Pharm Titrando
2.907.1020
Pharm Titrando
en
2.907.1020
Visão geral
The Pharm Titrando is based on the 907 Titrando and offers a complete package for the most common analyses of pharmaceutical products. Apart from the titration software tiamoTM full and determination methods described in detail, you will also receive comprehensive accessories for your titrations.
Este produto foi descontinuado, mas ainda oferecemos suporte.
-
- iAg Titrode
- 6.00470.300
- Intelligent, combined silver ring electrode with a pH glass membrane as reference electrode and integrated memory chip for storing sensor data.This maintenance-free electrode is suitable for precipitation titrations when the pH value remains constant (titrant silver nitrate), for example of: Chloride, Bromide, Iodide; Sulfides; Hydrogen sulfide; Mercaptans; Cyanides; This electrode is stored in distilled water.Depending on the application, we recommend using an Ag Titrode with Ag2S coating, which can be ordered accordingly.iTrodes can be used on Titrando, Ti-Touch or 913/914 meters.
- <p>Intelligent, combined silver ring electrode with a pH glass membrane as reference electrode and integrated memory chip for storing sensor data.<br/>This maintenance-free electrode is suitable for precipitation titrations when the pH value remains constant (titrant silver nitrate), for example of:<br/> </p><ul><li>Chloride, Bromide, Iodide</li><li>Sulfides</li><li>Hydrogen sulfide</li><li>Mercaptans</li><li>Cyanides</li></ul><p><br/>This electrode is stored in distilled water.<br/><br/>Depending on the application, we recommend using an Ag Titrode with Ag<sub>2</sub>S coating, which can be ordered accordingly.<br/>iTrodes can be used on Titrando, Ti-Touch or 913/914 meters.</p>
- PCS
- 1
- iAquatrode Plus with Pt1000
- 6.0277.300
- Intelligent, combined pH electrode with integrated memory chip for storing sensor data and with Pt1000 temperature sensor for pH measurements/titrations in ion-deficient aqueous media (e.g., drinking water, process water). This electrode shows a very short response time in these samples. The fixed ground-joint diaphragm is insensitive to contamination. When c(KCl) = 3 mol/L is used as bridge electrolyte, storage in storage solution is recommended.The bridge electrolyte can be easily replaced with a chloride-free electrolyte (e.g., potassium nitrate c(KNO3) = 1 mol/L (6.2310.010)). Storage in the used bridge electrolyte.iTrodes can be connected to Titrando, Ti-Touch, or 913/914 meters.
- <p>Intelligent, combined pH electrode with integrated memory chip for storing sensor data and with Pt1000 temperature sensor for pH measurements/titrations in ion-deficient aqueous media (e.g., drinking water, process water). This electrode shows a very short response time in these samples. <br/><br/>The fixed ground-joint diaphragm is insensitive to contamination. <br/>When c(KCl) = 3 mol/L is used as bridge electrolyte, storage in storage solution is recommended.<br/>The bridge electrolyte can be easily replaced with a chloride-free electrolyte (e.g., potassium nitrate c(KNO<sub>3</sub>) = 1 mol/L (6.2310.010)). Storage in the used bridge electrolyte.<br/>iTrodes can be connected to Titrando, Ti-Touch, or 913/914 meters.</p>
- PCS
- 1
- iSolvotrode
- 6.0279.300
- Intelligent, combined pH electrode with integrated memory chip for storing sensor data for all non-aqueous acid/base titrations. The glass membrane is optimized for poorly conducting solutions, and thanks to the flexible ground-joint diaphragm, the electrode is well suited for contaminated samples. This electrode can be used with non-aqueous reference electrolytes (lithium chloride or tetraethylammonium bromide). Storage in the respective reference electrolyte.iTrodes can be connected to Titrando, Ti-Touch, or 913/914 meters.
