Combined iPt ring electrode
6.0451.300
Combined iPt ring electrode
en
6.0451.300
Överblick över funktioner
Intelligent, combined platinum ring electrode with integrated memory chip for storing sensor data.
This electrode is suitable for redox titrations where the pH value varies, e.g.:
- Oxygen content according to Winkler
- Determination of hydrogen peroxide with KMnO4
- Diazotization titrations
c(KCl) = 3 mol/L is used as reference electrolyte and for storage.
iTrodes can be used on Titrando, Ti-Touch or 913/914 meters.
Tekniska specifikationer
| Shaft material | Glass |
|---|---|
| Measuring range (theoretical) | -2000 ... 2000 |
| Measuring unit | mV |
| Temperature range, long-term (°C) | -5 ... 80 |
| Temperature range, short-term (°C) | -5 ... 80 |
| pH range | 0 ... 14 |
| Max. installation length (mm) | 113 |
| SGJ sleeve | Flexible ground-joint sleeve |
| Shaft diameter top (mm) | 12 |
| Shaft diameter bottom (mm) | 12 |
| Min. immersion depth (mm) | 15 |
| Electrode plug-in head | Metrohm plug-in head K |
| Indicator electrode type | Pt |
| Indicator electrode shape | Ring |
| Diaphragm | Ceramic diaphragm |
| Reference electrolyte type | c(KCl) = 3 mol/L |
| Electrolyte flow rate (μl/h) at 10 cm water column | 10 ... 25 |
| Reference system | LL system |
| Resistance (kOhm) | 5 |
| Diaphragm resistance (kOhm) | 0.4 ... 0.9 |
-
- Sleeve with SGJ 14/12 mm
- 6.1236.050
- Sleeve with SGJ 14/12 mm, polyethylene.
- Sleeve with SGJ 14/12 mm, polyethylene.
- PCS
- 1
- Storage vessel
- 6.2008.040
- Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
- <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
- PCS
- 1
-
- Sleeve with SGJ 14/12 mm
- 6.1236.050
- Sleeve with SGJ 14/12 mm, polyethylene.
- Sleeve with SGJ 14/12 mm, polyethylene.
- PCS
- 1
- Storage vessel
- 6.2008.040
- Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
- <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
- PCS
- 1
-
- 854 iConnect
- 2.854.0010
- The 854 iConnect – Electrode cable and measuring amplifier for intelligent "iTrodes" electrodes (cable length 150 cm).
- <p>The 854 iConnect – Electrode cable and measuring amplifier for intelligent "iTrodes" electrodes (cable length 150 cm).</p>
- PCS
- 1
- Electrolyte 3 mol/L KCl (250 mL)
- 6.2308.020
- Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
- Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
- PCS