Pharm Titrando
2.907.1020
Pharm Titrando
en
2.907.1020
Visão geral
The Pharm Titrando is based on the 907 Titrando and offers a complete package for the most common analyses of pharmaceutical products. Apart from the titration software tiamoTM full and determination methods described in detail, you will also receive comprehensive accessories for your titrations.
Este produto foi descontinuado, mas ainda é suportado.
Product Family
- title
- Titrando
- description
- Desde Tituladores automáticos a uma solução totalmente automatizada em uma rede diversificada: um titulador Potenciométrico que pode ser adaptado às suas necessidades.
Documents
-
89045001
-
de
- title
- Prospekt: 904/905 und 906/907 Titrando
- description
- Titrieren heisst doch: intelligent dosieren. Mit dem Titrando-System haben Sie die Wahl. Beim 905 und 907 Titrando dosieren Sie mit Dosinos und Dosiereinheiten, die direkt auf die Reagenzflaschen aufgeschraubt werden. Beim 904 und 906 Titrando erfolgt die Dosierung mit Wechseleinheiten. Eine davon befindet sich auf dem 904 oder 906 Titrando, der zusätzliche Dosimaten mit weiteren Wechseleinheiten steuern kann. Gemischte Systeme mit Dosier- und Wechseleinheiten sind durchaus möglich. Ihre Wahl bedeutet also keine Einbahnstrasse, die Flexibilität bleibt voll gewahrt.
- language
- de
- documentpath
- /content/metrohm/shared/de/products/8/9045/89045001
-
en
- title
- Brochure: 904/905 and 906/907 Titrando
- description
- Titrating means dosing intelligently. The Titrando System gives you the choice. With the 905 and 907 Titrando you dose with Dosinos and Dosing Units that are attached directly onto the reagent bottle. With the 904 and 906 Titrando dosing is carried out by using Exchange Units. One of these is located on the 904 or 906 Titrando, which can control additional Dosimats with their Exchange Units. Mixed systems with Dosing and Exchange Units are possible. This means that your choice doesnt lead you down a blind alley - full flexibility is retained.
- language
- en
- documentpath
- /content/metrohm/shared/en/products/8/9045/89045001
-
es
- title
- Folleto: 904/905 Titrando y 906/907 Titrando
- description
- Valoración inteligente significa dosificación inteligente. Con el sistema Titrando, usted elige la forma de dosificación. En el 905 Titrando y el 907 Titrando, usted dosifica con aparatos Dosino y unidades de dosificación que puede enroscar directamente en las botellas de reactivo. En el 904 Titrando y en el 906 Titrando, se usan unidades intercambiables. Una de ellas se encuentra en el 904 Titrando o 906 Titrando, el cual puede controlar Dosimat adicionales equipados con otras unidades intercambiables. También son posibles sistemas mixtos con unidades dosificadoras y unidades intercambiables. Usted puede elegir con una total flexibilidad.
- language
- es
- documentpath
- /content/metrohm/shared/es/products/8/9045/89045001
-
vi
- title
- Brochure: 904/905 and 906/907 Titrando
- description
- Titrating means dosing intelligently. The Titrando System gives you the choice. With the 905 and 907 Titrando you dose with Dosinos and Dosing Units that are attached directly onto the reagent bottle. With the 904 and 906 Titrando dosing is carried out by using Exchange Units. One of these is located on the 904 or 906 Titrando, which can control additional Dosimats with their Exchange Units. Mixed systems with Dosing and Exchange Units are possible. This means that your choice doesnt lead you down a blind alley - full flexibility is retained.