- <p>Intelligent, combined pH electrode with integrated memory chip for storing sensor data for all non-aqueous acid/base titrations. <br/>The glass membrane is optimized for poorly conducting solutions, and thanks to the flexible ground-joint diaphragm, the electrode is well suited for contaminated samples. This electrode can be used with non-aqueous reference electrolytes (lithium chloride or tetraethylammonium bromide). Storage in the respective reference electrolyte.<br/>iTrodes can be connected to Titrando, Ti-Touch, or 913/914 meters.</p>
- PCS
- 1
- iPt Titrode
- 6.0471.300
- Combined platinum ring electrode with a pH glass membrane as reference electrode and integrated memory chip for storing sensor data.This maintenance-free electrode is suitable for redox titrations when the pH value remains constant, e.g.: Iodometry; Chromatometry; Cerimetry; Permanganometry; This electrode is stored in distilled water.iTrodes can be used on Titrando, Ti-Touch oder 913/914 meters.
- <p>Combined platinum ring electrode with a pH glass membrane as reference electrode and integrated memory chip for storing sensor data.<br/>This maintenance-free electrode is suitable for redox titrations when the pH value remains constant, e.g.:<br/> </p><ul><li>Iodometry</li><li>Chromatometry</li><li>Cerimetry</li><li>Permanganometry</li></ul><p><br/>This electrode is stored in distilled water.<br/>iTrodes can be used on Titrando, Ti-Touch oder 913/914 meters.</p>
- PCS
- 1
- Optrode
- 6.1115.000
- Optical sensor for photometric titrations offering 8 different wavelengths. The wavelength can be switched using the software (tiamo 2.5 or higher) or with a magnet. The glass shaft is completely solvent-resistant and easy to clean. For example, this space-saving sensor is suitable for:Non-aqueous titrations in accordance with USP or EP; Determinations of carboxyl end groups; TAN/TBN in accordance with ASTM D974; Sulfate determination; Fe, Al, Ca in cement; Water hardness; Chondroitin sulfate in accordance with USP; The sensor is not suitable for determinations of concentrations via measurement of color intensity (colorimetry).
- <p>Optical sensor for photometric titrations offering 8 different wavelengths. The wavelength can be switched using the software (tiamo 2.5 or higher) or with a magnet. The glass shaft is completely solvent-resistant and easy to clean. For example, this space-saving sensor is suitable for:</p><ul><li>Non-aqueous titrations in accordance with USP or EP</li><li>Determinations of carboxyl end groups</li><li>TAN/TBN in accordance with ASTM D974</li><li>Sulfate determination</li><li>Fe, Al, Ca in cement</li><li>Water hardness</li><li>Chondroitin sulfate in accordance with USP</li></ul><p>The sensor is not suitable for determinations of concentrations via measurement of color intensity (colorimetry).</p>
- PCS
- 1
- Piston tongs
- 6.1546.030
- For pistons for 807 Dosing Units or cylinder units OMNIS.
- <p>For pistons for 807 Dosing Units or cylinder units OMNIS.</p>
- PCS
- 1
- Amber glass bottle / 1000 mL / GL 45
- 6.1608.023
- For Exchange Units. Bottle for auxiliary solutions.
- For Exchange Units. Bottle for auxiliary solutions.
- PCS
- 2
- Stirring propeller / 87 mm
- 6.1909.010
- Propeller stirrer, length from lower edge of SGJ: 96 mm. For use with beakers with 722, 802 Rod Stirrer
- <p>Propeller stirrer, length from lower edge of SGJ: 96 mm. For use with beakers with 722, 802 Rod Stirrer</p>
- PCS
- 1
- Support stand without support rod
- 6.2001.060
- To attach an 801, 804, 803 Stirrer to a Titrando, Titrino plus, Dosimat plus or 856 and 867.
- To attach an 801, 804, 803 Stirrer to a Titrando, Titrino plus, Dosimat plus or 856 and 867.
