Application Finder
- AN-H-124Determination of sodium content in the manufacturing of margarine
This Application Note describes the determination of the total concentration of sodium in precursor solutions used in the manufacturing of margarine. The solutions of the precursors are mixed with edible fats and oils to make margarine. Traces of sodium chloride and other sodium and potassium salts may be added to the margarine during this process, usually in the form of emulsifiers, stabilizers, antioxidants, vitamins, coloring agents or flavor enhancers. The analysis of the total sodium content in the precursor solutions is more efficient and cost-effective for the manufacturers than later total sodium content analyses in the final product.As a rule, argentometric titration of chloride is used for indirect determination of the sodium content of foodstuffs. The assumption behind this approach is that the chloride ions are present in a molar ratio of 1:1 with the sodium ions. This is however not the case when – as is usually the case with foodstuffs containing sodium – additional compounds containing sodium are also present in the margarine. The use of potassium chloride as a partial replacement for sodium chloride in some formulations is an additional source of error.The direct titration of sodium by means of thermometric endpoint titration (TET) eliminates these problems. TET is a direct determination method that not only takes into account the entire sodium content present in the solution but is also not hampered by the presence of potassium ions. In addition to this application note, you can find more information on thermometric sodium determination in foods in our application video available on YouTube:https://youtu.be/lnCp9jBxoEs
- AN-H-125Determination of sodium in soy milk
This application note describes the determination of the total sodium content in soy milk products. The methodology may also be applied to the determination of sodium in milk products from cows, goats and sheep. A standard addition technique is employed to permit the accurate and precise determination of sodium at relatively low levels.
- AN-H-126Determination of silver and nitric acid in silver electrolyte bath
Silver and nitric acid are determined in silver electrolyte solutions by means of thermometric titration. The method provides accurate results in a short time and is ideally suited for routine process control.
- AN-H-127Thermometric analysis of aluminum by back-titration
This Application Note describes the determination of aluminum in samples containing silicon dioxide using thermometric titration and EDTA as the titrant. Excess EDTA is titrated with a Cu2+ solution of known concentration. The initial, uncomplexed Cu2+ ions react immediately with the H2O2 present in the solution, leading to a recognizable sudden increase in temperature.
- AN-H-128Determination of ferrous ion in acidic solutions with permanganate as titrant
This Application Note looks at the determination of ferrous ion in acidic solutions through redox titration with potassium permanganate as titrant and thermometric titration.
- AN-H-129Determination of weak bases in nonaqueous media through catalyzed thermometric endpoint titration (CETT)
Weak, organic bases that are soluble in nonaqueous solvents (including nonpolar solvents) are determined in glacial acetic acid using titration with strong acids, e. g., anhydrous perchloric acid or trifluoromethanesulfonic acid. The endpoint of such titrations can be determined thermometrically, insofar as a suitable thermometric endpoint indicator exists. The exceptional suitability of isobutyl vinyl ether (IBVE) as indicator has been demonstrated.
- AN-H-130Determination of nitrite using sulfamic acid
This Application Note describes the determination of nitrite using thermometric endpoint titration with sulfamic acid. The nitrite content of a solution can be analyzed down to 0.2 mmol/L.
- AN-H-131Determination of titer and blank value for thermometric titrations using tiamo™
This Application Note describes in detail how to determine the blank value and the titer for thermometric titrations using tiamo™.
- AN-H-132Thermometric endpoint titration of hydrogen peroxide with iodometry
Hydrogen peroxide solutions can be determined through thermometric endpoint titration (TET) using iodometry. Iodide is oxidized to become iodine, which is then titrated with a standard thiosulfate solution in an exothermic reaction.
- AN-H-133Automatic sodium determination in cheese
Sodium can be determined thermometrically in cheese without sample preparation and addition of additives. A homogenizer is responsible for distribution and stirring. In addition to this application note, you can find more information on thermometric sodium determination in foods in our application video available on YouTube:https://youtu.be/lnCp9jBxoEs
- AN-H-134Determination of sulfuric acid and phosphoric acid in etching baths using thermometric titration
Thermometric titration can be used for the ready determination of sulfuric acid and phosphoric acid in acid mixtures. An endpoint for each acid appears on the titration curve that can be used to quantify the respective acid.
- AN-H-135Determination of hydrochloric acid and phosphoric acid in etching baths using thermometric titration
Thermometric titration is used for the determination of hydrochloric acid and phosphoric acid in acid mixtures. Two endpoints appear on the titration curve that are used for the determination of the two acids.
- AN-H-136Determination of hydrochloric acid and nitric acid in etching baths using thermometric titration
Thermometric titration is used for the determination of hydrochloric acid and nitric acid in acid baths. The entire acid content is titrated with caustic soda in the initial titration; the hydrochloric acid content is then determined in a second titration using silver nitrate solution.
- AN-H-137Determination of hydrochloric acid and hydrofluoric acid in etching baths using thermometric titration
Thermometric titration is used to determine hydrochloric acid and hydrofluoric acid (hydrogen fluoride) in etching baths containing ethanol and acetonitrile. Two endpoints appear on the titration curve that are used individually for the quantification of the respective acid.
- AN-H-138Determination of nitric acid and hydrofluoric acid in etching baths using thermometric titration
Thermometric titration is used to determine hydrofluoric acid and nitric acid in etching baths containing ethanol and acetonitrile. Two endpoints appear on the titration curve that are used individually for the quantification of the respective acid.
- AN-H-139Determination of nitric acid, hydrofluoric acid and hexafluorosilic acid in simulated etching baths using thermometric titration
Following the addition of caustic soda, hexafluorosilic acid can be determined through back titration of excess hydroxide with hydrochloric acid. Hydrofluoric acid (hydrogen fluoride) is determined by precipitation with aluminum in the presence of sodium and potassium ions. Nitric acid is determined by subtracting the equivalence concentrations of hexafluorosilic acid and hydrofluoric acid from the total acid concentration.
- AN-H-140Titration of phosphoric, nitric, and acetic acid mixtures
Nitric acid, phosphoric acid, and acetic acid are easily determined in etching baths using thermometric titration (TET). Compared to potentiometric titration, TET is faster and more convenient. Analysis is complete in less than two minutes.
- AN-H-141Acid number in crude oil and gas oil according to ASTM D8045
Thermometric titration can determine the total acid number (TAN) of various crude oil products according to ASTM D8045 without requiring any sensor maintenance.
- AN-H-142Determination of metal-organic compounds
Metal-organic compounds are commonly used in organic chemistry, for example as Grignard reagents or as strong bases (e.g., butyl lithium compounds). The knowledge of the exact content of reactive species allows to better plan the required amounts for reactions preventing the waste of material or too low yields.This Application Note describes the analysis of metal organics by thermometric titration using 2-butanol as titrant. Due to the strongly exothermic nature of the reaction between 2-butanol with metal-organic compounds, a fast and quantitative analysis of these substances is possible.
- AN-H-143Sulfuric acid and tartaric acid in tartaric sulfuric anodizing bath – Rapid, sequential determination using a thermometric sensor (thermometric titration)
Tartaric Sulfuric Anodizing (TSA) is an established technique for corrosion protection in the aerospace industry. It is an alternative to the environmentally harmful chromic anodizing process. As such, a method to monitor the levels of sulfuric acid and tartaric acid in TSA plating baths is required. Potentiometric titration methods have been developed, and are widely used across the industry. Their disadvantage is that two titrations with different electrodes and solvents are required.In this Application Note, an alternative method is presented, where the concentration of both acids is determined in sequence using a thermometric sensor. Compared to potentiometric titration, thermometric titration is faster and more convenient (no sensor maintenance required). On a fully automated system, the determination of both parameters takes about 7 minutes.
- AN-H-144Ferrous iron in iron sucrose injection
Iron sucrose injections are used during the treatment of iron deficiency anemia. They contain a mixture of ferric iron (Fe3+) and ferrous iron (Fe2+). Ferrous iron content may be determined by subtracting the ferric iron content from the total determined iron content. Yet, this increases the measurement error due to error propagation. Alternative determination of iron(II) with cerium(IV) by potentiometric titration may be hampered, as the equivalence point cannot be determined unequivocally. Determination by thermometric titration is a more robust and therefore more reliable alternative, as this method is unaffected by the sample matrix. Here, the endpoint of the titration is indicated by a fast responding thermometric sensor. Endpoint detection is further improved by spiking the sample with 0.2% ammonium iron(II) sulfate (FAS), increasing the reliability of the determination. Compared to potentiometric titration, thermometric titration is faster and more convenient as no sensor maintenance is required. One determination takes about 2–3 minutes.
