Oil Titrino plus with printer
2.848.3020
Oil Titrino plus with printer
en
2.848.3020
Bu ürün artık üretilmemekte olup destek hizmeti hala devam etmektedir.
Muadil ürün grubuna git
-
- Solvotrode easyClean (fixed cable 1.2 m)
- 6.0229.010
- Combined pH electrode with flexible easyClean diaphragm and fixed cable (1.2 m) for all non-aqueous acid/base titrations. The glass membrane is optimized for poorly conducting solutions, and thanks to the easy-to-clean easyClean diaphragm, the electrode is also well suited for heavily contaminated samples, such as used oil. This electrode can be used with non-aqueous reference electrolytes (lithium chloride or tetraethylammonium bromide). Storage in the respective reference electrolyte.The Solvotrode easyClean is also available under the article number 6.0229.020 with a fixed cable length of 2.0 m.
- <p>Combined pH electrode with flexible easyClean diaphragm and fixed cable (1.2 m) for all non-aqueous acid/base titrations. <br/>The glass membrane is optimized for poorly conducting solutions, and thanks to the easy-to-clean easyClean diaphragm, the electrode is also well suited for heavily contaminated samples, such as used oil. <br/>This electrode can be used with non-aqueous reference electrolytes (lithium chloride or tetraethylammonium bromide). Storage in the respective reference electrolyte.</p><p>The Solvotrode easyClean is also available under the article number 6.0229.020 with a fixed cable length of 2.0 m.</p>
- PCS
- 1
- Stirring propeller / 87 mm
- 6.1909.010
- Propeller stirrer, length from lower edge of SGJ: 96 mm. For use with beakers with 722, 802 Rod Stirrer
- <p>Propeller stirrer, length from lower edge of SGJ: 96 mm. For use with beakers with 722, 802 Rod Stirrer</p>
- PCS
- 1
- Support stand without support rod
- 6.2001.060
- To attach an 801, 804, 803 Stirrer to a Titrando, Titrino plus, Dosimat plus or 856 and 867.
- To attach an 801, 804, 803 Stirrer to a Titrando, Titrino plus, Dosimat plus or 856 and 867.
- PCS
- 1
- Clamping ring
- 6.2013.010
- For support rods with a diameter of 10 mm.
- <p>For support rods with a diameter of 10 mm.</p>
- PCS
- 1
- Support rod / 400 mm
- 6.2016.070
- PCS
- 1
- Electrode holder
- 6.2021.020
- Electrode holder for 4 electrodes and 2 buret tips
- Electrode holder for 4 electrodes and 2 buret tips
- PCS
- 1
- Numerical USB keypad
- 6.2147.000
- Numerical USB keypad for Titrino plus, Dosimat plus, 862 Compact Titrosampler, 869 Compact Sample Changer, 863 Compact Autosampler and 899 Coulometer. With two integrated USB connectors.
- <p>Numerical USB keypad for Titrino plus, Dosimat plus, 862 Compact Titrosampler, 869 Compact Sample Changer, 863 Compact Autosampler and 899 Coulometer. With two integrated USB connectors. </p>
- PCS
- 1
- Adapter USB MINI (OTG) - USB A
- 6.2151.100
- For connecting USB instruments.
- For connecting USB instruments.
- PCS
- 1
- Cable USB MINI (OTG) - USB B, 1.8 m
- 6.2151.120
- For connecting USB instruments.
- For connecting USB instruments.
- PCS
- 1
- TEABr 0.4 mol/L in ethylene glycol (250 mL)
- 6.2320.000
- Electrolyte solution TEABr (tetraethylammonium bromide in ethylene glycol), c(TEABr) = 0.4 mol/L
- Electrolyte solution TEABr (tetraethylammonium bromide in ethylene glycol), c(TEABr) = 0.4 mol/L
- PCS
- 1
- 5 mm hex key for IC Sample Processors
- 6.2621.070
- PCS
- 1
- Hexagon key 2 mm
- 6.2621.130
- 2 mm.
