Extending the scope of ion chromatography: sophisticated sampling, sensitive detection, or multi-parameter analysis.

Hyphenated Techniques

en

Extending the scope of ion chromatography: sophisticated sampling, sensitive detection, or multi-parameter analysis.

Metrohm IC systems can be further extended to include:

  • Sophisticated sampling systems (2060 MARGA and PILS)
  • Straightforward sample preparation systems (CIC)
  • Highly sensitive detection systems (IC-MS, IC-ICP/MS, and more)
  • Multiparameter analysis on a single system, e.g. by combining Metrohm IC with titration or voltammetry (TitrIC and VoltIC)

Sophisticated sampling

Online monitoring of ambient air

2060 MARGA (Monitor for AeRosols and Gases in Ambient air) is a dedicated solution for online monitoring of ambient air.

2060 MARGA collects the ionic load (anions and cations) from the aerosol and the gas fraction of a defined volume of ambient air, brings it into solution, and injects it into a dual channel ion chromatograph for subsequent analysis.

Learn more about 2060 MARGA

 

Inline Sample Preparation for aerosols

Metrohm AeRosol Sampler «MARS» is a sample preparation module that samples aerosol particles from an air stream and brings them into the aqueous phase.

Subsequently, the water-soluble ionic fraction (anions and cations) can be interfaced with any Metrohm ion chromatograph for multi-parameter analysis of aerosols.

Read more about MARS and air monitoring

Straightforward sample preparation

Combustible samples

Pyrohydrolytic Combustion Ion Chromatography (CIC) extends the range of automated ion chromatography to all kinds of combustible samples.

CIC is the preferred method to determine various halogens and sulfur in matrices ranging from solids to viscous, liquid, and gaseous samples.

  • For fully automated routine analysis
  • Superior to offline digestion methods both regarding sample throughput and accuracy of results
  • Qualification and quantification of the individual halogens as well as sum parameters such as AOF or AOX

Brochure: Combustion Ion Chromatography (8.000.5389, PDF, 804 KB)

Brochure: Combustion IC TEI (8.000.5380, PDF, 884 KB)

Sensitive detection

IC/MS and IC-ICP/MS

Expand the scope of your IC system by coupling it with a mass spectrometer (IC-MS) or an inductively coupled plasma mass spectrometer (IC-ICP/MS).

  • Increased sensitivity and selectivity
  • Determination of parameters for which maximum reliability is mandatory (e.g., monitoring of toxic impurities such as haloacetic acids or chromium speciation in drinking water)
  • Quantitative and qualitative data on the sample

Learn more about the hyphenation of IC and mass spectrometers

Multiparameter analysis

Combine direct measurements, titration or voltammetry, and ion chromatography in a single fully automated system for a comprehensive water analysis with multiparameter detection.

TitrIC flex – combining titration and IC

  • Unique combination of titration, direct measurement (e.g., pH), and ion chromatography (all from the same supplier)
  • One autosampler for all three analytical techniques
  • All results in a common database and a combined report
  • Titration and ion chromatography applied independently or in combination for parallel analysis
  • Expandable, modular OMNIS Sample Robot to increase sample throughput

Brochure: TitrIC flex (8.000.5300, PDF, 2.2 MB)

VoltIC Professional – combining voltammetry and ion chromatography

The strengths of IC and voltammetry combined in one powerful system for trace ion analysis.

  • Fully automated analysis
  • Operation with a single software: MagIC Net
  • All results in a common database and a combined report

VoltIC Professional – The flexible solution for combined trace analysis (8.000.5207, PDF, 690 KB)

products

930 Combustion IC PP (AJ) - 2.930.9010

The 930 Combustion IC PP (AJ) enables the analysis of halogens and sulfur in flammable samples of all types using inline combustion digestion (pyrohydrolysis) with subsequent ion chromatography determination (Combustion IC). It comprises all required components, e.g., the Combustion Module from Analytik Jena (2.136.0700), the 920 Absorber Module, the 930 Compact IC Flex Oven/SeS/PP/Deg, and the MagIC Net software. If necessary, the 930 Metrohm Combustion IC package can be supplemented with an Autosampler for solid or liquid samples (MMS 5000 Autosampler). The entire analysis, including sample input and sample digestion, is completely automated and is completely controlled by MagIC Net.