- AN-H-145Sulfate in fertilizers – Rapid and reliable determination by thermometric titration
Sulfur is a secondary macronutrient for plants and is essential for chloroplast growth and function. In fertilizers, sulfur is usually provided in the form of sulfate. Traditionally the sulfate content is determined gravimetrically by precipitation with barium. The drawback of this method is that it requires numerous time consuming and laborious analysis steps.In this Application Note, an alternative method is presented, where sulfate is determined by a precipitation titration with barium chloride. Various solid and liquid NPK fertilizers with sulfur contents between 1 and 8% were analyzed. The analysis of sulfate in fertilizers by thermometric titration requires no sample preparation at all for liquid NPK fertilizers, and only minimal sample preparation for solid NPK fertilizers. One determination takes about 3 minutes only. To increase the sensitivity of the method, the samples are spiked with a standard sulfuric acid solution, which is then considered when calculating the result.
- AN-H-146Ammonium and urea nitrogen in NPK fertilizers
Fertilizers are applied in the agricultural sector to provide more essential nutrients to growing plants. The so-called «NPK» fertilizers provide such nutrients to plants with its three main components (N – nitrogen, P – phosphorous, K – potassium). In fertilizers, nitrogen is mainly provided in three forms: as ammonium nitrate (NH4NO3), ammonia (NH3), and urea (H2NCONH2). Determination of the individual nitrogen-contributing components is often laborious work. Thermometric titration offers the possibility to rapidly determine the amount of ammoniacal nitrogen and urea nitrogen in a single titration using sodium hypochlorite as titrant.
- AN-H-147Potassium in fertilizers – Rapid and reliable determination by thermometric titration
Potassium is a primary macronutrient for plants, as it plays an important role in water regulation as well as plant growth. In NPK fertilizers, potassium is present besides nitrogen and phosphorus, which are the other two primary macronutrients. Knowing the quality and content of a NPK fertilizer allows an optimal fertilizer management for a planned culture, saving costs and increasing profitability.Traditionally potassium is determined gravimetrically or by flame photometry. In this Application Note, an alternative method is presented, where potassium is determined a precipitation titration. Various solid and liquid NPK fertilizers with potassium contents between 10 and 27% were analyzed. After the removal of any present ammonia, the potassium can be determined reliably in about 5 minutes.
- AN-H-148Potassium in potash
Potash is commonly mined from ore, deposited after ancient inland oceans evaporated. The potassium salt is then purified in evaporation ponds. At the end of this process, the potash is typically obtained as potassium chloride. Potash is mainly used as fertilizer, providing potassium—an essential nutrient—to plants. Additionally, it is used in the chemical industry and to produce medicine. Potassium content in potash is typically determined by flame photometry (F-AES) or ICP-OES. However, these techniques have high investment and running costs. By applying the historically used gravimetric precipitation reaction as a thermometric titration, it becomes possible to rapidly and inexpensively determine the potassium content in potash within minutes.
- AN-PAN-1001Online analysis of hydrogen sulfide and ammonia in sour water stripper
This Process Application Note details the simultaneous online analysis of H2S and NH3 in sour water which was previously treated in the sour water stripper (SWS). The method includes automatic cleaning and calibration. Fast and accurate results are continuously supplied for process control.
- AN-PAN-1002Online monitoring of cyanide and gold in gold leaching solution
Gold leaching by cyanidation requires precise monitoring of cyanide and gold. Online process analyzers perform such measurements, improving safety and compliance.
- AN-PAN-1003Online analysis of amines concentration in carbon capture plants
Carbon capture systems strip carbon dioxide from flue gases. Online analysis of amines and carbon dioxide enhances amine usage efficiency and reduces operational costs.
- AN-PAN-1004ABC Titration: Analysis of alkali, carbonate, hydroxide, and sulfide in pulping liquors
The Kraft process is the dominant pulping process in the pulp and paper industry with the highest chemical recovery efficiency. In order to run each part of the papermaking process optimally, constant quality checks and analyses should be performed. This Process Application Note illustrates the straightforward online analysis of alkali (active, effective, total titratable alkali (TTA)), carbonate, hydroxide, sulfide and the causticizing degree (CE%) in pulping liquors using a 2060 Process Analyzer from Metrohm Process Analytics.
- AN-PAN-1005Analysis of calcium, magnesium in brine
In this Process Application Note, the analysis of low concentrations of calcium and magnesium (0–20 µg/L) in brine is addressed. The presence of calcium and magnesium can shorten the performance and lifetime of the membranes used in the chlor-alkali industry for the production of chlorine. Accurate online monitoring of the hardness is needed in several stages of the process. Other parameters such as acidity, carbonate, hydroxide, silica, alumina, ammonia, iodate and chlorine can also be analyzed online.
- AN-PAN-1006Online analysis of zinc, sulfuric acid, and iron during zinc refining
This Process Application Note is dedicated to the online analysis of zinc, iron and sulfuric acid in several stages of the zinc production process. Additionally, traces of germanium, antimony, as well as several transition metals (e.g., Ni, Co, Cu, Cd) can be precisely determined (<50 µg/L) in the purification filtrates and reactor trains.
- AN-PAN-1007Online analysis of peroxide in the HP-PO process
Monitoring hydrogen peroxide content online in the HP-PO production process requires a rugged explosion-proof solution like the 2060 TI Ex Proof Process Analyzer.
- AN-PAN-1009Online analysis of ammonia, nitrate, and nitrite in wastewater
This Process Application Note deals with online measurements of ammonia, nitrite, and nitrate in wastewater treatment plants. These nitrogen compounds are analyzed simultaneously using a drift-free colorimetric measurement in a multi-parameter process analyzer from Metrohm Process Analytics.
- AN-PAN-1010Online analysis of sulfuric acid and zinc sulfate in the viscose process
Monitoring sulfuric acid and zinc sulfate in the viscose wet-spinning process is essential. Online potentiometric titration and colorimetric analysis are recommended for this purpose.
- AN-PAN-1011Online analysis of permanganate absorption number (PAN)
Permanganate absorption number (PAN) analysis per ISO 8660 ensures caprolactam purity, a precursor of Nylon 6. This application describes real-time, continuous PAN monitoring.
- AN-PAN-1012Online analysis of nickel ion & hypophosphite content
In an electroless plating bath, the consumed ingredients have to be regularly replenished to ensure an even layer of nickel-phosphorus alloy. This requires online monitoring of the active bath constituents. Parameters to be controlled are pH value (4.5–5.0) as well as nickel (NiSO4 < 10 g/L) and hypophosphite concentration (NaH2PO2: 1–12%). Other measurement options include sulfate, alkalinity, and organic additives (via CVS).
- AN-PAN-1013Online analysis of boric acid in the cooling water of pressurized water reactors
Boric acid requires precise monitoring in the primary circuit to control nuclear reactor reactivity. The 2060 TI Process Analyzer monitors boric acid online in near-real time.
- AN-PAN-1016Online analysis of silica in boiler feed water of power plants
Excessive silica concentrations in the boiler feed water can lead to deposits on turbine blades and must therefore be avoided. Silica analysis is carried out via differential photometry using a leading-edge technology thermostatic cuvette module for non-sample contact at the detector. Typical concentration ranges for silica are 0–50 ppb and 0–1 ppm or higher.
- AN-PAN-1018Online analysis of acids, bases, and aluminum in anodizing baths
Anodizing metal surfaces improves resistance against corrosion and wear. Etching baths can be monitored precisely online with the 2060 TI Process Analyzer or 2026 HD Titrolyzer.
