Combined iPt ring electrode
6.0451.300
Combined iPt ring electrode
en
6.0451.300
Prezentare generală a caracteristicilor
Intelligent, combined platinum ring electrode with integrated memory chip for storing sensor data.
This electrode is suitable for redox titrations where the pH value varies, e.g.:
- Oxygen content according to Winkler
- Determination of hydrogen peroxide with KMnO4
- Diazotization titrations
c(KCl) = 3 mol/L is used as reference electrolyte and for storage.
iTrodes can be used on Titrando, Ti-Touch or 913/914 meters.
Specificații tehnice
| Shaft material | Glass |
|---|---|
| Measuring range (theoretical) | -2000 ... 2000 |
| Measuring unit | mV |
| Temperature range, long-term (°C) | -5 ... 80 |
| Temperature range, short-term (°C) | -5 ... 80 |
| pH range | 0 ... 14 |
| Max. installation length (mm) | 113 |
| SGJ sleeve | Flexible ground-joint sleeve |
| Shaft diameter top (mm) | 12 |
| Shaft diameter bottom (mm) | 12 |
| Min. immersion depth (mm) | 15 |
| Electrode plug-in head | Metrohm plug-in head K |
| Indicator electrode type | Pt |
| Indicator electrode shape | Ring |
| Diaphragm | Ceramic diaphragm |
| Reference electrolyte type | c(KCl) = 3 mol/L |
| Electrolyte flow rate (μl/h) at 10 cm water column | 10 ... 25 |
| Reference system | LL system |
| Resistance (kOhm) | 5 |
| Diaphragm resistance (kOhm) | 0.4 ... 0.9 |
-
- Sleeve with SGJ 14/12 mm
- 6.1236.050
- Sleeve with SGJ 14/12 mm, polyethylene.
- Sleeve with SGJ 14/12 mm, polyethylene.
- PCS
- 1
- Storage vessel
- 6.2008.040
- Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
- <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
- PCS
- 1
-
- Sleeve with SGJ 14/12 mm
- 6.1236.050
- Sleeve with SGJ 14/12 mm, polyethylene.
- Sleeve with SGJ 14/12 mm, polyethylene.
- PCS
- 1
- Storage vessel
- 6.2008.040
- Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
- <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
- PCS
- 1
-
- 854 iConnect
- 2.854.0010
- The 854 iConnect – Electrode cable and measuring amplifier for intelligent "iTrodes" electrodes (cable length 150 cm).
- <p>The 854 iConnect – Electrode cable and measuring amplifier for intelligent "iTrodes" electrodes (cable length 150 cm).</p>
- PCS
- 1
- Electrolyte 3 mol/L KCl (250 mL)
- 6.2308.020
- Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
- Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
- PCS
- 1