You have been redirected to your local version of the requested page
Combined iPt ring electrode

Combined iPt ring electrode

6.0451.300

Combined iPt ring electrode

en

6.0451.300

Prezentare generală a caracteristicilor

Intelligent, combined platinum ring electrode with integrated memory chip for storing sensor data.
This electrode is suitable for redox titrations where the pH value varies, e.g.:
 

  • Oxygen content according to Winkler
  • Determination of hydrogen peroxide with KMnO4
  • Diazotization titrations


c(KCl) = 3 mol/L is used as reference electrolyte and for storage.
iTrodes can be used on Titrando, Ti-Touch or 913/914 meters.

Specificații tehnice

Shaft materialGlass
Measuring range (theoretical)-2000 ... 2000
Measuring unitmV
Temperature range, long-term (°C)-5 ... 80
Temperature range, short-term (°C)-5 ... 80
pH range0 ... 14
Max. installation length (mm)113
SGJ sleeveFlexible ground-joint sleeve
Shaft diameter top (mm)12
Shaft diameter bottom (mm)12
Min. immersion depth (mm)15
Electrode plug-in headMetrohm plug-in head K
Indicator electrode typePt
Indicator electrode shapeRing
DiaphragmCeramic diaphragm
Reference electrolyte typec(KCl) = 3 mol/L
Electrolyte flow rate (μl/h) at 10 cm water column10 ... 25
Reference systemLL system
Resistance (kOhm)5
Diaphragm resistance (kOhm)0.4 ... 0.9
This field is required.
    • Sleeve with SGJ 14/12 mm
    • 6.1236.050
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • PCS
    • 1
    • Storage vessel 
    • 6.2008.040
    • Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
    • <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
    • PCS
    • 1
    • Sleeve with SGJ 14/12 mm
    • 6.1236.050
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • PCS
    • 1
    • Storage vessel 
    • 6.2008.040
    • Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
    • <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
    • PCS
    • 1
    • 854 iConnect
    • 2.854.0010
    • The 854 iConnect – Electrode cable and measuring amplifier for intelligent "iTrodes" electrodes (cable length 150 cm).
    • <p>The 854 iConnect – Electrode cable and measuring amplifier for intelligent "iTrodes" electrodes (cable length 150 cm).</p>
    • PCS
    • 1
    • Electrolyte 3 mol/L KCl (250 mL)
    • 6.2308.020
    • Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
    • Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
    • PCS
    • 1