- AN-PAN-1019Online analysis of acids and iron in pickling baths
Pickling baths are used in the galvanic industry to clean steel surfaces and prevent corrosion through passivation. Maintaining specific Fe2+/Fe3+ and free acid/total acid ratios is vital to ensure the baths' optimal performance, which directly impacts the final product quality and reduces production costs by minimizing reagent consumption. This application presents a method to regularly monitor the acid and iron composition in pickling baths online by using a process analyzer from Metrohm Process Analytics.
- AN-PAN-1026Mercaptans and hydrogen sulfide in raw oil in accordance with ASTM D3227 and UOP163
Online mercaptan and H₂S monitoring with the 2060 TI Ex Proof Analyzer certified for Zone-1 and Zone-2 areas.
- AN-PAN-1027Online monitoring of TBC in styrene storage tanks according to ASTM D4590
Reliable monitoring of TBC in styrene according to ASTM D4590 requires an explosion-proof solution like the 2060 TI Ex Proof Analyzer.
- AN-PAN-1028Monitoring tetramethylammonium hydroxide (TMAH) in developer online
The chemicals used in the manufacture of semiconductors must exhibit an exceptional purity, because even traces of contaminants have a negative effect on electrical properties. For the manufacture of printed circuit boards, the light-sensitive photoresist applied to the substrate (wafer) is exposed to light at defined areas with the aid of a photo template and then developed in a chemical reaction. The developer contains 2.38 to 2.62% tetramethylammonium hydroxide (TMAH) and ensures that the exposed areas can be readily separated from the substrate. The monitoring of the TMAH concentration in the developer solution takes place with a process analyzer from Metrohm Applikon that is configured specially for titration. In addition to this, the analyzer helps with the mixing of the TMAH solutions.
- AN-PAN-1029Monitoring peracetic acid (PAA) in a beverage bottling facility
Precise online monitoring of peracetic acid (PPA) for beverage bottling requires a reliable stainless steel process analyzer.
- AN-PAN-1032Monitoring corrosion in power plants with online process analysis
Corrosion in the water-steam circuit of power plants leads to shorter lifetimes of most metal components and potentially dangerous situations. Flow Accelerated Corrosion (FAC) is a specific case, leading to thinned pipes and elevated Fe concentrations in the circuit. Additionally, metal transport issues such as with Cu from copper heat exchangers can lead to deposition on the high pressure turbine blades, decreasing their efficiency. Current methods can monitor but not prevent these issues, and analysis times are extremely long (up to three weeks). In combination with the power plant’s Distributed Control System (DCS), online monitoring of Fe and Cu with the 2060 Process Analyzer from Metrohm Process Analytics ensures that corrosion can be controlled before it affects the power plant efficiency, ultimately decreasing downtime and lowering maintenance costs. Results are offered within 20 minutes, allowing fast adjustments to the water-steam circuit to protect company assets.
- AN-PAN-1036Online determination of alkalinity and hardness in process and make up water for beer production
Beer is a popular beverage consumed by millions of people for enjoyment, despite its humble beginnings as a water purification technique in pre-modern times. Brewing beer requires large amounts of water which must adhere to strict alkalinity, hardness, and pH parameters to ensure uniformity in flavor and appearance between each batch. Alkalinity is introduced by carbonates and hydroxides in water which raise and buffer the pH. Hardness, balanced to a large degree by the alkalinity, comes from Ca and Mg ions, mainly present as hydrogen carbonates. Depending on the concentration ranges, the 2035 Process Analyzer or the 2060 Process Analyzer are ideally suited for the fully automatic execution of these important analyses, as well as additional parameters like pH or conductivity. These process analyzers can signal the plant’s distribution system to correct the water chemistry, ensuring consistent product quality. In addition to alkalinity and water hardness, numerous other parameters can also be determined (pH, conductivity, etc.).
- AN-PAN-1037Online measurement of the acid number (AN) in oils with thermometric titration (ASTM D8045)
Online acid number analysis in various oil products is possible with thermometric catalytic titration according to ASTM D8045 using the 2060 TI Ex Proof Process Analyzer.
- AN-PAN-1054Online monitoring of hydrogen peroxide during the CMP process
The planarity and smoothness of silicon wafers are fundamental to manufacture optimal semiconductor devices, and Chemical Mechanical Planarization (CMP) is the most common technology used to achieve ultra-flat surfaces. A slurry is used for this purpose, composed of deionized water, a colloidal silicon or alumina liquid dispersion, and hydrogen peroxide, which has to be constantly monitored at all times.Online monitoring of the CMP process is necessary to avoid chemical waste and enhance wafer production yields. Metrohm Process Analytics can measure not only the H2O2 concentration, but also pH, conductivity, and temperature using the multipurpose 2060 Process Analyzer.
- AN-T-003Salt content (NaCl) of canned food
Determination of chloride in canned vegetables by potentiometric titration with silver nitrate using the Ag-Titrode.
- AN-T-004Chloride in meat products
In order to maintain product quality, the sodium chloride content in meat products must be monitored, as the limit values defined by the respective public health authorities must not be exceeded. The chloride content in food correlates with the salt content, its determination is therefore described in various norms and standards. However, preparation of meat samples is time consuming, as it requires homogenization with a mixer and a chloride extraction with water.In order to reduce workload and working hours, this Application Note describes a fully automatic potentiometric titration of chloride with silver nitrate in meat products based on ISO 1841-2, including fully automated sample preparation using a Polytron homogenizer.
- AN-T-006Trace chloride in cement and clinker
Determination of trace chloride in cement and clinker by potentiometric titration with silver nitrate using the Ag-Titrode.
- AN-T-008Sulfate in brine
Determination of sulfate in brine by indirect potentiometric titration with EGTA using platinum and tungsten electrodes.
- AN-T-009Sulfate in cement
Determination of sulfate in cement by indirect potentiometric titration with EDTA using platinum and tungsten electrodes.
- AN-T-010Anionic surfactants in shower lotions and shampoos
Determination of anionic surfactants in shower lotions and shampoos by potentiometric titration with TEGO®trant A100 using the «Ionic Surfactant» electrode.
- AN-T-011Anionic surfactants in a nickel plating bath
Determination of anionic surfactants in a nickel plating bath by potentiometric titration with TEGO®trant A100 using the «Ionic Surfactant» electrode.
- AN-T-012Cationic surfactants in hair conditioner
Determination of cationic surfactants in hair conditioner by potentiometric titration with dioctyl sodium sulfosuccinate using the «Ionic Surfactant electrode.
- AN-T-013Cationic surfactant (cetrimide) in an antiseptic disinfectant
Determination of the cationic surfactant «cetrimide» in an antiseptic disinfectant by potentiometric titration with sodium dodecyl sulfate using the «Ionic Surfactant» electrode.
- AN-T-014Chlorhexidine in a wash lotion
Determination of chlorhexidine in wash lotion by potentiometric titration with sodium tetraphenylborate using the NIO surfactant electrode.
- AN-T-015Nonionic surfactants in liquid household cleaners
This application note shows a reliable way to determine the content of non-ionic surfactants in liquid cleaning solutions by potentiometric titration.
- AN-T-016Nonionic surfactants in compact washing powders
Determination of nonionic surfactants in compact washing powders by potentiometric titration with sodium tetraphenylborate using the NIO surfactant electrode.
- AN-T-017Determination of ampicillin content
Determination of ampicillin in raw and pure products through potentiometric titration with Hg(II) using the combined Au electrode. Keyword: Antibiotics
- AN-T-018Determination of total penicillin content
Determination of total penicillin content through potentiometric titration with Hg(II) using the combined Au electrode. Keyword: Antibiotics
- AN-T-019Cyanide and silver in a silver plating bath
Simultaneous determination of cyanide and silver in a silver plating bath by potentiometric titration with silver nitrate using the Ag-Titrode.
- AN-T-020Cr(VI) and Cr(III) in chromium baths
Determination of Cr(VI) and Cr(III) in chromium baths by iodometric potentiometric titration with thiosulfate using the combined Pt electrode.
- AN-T-021Sn(II) and sulfuric acid in a tin plating bath
Determination of Sn(II) and sulfuric acid in an acidic tin plating bath by potentiometric titration.
- AN-T-022Cyanide in alkaline plating baths for cadmium, copper, lead or zinc
Determination of cyanide in alkaline plating baths by potentiometric titration with silver nitrate using the Ag-Titrode.
