Ion chromatography: Maintenance intervals
sk
Maintenance intervals for Metrohm ion chromatography instruments based on time, sample used or topic.
Find more information about maintenance intervals depending on the interval periods (2 months, quarterly, semi-annually, or annually), sample used, or topic (IC system, ultrafiltration, dialysis, PCR, columns, miscellaneous).
Interval – 2 months
| Description | Order number |
|---|---|
| Peristaltic pump tubing (orange/yellow) with three stoppers for MSM regeneration solution | 6.1826.420 |
| Peristaltic pump tubing (white/white) with three stoppers to pump the sample from the Sample Processor to the injection loop | 6.1826.360 |
| Peristaltic pump tubing (yellow/yellow) with three stoppers used on the sample side of the Ultrafiltration cell | 6.1826.390 |
| Peristaltic pump tubing (orange/yellow) with three stoppers used on the filtrate side of the Utlrafiltration cell | 6.1826.320 |
| Peristaltic pump tubing (black/black) with three stoppers used to pump the sample solution for dialysis | 6.1826.340 |
| Peristaltic pump tubing (orange/yellow) with three stoppers used to pump the acceptor solution for dialysis | 6.1826.320 |
| Peristaltic pump tubing (orange/green) with three stoppers used to pump the PCR reagent for the bromate determination with the triiodide method | 6.1826.310 |
Interval – Quarterly
| Description | Order number |
|---|---|
| Aspiration filter for the eluent (set of 5) |
6.2821.090 |
| Spare filter for inline filter (6.2821.120) between purge valve and pulsation absorber (set of 10) |
6.2821.130 |
| Spare filter for inline filter (6.2744.180) of the MSM | 6.2821.130 |
| Metrosep C PCC 1/4.0 | 6.1010.300 |
| Metrosep C PCC 1 HC/4.0 | 6.1010.310 |
| Metrosep C PCC 1 VHC/4.0 | 6.1010.320 |
| Metrosep I Trap 1 - 100/4.0 | 6.1014.200 |
| Metrosep A PCC 2/4.0 | 6.1006.330 |
| Metrosep A PCC 2 HC/4.0 | 6.1006.340 |
| Metrosep A PCC 2 VHC/4.0 | 6.1006.350 |
Interval – Semi-annually
| Description | Order number |
|---|---|
| 940/930/925 IC Pump Flow check |
- |
| Metrosep C Trap 1 - 100/4.0 | 6.1015.000 |
| Metrosep A Trap 1 - 100/4.0 | 6.1014.000 |
Interval – Annually
| Description | Order number |
|---|---|
| 940/930/925 IC Pump Inlet valve PEEK |
6.2824.170 |
| 940/930/925 IC Pump Outlet valve PEEK |
6.2824.160 |
| 940/930/925 IC Pump Piston seal (orange) |
6.2741.020 |
| 940/930/925 IC Pump Zirconium oxide piston |
6.2824.070 |
Complete glass cylinder unit, 50 mL, for Inline Eluent Preparation Complete glass cylinder unit, 2 mL, for Dosino Regeneration |
|
| CO2 Absorber | 6.2837.100 |
Interval – Depending on sample
| Description | Recommended maintenance interval | Order number |
|---|---|---|
| Metrosep A Supp 4/5 Guard/4.0 (example guard)* | The use of 3-4 guards per analytic column is recommended. | 6.1006.500 |
| Metrosep C 4 Guard /4.0 (example guard)* | The use of 3-4 guards per analytic column is recommended. | 6.1050.500 |
| Metrosep A Supp 5 - 150/4.0 (example column)* | 2500 injections, highly sample depending | 6.1006.520 |
| Metrosep C 4 - 150/4.0 (example column)* | 2500 injections, highly sample depending | 6.1050.420 |
| Ultrafiltration membrane (set of 50) |
>100 injections, depending on sample matrix | 6.2714.020 |
| Dialysis membrane cellulose (standard) (set of 50) |
40-400 injections, depending on sample matrix | 6.2714.010 |
| Dialysis membrane polyamide (alternative) (set of 50) |
40-400 injections, depending on sample matrix | 6.2714.030 |
| Vials PP, 11 mL (2000 pieces) | For single use | 6.2743.050 |
| Vials PP, 11 mL (200 pieces) | For single use | 6.2743.057 |
| Vials PP, 2.5 mL (2000 pieces) | For single use | 6.2743.040 |
| Vials PP, 2.5 mL (200 pieces) | For single use | 6.2743.047 |
| Stopper with perforation (2000 pieces) | For single use | 6.2743.070 |
| Stopper with perforation (200 pieces) | For single use | 6.2743.077 |
*Caution: Number of injections can vary! It is highly depending on the sample and on the care of use!
