Søg
DRP-FLWCL
Flow Cell for Screen-Printed ElectrodesMethacrylate wall-jet Flow-Cell for FIA. Suitable to be used with standard format Screen-Printed Electrodes with the electrochemical cell in the middle of the strip. Closing system with powerful magnets Fittings included.
DRP-CFLWCL-WE
Flow Cell - Only Working ElectrodeMethacrylate wall-jet Flow-Cell for FIA.Its o-ring entraps only the working electrode. Suitable to be used with standard Screen-Printed Electrodes with the electrochemical cell in the center of the strip. Closing system with powerful magnets. Fittings included.
DRP-FLWCL-IDE
Flow Cell for Interdigitated ElectrodesMethacrylate wall-jet Flow-Cell for FIA. Suitable to be used with IDE electrodes ref. G-IDEAU10, G-IDEAU5, G-IDEPT10, G-IDEPT5, G-IDECONAU10 and G-IDECONPT10. Closing system with powerful magnets. Fittings included.
DRP-FLWCL-PEEK
Flow Cell in PEEK for Screen-Printed ElectrodesPEEK wall-jet Flow-Cell for FIA. Suitable to be used with standard format Screen-Printed Electrodes with the electrochemical cell in the middle of the strip. Closing system with powerful magnets. Fittings included.
DRP-FLWCL-P
Flow Cell in Polypropylene for Screen-Printed ElectrodesPolypropylene wall-jet Flow-Cell for FIA. Suitable to be used with standard format Screen-Printed Electrodes with the electrochemical cell in the middle of the strip. Closing system with powerful magnets. Fittings included.
DRP-FLWCL-SC
Flow Cell with screws for Screen-Printed ElectrodesMethacrylate (top part) wall-jet Flow-Cell for FIA. Suitable to be used with standard format Screen-Printed Electrodes with the electrochemical cell in the middle of the strip. Closing system with screws. Fittings included.
DRP-FLWCL-WS
Flow Cell for Work in Solution Screen-Printed ElectrodesMethacrylate wall-jet Flow-Cell for FIA. Suitable to be used with work in solution format Screen-Printed Electrodes with the electrochemical cell at the end of the strip. Closing system with powerful magnets. Fittings included.
DRP-CFLWCL-MAGN
Flow Cell for magnetic assays with Screen-Printed ElectrodesMethacrylate wall-jet Flow-Cell associated with a powered magnet designed to do FIA with magnetic beads. Suitable to be used with standard format Screen-Printed Electrodes with the electrochemical cell in the middle of the strip. Fittings included.
DRP-FLWCL8X
Flow Cell for 8X format Screen-Printed ElectrodesMethacrylate wall-jet Flow-Cell for performing simultaneus measuements in FIA. Suitable to be used with 8X format Screen-Printed Electrodes. Closing system with screws. Fittings included.
DRP-FLWCL8X1C
Flow Cell for 8X format Screen-Printed Electrodes 1 ChannelMethacrylate thin-layer Flow-Cell for performing simultaneus measuements in FIA. Suitable to be used with 8X format Screen-Printed Electrodes. Closing system with screws. Fittings included.
003RDX
Spectro-electrochemical flow cell setup with reduced optical pathThis is a horizontally mounted, multi-purpose spectroelectrochemical cell with 4 mm long optical path (i.e. electrolyte thickness) designed to be used with standard UV-Vis or IR spectrometers. It enables obtaining electrochemical and spectroscopic information from liquid sample or thin film in systems where variations in applied potential induce changes in observed spectra.It consists of a polyether ether ketone (PEEK) flow chamber equipped with magnetic mount sample holder (a screw version is available on request), screw mount quartz window holder and two different mini tripods. It well fits aqueous (EPDM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements.Unlike Spectro-EFC 1.75 mL, this cell is meant to be used with pseudo-reference electrode (50 mm long) and counter electrode in the form of a metal wire (90 mm long), both with plug of 6 mm in diameter. Thanks to the application of pseudo-reference electrode, the thickness of an electrolyte is reduced from 12 mm down to 4 mm. Please note: this product is not available from Metrohm Germany.
6.07401.100
Holder OMNIS NIR, flow-through cellsCuvette holder for the OMNIS NIR Analyzer for flow-through cells(6.7401.300; 6.7401.310; 6.7401.320; 6.7401.330; 6.7401.340).
6.7401.310
Flow-through cell, 1 mmFlow quartz cuvettes with an optical path length of 1.0 mm suitable for near-infrared spectroscopy (NIRS) analyses.Compatible with:Holder OMNIS NIR, flow-through cell (6.07401.100); DS2500 holder for flow cells (6.7493.000) ;
6.7401.300
Flow-through cell, 0.5 mmFlow quartz cuvettes with quartz glass window and an optical path length of 0.5 mm suitable for near-infrared spectroscopy (NIRS) analyses.Compatible with:Holder OMNIS NIR, flow-through cell (6.070401.100); DS2500 holder for flow cells (6.7493.000);
6.7493.000
DS2500 Holder Flow CellIntelligent holder for 12.5 mm flow cells
607510910
Raman Flow CellStainless steel flow cell for Raman lab-grade probes. Compatible with 1/8'' Swagelok and Parker A-lok connection fittings.