- 2 mm.
- PCS
- 1
- Protective cover for Titrino plus
- 6.2723.310
- Protective cover for display and keypad for all instruments of the Titrino plus family. Suitable for: 848 Titrino plus, 862 Compact Titrosampler, 863 Compact Autosampler, 865 Dosimat plus, 869 Compact Sample Changer, 870 KF Titrino plus, 876 Dosimat plus, 877 Titrino plus, 899 Coulometer.
- <p>Protective cover for display and keypad for all instruments of the Titrino plus family. </p> <p>Suitable for: 848 Titrino plus, 862 Compact Titrosampler, 863 Compact Autosampler, 865 Dosimat plus, 869 Compact Sample Changer, 870 KF Titrino plus, 876 Dosimat plus, 877 Titrino plus, 899 Coulometer.</p> <p> </p>
- PCS
- 1
- Wrench
- 6.2739.010
- For exchange units.
- For exchange units.
- PCS
- 1
- Exchange Unit 20 mL
- 6.3026.220
- Exchange unit with integrated data chip with 20 mL glass cylinder and light protection. PCTFE/PTFE flat stopcock, FEP tubing connection, anti-diffusion buret tip and standard amber glass reagent bottle.
- <p>Exchange unit with integrated data chip with 20 mL glass cylinder and light protection. PCTFE/PTFE flat stopcock, FEP tubing connection, anti-diffusion buret tip and standard amber glass reagent bottle.</p>
- PCS
- 1
- Titrino plus methods USB Stick
- 6.6061.010
- Contains the FOOD PAC, WINE PAC and OIL PAC methods for direct import into the Titrino plus.
- Contains the FOOD PAC, WINE PAC and OIL PAC methods for direct import into the Titrino plus.
- PCS
- 1
- Thermal paper for Custom Neos-N / Q3X
- 6.9001.050
- Thermal paper 60 mm / 25 m for Custom Neos-N / Q3X. New: 25-year legibility with correct storage.1 roll
- <p>Thermal paper 60 mm / 25 m for Custom Neos-N / Q3X. <br/>New: 25-year legibility with correct storage.<br/><br/>1 roll</p>
- PCS
- 4
-
- Custom Q3X thermal printer
- 1.142.0100
- Compact printer with USB interface for 900 Touch Control915 KF Ti-Touch916 Ti-Touch917 Coulometer877 / 848 Titrino plus865 / 876 Dosimat plus91X MeterEco Dosimat / TitratorPaper width 60 mm (40 characters). Including 6.2151.120 USB cable.
- <p>Compact printer with USB interface for<br /> </p><ul><li>900 Touch Control</li><li>915 KF Ti-Touch</li><li>916 Ti-Touch</li><li>917 Coulometer</li><li>877 / 848 Titrino plus</li><li>865 / 876 Dosimat plus</li><li>91X Meter</li><li>Eco Dosimat / Titrator</li></ul><p><br />Paper width 60 mm (40 characters). Including 6.2151.120 USB cable.</p>
- PCS
- 1
- 802 Rod Stirrer for 727 Ti Stand
- 1.802.0010
- Rod stirrer with separate 6.2137.000 Speed controller and 6.1909.010 Propeller stirrer.
- Rod stirrer with separate 6.2137.000 Speed controller and 6.1909.010 Propeller stirrer.
- PCS
- 1
- 804 Ti Stand without stand rod
- 1.804.0010
- Titration stand and controller for 802 Stirrer. The 804 Ti Stand together with the optional 802 Stirrer provides an alternative to the magnetic stirrer. Without stand.
- Titration stand and controller for 802 Stirrer. The 804 Ti Stand together with the optional 802 Stirrer provides an alternative to the magnetic stirrer. Without stand.