- language
- vi
- documentpath
- /content/metrohm/shared/vi/products/8/9045/89045001
-
de
-
89073001
-
de
- title
- Konformitätserklärung 907 Titrando
- description
- EU-Konformitätserklärung / UK-Konformitätserklärung 907 Titrando
- language
- de
- documentpath
- /content/metrohm/shared/de/products/8/9073/89073001
-
en
- title
- Declaration of conformity 907 Titrando
- description
- EU declaration of conformity / UK declaration of conformity 907 Titrando
- language
- en
- documentpath
- /content/metrohm/shared/en/products/8/9073/89073001
-
fr
- title
- Déclaration de conformité 907 Titrando
- description
- Déclaration UE de conformité/déclaration de conformité du Royaume-Uni 907 Titrando
- language
- fr
- documentpath
- /content/metrohm/shared/fr/products/8/9073/89073001
-
ja
- title
- 適合宣言 907 Titrando
- description
- EU 適合宣言 / UK 適合宣言 907 Titrando
- language
- ja
- documentpath
- /content/metrohm/shared/ja/products/8/9073/89073001
-
es
- title
- Declaración de conformidad para el 907 Titrando
- description
- Declaración UE de conformidad / Declaración de conformidad del Reino Unido para el 907 Titrando
- language
- es
- documentpath
- /content/metrohm/shared/es/products/8/9073/89073001
-
zh
- title
- 907 Titrando 一致性声明
- description
- 907 Titrando 欧盟一致性声明/ 英国一致性声明
- language
- zh
- documentpath
- /content/metrohm/shared/zh/products/8/9073/89073001
-
pt
- title
- Declaration of conformity 907 Titrando
- description
- language
- pt
- documentpath
- /content/metrohm/shared/pt/products/8/9073/89073001
-
vi
- title
- Declaration of conformity 907 Titrando
- description
- EU declaration of conformity / UK declaration of conformity 907 Titrando
- language
- vi
- documentpath
- /content/metrohm/shared/vi/products/8/9073/89073001
-
ko
- title
- EU declaration of conformity 907 Titrando
- description
- language
- ko
- documentpath
- /content/metrohm/shared/ko/products/8/9073/89073001
-
de
-
89078003
-
de
- title
- Handbuch 907 Titrando
- description
- language
- de
- documentpath
- /content/metrohm/shared/de/products/8/9078/89078003
-
en
- title
- Manual for 907 Titrando
- description
- language
- en
- documentpath
- /content/metrohm/shared/en/products/8/9078/89078003
-
fr
- title
- Mode d’emploi 907 Titrando
- description
- language
- fr
- documentpath
- /content/metrohm/shared/fr/products/8/9078/89078003
-
es
- title
- Manual 907 Titrando
- description
- language
- es
- documentpath
- /content/metrohm/shared/es/products/8/9078/89078003
-
zh
- title
- 907 Titrando 手册
- description
- language
- zh
- documentpath
- /content/metrohm/shared/zh/products/8/9078/89078003
-
vi
- title
- Manual for 907 Titrando
- description
- language
- vi
- documentpath
- /content/metrohm/shared/vi/products/8/9078/89078003
-
ko
- title
- Manual for 907 Titrando
- description
- language
- ko
- documentpath
- /content/metrohm/shared/ko/products/8/9078/89078003
-
de
-
88568006
-
en
- title
- Release Notes for various instruments, USB 3.0 compatibility
- description
- language
- en
- documentpath
- /content/metrohm/shared/en/products/8/8568/88568006
-
vi
- title
- Release Notes for various instruments, USB 3.0 compatibility
- description
- language
- vi
- documentpath
- /content/metrohm/shared/vi/products/8/8568/88568006
-
en
-
- iAquatrode Plus with Pt1000
- 6.0277.300
- Intelligent, combined pH electrode with integrated memory chip for storing sensor data and with Pt1000 temperature sensor for pH measurements/titrations in ion-deficient aqueous media (e.g., drinking water, process water). This electrode shows a very short response time in these samples. The fixed ground-joint diaphragm is insensitive to contamination. When c(KCl) = 3 mol/L is used as bridge electrolyte, storage in storage solution is recommended.The bridge electrolyte can be easily replaced with a chloride-free electrolyte (e.g., potassium nitrate c(KNO3) = 1 mol/L (6.2310.010)). Storage in the used bridge electrolyte.iTrodes can be connected to Titrando, Ti-Touch, or 913/914 meters.