- AN-T-023Hydroxide and carbonate in alkaline plating baths for cadmium, copper, lead, or zinc
Determination of hydroxide and carbonate in alkaline plating baths by potentiometric titration with HCl using the combined glass electrode.
- AN-T-024Metal contents of alkaline plating baths for cadmium, copper, lead or zinc
Determination of cadmium, copper, lead, and zinc in alkaline plating baths by potentiometric titration with EDTA using the Cu-ISE.
- AN-T-025Hydrogen peroxide content in aqueous solutions
Peroxides are often used for disinfection and water treatment purposes due to their antiseptic properties. Lower concentrations between 0.3–3% are used in households, while higher concentrations can be used for sterilization purposes. Additionally, peroxides are utilized as oxidizing and bleaching agents. Peroxides, perborates, and percarbonates can easily be determined by titration. This application note presents two titration methods for peroxide analysis: ASTM D2180 for concentrated hydrogen peroxide solutions, and a second method for trace determination of hydrogen peroxide, suitable for concentrations as low as 0.4 mg/L.
- AN-T-026Perborate, percarbonate, or persulfate in washing powder
Determination of perborate, percarbonate, or persulfate in washing powder by iodometric potentiometric titration using the Pt-Titrode.
- AN-T-027Alkalinity of amine-containing gas washing solutions
Determination of the alkalinity of gas washing solutions containing alkanolamines by potentiometric titration with sulfuric acid using the combined glass electrode.
- AN-T-028Hydrogen sulfide and mercaptans in petroleum products
Simultaneous determination of hydrogen sulfide and mercaptans in petroleum products by potentiometric titration with silver nitrate using the Ag-Titrode.
- AN-T-029Alkyllead (anti-knock agent) in gasoline
Determination of alkyllead compounds in petrol (gasoline) after reaction with iodine monochloride by potentiometric titration with EDTA using the Cu-ISE.
- AN-T-031Na2O (free base) and SiO2 (silicate) in water glass
Determination of Na2O and SiO2 in water glass by potentiometric titration with HCl using the Sb electrode.
- AN-T-032Sulfide and hydrogen sulfide in water
This Application Note presents a potentiometric titration method for trace H2S analysis in water on an OMNIS system using silver nitrate and an Ag Titrode.
- AN-T-033Lidocaine in ointments
Determination of lidocaine in ointments by potentiometric titration with sodium tetraphenylborate using the NIO surfactant electrode.
- AN-T-034Hydrofluoric and nitric acid in etching baths
Determination of hydrofluoric and nitric acid in etching baths by potentiometric titration.a) Determination of the total acid content using the combined Sb electrode and NaOH as titrant.b) Determination of hydrofluoric acid using the F-ISE and the titrant La(NO3)3.The concentration of nitric acid is then determined by calculation.
- AN-T-035Tranexamic acid in injection solutions
Determination of tranexamic acid in injection solutions by nonaqueous potentiometric titration with perchloric acid using a glass electrode.
- AN-T-036Benzydamine hydrochloride in a disinfectant solution
Determination of benzydamine hydrochloride {1-benzyl-3-[3-(dimethylamino)-propoxy]-1H-indazole hydrochloride} in disinfectant solution by potentiometric titration with sodium tetraphenylborate using the NIO surfactant electrode.
- AN-T-037Nitrogen content of nitrocellulose
Determination of the nitrogen content of nitrocellulose by potentiometric titration with Fe(II) using a combined Pt electrode.
- AN-T-038Iron content of iron powder
Determination of the iron content of iron powder by potentiometric titration with potassium dichromate using the Pt-Titrode.
- AN-T-039Free alkali in sodium hypochlorite
Determination of free alkali in sodium hypochlorite by potentiometric titration with hydrochloric acid using a combined glass electrode.
- AN-T-040Determination of phenylglycine content
Determination of phenylglycine through nonaqueous potentiometric titration with sodium methylate using a special combined glass electrode. Keyword: Antibiotics
- AN-T-042Citric and oxalic acid in mixtures
Citric acid and oxalic acid are present in many products, such as foods or chemical solvents (e.g., decontamination solutions). Both acids are reducing agents and citric acid is additionally a powerful antioxidant. Due to their mutual impact (buffer effect), a content calculation is only possible with correction factors for each acid. A fast and accurate determination by potentiometric titration using the dEcotrode plus and sodium hydroxide as titrant can be realized in this Application Note.
- AN-T-043Bromine index in low-level standards
Determination of the bromine index in low-level standards by bivoltametric titration with bromide/bromate using a double Pt electrode.
- AN-T-045Acetate, chloride, and phosphate in an infusion solution
Determination of acetate, chloride, and phosphate in an infusion solution by potentiometric titration with sodium hydroxide after conversion of the anions to the corresponding acids.
- AN-T-046Soap content of soap noodles
Determination of the soap content of soap noodles by potentiometric titration with TEGO®trant A100 using the «Ionic Surfactant» electrode.
- AN-T-047Soaps and anionic surfactants in washing powder by potentiometric two-phase titration
Determination of soaps and anionic surfactants in washing powder by potentiometric two-phase titration with TEGO®trant A100 using the «Surfactrode Resistant» electrode.
- AN-T-048Anionic surfactants in a shower oil by potentiometric two-phase titration
Determination of anionic surfactants in shower oil by potentiometric two-phase titration with TEGO®trant A100 using the «Surfactrode Resistant» electrode.
- AN-T-049Cationic surfactants in a household cleaner by potentiometric two-phase titration
Determination of cationic surfactants in a household cleaner by potentiometric two-phase titration with sodium dodecylsulfate using the «Surfactrode Resistant» electrode.
- AN-T-050Nonionic surfactant nonylphenol ethoxylate (8 EO)
This application note describes the determination of nonylphenol ethoxylate by potentiometric titration with sodium tetraphenylborate using the NIO surfactant electrode.
- AN-T-055Determination of Lauryl Sulfate
Due to its price and wide availability, the anionic surfactant sodium lauryl sulfate (SLS; SDS) can be found in many detergents as an emulsifier or as a fat solvent e.g., in cleaning or cosmetic products. To avoid causing severe dry skin and hair, and thus skin irritation, regulations in many countries have restricted the sodium lauryl sulfate concentration in ready-to-use products to a range between 0.05–2.5% SLS. To control the concentration of SLS in different products, a titration is carried out with TEGO® trant A100 and the Optrode. The evaluation is done automatically by means of a software, leading to reliable and reproducible results.
- AN-T-056Lauryl ether sulfate by photometric/turbidimetric titration
Determination of lauryl ether sulfate (LAES) by potentiometric/turbidimetric titration with TEGO®trant A100 using the 610 nm Spectrode.
- AN-T-057Calcium in aqueous solutions by photometric titration
Determination of calcium in aqueous solutions by photometric titration with EDTA using the 610 nm Spectrode.
- AN-T-058Sum of calcium and magnesium in cement by photometric titration
Determination of the sum of calcium and magnesium in cement by photometric titration with EDTA using the 610 nm Spectrode.
- AN-T-060Aluminum in cement by photometric titration
Determination of aluminum in cement by photometric back-titration of the EDTA excess with zinc sulfate using the 610 nm Spectrode.
- AN-T-061Traces of calcium in brine by photometric titration
Determination of traces of calcium in brine by photometric titration with 1,2-diaminocyclohexanetetraacetic acid using the 610 nm Spectrode.
- AN-T-062Analysis of nitrite solutions
Determination of nitrite in aqueous solutions by potentiometric back-titration of the added permanganate excess with ammonium iron(II) sulfate using the Pt-Titrode.
- AN-T-063Citrate in mineral water drinks
Determination of citrate in mineral water drinks by potentiometric titration with copper sulfate using the Cu-ISE. Before the determination, the sample is degassed and passed through a cation-exchange resin.
- AN-T-064Titanium and iron in mixtures
Simultaneous determination of titanium and iron by potentiometric titration with potassium dichromate using a platinum electrode. Before determination, Ti4+ and Fe3+ are reduced with Cr2+.
- AN-T-065Astemizole in raw products
Determination of the antihistamine astemizole in raw products by nonaqueous potentiometric titration with perchloric acid using separate electrodes.
