allows the determination of iodate directly in the plating bath sample by polarography. The method is simple and fast, however, sensitive and robust.
- AN-V-193Mercury in metallic materials as part of electrotechnical products
The EU directive on «Restriction of Hazardous Substances» (RoHS) requires the testing of four regulated heavy metals (Pb, Hg, Cd, Cr(VI)) in electrotechnical products. After sample preparation according to IEC 62321 the determination of mercury in metallic materials can be carried out by anodic stripping voltammetry (ASV) at a gold rotating disk electrode (Au-RDE).
- AN-V-191Cadmium and lead in metallic materials as part of electrotechnical products
The EU directive on «Restriction of Hazardous Substances» (RoHS) requires the testing of four regulated heavy metals (Pb, Hg, Cd, Cr(VI)) in electrotechnical products. After sample preparation according to IEC 62321 the determination of lead and cadmium in metallic materials can be carried out by anodic stripping voltammetry (ASV) using ammonium oxalate buffer pH 2.
- AN-V-189Chromium(VI) in polymer materials as part of electrotechnical products
The EU directive on «Restriction of Hazardous Substances» (RoHS) requires the testing of four regulated heavy metals (Pb, Hg, Cd, Cr(VI)) in electrotechnical products. After sample preparation according to IEC 62321 the determination of chromium(VI) in polymer materials can be carried out by polarography in ammonia buffer pH 9.6.
- AN-V-187Mercury in electronic components as part of electrotechnical products
The EU directive on «Restriction of Hazardous Substances» (RoHS) requires the testing of four regulated heavy metals (Pb, Hg, Cd, Cr(VI)) in electrotechnical products. After sample preparation according to IEC 62321 the determination of mercury in electronic components can be carried out by anodic stripping voltammetry (ASV) at a gold rotating disk electrode (Au-RDE).
- AN-V-185Cadmium and lead in electronic components as part of electrotechnical products
The EU directive on «Restriction of Hazardous Substances» (RoHS) requires the testing of four regulated heavy metals (Pb, Hg, Cd, Cr(VI)) in electrotechnical products. After sample preparation according to IEC 62321 the determination of lead and cadmium in electronic components can be carried out by anodic stripping voltammetry (ASV) using ammonium oxalate buffer pH 2.
- AN-V-181Chromium(VI) in cement
The concentration of Cr(VI) in cement is determined in tartrate electrolyte after acid extraction of the sample.
- AN-V-179Iron in boiler feed water
The iron concentration in boiler feed water has to be monitored to ensure reliable and safe operation of the water-steam circuit. Various guidelines set limits for the maximum iron content. The concentration of total iron in boiler feed water can be determined with high sensitivity using adsorptive stripping voltammetry (AdSV) using 2,3- dihydroxynaphthalene (DHN) as complexing agent. Voltammetry is a viable, less sophisticated alternative to atomic absorption spectroscopy (AAS) or inductive couple plasma (ICP) for the determination of iron with only a moderate investment in hardware required and low running costs.
- AN-V-177Iron in a chromium bath (triethanolamine-bromate-method)
The concentration of Fe(total) is determined by polarography in alkaline electrolyte containing triethanolamine (TEA) and KBrO3. All reagents typically contain Fe impurities. Therefore a subtraction of the reagent blank is recommended.
- AN-V-175Antimony(III) in zinc plant electrolyte with chloranilic acid as complexing agent
The concentration of of Sb(III) in zinc plant electrolyte is determined by adsorptive stripping voltammetry (AdSV) with chloranilic acid as complexing agent. In this method high copper concentrations do not interfere. An approx. 10-fold excess of lead interferes, since it shows a signal close to the antimony. With the parameters given below the working range of this method is 1 - 30 µg/L antimony(III) with respect to the concentration in the measuring vessel.
- AN-V-173Lead in zinc sulfate solution
The concentration of Pb in zinc sulfate solution is determined by anodic stripping voltammetry (ASV) in hydrochloric acid electrolyte.
- AN-V-171Tellurium in zinc plant electrolyte
The concentration of Te(IV) in Zn plant electrolyte is determined by cathodic stripping voltammetry (CSV) in ammonium sulfate electrolyte containing EDTA and Cu. To get a proper complexation of the interfering Zn a high amount of EDTA is necessary at pH 3.4.