6.07401.320
Flow-through cell, 2 mmFlow quartz cuvettes with an optical path length of 2.0 mm suitable for near-infrared spectroscopy (NIRS) analyses.Compatible with:Holder OMNIS NIR, flow-through cell (6.070401.100);
DRP-TLFCELL
Thin-layer flow electrochemical cellThin film flow cell for use with ceramic SPEs with the detection zone in the center of the strip. It allows the study of different parameters under flow conditions.
6.2763.000
Flow-through cell for the 6.0915.100/6.0920.100Flow-through cell for the 6.0915.100/6.0920.100 5-ring conductivity measuring cell
6.2839.130
Flow-through cell for 944PEEK flow-through cell for 944 Professional UV/VIS Detector Vario
6.2839.131
Flow-through cell for 947PEEK flow-through cell for 947 Professional UV/VIS Detector Vario
BWT-840000117
Raman Flow Cell (BAC160-SS)Raman flow-through cell made of stainless steel, for inline Raman measurements of liquid samples by interfacing with standard laboratory probe (9.5 mm diameter; probe is not included in scope of delivery).
6.07401.330
Flow-through cell, 2.5 and 5 mmFlow quartz cuvettes with quartz glass window and two optical path lengths (2.5 mm or 5.0 mm) suitable for near-infrared spectroscopy (NIRS) analyses.Compatible with:Holder OMNIS NIR, flow-through cell (6.070401.100)
6.07401.340
Flow-through cell, 5 and 10 mmFlow quartz cuvettes with quartz glass window and two optical path lengths (5.0 mm or 10.0 mm) suitable for near-infrared spectroscopy (NIRS) analyses.Compatible with:Holder OMNIS NIR, flow-through cell (6.070401.100);
6.07401.140
FEP tubing M6, 0.70 m, flow-through cellConnection tubing with connectors for flow-through cells and the OMNIS cylinder unit.
6.07401.150
FEP tubing M6, 1.20 m, flow-through cellConnection tubing with connectors for flow-through cells and the OMNIS cylinder unit.
DRP-TLFCL-REFLECELL
Spectroelectrochemical Reflection Cell for Thin-Layer Flow-Cell Screen-Printed ElectrodesCell for performing spectroelectrochemical measurements in flow conditions in combination with the TLFCL-CIR format Screen-Printed Electrodes, the suitable fittings and ref. RPROBE-VIS-UV.
6.07401.160
FEP aspiration tubing M6, 1.40 m, flow-through cellTubing with connector for flow-through cells and tapering for simple threading into the titration heads of the OMNIS Sample Robot.
DRP-TLFCL-HOLDER
Holder for Thin-Layer Flow-Cell integrated Screen-Printed ElectrodesHolder for Thin-Layer Flow-Cell integrated Screen-Printed Electrodes
002RDX
Gas Diffusion Electrode X-Ray diffraction electrochemical flow cell setupThis is a horizontally mounted, multi-purpose electrochemical cell for Gas Diffusion Electrode (GDE), designed to be used with X-Ray Diffractometry.The cell consists of two individual compartments: the liquid flow chamber and the gas chamber, which are placed on opposing faces of a GDE. Both compartments are held in place by magnetic/screw mount, providing a leakage-free O-Ring seal.The liquid chamber can be filled with an electrolyte using a syringe or an electrolyte can continuously flow through it using an external reservoir and peristaltic pump (reservoir and pump not included).The dry chamber is gas-tight enabling continuous flow of a gas carrier and evacuation of the gas products for sampling using standard analytical instruments such as a residual gas analyzer. Both compartments are made of a polyether ether ketone (PEEK) material. The cell is meant to be used with standard reference electrode having 6 mm in diameter and counter electrode in the form of a rod/helix with 6 mm in diameter and 15 mm active.Please note: this product is not available from Metrohm Germany.
DRP-CAC-TLFCL
Cable connector for Thin-Layer Flow-Cell integrated Screen-Printed ElectrodesConnects DropSens Thin-Layer Flow-Cell integrated Screen-Printed Electrodes with any kind of potentiostat
001RDX
Optical fiber spectro-electrochemical flow cell setupThis is a horizontally mounted, multi-purpose spectroelectrochemical cell designed to be coupled with light sources and spectrometers (UV-Vis, NIR, IR) via optical fibers. It enables obtaining electrochemical and spectroscopic information from liquid sample or thin films in systems where variations in applied potential induce changes in observed spectra.Applied collimating lenses are curved optical lenses that enables parallel irradiation of the sample. Each lens is 5 mm in diameter, has focal length of 10 mm and wavelength range of 200-2000 nm. The cell consists of a polyether ether ketone (PEEK) flow chamber equipped with magnetic mount sample holder (a screw version is available on request), screw mount quartz window holder and two different mini tripods.The cell is meant to be used with standard reference electrode having 6 mm in diameter and counter electrode either in the form of a rod or helix with 6 mm in diameter and 15 mm active length.Please note: this product is not available from Metrohm Germany.