- PCS
- 1
- Clamping ring
- 6.2013.010
- For support rods with a diameter of 10 mm.
- <p>For support rods with a diameter of 10 mm.</p>
- PCS
- 1
- Support rod / 400 mm
- 6.2016.070
- PCS
- 1
- Electrode holder
- 6.2021.020
- Electrode holder for 4 electrodes and 2 buret tips
- Electrode holder for 4 electrodes and 2 buret tips
- PCS
- 1
- Holding clip for bottles
- 6.2043.005
- Holding spring for reagent bottles in exchange units.
- <p>Holding spring for reagent bottles in exchange units.</p>
- PCS
- 2
- Electrode cable / 1 m / F
- 6.2104.020
- For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
- For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
- PCS
- 1
- Cable USB A – mini-DIN 8-pin
- 6.2151.000
- Controller cable
- Controller cable
- PCS
- 1
- Buffer solutions pH 4, 7 and 9
- 6.2307.230
- Mixed buffer solutions pH 4.00/7.00/9.00 (25 °C) in single use sachets, colourless, box of 3 x 10 x 30 mL
- Mixed buffer solutions pH 4.00/7.00/9.00 (25 °C) in single use sachets, colourless, box of 3 x 10 x 30 mL
- PCS
- 1
- Electrolyte 3 mol/L KCl (50 mL)
- 6.2308.050
- Electrolyte solution c(KCl) = 3 mol/L (for Ag/AgCl reference systems)
- Electrolyte solution c(KCl) = 3 mol/L (for Ag/AgCl reference systems)
- PCS
- 1
- TEABr 0.4 mol/L in ethylene glycol (250 mL)
- 6.2320.000
- Electrolyte solution TEABr (tetraethylammonium bromide in ethylene glycol), c(TEABr) = 0.4 mol/L
- Electrolyte solution TEABr (tetraethylammonium bromide in ethylene glycol), c(TEABr) = 0.4 mol/L
- PCS
- 1
- Storage solution
- 6.2323.000
- Storage solution for all combined pH glass electrodes with reference electrolyte c(KCl) = 3 mol/L
- Storage solution for all combined pH glass electrodes with reference electrolyte c(KCl) = 3 mol/L
- PCS
- 1
- 5 mm hex key for IC Sample Processors
- 6.2621.070
- PCS
- 1
- Hexagon key 2 mm
- 6.2621.130
- 2 mm.
- 2 mm.
- PCS
- 1
- 807 Dosing Unit 20 mL
- 6.3032.220
- 807 Dosing Unit with integrated data chip with 20 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.
- <p>807 Dosing Unit with integrated data chip with 20 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.</p>
- PCS
- 2
-
- 800 Dosino (cable length 1.5 m)
- 1.800.0030
- Drive with write/read hardware for intelligent dosing units. With permanently attached cable (length 1.5 m).
- <p>Drive with write/read hardware for intelligent dosing units. With permanently attached cable (length 1.5 m).</p>
- PCS
- 2
- 802 Rod Stirrer for 727 Ti Stand
- 1.802.0010
- Rod stirrer with separate 6.2137.000 Speed controller and 6.1909.010 Propeller stirrer.
- Rod stirrer with separate 6.2137.000 Speed controller and 6.1909.010 Propeller stirrer.
- PCS
- 1
- 804 Ti Stand without stand rod
- 1.804.0010
- Titration stand and controller for 802 Stirrer. The 804 Ti Stand together with the optional 802 Stirrer provides an alternative to the magnetic stirrer. Without stand.
- Titration stand and controller for 802 Stirrer. The 804 Ti Stand together with the optional 802 Stirrer provides an alternative to the magnetic stirrer. Without stand.
- PCS
- 1
- 854 iConnect
- 1.854.0010
- 854 iConnect - electrode cable and measuring amplifier for intelligent electrodes «iTrodes».