- <p>Intelligent, combined pH electrode with integrated memory chip for storing sensor data and with Pt1000 temperature sensor for pH measurements/titrations in ion-deficient aqueous media (e.g., drinking water, process water). This electrode shows a very short response time in these samples. <br/><br/>The fixed ground-joint diaphragm is insensitive to contamination. <br/>When c(KCl) = 3 mol/L is used as bridge electrolyte, storage in storage solution is recommended.<br/>The bridge electrolyte can be easily replaced with a chloride-free electrolyte (e.g., potassium nitrate c(KNO<sub>3</sub>) = 1 mol/L (6.2310.010)). Storage in the used bridge electrolyte.<br/>iTrodes can be connected to Titrando, Ti-Touch, or 913/914 meters.</p>
- PCS
- 1
- iSolvotrode
- 6.0279.300
- Intelligent, combined pH electrode with integrated memory chip for storing sensor data for all non-aqueous acid/base titrations. The glass membrane is optimized for poorly conducting solutions, and thanks to the flexible ground-joint diaphragm, the electrode is well suited for contaminated samples. This electrode can be used with non-aqueous reference electrolytes (lithium chloride or tetraethylammonium bromide). Storage in the respective reference electrolyte.iTrodes can be connected to Titrando, Ti-Touch, or 913/914 meters.
- <p>Intelligent, combined pH electrode with integrated memory chip for storing sensor data for all non-aqueous acid/base titrations. <br/>The glass membrane is optimized for poorly conducting solutions, and thanks to the flexible ground-joint diaphragm, the electrode is well suited for contaminated samples. This electrode can be used with non-aqueous reference electrolytes (lithium chloride or tetraethylammonium bromide). Storage in the respective reference electrolyte.<br/>iTrodes can be connected to Titrando, Ti-Touch, or 913/914 meters.</p>
- PCS
- 1
- iPt Titrode
- 6.0471.300
- Combined platinum ring electrode with a pH glass membrane as reference electrode and integrated memory chip for storing sensor data.This maintenance-free electrode is suitable for redox titrations when the pH value remains constant, e.g.: Iodometry; Chromatometry; Cerimetry; Permanganometry; This electrode is stored in distilled water.iTrodes can be used on Titrando, Ti-Touch oder 913/914 meters.
- <p>Combined platinum ring electrode with a pH glass membrane as reference electrode and integrated memory chip for storing sensor data.<br/>This maintenance-free electrode is suitable for redox titrations when the pH value remains constant, e.g.:<br/> </p><ul><li>Iodometry</li><li>Chromatometry</li><li>Cerimetry</li><li>Permanganometry</li></ul><p><br/>This electrode is stored in distilled water.<br/>iTrodes can be used on Titrando, Ti-Touch oder 913/914 meters.</p>
- PCS
- 1
- Piston tongs
- 6.1546.030
- For pistons for 807 Dosing Units or cylinder units OMNIS.
- <p>For pistons for 807 Dosing Units or cylinder units OMNIS.</p>
- PCS
- 1
- Amber glass bottle / 1000 mL / GL 45
- 6.1608.023
- For Exchange Units. Bottle for auxiliary solutions.
- For Exchange Units. Bottle for auxiliary solutions.
- PCS
- 2
- Stirring propeller / 87 mm
- 6.1909.010
- Propeller stirrer, length from lower edge of SGJ: 96 mm. For use with beakers with 722, 802 Rod Stirrer
- <p>Propeller stirrer, length from lower edge of SGJ: 96 mm. For use with beakers with 722, 802 Rod Stirrer</p>
- PCS
- 1
- Support stand without support rod
- 6.2001.060
- To attach an 801, 804, 803 Stirrer to a Titrando, Titrino plus, Dosimat plus or 856 and 867.
- To attach an 801, 804, 803 Stirrer to a Titrando, Titrino plus, Dosimat plus or 856 and 867.
- PCS
- 1
- Clamping ring
- 6.2013.010
- For support rods with a diameter of 10 mm.
- <p>For support rods with a diameter of 10 mm.</p>
- PCS
- 1
- Support rod / 400 mm
- 6.2016.070
- PCS
- 1
- Electrode holder
- 6.2021.020
- Electrode holder for 4 electrodes and 2 buret tips
- Electrode holder for 4 electrodes and 2 buret tips
- PCS
- 1
- Holding clip for bottles
- 6.2043.005
- Holding spring for reagent bottles in exchange units.