- AN-V-169Lead in tin soldering contacts
The concentration of Pb in Sn soldering contacts is determined by anodic stripping voltammetry (ASV) in an electrolyte containing citrate, oxalic acid, HCl, and cetyl trimethyl ammonium bromide.
- AN-V-167Cadmium in phosphatation bath
The concentration of Cd in a Zn phosphatation bath is determined by polarography in HCl electrolyte.
- AN-V-165Zinc in phosphatation bath
The concentration of Zn in a zinc phosphatation bath is determined by polarography in ammonia buffer pH 9.3.
- AN-V-163Iron in degreasing bath
The concentration of Fe(total) is determined by polarography in an alkaline electrolyte containing triethanolamine (TEA) and KBrO3. All reagents typically contain iron impurities. Therefore a subtraction of the reagent blank is recommended.
- AN-V-161Copper in a cyanidic copper bath
The concentration of Cu in a cyanidic Cu bath is determined by polarography.
- AN-V-159Bismuth in a tin bath
The concentration of Bi in a Sn bath is determined in a HCl / Urotropin® containing electrolyte by anodic stripping voltammetry (ASV). A reaction time of at least 25 min is required before the determination is started. The standard addition solution is also prepared with HCl and Urotropin®.
- AN-V-150Copper in nickel plating bath
The concentration of Cu in a Ni plating bath is determined by polarography in chloride-containing acetate buffer at pH 4.7.
- AN-V-148Nickel in sulfamate-nickel plating bath
The concentration of Ni in a Ni plating bath is determined by polarography in ammonia buffer pH 9.6.
- AN-V-140Antimony (total) in acid copper bath
The concentration of Sb(total) in an acid Cu bath is determined by anodic stripping voltammetry using hydrochloric acid as electrolyte. Due to the excess of Cu the deposition potential has to be chosen only 50 mV more negative than the Sb signal
- AN-V-132Iron in sulfuric acid
The concentration of Fe is determined by adsorptive stripping voltammetry at the HMDE with 1-nitroso-2-naphthol (1N2N) as complexing agent.
- AN-V-130Aluminum in the ppb range in aqueous eluates of filter layers (Solochrome violet RS method)
The concentration of Al is determined by adsorptive stripping voltammetry at the HMDE. The method is suitable for Al in concentrations in the range of 0.1 ppb to approx. 40 ppb Al3+. Pb2+ ions do not interfere up to a concentration ratio Pb:Al = 10:1. Due to the slow complex formation of Al with solochrome violet RS the measuring solution was heated to 40 °C for 10 min prior to the determination. For standard addition a solution of Al with solochrome violet RS complex was used. All reagents have to be added in the order as listed below.
- AN-V-128Iron (total) in a chromium electroplating bath
The concentration of Fe(total) is determined polarographically in a chromium electroplating bath. The method is suitable for iron in concentrations in the ppm range. Fe(II) and Fe(III) show signals with the same sensitivity.
- AN-V-125Iron traces with 1-nitroso-2-naphthol
The concentration of Fe is determined in water samples by adsorptive stripping voltammetry with 1-nitroso-2-naphthol as complexing agent. All reagents have to be added in the order as listed below. All reagents typically contain iron impurities. Therefore a subtraction of the reagent blank is recommended. Fe(II) and Fe(III) show different sensitivities. Therefore the sample should only contain one of the iron species. Ascorbic acid (Vitamin C) can be added to the measuring solution and to the Fe(III) standard solution if both Fe(II) and Fe(III) are present in the sample to determine the concentration of total iron. A final concentration of ascorbic acid of 0.002 mol/L is suitable.
- AN-V-123Iron (total) in ethylene glycol with 2,3 dihydroxynaphthalene
The concentration of Fe(total) is determined in monoethylene glycol by adsorptive stripping voltammetry with 2,3-dihydroxy-naphthalene as complexing agent. The detection limit of the method is approx. 0.1 µg/L with respect to the content in the measuring vessel. If no bromate is added to the supporting electrolyte the sensitivity of the method is about 10 times lower. All reagents have to be added in the order as listed below. Fe(II) and Fe(III) give signals with the same sensitivity. All reagents typically contain iron impurities, especially the 2,3-dihydroxy-naphthalene. Therefore a subtraction of the reagent blank is recommended.