- <p>854 iConnect - electrode cable and measuring amplifier for intelligent electrodes «iTrodes».</p>
- PCS
- 2
- 907 Titrando
- 1.907.0020
- High-end titrator for use with intelligent electrodes – iTrodes – withup to four dosing systems of the 800 Dosino type; dynamic (DET), monotonic (MET) and endpoint titration (SET), enzymatic and pH-STAT titrations (STAT), Karl Fischer titration (KFT); Measurement with ion-selective electrodes (MEAS CONC); Dosing functions with monitoring (DOS), Liquid Handling; four MSB connectors; two galvanically isolated measuring interfaces; USB connector;
- <p>High-end titrator for use with intelligent electrodes – iTrodes – with</p><ul><li>up to four dosing systems of the 800 Dosino type</li><li>dynamic (DET), monotonic (MET) and endpoint titration (SET), enzymatic and pH-STAT titrations (STAT), Karl Fischer titration (KFT)</li><li>Measurement with ion-selective electrodes (MEAS CONC)</li><li>Dosing functions with monitoring (DOS), Liquid Handling</li><li>four MSB connectors</li><li><strong>two galvanically isolated measuring interfaces</strong></li><li>USB connector</li></ul>
- PCS
- 1
- iAg Titrode
- 6.00470.300
- Intelligent, combined silver ring electrode with a pH glass membrane as reference electrode and integrated memory chip for storing sensor data.This maintenance-free electrode is suitable for precipitation titrations when the pH value remains constant (titrant silver nitrate), for example of: Chloride, Bromide, Iodide; Sulfides; Hydrogen sulfide; Mercaptans; Cyanides; This electrode is stored in distilled water.Depending on the application, we recommend using an Ag Titrode with Ag2S coating, which can be ordered accordingly.iTrodes can be used on Titrando, Ti-Touch or 913/914 meters.
- <p>Intelligent, combined silver ring electrode with a pH glass membrane as reference electrode and integrated memory chip for storing sensor data.<br/>This maintenance-free electrode is suitable for precipitation titrations when the pH value remains constant (titrant silver nitrate), for example of:<br/> </p><ul><li>Chloride, Bromide, Iodide</li><li>Sulfides</li><li>Hydrogen sulfide</li><li>Mercaptans</li><li>Cyanides</li></ul><p><br/>This electrode is stored in distilled water.<br/><br/>Depending on the application, we recommend using an Ag Titrode with Ag<sub>2</sub>S coating, which can be ordered accordingly.<br/>iTrodes can be used on Titrando, Ti-Touch or 913/914 meters.</p>
- PCS
- 1
- iAquatrode Plus with Pt1000
- 6.0277.300
- Intelligent, combined pH electrode with integrated memory chip for storing sensor data and with Pt1000 temperature sensor for pH measurements/titrations in ion-deficient aqueous media (e.g., drinking water, process water). This electrode shows a very short response time in these samples. The fixed ground-joint diaphragm is insensitive to contamination. When c(KCl) = 3 mol/L is used as bridge electrolyte, storage in storage solution is recommended.The bridge electrolyte can be easily replaced with a chloride-free electrolyte (e.g., potassium nitrate c(KNO3) = 1 mol/L (6.2310.010)). Storage in the used bridge electrolyte.iTrodes can be connected to Titrando, Ti-Touch, or 913/914 meters.
