요청하신 페이지의 적용되는 국가로 리디렉션되었습니다
Combined iPt ring electrode

Combined iPt ring electrode

6.0451.300

Combined iPt ring electrode

en

6.0451.300

기능 개요

Intelligent, combined platinum ring electrode with integrated memory chip for storing sensor data.
This electrode is suitable for redox titrations where the pH value varies, e.g.:
 

  • Oxygen content according to Winkler
  • Determination of hydrogen peroxide with KMnO4
  • Diazotization titrations


c(KCl) = 3 mol/L is used as reference electrolyte and for storage.
iTrodes can be used on Titrando, Ti-Touch or 913/914 meters.

기술 스펙

Shaft materialGlass
Measuring range (theoretical)-2000 ... 2000
Measuring unitmV
Temperature range, long-term (°C)-5 ... 80
Temperature range, short-term (°C)-5 ... 80
pH range0 ... 14
Max. installation length (mm)113
SGJ sleeveFlexible ground-joint sleeve
Shaft diameter top (mm)12
Shaft diameter bottom (mm)12
Min. immersion depth (mm)15
Electrode plug-in headMetrohm plug-in head K
Indicator electrode typePt
Indicator electrode shapeRing
DiaphragmCeramic diaphragm
Reference electrolyte typec(KCl) = 3 mol/L
Electrolyte flow rate (μl/h) at 10 cm water column10 ... 25
Reference systemLL system
Resistance (kOhm)5
Diaphragm resistance (kOhm)0.4 ... 0.9
이 필드는 필수입니다.
    • Sleeve with SGJ 14/12 mm
    • 6.1236.050
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • PCS
    • 1
    • Storage vessel 
    • 6.2008.040
    • Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
    • <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
    • PCS
    • 1
    • Sleeve with SGJ 14/12 mm
    • 6.1236.050
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • PCS
    • 1
    • Storage vessel 
    • 6.2008.040
    • Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
    • <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
    • PCS
    • 1
    • 854 iConnect
    • 2.854.0010
    • The 854 iConnect – Electrode cable and measuring amplifier for intelligent "iTrodes" electrodes (cable length 150 cm).
    • <p>The 854 iConnect – Electrode cable and measuring amplifier for intelligent "iTrodes" electrodes (cable length 150 cm).</p>
    • PCS
    • 1
    • Electrolyte 3 mol/L KCl (250 mL)
    • 6.2308.020
    • Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
    • Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
    • PCS
    • 1