- AN-V-121Total iron in wastewater after UV digestion (Triethanolaminebromate method)
The concentration of Fe(total) is determined in wastewater after UV digestion. The method is suitable for iron concentrations down to the low μg/L range. Stripping voltammetry is not applicable for this method. Fe(II) and Fe(III) generate signals with identical sensitivity.
- AN-V-118Gold in ammonium thiosulfate solution
Gold can be determined by anodic stripping voltammetry (ASV) in the µg/l range at the Ultra Trace Graphite electrode. The solution should not contain halide ions.
- AN-V-116Zinc and lead in ethanol
Zn and Pb are determined by anodic stripping voltammetry (ASV) in acetate buffer at pH 4.6.
- AN-V-114Cobalt in polyethylene terephthalate (PET)
Co is determined in polyethylene terephthalate (PET) after digestion in sulfuric acid and hydrogen peroxide. The application is carried out with adsorptive stripping voltammetry (AdSV) in ammonia buffer with dimethylglyoxime (DMG) as complexing agent.
- AN-V-112Thiourea in nickel plating baths
Thiourea is determined by cathodic stripping voltammetry (CSV) at the HMDE in ammonia buffer at pH 8.9. Chloride in the sample does not interfere with this determination.
- AN-V-110Total chromium in wastewater after UV digestion (polarography method with ethylene diamine)
Cr(VI) is determined by polarography at the SMDE in acetate solution containing ethylene diamine to mask interfering copper ions. Only Cr(VI) is electrochemically active. It is for that reason that all chromium compounds must be present before the analysis as CR(VI), which is guaranteed by UV radiation with a pH > 4.
- AN-V-108Thallium in wastewater after UV digestion
Thallium in wastewater is determined in acetate buffer in presence of EDTA by anodic stripping voltammetry (ASV). Samples with organic substances have to undergo UV digestion before analysis.
- AN-V-106Nickel and cobalt in wastewater after UV digestion
Determination of nickel and cobalt in wastewater samples through adsorptive Stripping Voltammetry (AdSV). The wastewater samples first undergo a UV digestion in accordance with DIN 38406 Part 16.
- AN-V-104Formaldehyde in metalworking lubricants
Formaldehyde is determined polarographically at the DME in alkaline solution.
- AN-V-102Manganese in triphosphate
Anodic stripping voltammetry (ASV) at the HMDE is used to determine manganese in triphosphate. The sample is first digested and then measured in an alkaline solution.
- AN-V-099Cadmium, lead, and copper in triphosphate
Cadmium, lead, and copper are determined by anodic stripping voltammetry (ASV) at the HMDE using aqueous nitric acid as supporting electrolyte.
- AN-V-097Chromium in sulfuric acid
Cr(VI) is determined with the complexant DTPA at pH 6.2 by adsorptive stripping voltammetry (AdSV) at the HMDE.
- AN-V-095Quinine in bitter lemon
Quinine can be determined by polarography at the DME using Britton-Robinson buffer at pH = 7.0 as supporting electrolyte.
- AN-V-093Zinc, cadmium, lead, and copper in red wine after UV digestion
Zinc, cadmium, lead, and copper can be determined in red wine after UV digestion by anodic stripping voltammetry (ASV).
- AN-V-090Manganese in drinking water
Manganese in drinking water is determined by anodic stripping voltammetry (ASV) at the HMDE. The measurement is performed in an alkaline solution and zinc solution is added to prevent interference from intermetallic compounds.
- AN-V-087Nickel and cobalt in drinking water
Nickel and cobalt can be determined in drinking water in one run by adsorptive stripping voltammetry (AdSV). Dimethylglyoxime (DMG) is used as complexing agent at a pH value of 9.3.