DRP-TLFCLRAMANCELL
Raman flow-cell for Thin-layer flow-cell integrated screen-printed electrodesDRP-CFLWCL-WE-PEEK
Flow Cell in PEEK - Only working electrodeDRP-FLWCL-IDE-PEEK
Flow Cell in PEEK for Interdigitated ElectrodesDRP-HPLCELL
HPLC Cell for Screen-Printed ElectrodesCell in PEEK designed for working in High-Performance Liquid Chromatography systems. Suitable to be used with standard format Screen-Printed Electrodes with the electrochemical cell in the middle of the strip.
AUT.RHD.TSCSURF
Measuring Cell TSC SurfaceThe TSC Surface is a closed cell designed for electrochemical measurements on flat samples and can be used to study the electrochemical interface between a well defined working electrode and solution and the kinetics of electron transfer reactions. This cell, like all other cells is suitable for measurements with ionic liquids, but it can also be used with aqueous and organic solvents and for corrosion measurements.
DRP-FLOWFITTINGS
Flow-Fittings PackFlow-Fittings Pack. Includes: 2 nuts for grippers, 2 grippers and 80 cm of tubbing 1/16. Suitable to be used with our variety of Flow-Cells
6.07401.110
Flow-through connector set, 1/8"Connection set for flow-through cells with an OMNIS Sample Robot.Contains flangeless sleeve 1/8", 10 pcs., Flangeless fitting with nut, 1/8", 10 pcs. and FEP tubings 1/8" x 1.59 mm, 4 pcs.
6.7402.070
Disposable vials, 2 mm diameter, transmission200 lockable disposable glass vials (borosilicate) with a diameter of 2 mm for analyses of liquids in transmission mode.Compatible with:Holder OMNIS NIR, vial, 2 mm (6.07401.050); DS2500 holder for flow cells (6.7492.000);
6.2764.000
Replacement seals to 62839130Set of seals for Flow cell 10 mm (6.2839.130) to UV/VIS instruments
6.02764.010
Replacement seals for 62839131Replacement seals for the flow-through cell, 10 mm (62839131), for UV/VIS instruments
DRP-BIASPE02
Batch Injection Analysis Cell for Screen-Printed Electrodes (Micropipette P200M)Batch Injection Analysis (BIA) cell made in ABS designed to obtain reproducible flow rate and electronically control the injection volume with a programmable electronic micropipette of 20-200 µL. Suitable to be used with standard format Screen-Printed Electrodes with the electrochemical cell in the middle of the strip. Closing system with powerful magnets.
DRP-BIASPE10
Batch Injection Analysis Cell for Screen-Printed Electrodes (Micropipette P1000M) in ABSBatch Injection Analysis (BIA) cell made in ABS designed to obtain reproducible flow rate and electronically control the injection volume with a programmable electronic micropipette of 100-1000 µL. Suitable to be used with standard format Screen-Printed Electrodes with the electrochemical cell in the middle of the strip. Closing system with powerful magnets.
AUT.RCE
Rotating Cylinder Electrode (RCE)Autolab Rotating Cylinder Electrode (RCE) with a non-carbon liquid contact provides superior noise-free corrosion measurements. The RCE’s Hg contact produces smooth and accurate data that requires no special handling or tools for use in your lab.With the highest rotation rate among commercially available systems, the Autolab Rotating Cylinder Electrode allows you to simulate the widest variety of pipe flow conditions in your lab. The RCE has double the rotation rate of any other 12 mm rotating cylinder electrode making achievable flow rates are 50% higher than any other commercially available RCE.Maximum simulated turbulent flow rates: 1 inch/2.66 cm pipe with schedule 40 is 365 cm/s24 inch/57.48 cm pipe with schedule 40 is 566 cm/sThe Autolab RCE is very compact, only a tenth of the size of other commercially available RCEs. You can access the full rotation rate of the Autolab RCE (100-5000 rpms) with a 12 mm cylinder. Operating temperature range: max 40 C°Exposed sample surface: 3 cm2Image shows RCE and controller, RRDE cell, PGSTAT204 and NOVA software. Keywords: Rotating Cylinder Electrode, Corrosion, RCE, pipe flow, turbulent flow, corrosion in pipes, pipes, Reynolds number, cylindrical sample.