Topic – IC system
| Description | Recommended maintenance interval | Order number |
|---|---|---|
| Peristaltic pump tubing (orange/yellow) with three stoppers for MSM regeneration solution | 2 months | 6.1826.420 |
| Peristaltic pump tubing (white/white) with three stoppers to pump the sample from the Sample Processor to the injection loop | 2 months | 6.1826.360 |
| Aspiration filter for the eluent (set of 5) |
quarterly | 6.2821.090 |
| Spare filter for inline filter (6.2821.120) between purge valve and pulsation absorber (set of 10) |
quarterly | 6.2821.130 |
| Spare filter for inline filter (6.2744.180) of the MSM | quarterly | 6.2821.130 |
| 940/930/925 IC Pump Flow check |
semi-annually | - |
| 940/930/925 IC Pump Inlet valve PEEK |
annually | 6.2824.170 |
| 940/930/925 IC Pump Outlet valve PEEK |
annually | 6.2824.160 |
| 940/930/925 IC Pump Piston seal (orange) |
annually | 6.2741.020 |
| 940/930/925 IC Pump Zirconium oxide piston |
annually | 6.2824.070 |
| CO2 Absorber | annually | 6.2837.100 |
Topic – Ultrafiltration
| Description | Recommended maintenance interval | Order number |
|---|---|---|
| Peristaltic pump tubing (yellow/yellow) with three stoppers used on the sample side of the Ultrafiltration cell | 2 months | 6.1826.390 |
| Peristaltic pump tubing (orange/yellow) with three stoppers used on the filtrate side of the Utlrafiltration cell | 2 months | 6.1826.320 |
| Ultrafiltration membrane (set of 50) |
>100 injections, depending on sample matrix | 6.2714.020 |
Topic – Dialysis
| Description | Recommended maintenance interval | Order number |
|---|---|---|
| Peristaltic pump tubing (black/black) with three stoppers used to pump the sample solution for dialysis | 2 months | 6.1826.340 |
| Peristaltic pump tubing (orange/yellow) with three stoppers used to pump the acceptor solution for dialysis | 2 months | 6.1826.320 |
| Dialysis membrane cellulose (standard) (set of 50) |
40-400 injections, depending on sample matrix | 6.2714.010 |
| Dialysis membrane polyamide (alternative) (set of 50) |
40-400 injections, depending on sample matrix | 6.2714.030 |
Topic – PCR
| Description | Recommended maintenance interval | Order number |
|---|---|---|
| Peristaltic pump tubing (orange/green) with three stoppers used to pump the PCR reagent for the bromate determination with the triiodide method | 2 months | 6.1826.310 |
Topic – Columns
| Description | Recommended maintenance interval | Order number |
|---|---|---|
| Metrosep C PCC 1/4.0 | quarterly | 6.1010.300 |
| Metrosep C PCC 1 HC/4.0 | quarterly | 6.1010.310 |
| Metrosep C PCC 1 VHC/4.0 | quarterly | 6.1010.320 |
| Metrosep I Trap 1 - 100/4.0 | quarterly | 6.1014.200 |
| Metrosep A PCC 2/4.0 | quarterly | 6.1006.330 |
| Metrosep A PCC 2 HC/4.0 | quarterly | 6.1006.340 |
| Metrosep A PCC 2 VHC/4.0 | quarterly | 6.1006.350 |
| Metrosep C Trap 1 - 100/4.0 | semi-annually | 6.1015.000 |
| Metrosep A Trap 1 -100/4.0 | semi-annually | 6.1014.000 |
| Metrosep A Supp 4/5 Guard/4.0 (example guard)* | The use of 3-4 guards per analytic column is recommended. | 6.1006.500 |
| Metrosep C 4 Guard/4.0 (example guard)* | The use of 3-4 guards per analytic column is recommended. | 6.1050.500 |
| Metrosep A Supp 5 -150/4.0 (example column)* | 2500 injections, highly sample depending | 6.1006.520 |
| Metrosep C 4 -150/4.0 (example column)* | 2500 injections, highly sample depending | 6.1050.420 |
*Caution: Number of injections can vary! It is highly depending on the sample and on the care of use
Topic – Miscellaneous
| Description | Recommended maintenance interval | Order number |
|---|---|---|
Complete glass cylinder unit, 50 mL, for Inline Eluent Preparation Complete glass cylinder unit, 2 mL, for Dosino Regeneration |
annually | |
| Vials PP, 11 mL (2000 pieces) | For single-use | 6.2743.050 |
| Vials PP, 11 mL (200 pieces) | For single-use | 6.2743.057 |
| Vials PP, 2.5 mL (2000 pieces) | For single-use | 6.2743.040 |
| Vials PP, 2.5 mL (200 pieces) | For single-use | 6.2743.047 |
| Stopper with perforation (2000 pieces) | For single-use | 6.2743.070 |
| Stopper with perforation (200 pieces) | For single-use | 6.2743.077 |