- AN-T-066Calcium in cheese
Determination of calcium in cheese by potentiometric titration with EGTA using the Cu-ISE.
- AN-T-067Determination of tallow ethoxylates (nonionic surfactants)
Tallow amine ethoxylates are toxic to aquatic life, and therefore their use is restricted. This Application Note explains an approach to determine these non-ionic surfactants potentiometrically.
- AN-T-068Determination of coconut oil ethoxylates (nonionic surfactants)
This application note shows how coconut oil ethoxylates can be determined via potentiometric titration.
- AN-T-069Iron and nickel in binary mixtures
Determination of iron and nickel in binary mixtures by potentiometric titration with EDTA at different pH values using the Cu-ISE.
- AN-T-070Determination of calcium pantothenate
Determination of calcium pantothenate by nonaqueous potentiometric titration with perchloric acid using separate electrodes.
- AN-T-071Determination of palladium using the «Ionic Surfactant» electrode
Determination of palladium(II) by potentiometric titration with hexadecylpyridinium chloride using the «Ionic Surfactant» electrode.
- AN-T-072Reducing sugars in wine and candies
Determination of reducing sugars in wine and candies according to Fehlings method by potentiometric/iodometric titration using the Pt-Titrode.
- AN-T-073Fully automated determination of conductivity, pH value, and alkalinity in tap water including sample preparation
The automated system Basic water analysis determines conductivity, pH value, and alkalinity in all kind of water samples. The high degree of automation (e.g., automated sample addition, automated calibration as well as automated titer and cell constant determination) minimizes errors and guarantees an outstanding reproducibility.
- AN-T-074Conductivity, pH value, alkalinity, and hardness in tap water
In this application note, a fully automated system is presented which allows the determination of several parameters according to various standards within one analysis. These include conductivity (ISO 7888, EN 27888, ASTM D1125, EPA 120.1), the pH value (EN ISO 10523, ASTM D1293, EPA 150.1), alkalinity (EN ISO 9963, ASTM D1067, EPA 310.1), and Ca/Mg content (ISO 6059, ASTM D1126, EPA 130.2). Additionally, the system transfers the required sample volume into an external titration vessel for the analysis, reducing manual sample preparation. Furthermore, all sensors can be automatically calibrated and the titer of each titrant can also be determined.
- AN-T-075Conductivity, pH value, alkalinity, and chloride in tap water
In this application note, a fully automated system is presented which allows the determination of several parameters according to various standards within one analysis. These include conductivity (ISO 7888, EN 27888, ASTM D1125, EPA 120.1), pH value (EN ISO 10523, ASTM D1293, EPA 150.1), alkalinity (EN ISO 9963, ASTM D1067, EPA 310.1), and chloride content (ISO 9297, ASTM D512, EPA 325.3). Additionally the system transfers the required volume of sample into an external titration vessel, further reducing manual sample preparation. Furthermore, all sensors can be calibrated automatically and the titer of each titrant can also be determined.
- AN-T-076Conductivity, pH value, alkalinity, hardness, and chloride in tap water
In this application note, a fully automated system is presented which allows the determination of several parameters according to various standards within one analysis. These include conductivity (ISO 7888, EN 27888, ASTM D1125, EPA 120.1), pH value (EN ISO 10523, ASTM D1293, EPA 150.1), alkalinity (EN ISO 9963, ASTM D1067, EPA 310.1), Ca/Mg (ISO 6059, ASTM D1126, EPA 130.2), and chloride (ISO 9297, ASTM D512, EPA 325.3). Additionally the system transfers the required volume of sample into external titration vessels for the different analyses, reducing manual sample preparation. Furthermore, all sensors can be automatically calibrated and the titer of each titrant can also be determined.
- AN-T-077Photometric determination of sulfate in aqueous solutions
This Application Note describes the photometric determination of sulfate in aqueous solutions using the Optrode (520 nm). Sulfate is precipitated with an excess of barium chloride solution. Excess barium is subsequently titrated with EDTA.
- AN-T-078Determination of aluminum in cement using photometric titration
This Application Note describes the photometric determination of aluminum in cement using the Optrode (574 nm). Following breakdown of the cement sample, the dissolved aluminum is titrated with EDTA. The excess EDTA is titrated back with zinc sulfate solution.
- AN-T-079Determination of calcium in cement by photometric titration of the solubilized product according to EN 196-2
This Application Note covers the photometric determination of calcium in cement using the Optrode (610 nm). After digestion of the cement sample, calcium is titrated with EDTA to the murexide endpoint.
- AN-T-080Determination of iron in cement using photometric titration
This Application Note describes the digestion of a cement sample and the photometric determination of iron in accordance with DIN EN 196-2 by means of Optrode at 610 nm. Sulfosalicylic acid is used as the indicator and EDTA as the titrant for the determination.
- AN-T-081Determination of magnesium in cement using photometric titration
This Application Note is devoted to the photometric determination of magnesium in cement using the Optrode (610 nm). After digestion of a sample aliquot, the magnesium content is determined using EDTA titration.
- AN-T-082Determination of nickel using photometric titration
This Application Note treats the photometric titration of nickel using the Optrode (520 nm). Murexide was used as the indicator and EDTA as the titrant.
- AN-T-083Photometric titration of chondroitin sulfate according to Ph. Eur. and USP
This Application Note details the photometric determination of chondroitin sulfate with 1-hexadecylpyridinium chloride as titrant and with the Optrode (660 nm). The method is in compliance with the Ph. Eur. and the USP.
- AN-T-084Total, calcium, and magnesium hardness in water samples
ASTM D8192 describes the photometric titration of the total hardness, calcium hardness, and magnesium hardness in water with an optical sensor for objective endpoint indication, increasing precision and reliability. The method is suitable for both colored and colorless samples such as groundwater, surface water, wastewater, and drinking water. Using a fully automated OMNIS system equipped with an Optrode ensures that the sample preparation and analysis are repeatable.
- AN-T-085Photometric determination of sulfate
This Application Note describes the photometric determination of sulfate using the Optrode (610 nm). Sulfate is titrated with a lead nitrate solution; dithizone is used as indicator.
- AN-T-086Vitamin C in orange juice
Vitamin C, also known as ascorbic acid or L-ascorbic acid, is an essential nutrient involved in the repair of tissues and the enzymatic production of certain neurotransmitters. It is required for the functioning of several enzymes and immune performance, and is also an important antioxidant. This nutrient is found in many foods and is often used as a dietary supplement.This Application Note describes the photometric determination of ascorbic acid according to the standard ISO 6557-2. To increase the objectivity on the determined equivalence point and the reproducibility of the results, an autotitrator equipped with a photometric sensor, the Optrode, is used. The titrant 2,6-Dichlorophenol-indophenol (DCIP or DPIP) simultaneously serves as titrant and indicator.
- AN-T-087Carboxyl end groups in polymers – Photometric determination based on ASTM D7409
The carboxyl end groups (CEG) in polymers, such as polyethylene terephthalate (PET), are a measure of the number of unreacted carboxylic acid groups at each end of a polymer chain. The number of CEGs may influence the hydrolysis resistance of geosynthetics, such as geogrids and geotextiles. The lower the CEG value the higher is the hydrolysis resistance of geosynthetics, which in turn increases their stability.This Application Note describes the photometric titration of carboxyl end groups in PET pellets using the Metrohm Optrode. The acidic end groups of the polymer are titrated with an ethanolic KOH solution using bromophenol blue as indicator.
- AN-T-088Photometric EDTA titration of bismuth nitrate according to Ph. Eur. and USP
This Application Note describes the photometric determination of bismuth nitrate using the Optrode (520 nm). The sample is titrated with EDTA solution past the endpoint; xylene-orange is used as the indicator. The method for bismuth nitrate fulfills the directives defined in the Ph. Eur. and the USP.
- AN-T-089Photometric EDTA titration of manganese sulfate according to Ph. Eur. and USP
This Application Note looks at the photometric determination of manganese sulfate using the Optrode (610 nm). Manganese is titrated with EDTA; Eriochrome Black T is used as indicator. The method complies with Ph. Eur. and the USP.