- <p>Holding spring for reagent bottles in exchange units.</p>
- PCS
- 2
- Electrode cable / 1 m / F
- 6.2104.020
- For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
- For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
- PCS
- 1
- Cable USB A – mini-DIN 8-pin
- 6.2151.000
- Controller cable
- Controller cable
- PCS
- 1
- Buffer solutions pH 4, 7 and 9
- 6.2307.230
- Mixed buffer solutions pH 4.00/7.00/9.00 (25 °C) in single use sachets, colourless, box of 3 x 10 x 30 mL
- Mixed buffer solutions pH 4.00/7.00/9.00 (25 °C) in single use sachets, colourless, box of 3 x 10 x 30 mL
- PCS
- 1
- Electrolyte 3 mol/L KCl (50 mL)
- 6.2308.050
- Electrolyte solution c(KCl) = 3 mol/L (for Ag/AgCl reference systems)
- Electrolyte solution c(KCl) = 3 mol/L (for Ag/AgCl reference systems)
- PCS
- 1
- TEABr 0.4 mol/L in ethylene glycol (250 mL)
- 6.2320.000
- Electrolyte solution TEABr (tetraethylammonium bromide in ethylene glycol), c(TEABr) = 0.4 mol/L
- Electrolyte solution TEABr (tetraethylammonium bromide in ethylene glycol), c(TEABr) = 0.4 mol/L
- PCS
- 1
- Storage solution
- 6.2323.000
- Storage solution for all combined pH glass electrodes with reference electrolyte c(KCl) = 3 mol/L
- Storage solution for all combined pH glass electrodes with reference electrolyte c(KCl) = 3 mol/L
- PCS
- 1
- 5 mm hex key for IC Sample Processors
- 6.2621.070
- PCS
- 1
- Hexagon key 2 mm
- 6.2621.130
- 2 mm.
- 2 mm.
- PCS
- 1
- 807 Dosing Unit 20 mL
- 6.3032.220
- 807 Dosing Unit with integrated data chip with 20 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.
- <p>807 Dosing Unit with integrated data chip with 20 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.</p>
- PCS
- 2
- iAg Titrode
- 6.00470.300
- Intelligent, combined silver ring electrode with a pH glass membrane as reference electrode and integrated memory chip for storing sensor data.This maintenance-free electrode is suitable for precipitation titrations when the pH value remains constant (titrant silver nitrate), for example of: Chloride, Bromide, Iodide; Sulfides; Hydrogen sulfide; Mercaptans; Cyanides; This electrode is stored in distilled water.Depending on the application, we recommend using an Ag Titrode with Ag2S coating, which can be ordered accordingly.iTrodes can be used on Titrando, Ti-Touch or 913/914 meters.
- <p>Intelligent, combined silver ring electrode with a pH glass membrane as reference electrode and integrated memory chip for storing sensor data.<br/>This maintenance-free electrode is suitable for precipitation titrations when the pH value remains constant (titrant silver nitrate), for example of:<br/> </p><ul><li>Chloride, Bromide, Iodide</li><li>Sulfides</li><li>Hydrogen sulfide</li><li>Mercaptans</li><li>Cyanides</li></ul><p><br/>This electrode is stored in distilled water.<br/><br/>Depending on the application, we recommend using an Ag Titrode with Ag<sub>2</sub>S coating, which can be ordered accordingly.<br/>iTrodes can be used on Titrando, Ti-Touch or 913/914 meters.</p>
- PCS
- 1
-
- 802 Rod Stirrer for 727 Ti Stand
- 1.802.0010
- Rod stirrer with separate 6.2137.000 Speed controller and 6.1909.010 Propeller stirrer.
- Rod stirrer with separate 6.2137.000 Speed controller and 6.1909.010 Propeller stirrer.
- PCS
- 1
- 804 Ti Stand without stand rod
- 1.804.0010
- Titration stand and controller for 802 Stirrer. The 804 Ti Stand together with the optional 802 Stirrer provides an alternative to the magnetic stirrer. Without stand.