930 Combustion IC DR (AJ) - 2.930.9020

The 930 Metrohm Combustion IC enables the analysis of halogens and sulfur in flammable samples of all types using inline combustion digestion (pyrohydrolysis) with subsequent ion chromatography determination (Combustion IC). It comprises all required components, e.g., the Combustion Module from Analytik Jena (2.136.0700), the 920 Absorber Module, the 930 Compact IC Flex Oven/SeS/Deg, the 800 Dosino for suppressor regeneration and the MagIC Net software.If necessary, the 930 Metrohm Combustion IC package can be supplemented with an Autosampler for solid or liquid samples (MMS 5000 Autosampler). The entire analysis, including sample input and sample digestion, is completely automated and is completely controlled by MagIC Net.

Combustion Oven (TEI) - 2.0136.0600

The Combustion Oven (TEI) is the central unit for pyrohydrolytic combustion of samples as preparation for subsequent analysis with ion chromatography.

Liquid Autosampler CIC (TEI), 30 positions - 2.0136.0610

The Liquid Autosampler CIC (TEI) is used for automated analysis of liquid samples using Combustion IC. It can be used in combination with the Boat Introduction Modules (6.07311.010 or 6.07311.020) and the Liquid Introduction Module (6.07311.040).

Solid Autosampler CIC (TEI) - 2.0136.0620

The Solid Autosampler CIC (TEI) is used for automated analysis of solid samples using Combustion IC. It can be used in combination with the Boat Introduction Modules (6.07311.010 or 6.07311.020). The sample rack for solids no. 1 (6.07312.010) and a cover for the sample rack are already included.

GLS Sampler CIC (TEI) - 2.0136.0630

The GLS Sampler CIC (TEI) is used to analyze liquid gas or gases under increased pressure using Combustion IC. It can be used in combination with either the manual or the automated Liquid Introduction Module for the Combustion Oven (TEI).

Combustion Module (Oven + ABD, AJ) - 2.136.0700

The Combustion Module (Oven + ABD, AJ) enables sample digestion during pyrolysis and oxidation of all types of flammable samples. The Combustion Module consists of the combustion oven and the Auto Boat Driver (automatic sample introduction). Both are products made by Analytik Jena which have been optimized specially for coupling with ion chromatographs.

Auto Boat Drive (AJ) - 2.136.0710

The Auto Boat Drive (ABD) automatically guides the sample boats into the combustion oven. The sample can be put into the boat manually or using an appropriate sampler. This product made by Analytik Jena has been specially optimized for coupling with ion chromatographs.

LPG/GSS Module (AJ) - 2.136.0720

The LPG/GSS Module (AJ) is a sample injection system for either liquefied gases or gases under enhanced pressure. The module is controlled automatically and moves the respective amounts of gas to the combustion oven for combustion. The Analytik Jena product has been optimized specially for coupling with ion chromatographs.

Combustion Module (Oven + LPG/GSS, AJ) - 2.136.0730

The Combustion Module (Oven + LPG/GSS, AJ) enables sample digestion during the pyrolysis of liquefied gases and gases under pressure. The Combustion Module (Oven + LPG/GSS, AJ) is comprised of the combustion oven and the LPG/GSS module. Both are products of Analytik Jena which have been optimized specially for coupling with ion chromatographs.

LPG Module (AJ) - 2.136.0740

The LPG Module (AJ) is a sample injection system for liquefied gases. The module is controlled automatically and moves the respective quantities of gas to the combustion oven for combustion. This product from Analytik Jena has been specially optimized for coupling with ion chromatographs.

Combustion Oven (AJ) - 2.136.0750

The Combustion Oven (AJ) is part of the Metrohm Combustion IC system. It is part of the two Combustion Modules 2.136.0700 and 2.136.0730.

MMS 5000 Autosampler (AJ) - 2.136.0800

Autosampler MMS 5000 (AJ) made by Analytik Jena for use with the Metrohm Combustion IC for fully automatic analysis of liquid and solid samples. To adapt the modular Multi-Matrix sampler to the correct sample type, either the liquids kit (6.7303.000) of the solids kit (6.7302.000) must be used.

920 Absorber Module - 2.920.0010

The 920 Absorber Module combines the Combustion Module with the ion chromatograph. The 920 Absorber Module ensures that the gaseous compounds of the analytes are dissolved and channeled to the IC. It is responsible for the entire Liquid Handling. In addition to Combustion IC, it can also be used for gas analysis.