- AN-T-090Determination of zinc sulfate
This Application Note describes the photometric determination of zinc sulfate using the Optrode at a wavelength of 610 nm. Complexometric titration of zinc requires EDTA as titrant and Eriochrome Black T as indicator. The method fully complies with Ph. Eur. and USP.
- AN-T-091Fully automatic determination of total content of Ba, Ca, Mg, Pb and Zn in unused lubricating oils
This Application Note describes the determination of total content of Ba, Ca, Mg, Pb and Zn in unused lubricating oil by means of the Optrode (610 nm). An excess of EDTA is first added to the metals. Afterwards, the excess EDTA is titrated back with magnesium chloride solution up to the end point of the indicator Eriochrome Black T.
- AN-T-092Acid number in insulating, transformer and turbine oils – Use of a photometric sensor increases precision and reliability for the determination according to ASTM D974
The acid number (AN) of insulating, transformer, and turbine oils is crucial to ensure safe operation, operating equipment control, and corrosion prevention. These oils generally have low AN specifications and their AN determination by manual color-indicator titration is difficult, especially when analyzing colored samples.Using a Titrator with a photometric sensor to detect the end point ensures that the titrations are always carried out under the same conditions. This greatly increases the precision and reliability of the results, which in turn results in improved monitoring for your operations.
- AN-T-093Total base number in used engine oil – Fully automatic photometric determination increases reliability of results
Basic additives are added to petroleum products to inhibit corrosion as they have a neutralizing effect on acidic compounds, which are formed as a result of degradation processes. Total base number (TBN) indicates the amount of basic additives present and thus can be used as a measure for the degradation of the petroleum product.Using an automated titration system with a photometric sensor to detect the end point ensures that the titrations are always carried out under the same conditions. This improves the precision and reliability of the results.This Application Notes describes the fully automated photometric determination of TBN in used engine oil using the Metrohm Optrode for the indication of the methyl orange endpoint (at 520 nm).
- AN-T-094Fully automated determination of the permanganate index according to EN ISO 8467
The automated system MATi 13 determines the permanganate index in all kind of water samples according to EN ISO 8467. The high degree of automation (e.g., automated sample addition, automated titer and blank value determination) minimizes errors and guarantees robust and reproducible results.
- AN-T-095Automated mixing of a suspension and a solvent using a 50 mL dosing unit
Automated mixing of a suspension and a solvent in a 50 mL dosing unit can be used to add a well-defined amount of a suspension-solvent mixture to a sample solution without clogging the dosing unit and tubing by the undiluted suspension.The method is explained by means of the TAN determination of a petroleum sample using thermometric titration. For a better endpoint recognition, small amounts of a paraformaldehyde-solvent suspension are added (catalyzed endpoint thermometric titration).
- AN-T-096Acid number in lubricants with potentiometric titration
Fresh as well as used petroleum products may contain acidic components as additives or degradation products. The acid number (AN) is a measure for the relative amount of acids present expressed as mg KOH per g sample. Moreover, AN is used as a quality parameter of lubricating oils both for assessing the quality of new formulations and as an indicator for the degradation of such formulations during service. The use of a pH electrode suitable for non-aqueous titrations ensures the reliable determination of the equivalence point. A flexible sleeve diaphragm facilitates its cleaning especially after use in heavily contaminated samples, such as in used engine oils. Using the correct electrode greatly increases the precision and reliability of the results. This Application Note describes the potentiometric determination of the acid number according to ASTM D664 and IP 177 using the pH electrode Solvotrode easyClean.
- AN-T-097Base number in petroleum products with potentiometric titration
Basic chemicals are added to petroleum products to prevent corrosion as they neutralize acidic components that form during the use and aging of these products. The base number (BN) gives an indication regarding the amount of these basic additives present, and it can be used as a measure for the degradation of the petroleum product.This Application Note describes the potentiometric determination of the base number according to ISO 3771, ASTM D2896, and IP 276 using the Metrohm Solvotrode easyClean and a fully automated OMNIS system.
- AN-T-098Total base number according to IP test method 400
This Application Note describes the conductometric determination of the total base number in engine oil according to IP 400.
- AN-T-099Fully automated determination of acidity in orange juice
The present Application Note describes an automated system with which the acidity can be determined in a wide variety of juice samples. The high degree of automation (e.g., automated calibration and titer determination) reduces errors to a minimum and offers outstanding reproducibility.
- AN-T-100Chloride in acidic copper baths
Acid copper baths are mainly used for the copper deposition on semiconductor wafers. Small amounts of chloride increase the speed of deposition and reduce anode polarization. However, higher concentrations are undesired, as this will decrease the quality of the copper deposition. Therefore, it is quite important to monitor the amount of chloride to have an effective, yet high-quality copper deposition process.In this Application Note, a fully automated solution based on titration is presented. In comparison to ion chromatography, titration offers the benefit that no dilution of the sample is necessary, and the hardware is comparatively low-priced. Furthermore, the fully automated solution allows users to minimize handling errors, to reduce workloads, and to guarantee outstanding reproducibility.
- AN-T-101Fully automated determination of chloride in tap water
This Application Note describes an automated system with which the chloride content in various water samples can be determined. The high degree of automation (e.g., automated addition of acid and titer determination) reduces errors to a minimum and ensures outstanding reproducibility.
- AN-T-102Standardization of hydrochloric acid with TRIS
Titrants are normally bought ready to use. However, it is necessary to determine the accurate concentration of your titrant solution on a regular basis using a primary standard. To correct the mentioned variation, a so-called «titer factor» is applied. The titer can be easily and quickly assessed by using the Metrohm brand of autotitrators. Predefined calculation formulas implemented in Metrohm titrators or software, respectively, as well as the automatic storage of the titer factor, makes standardization a simple task.
- AN-T-103Fully automated determination of aluminum in aqueous solution
In many countries, the aluminum concentration in water is limited to 0.2 mg/L. This application note shows how the analysis of aluminum in water can be done fully automatically by complexometric titration with EDTA.
- AN-T-104Fully automated determination of barium in aqueous solution
This Application Note describes the fully automated complexometric determination of barium in aqueous solutions with a copper ion-selective electrode.
- AN-T-105Fully automated determination of bismuth(III) in aqueous solution
This application note shows how to determine the bismuth content automatically in aqueous solution with potentiometric titration.
- AN-T-106Fully automated determination of calcium in milk
In this Application Note, the determination of calcium in milk is shown with the copper ion-selective electrode which is less sensitive to contamination from proteins.
- AN-T-107Fully automated determination of total iron in cement
This Application Note describes the fully automated complexometric determination of total iron in cement with a copper ion-selective electrode.
- AN-T-108Fully automated determination of zinc(II) in aqueous solution
This Application Note describes the fully automated complexometric determination of zinc(II) in aqueous solutions with a copper ion-selective electrode.
- AN-T-109Iodine value in canola and olive oil
This Application Note presents a modified time-saving method to determine iodine value (IV) in edible oils based on several standards (EN ISO 3961, ASTM D5554, etc.).
- AN-T-110Peroxide value in edible oils
This Application Note details a method to determine the peroxide value of edible fats and oils based on EN ISO 27107, EN ISO 3960, AOAC 965.33, Ph.Eur. 2.5.5, and USP<401>.
- AN-T-111Saponification value of edible oils
The saponification value evaluates edible oil quality by indicating the average molecular weight of fatty acids. Its titrimetric determination in canola and olive oil is described here.
- AN-T-112Acid value and free fatty acids in edible oils
This Application Note describes the titration of acid value and free fatty acids in different edible oils, based on the standards EN ISO 660, USP<401>, and Ph.Eur. 2.5.1.
- AN-T-113Hydroxyl number in castor oil and stearyl alcohol – Fast, pyridine-free method for pharmaceutical samples
The hydroxyl number (HN) is an important sum parameter for quantifying the presence of hydroxyl groups in chemicals. As a key quality parameter, it is determined in various substances. For pharmaceutical samples, USP chapter <401> and Ph. Eur. Chapter 2.5.3 describe the determination. However these methods either use toxic pyridine and require refluxing or have long reaction times.In this Application Note, an alternative method according to ASTM E1899 is presented. This method is pyridine-free and does not require refluxing or long reaction times. The determination is performed at room temperature with only a small sample size. The analysis including all preparation steps is performed with a fully automatic OMNIS system. This allows parallel analysis of multiple samples, increasing productivity in the laboratory by 50%.