- PCS
- 1
- 848 Titrino plus
- 1.848.0010
- Compact titrator fordynamic (DET) titrations with automatic equivalence point finding; monotonic (MET) titrations with automatic equivalence point finding; endpoint titrations (SET);
- <p>Compact titrator for</p><ul><li>dynamic (DET) titrations with automatic equivalence point finding</li><li>monotonic (MET) titrations with automatic equivalence point finding</li><li>endpoint titrations (SET)</li></ul><p> </p>
- PCS
- 1
- Solvotrode easyClean (fixed cable 1.2 m)
- 6.0229.010
- Combined pH electrode with flexible easyClean diaphragm and fixed cable (1.2 m) for all non-aqueous acid/base titrations. The glass membrane is optimized for poorly conducting solutions, and thanks to the easy-to-clean easyClean diaphragm, the electrode is also well suited for heavily contaminated samples, such as used oil. This electrode can be used with non-aqueous reference electrolytes (lithium chloride or tetraethylammonium bromide). Storage in the respective reference electrolyte.The Solvotrode easyClean is also available under the article number 6.0229.020 with a fixed cable length of 2.0 m.
- <p>Combined pH electrode with flexible easyClean diaphragm and fixed cable (1.2 m) for all non-aqueous acid/base titrations. <br/>The glass membrane is optimized for poorly conducting solutions, and thanks to the easy-to-clean easyClean diaphragm, the electrode is also well suited for heavily contaminated samples, such as used oil. <br/>This electrode can be used with non-aqueous reference electrolytes (lithium chloride or tetraethylammonium bromide). Storage in the respective reference electrolyte.</p><p>The Solvotrode easyClean is also available under the article number 6.0229.020 with a fixed cable length of 2.0 m.</p>
- PCS
- 1
- Stirring propeller / 87 mm
- 6.1909.010
- Propeller stirrer, length from lower edge of SGJ: 96 mm. For use with beakers with 722, 802 Rod Stirrer
- <p>Propeller stirrer, length from lower edge of SGJ: 96 mm. For use with beakers with 722, 802 Rod Stirrer</p>
- PCS
- 1
- Support stand without support rod
- 6.2001.060
- To attach an 801, 804, 803 Stirrer to a Titrando, Titrino plus, Dosimat plus or 856 and 867.
- To attach an 801, 804, 803 Stirrer to a Titrando, Titrino plus, Dosimat plus or 856 and 867.
- PCS
- 1
- Clamping ring
- 6.2013.010
- For support rods with a diameter of 10 mm.
- <p>For support rods with a diameter of 10 mm.</p>
- PCS
- 1
- Support rod / 400 mm
- 6.2016.070
- PCS
- 1
- Electrode holder
- 6.2021.020
- Electrode holder for 4 electrodes and 2 buret tips
- Electrode holder for 4 electrodes and 2 buret tips
- PCS
- 1
- Numerical USB keypad
- 6.2147.000
- Numerical USB keypad for Titrino plus, Dosimat plus, 862 Compact Titrosampler, 869 Compact Sample Changer, 863 Compact Autosampler and 899 Coulometer. With two integrated USB connectors.
- <p>Numerical USB keypad for Titrino plus, Dosimat plus, 862 Compact Titrosampler, 869 Compact Sample Changer, 863 Compact Autosampler and 899 Coulometer. With two integrated USB connectors. </p>
- PCS
- 1
- Adapter USB MINI (OTG) - USB A
- 6.2151.100
- For connecting USB instruments.
- For connecting USB instruments.
- PCS
- 1
- Cable USB MINI (OTG) - USB B, 1.8 m
- 6.2151.120
- For connecting USB instruments.
- For connecting USB instruments.