- <p>Intelligent, combined pH electrode with integrated memory chip for storing sensor data and with Pt1000 temperature sensor for pH measurements/titrations in ion-deficient aqueous media (e.g., drinking water, process water). This electrode shows a very short response time in these samples. <br/><br/>The fixed ground-joint diaphragm is insensitive to contamination. <br/>When c(KCl) = 3 mol/L is used as bridge electrolyte, storage in storage solution is recommended.<br/>The bridge electrolyte can be easily replaced with a chloride-free electrolyte (e.g., potassium nitrate c(KNO<sub>3</sub>) = 1 mol/L (6.2310.010)). Storage in the used bridge electrolyte.<br/>iTrodes can be connected to Titrando, Ti-Touch, or 913/914 meters.</p>
- PCS
- 1
- iSolvotrode
- 6.0279.300
- Intelligent, combined pH electrode with integrated memory chip for storing sensor data for all non-aqueous acid/base titrations. The glass membrane is optimized for poorly conducting solutions, and thanks to the flexible ground-joint diaphragm, the electrode is well suited for contaminated samples. This electrode can be used with non-aqueous reference electrolytes (lithium chloride or tetraethylammonium bromide). Storage in the respective reference electrolyte.iTrodes can be connected to Titrando, Ti-Touch, or 913/914 meters.
- <p>Intelligent, combined pH electrode with integrated memory chip for storing sensor data for all non-aqueous acid/base titrations. <br/>The glass membrane is optimized for poorly conducting solutions, and thanks to the flexible ground-joint diaphragm, the electrode is well suited for contaminated samples. This electrode can be used with non-aqueous reference electrolytes (lithium chloride or tetraethylammonium bromide). Storage in the respective reference electrolyte.<br/>iTrodes can be connected to Titrando, Ti-Touch, or 913/914 meters.</p>
- PCS
- 1
- iPt Titrode
- 6.0471.300
- Combined platinum ring electrode with a pH glass membrane as reference electrode and integrated memory chip for storing sensor data.This maintenance-free electrode is suitable for redox titrations when the pH value remains constant, e.g.: Iodometry; Chromatometry; Cerimetry; Permanganometry; This electrode is stored in distilled water.iTrodes can be used on Titrando, Ti-Touch oder 913/914 meters.
- <p>Combined platinum ring electrode with a pH glass membrane as reference electrode and integrated memory chip for storing sensor data.<br/>This maintenance-free electrode is suitable for redox titrations when the pH value remains constant, e.g.:<br/> </p><ul><li>Iodometry</li><li>Chromatometry</li><li>Cerimetry</li><li>Permanganometry</li></ul><p><br/>This electrode is stored in distilled water.<br/>iTrodes can be used on Titrando, Ti-Touch oder 913/914 meters.</p>
- PCS
- 1
- Optrode
- 6.1115.000
- Optical sensor for photometric titrations offering 8 different wavelengths. The wavelength can be switched using the software (tiamo 2.5 or higher) or with a magnet. The glass shaft is completely solvent-resistant and easy to clean. For example, this space-saving sensor is suitable for:Non-aqueous titrations in accordance with USP or EP; Determinations of carboxyl end groups; TAN/TBN in accordance with ASTM D974; Sulfate determination; Fe, Al, Ca in cement; Water hardness; Chondroitin sulfate in accordance with USP; The sensor is not suitable for determinations of concentrations via measurement of color intensity (colorimetry).
- <p>Optical sensor for photometric titrations offering 8 different wavelengths. The wavelength can be switched using the software (tiamo 2.5 or higher) or with a magnet. The glass shaft is completely solvent-resistant and easy to clean. For example, this space-saving sensor is suitable for:</p><ul><li>Non-aqueous titrations in accordance with USP or EP</li><li>Determinations of carboxyl end groups</li><li>TAN/TBN in accordance with ASTM D974</li><li>Sulfate determination</li><li>Fe, Al, Ca in cement</li><li>Water hardness</li><li>Chondroitin sulfate in accordance with USP</li></ul><p>The sensor is not suitable for determinations of concentrations via measurement of color intensity (colorimetry).</p>
- PCS
- 1
- Piston tongs
- 6.1546.030
- For pistons for 807 Dosing Units or cylinder units OMNIS.
- <p>For pistons for 807 Dosing Units or cylinder units OMNIS.</p>
- PCS
- 1
- Amber glass bottle / 1000 mL / GL 45
- 6.1608.023
- For Exchange Units. Bottle for auxiliary solutions.