- AN-V-085Elemental sulfur in gasoline
The concentration of elemental sulfur in gasoline is determined by polarography in acetate containing toluene/methanol electrolyte. The determination is linear up to 2 mg/L with respect to the concentration of elemental sulfur in the measuring vessel. Organic sulfur compounds are not detected with this method. The method is not suitable for diesel fuel, because diesel is not completely soluble in the electrolyte used. The gas wash bottle (6.2405.030) for inert gas supply has to be filled with supporting electrolyte.
- AN-V-083Zinc, cadmium, lead, and copper in wastewater after UV digestion
Zinc, cadmium, lead, and copper can be determined in wastewater samples after UV digestion by anodic stripping voltammetry (ASV) according to DIN 38406 part 16.
- AN-V-081Copper, iron, and vanadium in sodium chloride
Copper, iron, and vanadium can be determined in salt samples in the µg/kg concentration range by adsorptive stripping voltammetry (AdSV) at the HMDE. No sample preparation is necessary.
- AN-V-079Germanium in electroplating baths
Germanium can be determined by adsorptive stripping voltammetry (AdSV) at the HMDE using acetate buffer as supporting electrolyte and catechol as complexing agent.
- AN-V-077Nickel and cobalt in zinc plant electrolytes (concentrated zinc sulfate solutions)
Nickel can be determined in concentrated zinc solutions by adsorptive stripping voltammetry (AdSV) at the HMDE using ammonia buffer as supporting electrolyte and dimethylglyoxime (DMG) as complexing agent. The determination of cobalt does not work under these conditions as the very high Zn2+ concentration interferes with the Co signal. Therefore, an alternative complexing agent has to be used: α-benzil dioxime in ammonia buffer under addition of sodium nitrite.
- AN-V-075Nicotinamide in vitamin tablets
Nicotinamide (vitamin B3, vitamin PP) can be determined in vitamin preparations at the DME.
- AN-V-073Ascorbic acid in orange juice
Ascorbic acid (vitamin C) can be determined in fruit and vegetable juices at the DME without sample preparation.
- AN-V-071Rhodium and platinum in drinking water
Rhodium and platinum can be determined in water samples after UV digestion and complexation by adsorptive stripping voltammetry (AdSV) at the HMDE.
- AN-V-069Nickel and cobalt in seawater
Nickel and cobalt can be determined in seawater by adsorptive stripping voltammetry (AdSV) at the HMDE.
- AN-V-064Free styrene in polystyrene and mixed polymers
Determination of styrene monomers in polystyrene. Free styrene is converted to a polarographically active pseudonitrosite.
- AN-V-0624-Carboxybenzaldehyde in polyterephthalic acid
4-Carboxybenzaldehyde can be reduced directly on the DME in a solution containing ammonium.
- AN-V-060Cysteine and cystine in caseinate
Determination of cysteine and cystine in caseinate after sample preparation with NaOH.
- AN-V-058Cysteine and cystine in an infusion solution
Determination of cysteine and cystine in an infusion solution.
- AN-V-056Ascorbic acid in vitamin capsules
Determination of ascorbic acid (vitamin C) in vitamin capsules after sample digestion.
- AN-V-054Palladium in pharmaceutical products
The concentration of Pd in pharmaceutical products is determined by polarography after wet digestion.
- AN-V-051Cadmium and lead in a herbicide
Determination of cadmium and lead in herbicide powder containing 37% copper after digestion.
- AN-V-047Manganese, iron, and molybdenum in vitamin tablets
Determination of manganese, iron, and molybdenum (after digestion) in fabrication powder of vitamin tablets.
- AN-V-045Uranium in drinking water
Uranium can be determined in drinking water by adsorptive stripping voltammetry (AdSV) at the hanging mercury drop electrode (HMDE). Chloranilic acid is used as complexing agent.
- AN-V-043Zinc in a herbal pharmaceutical drug against prostate cancer
Determination of zinc in a herbal pharmaceutical drug against cancer of the prostate.
- AN-V-039Zinc, cadmium, lead, and copper in whiskey after UV digestion
Determination of Zn, Cd, Pb, and Cu in whiskey after UV digestion.
- AN-V-036Mercury in chili sauce after UV digestion
Determination of Hg in chili sauce after UV digestion.
- AN-V-033Zinc, lead, copper, and iron in sugar
Determination of Zn, Pb, Cu, and Fe in sugar after wet digestion.