- Titration stand and controller for 802 Stirrer. The 804 Ti Stand together with the optional 802 Stirrer provides an alternative to the magnetic stirrer. Without stand.
- PCS
- 1
- 854 iConnect
- 1.854.0010
- 854 iConnect - electrode cable and measuring amplifier for intelligent electrodes «iTrodes».
- <p>854 iConnect - electrode cable and measuring amplifier for intelligent electrodes «iTrodes».</p>
- PCS
- 2
- 907 Titrando
- 1.907.0020
- High-end titrator for use with intelligent electrodes – iTrodes – withup to four dosing systems of the 800 Dosino type; dynamic (DET), monotonic (MET) and endpoint titration (SET), enzymatic and pH-STAT titrations (STAT), Karl Fischer titration (KFT); Measurement with ion-selective electrodes (MEAS CONC); Dosing functions with monitoring (DOS), Liquid Handling; four MSB connectors; two galvanically isolated measuring interfaces; USB connector;
- <p>High-end titrator for use with intelligent electrodes – iTrodes – with</p><ul><li>up to four dosing systems of the 800 Dosino type</li><li>dynamic (DET), monotonic (MET) and endpoint titration (SET), enzymatic and pH-STAT titrations (STAT), Karl Fischer titration (KFT)</li><li>Measurement with ion-selective electrodes (MEAS CONC)</li><li>Dosing functions with monitoring (DOS), Liquid Handling</li><li>four MSB connectors</li><li><strong>two galvanically isolated measuring interfaces</strong></li><li>USB connector</li></ul>
- PCS
- 1
- iAquatrode Plus with Pt1000
- 6.0277.300
- Intelligent, combined pH electrode with integrated memory chip for storing sensor data and with Pt1000 temperature sensor for pH measurements/titrations in ion-deficient aqueous media (e.g., drinking water, process water). This electrode shows a very short response time in these samples. The fixed ground-joint diaphragm is insensitive to contamination. When c(KCl) = 3 mol/L is used as bridge electrolyte, storage in storage solution is recommended.The bridge electrolyte can be easily replaced with a chloride-free electrolyte (e.g., potassium nitrate c(KNO3) = 1 mol/L (6.2310.010)). Storage in the used bridge electrolyte.iTrodes can be connected to Titrando, Ti-Touch, or 913/914 meters.
- <p>Intelligent, combined pH electrode with integrated memory chip for storing sensor data and with Pt1000 temperature sensor for pH measurements/titrations in ion-deficient aqueous media (e.g., drinking water, process water). This electrode shows a very short response time in these samples. <br/><br/>The fixed ground-joint diaphragm is insensitive to contamination. <br/>When c(KCl) = 3 mol/L is used as bridge electrolyte, storage in storage solution is recommended.<br/>The bridge electrolyte can be easily replaced with a chloride-free electrolyte (e.g., potassium nitrate c(KNO<sub>3</sub>) = 1 mol/L (6.2310.010)). Storage in the used bridge electrolyte.<br/>iTrodes can be connected to Titrando, Ti-Touch, or 913/914 meters.</p>
- PCS
- 1
- iSolvotrode
- 6.0279.300
- Intelligent, combined pH electrode with integrated memory chip for storing sensor data for all non-aqueous acid/base titrations. The glass membrane is optimized for poorly conducting solutions, and thanks to the flexible ground-joint diaphragm, the electrode is well suited for contaminated samples. This electrode can be used with non-aqueous reference electrolytes (lithium chloride or tetraethylammonium bromide). Storage in the respective reference electrolyte.iTrodes can be connected to Titrando, Ti-Touch, or 913/914 meters.
- <p>Intelligent, combined pH electrode with integrated memory chip for storing sensor data for all non-aqueous acid/base titrations. <br/>The glass membrane is optimized for poorly conducting solutions, and thanks to the flexible ground-joint diaphragm, the electrode is well suited for contaminated samples. This electrode can be used with non-aqueous reference electrolytes (lithium chloride or tetraethylammonium bromide). Storage in the respective reference electrolyte.<br/>iTrodes can be connected to Titrando, Ti-Touch, or 913/914 meters.</p>
- PCS
- 1
- iPt Titrode
- 6.0471.300
- Combined platinum ring electrode with a pH glass membrane as reference electrode and integrated memory chip for storing sensor data.This maintenance-free electrode is suitable for redox titrations when the pH value remains constant, e.g.: Iodometry; Chromatometry; Cerimetry; Permanganometry; This electrode is stored in distilled water.iTrodes can be used on Titrando, Ti-Touch oder 913/914 meters.
