You have been redirected to your local version of the requested page
Metrosep C 6 - 100/4.0

Metrosep C 6 - 100/4.0

6.1051.410

Metrosep C 6 - 100/4.0

en

6.1051.410

Prezentare generală a caracteristicilor

The 100 mm version of the Metrosep C 6 column is designed to determine standard cations, e.g. in drinking water. Excellent separation of sodium and ammonium is still achieved, despite the very short retention times. The higher capacity of the C 6 material permits larger sample volumes.

Specificații tehnice

Housing materialPEEK
Carrier materialPolybutadienemaleic acid on a silica gel base / spherical silica gel
ManufacturerMetrohm AG
Particle size5 µm
Standard flow0.9 mL/min
Maximum pressure20 MPa
Maximum flow3.5 mL/min
pH range2–7
Column dimensions 4.0 x 100 mm
Temperature range20–60 °C
Standard temperature 20–30 °C

Cromatogramă

  • Cromatogramă
  • Cromatogramă
  • Cromatogramă
This field is required.
    • Threaded stopper
    • 6.2744.060
    • For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.
    • <p>For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.</p>
    • PCS
    • 2
    • Threaded stopper
    • 6.2744.060
    • For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.
    • <p>For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.</p>
    • PCS
    • 2
    • Metrosep C 6 Guard/4.0
    • 6.1051.500
    • The Metrosep C 6 Guard/4.0 contains the C 6 column material and is used to protect against particles and contamination. This considerably lengthens the service life of the analytical separation column. The Metrosep C 6 Guard/4.0 works according to the "On Column Guard System" and is screwed directly onto the respective separation column with virtually no dead volume.
    • <p>The Metrosep C 6 Guard/4.0 contains the C 6 column material and is used to protect against particles and contamination. This considerably lengthens the service life of the analytical separation column. The Metrosep C 6 Guard/4.0 works according to the "On Column Guard System" and is screwed directly onto the respective separation column with virtually no dead volume.</p>
    • PCS
    • 1
    • Metrosep C 6 S-Guard/4.0
    • 6.1051.510
    • The Metrosep C 6 S-Guard/4.0 contains the C 6 column material and is used to protect it against particles and contamination. This considerably lengthens the service life of the analytical separation column.
    • <p>The Metrosep C 6 S-Guard/4.0 contains the C 6 column material and is used to protect it against particles and contamination. This considerably lengthens the service life of the analytical separation column.</p>
    • PCS
    • 1