- AN-T-114Iodometric determination of ascorbic acid in orange juice
This Application Note describes the iodometric, bivoltametric determination of ascorbic acid in orange juice using the Double Pt-sheet electrode.
- AN-T-115Bivoltametric titration with 2,6-dichlorophenol indophenol for the determination of ascorbic acid in orange juice
This Application Note describes the bivoltametric titration of ascorbic acid in orange juice. 2,6-dichlorophenol indophenol (DPIP) is used as titrant; endpoint determination takes place using the Double Pt-sheet electrode.
- AN-T-116Automatic sulfate determination in aqueous solution using a combined ion-selective calcium electrode (Ca ISE)
This Application Note describes automatic sulfate determination using a combined ion-selective calcium electrode. Sulfate is precipitated with an excess of barium chloride solution. Excess barium is subsequently back-titrated with a standard EGTA solution.
- AN-T-117Automatic determination of aluminum and magnesium mixtures with ion-selective copper electrode (Cu ISE)
Aluminum and magnesium ion mixtures are analyzed using back-titration at different pH values. The ion-selective copper electrode is used here as the indicator electrode. First, the aluminum is determined in acidic solution and then the magnesium in alkali solution.
- AN-T-118Automatic determination of zinc and magnesium mixtures with ion-selective copper electrode (Cu ISE)
Zinc and magnesium ion mixtures are analyzed using back-titration at different pH values. The ion-selective copper electrode is used here as the indicator electrode. First, the zinc is determined in acidic solution and then the magnesium in alkali solution.
- AN-T-119Fully automated determination of chloride (NaCl) in bouillon
This Application Note describes an automated system with which the chloride content in bouillon can be determined. The high degree of automation (e.g., automatic addition of acid and titer determination) reduces errors to a minimum and ensures outstanding reproducibility.
- AN-T-120Automatic manganese determination in aqueous solution using the ion-selective copper electrode (Cu ISE)
Manganese in aqueous solution can be determined using back titration in alkali solution. The ion-selective copper electrode is used here as the indicator electrode.
- AN-T-121Automatic indium determination in aqueous solution using the ion-selective copper electrode (Cu ISE)
This application note shows the use of an ion-selective copper electrode to measure the indium concentration in an aqueous solution.
- AN-T-122Automatic thallium determination in aqueous solution using the ion-selective copper electrode (Cu ISE)
Thallium in aqueous solution can be determined using back titration in a weak acidic solution. The ion-selective copper electrode is used here as the indicator electrode.
- AN-T-123Automatic zirconium determination in aqueous solution with ion-selective copper electrode (Cu ISE)
Zirconium can be analyzed quickly and easily in slightly acidic solutions with back titration. The ion-selective copper electrode is used in this Application Note to determine zirconium in aqueous solution.
- AN-T-124Photometric copper determination in aqueous solution
Copper can be determined using photometric titration with EDTA at a wavelength of 520 nm.
- AN-T-125Automatic determination of cadmium in aqueous solution with the Cu ISE
This application note describes the analysis of cadmium in aqueous solution using a copper ion-selective electrode with Cu-EDTA complex used as an indicator.
- AN-T-126Automatic determination of cobalt in aqueous solution with the Cu ISE
This application note describes the fast, accurate determination of cobalt with a copper ion-selective electrode (Cu ISE) and Cu-EDTA complex as an indicator.
- AN-T-127Automatic determination of copper in aqueous solution with the Cu ISE
This Application Note describes the automated complexometric determination of copper with the Cu ISE.
- AN-T-128Automatic determination of magnesium in aqueous solution with the Cu ISE
Magnesium can be determined with the Cu ISE. A small amount of Cu-EDTA complex is used as an indicator, as the Cu ISE is not selective for magnesium itself.
- AN-T-129Automatic determination of nickel in aqueous solution with the Cu ISE
Nickel can be determined with the Cu ISE. A small amount of Cu-EDTA complex is used as an indicator, as the Cu ISE is not selective for nickel itself.
- AN-T-130Automatic determination of lead in aqueous solution with the Cu ISE
Lead can be analyzed with the Cu ISE. Diammonium tartrate is added to the solution to prevent the precipitation of lead hydroxide in the alkali titration medium.
- AN-T-131Calcium, magnesium, and total hardness in water
Water hardness is often determined photometrically using two different indicators and while performing the determination at two different pH values. Additionally, the determination itself is subjective, as the color change is determined by the analyst and not by an analytical device.This application note introduces a more robust option to easily assess calcium, magnesium, and total hardness in water by using the Cu-ISE and two different titrants. Sample preparation is identical for both analyses and can therefore be automated without any issues.
- AN-T-132Titratable acidity in milk and yogurt
The titratable acidity gives an indication of the freshness of milk and yogurt as well as other fermented milk products. The determined titratable acidity in milk is mainly given through the absorption of hydroxyl ions by milk proteins and milk salts. The acidity increases with bacterial acidification and with enzymatic lipolysis. The titratable acidity corresponds to the amount of sodium hydroxide required to titrate 100 g sample to a pH value of 8.30.In this Application Note, an easy and accurate method to determine the titratable acidity in milk according to DIN 10316 and in yogurt according to ISO/TS 11869 and IDF/RM 150 is demonstrated.
- AN-T-133Chloride in milk and milk powder
In order to maintain product quality, the sodium chloride content in dairy products must be monitored and not exceed the limits defined by the respective public health authorities. The chloride content in food correlates with the salt content, its determination is therefore described in various norms and standards. However, preparation of such samples is time consuming, as it includes a chloride extraction with warm water. Whole milk powders in particular are difficult to handle as an inhomogeneous dispersion of fat in the titration suspension occurs.In order to reduce the workload, increase sample throughput, and eliminate the matrix challenges posed by high fat products, this Application Note presents a fully automatic potentiometric titration of chloride with silver nitrate in milk and milk powder based on ISO 21422, IDF 242, AOAC 2015.07, AOAC 2015.08 and AOAC 2016.03
- AN-T-134Chloride in salted butter – Automated standard method reduces saves time and helps increase throughput
The salt content in food is a critical parameter, given that the WHO recommends a maximum daily intake of 5 g for an adult. In butter with a salt content exceeding 0.1%, it can be determined by a precipitation titration of chloride with silver nitrate. However, during manual titration the operator cannot leave the system unattended because he has to exchange the sample beakers manually which is time consuming and prone to errors.This Application Note describes the automated determination of chloride in salted butter in accordance with ISO 15648, ISO 21422, IDF 179 and IDF 242. If automated according to the norms and standards, salt determination can be performed completely unattended with superior reproducibility of results increasing efficiency in the laboratory.
- AN-T-135Chloride in cheese – Automation reduces sample preparation and increases throughput
The WHO recommends a maximum daily intake of 5 g salt for an adult. The chloride content in food correlates with the salt content, its determination is therefore described by various standards. In cheese and cheese products with a chloride content higher than 0.2%, chloride is usually determined by a precipitation titration with silver nitrate. However, time-consuming sample preparation is required, as the cheese has to be homogenized and the chloride extracted with hot water.This Application Note describes the fully automatic determination of chloride in cheese according to EN ISO 5943, ISO 21422, IDF 242 and IDF 88 including sample preparation with a Polytron homogenizer. This increases productivity due to a higher sample throughput and lower work load for the operator.
- AN-T-136Epoxide equivalents in epoxy resin
The epoxy content of epoxy resins has a strong influence on the reactivity of the resins as well as on the properties of the coating obtained from the resin curing process. The epoxy content is thus an important quality control parameter for manufacturers as well as consumers. This analysis is based on the reaction of hydrogen bromide with the epoxy groups of the sample. Hydrogen bromide in turn is produced by the reaction of tetraethylammonium bromide (TEABr) with standardized perchloric acid. The standards EN ISO 3001 and ASTM D1652 describe the determination of the epoxy content expressed as epoxy equivalent weight (EEW) by titration. The use of a Titrando and Solvotrode easyClean instead of manual titration greatly increases the reproducibility and repeatability of the determination.