- PCS
- 1
- TEABr 0.4 mol/L in ethylene glycol (250 mL)
- 6.2320.000
- Electrolyte solution TEABr (tetraethylammonium bromide in ethylene glycol), c(TEABr) = 0.4 mol/L
- Electrolyte solution TEABr (tetraethylammonium bromide in ethylene glycol), c(TEABr) = 0.4 mol/L
- PCS
- 1
- 5 mm hex key for IC Sample Processors
- 6.2621.070
- PCS
- 1
- Hexagon key 2 mm
- 6.2621.130
- 2 mm.
- 2 mm.
- PCS
- 1
- Protective cover for Titrino plus
- 6.2723.310
- Protective cover for display and keypad for all instruments of the Titrino plus family. Suitable for: 848 Titrino plus, 862 Compact Titrosampler, 863 Compact Autosampler, 865 Dosimat plus, 869 Compact Sample Changer, 870 KF Titrino plus, 876 Dosimat plus, 877 Titrino plus, 899 Coulometer.
- <p>Protective cover for display and keypad for all instruments of the Titrino plus family. </p> <p>Suitable for: 848 Titrino plus, 862 Compact Titrosampler, 863 Compact Autosampler, 865 Dosimat plus, 869 Compact Sample Changer, 870 KF Titrino plus, 876 Dosimat plus, 877 Titrino plus, 899 Coulometer.</p> <p> </p>
- PCS
- 1
- Wrench
- 6.2739.010
- For exchange units.
- For exchange units.
- PCS
- 1
- Exchange Unit 20 mL
- 6.3026.220
- Exchange unit with integrated data chip with 20 mL glass cylinder and light protection. PCTFE/PTFE flat stopcock, FEP tubing connection, anti-diffusion buret tip and standard amber glass reagent bottle.
- <p>Exchange unit with integrated data chip with 20 mL glass cylinder and light protection. PCTFE/PTFE flat stopcock, FEP tubing connection, anti-diffusion buret tip and standard amber glass reagent bottle.</p>
- PCS
- 1
- Titrino plus methods USB Stick
- 6.6061.010
- Contains the FOOD PAC, WINE PAC and OIL PAC methods for direct import into the Titrino plus.
- Contains the FOOD PAC, WINE PAC and OIL PAC methods for direct import into the Titrino plus.
- PCS
- 1
- Thermal paper for Custom Neos-N / Q3X
- 6.9001.050
- Thermal paper 60 mm / 25 m for Custom Neos-N / Q3X. New: 25-year legibility with correct storage.1 roll
- <p>Thermal paper 60 mm / 25 m for Custom Neos-N / Q3X. <br/>New: 25-year legibility with correct storage.<br/><br/>1 roll</p>
- PCS
- 4
-
- Optrode
- 6.1115.000
- Optical sensor for photometric titrations offering 8 different wavelengths. The wavelength can be switched using the software (tiamo 2.5 or higher) or with a magnet. The glass shaft is completely solvent-resistant and easy to clean. For example, this space-saving sensor is suitable for:Non-aqueous titrations in accordance with USP or EP; Determinations of carboxyl end groups; TAN/TBN in accordance with ASTM D974; Sulfate determination; Fe, Al, Ca in cement; Water hardness; Chondroitin sulfate in accordance with USP; The sensor is not suitable for determinations of concentrations via measurement of color intensity (colorimetry).
- <p>Optical sensor for photometric titrations offering 8 different wavelengths. The wavelength can be switched using the software (tiamo 2.5 or higher) or with a magnet. The glass shaft is completely solvent-resistant and easy to clean. For example, this space-saving sensor is suitable for:</p><ul><li>Non-aqueous titrations in accordance with USP or EP</li><li>Determinations of carboxyl end groups</li><li>TAN/TBN in accordance with ASTM D974</li><li>Sulfate determination</li><li>Fe, Al, Ca in cement</li><li>Water hardness</li><li>Chondroitin sulfate in accordance with USP</li></ul><p>The sensor is not suitable for determinations of concentrations via measurement of color intensity (colorimetry).</p>
- PCS
- 1