The Metrosep A Supp 17 columns are anion separation columns for use at room temperature with a very good price-performance ratio. The Metrosep A Supp 17 - 100/4.0 enables rapid separation of the standard anions. Thanks to its great flexibility with respect to flow rates (up to 1.8 mL/min), very short analysis times can be achieved, depending on the separation problem.

Specificații tehnice

Housing materialPEEK
Carrier materialPolystyrene-divinylbenzene copolymer with quaternary ammonium groups
Particle size5 µm
Standard flow0.6 mL/min
Maximum pressure18 MPa
Maximum flow1.8 mL/min
pH range0–14
Column dimensions 100 x 4.0 mm
Temperature range10–70 °C
Standard temperature 25 °C

Cromatogramă

  • Cromatogramă
  • Cromatogramă
    • Threaded stopper
    • 6.2744.060
    • For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.
    • <p>For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.</p>
    • PCS
    • 2
    • Threaded stopper
    • 6.2744.060
    • For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.
    • <p>For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.</p>
    • PCS
    • 2
    • Metrosep A Supp 17 Guard/4.0
    • 6.01032.500
    • The Metrosep A Supp 17 Guard/4.0 reliably protects the Metrosep A Supp 17 analytical separation columns against contamination. Thanks to the "On Column Guard System", the guard column is very easy to handle. The guard column screws easily onto the analytical column. No tools are required.
    • <p>The Metrosep A Supp 17 Guard/4.0 reliably protects the Metrosep A Supp 17 analytical separation columns against contamination. Thanks to the "On Column Guard System", the guard column is very easy to handle. The guard column screws easily onto the analytical column. No tools are required.</p>
    • PCS
    • 1
    • Metrosep A Supp 17 S-Guard/4.0
    • 6.01032.510
    • The Metrosep A Supp 17 S-Guard/4.0 reliably protects the Metrosep A Supp 17 analytical separation columns against contamination. The guard column is simply connected to the separation column using capillary connections. No tools are required.
    • <p>The Metrosep A Supp 17 S-Guard/4.0 reliably protects the Metrosep A Supp 17 analytical separation columns against contamination. The guard column is simply connected to the separation column using capillary connections. No tools are required.</p>
    • PCS
    • 1
    • Metrosep A Supp 17 S-Guard - 50/4.0
    • 6.01032.530
    • The Metrosep A Supp 17 S-Guard 50/4.0 reliably protects the Metrosep A Supp 17 analytical separation columns against contamination. The guard column is simply connected to the separation column using capillary connections. No tools are required.
    • <p>The Metrosep A Supp 17 S-Guard 50/4.0 reliably protects the Metrosep A Supp 17 analytical separation columns against contamination. The guard column is simply connected to the separation column using capillary connections. No tools are required.</p>
    • PCS
    • 1