- AN-V-031Coumarin and tartrazine in vodka
Determination of coumarin and tartrazine in vodka.
- AN-V-029Zinc, cadmium, lead, nickel, and cobalt in Javelle water
Determination of Zn, Cd, Pb, Ni, and Co in Javelle water.
- AN-V-027Copper in a nickel sulfate bath containing surfactants
Determination of Cu in a nickel sulfate bath containing surfactants after UV digestion.
- AN-V-024Copper and chromium in an etching bath
Determination of Cu and Cr in an etching bath. Due to the high concentrations of Mn and Ni, Cu is determined as the EDTA complex and Mn as DTPA complex.
- AN-V-022Antimony and bismuth in an alkaline zinc oxide solution in one run
Simultaneous determination of Sb and Bi in an alkaline ZnO solution.
- AN-V-018Tin and lead in an organo plating bath
Determination of Sn and Pb in an organo plating bath.
- AN-V-016Nickel, iron, and copper in a silver plating bath
Determination of Ni, Fe, and Cu in a silver plating bath.
- AN-V-010Zinc, cadmium, lead, copper, iron, nickel, and cobalt in NaOH in one run
Simultaneous determination of Zn, Cd, Pb, Cu, Fe, Ni, and Co in 50% NaOH.
- AN-V-006Cadmium, lead, and antimony in acetic acid
Determination of Cd, Pb, and Sb in acetic acid.
- AN-V-003Nickel, cobalt, and iron in polyterephthalic acid solution
Determination of Ni, Co, and Fe in a PTA solution containing HCl.
- AN-V-001Iron, cadmium, lead, and copper in cobalt acetate solution
Determination of Fe, Pb, Cd, and Cu in Co(Ac)2 solution using the MME.
- AN-V-233Selenium(IV) in drinking water
The difference between the toxic and essential levels of selenium to human health are very slight. Therefore, the current provisional guideline value for selenium(IV) in the World Health Organization’s «Guidelines for Drinking-water Quality» and in the European Drinking Water Directive is set to a maximum concentration of 10 µg/L. The anodic stripping voltammetric (ASV) technique performed on the unmodified scTRACE Gold can be used to determine concentrations as low as 0.5 µg/L selenium with a 30 s deposition time. These limits can be lowered even further by increasing the deposition time. The linear range at 30 s deposition time ends at approximately 100 μg/L. The scTRACE Gold electrode does not need extensive maintenance such as mechanical polishing. Measurements can be performed in the laboratory with the 884 Professional VA or alternatively in the field with the 946 Portable VA Analyzer. This method is suited for manual or automated systems.
- AN-V-231Cadmium and lead in drinking water
The provisional guideline values in the World Health Organization’s (WHO) «Guidelines for Drinking-water Quality» are set to 3 µg/L for cadmium and 10 µg/L for lead. The anodic stripping voltammetry (ASV) technique performed on the ex-situ mercury film modified Metrohm DropSens screen-printed electrode (SPE) can be used to simultaneously detect concentrations as low as 0.3 µg/L for both elements. This is suitable to monitor the WHO guideline values. The main advantage of this method lies in the innovative and cost-effective screen-printed electrode.
- AN-V-229Antimony(III) in drinking water
The toxicity of antimony depends on its oxidation state: antimony(III) is more toxic than antimony(V). Due to its carcinogenicity, EU legislation specifies 5 µg/L and the World Health Organization (WHO) sets a maximum concentration of 20 µg/L as the Sb(III) limit value in drinking water. Straightforward determination using anodic stripping voltammetry provides a fast (analysis time under 10 minutes) and an ultra-sensitive tool for monitoring the antimony(III) concentration in drinking water. Measurements can be performed in the laboratory with the 884 Professional VA, or alternatively in the field with the 946 Portable VA Analyzer.
- AN-V-186Chromium(VI) in electronic components as part of electrotechnical products
The EU directive on «Restriction of Hazardous Substances» (RoHS) requires the testing of four regulated heavy metals (Pb, Hg, Cd, Cr(VI)) in electrotechnical products. After sample preparation according to IEC 62321 the determination of chromium(VI) in electronic components can be carried out by polarography in ammonia buffer pH 9.6.