- For Exchange Units. Bottle for auxiliary solutions.
- PCS
- 2
- Stirring propeller / 87 mm
- 6.1909.010
- Propeller stirrer, length from lower edge of SGJ: 96 mm. For use with beakers with 722, 802 Rod Stirrer
- <p>Propeller stirrer, length from lower edge of SGJ: 96 mm. For use with beakers with 722, 802 Rod Stirrer</p>
- PCS
- 1
- Support stand without support rod
- 6.2001.060
- To attach an 801, 804, 803 Stirrer to a Titrando, Titrino plus, Dosimat plus or 856 and 867.
- To attach an 801, 804, 803 Stirrer to a Titrando, Titrino plus, Dosimat plus or 856 and 867.
- PCS
- 1
- Clamping ring
- 6.2013.010
- For support rods with a diameter of 10 mm.
- <p>For support rods with a diameter of 10 mm.</p>
- PCS
- 1
- Support rod / 400 mm
- 6.2016.070
- PCS
- 1
- Electrode holder
- 6.2021.020
- Electrode holder for 4 electrodes and 2 buret tips
- Electrode holder for 4 electrodes and 2 buret tips
- PCS
- 1
- Holding clip for bottles
- 6.2043.005
- Holding spring for reagent bottles in exchange units.
- <p>Holding spring for reagent bottles in exchange units.</p>
- PCS
- 2
- Electrode cable / 1 m / F
- 6.2104.020
- For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
- For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
- PCS
- 1
- Cable USB A – mini-DIN 8-pin
- 6.2151.000
- Controller cable
- Controller cable
- PCS
- 1
- Buffer solutions pH 4, 7 and 9
- 6.2307.230
- Mixed buffer solutions pH 4.00/7.00/9.00 (25 °C) in single use sachets, colourless, box of 3 x 10 x 30 mL
- Mixed buffer solutions pH 4.00/7.00/9.00 (25 °C) in single use sachets, colourless, box of 3 x 10 x 30 mL
- PCS
- 1
- Electrolyte 3 mol/L KCl (50 mL)
- 6.2308.050
- Electrolyte solution c(KCl) = 3 mol/L (for Ag/AgCl reference systems)
- Electrolyte solution c(KCl) = 3 mol/L (for Ag/AgCl reference systems)
- PCS
- 1
- TEABr 0.4 mol/L in ethylene glycol (250 mL)
- 6.2320.000
- Electrolyte solution TEABr (tetraethylammonium bromide in ethylene glycol), c(TEABr) = 0.4 mol/L
- Electrolyte solution TEABr (tetraethylammonium bromide in ethylene glycol), c(TEABr) = 0.4 mol/L
- PCS
- 1
- Storage solution
- 6.2323.000
- Storage solution for all combined pH glass electrodes with reference electrolyte c(KCl) = 3 mol/L
- Storage solution for all combined pH glass electrodes with reference electrolyte c(KCl) = 3 mol/L
- PCS
- 1
- 5 mm hex key for IC Sample Processors
- 6.2621.070
- PCS
- 1
- Hexagon key 2 mm
- 6.2621.130
- 2 mm.
- 2 mm.
- PCS
- 1
- 807 Dosing Unit 20 mL
- 6.3032.220
- 807 Dosing Unit with integrated data chip with 20 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.
- <p>807 Dosing Unit with integrated data chip with 20 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.</p>
- PCS
- 2
-
- Adapter red 2 mm plug / 4 mm socket
- 6.2103.130
- For connecting plug B (4 mm) to 2 mm socket.
- For connecting plug B (4 mm) to 2 mm socket.
- PCS
- 1
- Adapter black 2 mm plug / B socket 4 mm
- 6.2103.140
- For connecting plug B (4 mm) to 2 mm socket.
- For connecting plug B (4 mm) to 2 mm socket.
- PCS
- 1