Metrohm Combustion IC Manual - Quartz - 2.930.9030

The Metrohm Combustion IC Manual - Quartz package enables the analysis of halogens and sulfur in flammable samples of all types using inline combustion digestion (pyrohydrolysis) with subsequent ion chromatography determination (Combustion IC). It comprises all required components, such as the Combustion Oven (TEI) from Trace Elemental Instruments (2.0136.0600), the quartz combustion tube (6.07311.100), the 920 Absorber Module, the 930 Compact IC Flex Oven/SeS/PP/Deg, and the MagIC Net software. If necessary, the Metrohm Combustion IC package can be supplemented with one of the following Autosamplers: Solid Autosampler CIC (TEI), Liquid Autosampler CIC (TEI) or GLS Sampler CIC (TEI).

Metrohm Combustion IC Manual - Ceramic - 2.930.9040

The Metrohm Combustion IC Manual - Ceramic package enables the analysis of halogens and sulfur in flammable samples of all types using inline combustion digestion (pyrohydrolysis) with subsequent ion chromatography determination (Combustion IC). It comprises all required components, such as the Combustion Oven (TEI) from Trace Elemental Instruments (2.0136.0600), the ceramic combustion tube (6.07311.110), the 920 Absorber Module, the 930 Compact IC Flex Oven/SeS/PP/Deg, and the MagIC Net software. If necessary, the Metrohm Combustion IC package can be supplemented with one of the following Autosamplers: Solid Autosampler CIC (TEI), Liquid Autosampler CIC (TEI) or GLS Sampler CIC (TEI).

MARS, Metrohm AeRosol Sampler - A4020600510C

The Metrohm AeRosol Sampler "MARS" is a simpler solution for aerosol monitoring. The MARS can be used as a preconditioning unit for various analytical applications under ambient conditions or in industrial environments. No sample storage is required.Possible applications:Aerosol monitoring inside buildings; Emission monitoring; Monitoring ambient air; Air measurements in tunnels; Quality control in clean rooms; Monitoring of heavy metals (e.g. Cr(VI));

IC-MS and IC-ICP/MS coupling - IC-MS / IC-ICP/MS

The combination of IC with an electrospray ionization mass spectrometer (ESI-MS) or with an inductively coupled plasma mass spectrometer (ICP-MS) solves even complex separation problems with maximum measurement sensitivity. This coupling technology enables unambiguous identification of peaks and is at the same time less susceptible to disruptive matrix effects than ion chromatography with conductivity measurement.Learn more about the coupling of IC and mass spectrometers

TitrIC flex I – The basic hyphenated system for IC and titration - TitrIC flex I

TitrIC flex I – the basic systemFully automated system for direct measurement of temperature, conductivity, and pH value; the titrimetric determination of p value, m value, calcium, and magnesium, and the determination of anions using ion chromatography following Inline Ultrafiltration.The system consists of the 856 Conductivity Module, three 800 Dosinos, Rod Stirrer "Sample Robot", OMNIS Titrator, OMNIS Dosing Module, OMNIS Sample Robot S, and 930 Compact IC Flex Oven/SeS/PP/Deg with sequential suppression, and an IC conductivity detector. The system is operated using the OMNIS and MagIC Net software packages.TitrIC flex – the power pack for ion analysis.

TitrIC flex II – the hyphenated IC and titration system for comprehensive anion and cation analysis - TitrIC flex II

TitrIC flex II – for complete analysis of anions and cations.Fully automated system for direct measurement of temperature, conductivity, and pH value, as well as for titrimetric determination of p value and m value. The cations (including calcium and magnesium) and anions are determined simultaneously with ion chromatography following Inline Ultrafiltration. Automatic calculation of the ion balance provides maximum confidence in the results.The system consists of 856 Conductivity Module, two 800 Dosinos, Rod Stirrer "Sample Robot", OMNIS Titrator, OMNIS Sample Robot S, one 930 Compact IC Flex Oven/Deg without suppression and one 930 Compact IC Flex Oven/SeS/PP/Deg with sequential suppression, each with one IC conductivity detector. The system is operated using the OMNIS and MagIC Net software packages.TitrIC flex – the power pack for ion analysis.

VoltIC Professional 1 – The linked system made of IC and voltammetry for parallel determination of anions, cations, and heavy metals - VoltIC Professional I

VoltIC Professional 1 is the perfect combination of ion chromatography and voltammetry for simultaneous determination of anions, cations and heavy metals. MagIC Net controls IC instruments, starts voltammetric determination, and summarizes all of the IC and voltammetry results.Installation instructions

Which ion chromatograph fits your requirements?