- AN-V-178Copper in seawater with the Mercury Film Electrode (MFE)
The concentration of Cu in seawater is determined by anodic stripping voltammetry (ASV) in acetate buffer on a mercury film electrode (MFE). Gallium is added to overcome zinc interferences.
- AN-V-170Selenium in zinc plant electrolyte
The concentration of Se(IV) in zinc plant electrolyte is determined by cathodic stripping voltammetry (CSV) in ammonium sulfate electrolyte containing EDTA and Cu. The Cu concentration has to be adapted to the sample and the deposition time. With voltammetry only free selenium is determined, therefore it has to be taken into consideration that selenium forms sparingly soluble compounds with numerous cations (e.g. Fe2(SeO3 )3 with Ks = 2·10-31).
- AN-V-162Iron in deoxidation solution (oxalate method)
The concentration of Fe(total) is determined by polarography in oxalate buffer pH 2. This method is suitable for iron concentrations in the mg/L range.
- AN-V-154NTA in cyanidic gold bath
NTA in a cyanidic gold bath is determined as Bi-NTA complex by polarography. For standard addition a Bi-NTA standard solution is used.
- AN-V-129Iron (total) in phosphoric acid
The concentration of Fe is determined polarographically in phosphoric acid. The method is suitable for iron in concentrations in the ppm range. Fe(II) and Fe(III) show signals with the same sensitivity
- AN-V-120Nickel in ethylene glycol after UV digestion
The concentration of nickel in ethylene glycol can be determined by adsorptive stripping voltammetry (AdSV) after the organic matrix is destroyed by UV digestion.
- AN-V-111Germanium in zinc plant electrolytes (concentrated ZnSO4 solutions)
Germanium is determined by adsorptive stripping voltammetry (AdSV) at the HMDE using aqueous sulfuric acid as supporting electrolyte and pyrocatechol violet as complexing agent. It is possible to determine 20 µg/L Ge in a sample containing 150 g/L Zn, 3 g/L Cd and 1 mg/L Pb.
- AN-V-103Chromium in lime (CaCO3)
Cr(VI) is determined at the HMDE in an electrolyte containing ethylenediamine and acetate. Because Cr(III) is electrochemically inactive, all Cr has to be oxidised prior to analysis.
- AN-V-094Platinum and rhodium in red wine after UV digestion
For the determination of heavy metals in wine, UV digestion is required to mineralize the sample. The determination of platinum and rhodium is carried out with adsorptive stripping voltammetry (AdSV) at the HMDE.
- AN-V-084Total chromium in wastewater after UV digestion (DTPA method)
Total chromium can be determined in wastewater samples. UV digestion is necessary to remove interfering organic matter before the analysis. Complete oxidation of Cr(III) to Cr(VI) is guaranteed by an additional UV irradiation step at pH > 4.
- AN-V-076Cobalt in gold plating baths
Cobalt can be determined in the presence of high concentrations of gold at the DME using 5-sulfosalicylic acid as supporting electrolyte and DMG as complexing agent.
- AN-V-068Cadmium and lead in seawater
Cd and Pb can be determined in seawater samples in the ng/L concentration range by anodic stripping voltammetry on a mercury film electrode (MFE).
- AN-V-0591-Methyl-nicotinamide hydrochloride in a standard solution
Determination of 1-methyl-nicotinamide hydrochloride in a standard using Na2CO3 as electrolyte.
- AN-V-048Clotiapine in a standard sample
Determination of clothiapine in a pharmaceutical standard.
- AN-V-038Aluminum in albumin lyophilizate after digestion
Determination of aluminum with Eriochrome Blue Black R at 60 °C in albumin lyophilizate after a wet digestion.
- AN-V-028Zinc, cadmium, lead, nickel, and cobalt in hydrochloric acid
Determination of Zn, Cd, Pb, Ni, and Co in hydrochloric acid (37.8%).
- AN-V-017Chromium and selenium in a silver plating bath
Determination of Cr and Se in a silver plating bath.
- AN-V-002Chromium, manganese, and titanium in polyterephthalic acid solution
Determination of Cr, Mn, and Ti in a PTA solution containing HCl.