- AN-T-137Determination of sulfate in sodium sulfate according to Ph. Eur.
In accordance with the European Pharmacopoeia, sodium sulfate is determined with the PB ISE.
- AN-T-138Determination of inorganic sulfate in secondary alkylsulfonate in accordance with DIN EN 14880
Inorganic sulfate is determined in secondary alklysulfonate (raw material) in accordance with DIN EN 14880 with the use of the Pb ISE.
- AN-T-139Standardization of barium acetate as the titrant for conductometric sulfate titration
Barium acetate is used as titrant for conductometric sulfate determination. It can be standardized with desiccated sodium sulfate.
- AN-T-140Automatic photometric determination of lead using the Optrode
Lead is determined at pH 4 to 5 using back titration with zinc sulfate. Xylenol orange is used as an indicator for visualization of the equivalence point. The equivalence point is detected with the Optrode at a wavelength of 574 mm.
- AN-T-141Automatic photometric determination of manganese using the Optrode
Manganese is determined as Mn(II) in aqueous solutions at pH 10 with Eriochrome Black T as indicator. Ascorbic acid is added to ensure that manganese is present in its bivalent form. The precipitation of water-insoluble manganese hydroxide is prevented by adding triethanolamine (TEA). The Optrode is used for detection at a wavelength of 610 nm.
- AN-T-142Determination of barium using automatic photometric titration
Barium is analyzed in alkali media using direct titration with EDTA. Phthalein purple is used as the indicator; the equivalence point is determined with the Optrode at a wavelength of 574 nm.
- AN-T-143Determination of cobalt using automatic photometric titration
Cobalt is analyzed in aqueous solutions using direct titration with EDTA at a pH value of 9. The indicator is murexide. The equivalence point is determined with the Optrode at a wavelength of 574 nm.
- AN-T-144Mercury analysis using automatic photometric titration
Mercury can be determined in alkali media using back titration with zinc sulfate. Eriochrome black T is used as the indicator for this procedure. The Optrode is used for indication at a wavelength of 502 nm.
- AN-T-145Determination of palladium using automatic photometric titration
Palladium is determined at a pH value of 4 to 5 using back titration with zinc sulfate. Xylenol orange is used as the indicator for visualization of the endpoint. The equivalence point is determined with the Optrode at a wavelength of 610 nm.
- AN-T-146Automatic determination of tin using photometric titration
Tin with EDTA forms very stable complexes in its divalent and tetravalent forms. Hydroxo complexes form in alkali media, which is also why tin is titrated in an acidic medium (pH 2.1). Xylenol orange is used as the indicator. The equivalence point is determined with the Optrode at a wavelength of 574 nm.
- AN-T-147Determination of thallium using automatic photometric titration
Thallium is titrated in slightly acidic medium as Tl(III). Xylenol orange is used as the indicator to determine the endpoint. The equivalence point is determined with the Optrode at a wavelength of 574 nm.
- AN-T-148Determination of zirconium using automatic photometric titration
Zirconium is titrated directly with EDTA in acidic aqueous solution (buffer, pH 1). Eriochrome cyanine R is used as the indicator for this procedure. The equivalence point is determined with the Optrode at a wavelength of 520 nm.
- AN-T-149Determination of thorium using automatic photometric titration
Thorium is titrated with EDTA at a pH value of 4.9. Xylenol orange is used as the indicator for visualization of the equivalence point. The equivalence point is determined with the Optrode at a wavelength of 574 nm.
- AN-T-150Determination of nickel using automatic photometric titration
Nickel analysis can be carried out conveniently in alkali media using photometric titration. Murexide is used as the indicator for visualization of the endpoint. The equivalence point is determined with the Optrode at a wavelength of 574 nm.
- AN-T-151Titration of ketoconazole in accordance with Ph. Eur.
This Application Note describes the nonaqueous acid-base titration of ketoconazole in accordance with the European Pharmacopoeia. The Solvotrode easyClean was used as the electrode.
- AN-T-152Automatic determination of mercaptans in refinery products
Potentiometric titration with silver nitrate can be used for the determination of mercaptans in refinery products. This Application Note describes their automatic determination in a middle distillate sample (gas oil).
- AN-T-153Determination of cadmium using automatic photometric titration
Cadmium can be determined in aqueous solutions using back titration with zinc sulfate. Eriochrome black T is used as the indicator for this procedure. The equivalence point is determined with the Optrode at a wavelength of 610 nm.
- AN-T-154Determination of alpha acids in hops according to EBC 7.4
The alpha acid level (AA%) in hops plays a major role in the bitterness they can impart to beer. The AA% can vary between 1% up to 20% in hops. During boiling in the brewing process, alpha acids transform into iso-alpha acids which make the beer bitter. For this reason, it is important for brewers to know the exact AA value of the hops they use. The determination of AA% in hops with conductometric titration according to the EBC method 7.4 is shown in this Application Note.
- AN-T-156Determination of surfactants on the basis of sugar and polyoxyethylene
Alkyl glycosides, alkyl maltosides and compounds with polyoxyethylene groups (POE) are numbered among the nonionic surfactants. These surfactants can be analyzed by standard titration with TEGO®trant following derivatization – in this case following sulfonation.
- AN-T-157Automatic potentiometric titration of sulfanilamide
The purity of sulfanilamide was determined by means of automatic potentiometric titration using sodium nitrite as the titrant. The solution was spiked with potassium bromide, because bromide ions catalyze diazotization titration.
- AN-T-158Determination of gallium using automatic photometric titration
Gallium is determined at a pH value of 4.7 using back titration with zinc sulfate. Xylenol orange is used as the indicator for visualization of the equivalence point. The equivalence point is determined with the Optrode at a wavelength of 610 nm.
- AN-T-159Basicity and CPR in polyols according to ISO 14899
The basicity and the CPR (controlled polymerization rate) are very important parameters for the quality of polyols used in polyurethane production. The knowledge of these values is crucial to prevent gelation during handling in the production. In this Application Note their determination by automated, potentiometric titration according to ISO 14899 is described.
- AN-T-160Determination of the acid number in acrylic acid
Acrylic acid dimerizes spontaneously. Determining the dimer content is, therefore, a key part of the quality control for acrylic acid. One quality control parameter for the dimerization is the acid number. This Application Note describes its determination by automated, potentiometric titration.
- AN-T-161Sulfate in salts of laxatives and expectorants in accordance with Ph. Eur. 8.0
The composition of salts with laxative and expectorant effects must be determined precisely in medications. The sulfate content is determined using automatic potentiometric titration with EGTA as titrant in accordance with Ph. Eur. 8.0.
- AN-T-162Redox titration of Vitamin C in orange juice with OMNIS
Vitamin C is an important antioxidant and an important component of orange juice. A convenient and precise method for Vitamin C determination in fruit juices is titration, which is also described in numerous standards (ISO 6557/1, ISO 6557/2, AOAC 967.21).OMNIS enables quick and accurate determination of Vitamin C content in orange juice using potentiometric titration with iodine as titrant and a separate double Pt-sheet electrode.
- AN-T-163Complexometric titration of aluminum chloride with OMNIS
OMNIS is the ideal system for quick and accurate determination of aluminum in aluminum chloride using complexometric back titration with an ion-selective copper electrode (Cu-ISE). Copper sulfate is used as the titrant.
- AN-T-164Partial acid number in unsaturated polyester resin according to EN ISO 2114
The partial acid number (also partial acid value) describes the quantity of potassium hydroxide that is required for neutralizing all carboxyl-terminated groups and free acids plus half the anhydride groups in an unsaturated polyesterresin (UPR). This Application Note describes the determination of the partial acid value by automatic, potentiometric titration according to EN ISO 2114 using KOH in ethanol as titrant.
- AN-T-165Total acid number in unsaturated polyester resin according to EN ISO 2114
The total acid number (TAN) indicates the amount of potassium hydroxide required for neutralizing all carboxyl-terminated groups and free acids plus the free anhydride groups in an unsaturated polyester resin (UPR). In this Application Note the TAN determination using automated, potentiometric titration according to EN ISO 2114 using KOH in ethanol as titrant is described.
Did you know?
We are proud to count many of the Fortune 500 Companies to our clients.
Show another