- <p>Combined platinum ring electrode with a pH glass membrane as reference electrode and integrated memory chip for storing sensor data.<br/>This maintenance-free electrode is suitable for redox titrations when the pH value remains constant, e.g.:<br/> </p><ul><li>Iodometry</li><li>Chromatometry</li><li>Cerimetry</li><li>Permanganometry</li></ul><p><br/>This electrode is stored in distilled water.<br/>iTrodes can be used on Titrando, Ti-Touch oder 913/914 meters.</p>
- PCS
- 1
- Piston tongs
- 6.1546.030
- For pistons for 807 Dosing Units or cylinder units OMNIS.
- <p>For pistons for 807 Dosing Units or cylinder units OMNIS.</p>
- PCS
- 1
- Amber glass bottle / 1000 mL / GL 45
- 6.1608.023
- For Exchange Units. Bottle for auxiliary solutions.
- For Exchange Units. Bottle for auxiliary solutions.
- PCS
- 2
- Stirring propeller / 87 mm
- 6.1909.010
- Propeller stirrer, length from lower edge of SGJ: 96 mm. For use with beakers with 722, 802 Rod Stirrer
- <p>Propeller stirrer, length from lower edge of SGJ: 96 mm. For use with beakers with 722, 802 Rod Stirrer</p>
- PCS
- 1
- Support stand without support rod
- 6.2001.060
- To attach an 801, 804, 803 Stirrer to a Titrando, Titrino plus, Dosimat plus or 856 and 867.
- To attach an 801, 804, 803 Stirrer to a Titrando, Titrino plus, Dosimat plus or 856 and 867.
- PCS
- 1
- Clamping ring
- 6.2013.010
- For support rods with a diameter of 10 mm.
- <p>For support rods with a diameter of 10 mm.</p>
- PCS
- 1
- Support rod / 400 mm
- 6.2016.070
- PCS
- 1
- Electrode holder
- 6.2021.020
- Electrode holder for 4 electrodes and 2 buret tips
- Electrode holder for 4 electrodes and 2 buret tips
- PCS
- 1
- Holding clip for bottles
- 6.2043.005
- Holding spring for reagent bottles in exchange units.
- <p>Holding spring for reagent bottles in exchange units.</p>
- PCS
- 2
- Electrode cable / 1 m / F
- 6.2104.020
- For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
- For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
- PCS
- 1
- Cable USB A – mini-DIN 8-pin
- 6.2151.000
- Controller cable
- Controller cable
- PCS
- 1
- Buffer solutions pH 4, 7 and 9
- 6.2307.230
- Mixed buffer solutions pH 4.00/7.00/9.00 (25 °C) in single use sachets, colourless, box of 3 x 10 x 30 mL
- Mixed buffer solutions pH 4.00/7.00/9.00 (25 °C) in single use sachets, colourless, box of 3 x 10 x 30 mL
- PCS
- 1
- Electrolyte 3 mol/L KCl (50 mL)
- 6.2308.050
- Electrolyte solution c(KCl) = 3 mol/L (for Ag/AgCl reference systems)
- Electrolyte solution c(KCl) = 3 mol/L (for Ag/AgCl reference systems)
- PCS
- 1
- TEABr 0.4 mol/L in ethylene glycol (250 mL)
- 6.2320.000
- Electrolyte solution TEABr (tetraethylammonium bromide in ethylene glycol), c(TEABr) = 0.4 mol/L
- Electrolyte solution TEABr (tetraethylammonium bromide in ethylene glycol), c(TEABr) = 0.4 mol/L
- PCS
- 1
- Storage solution
- 6.2323.000
- Storage solution for all combined pH glass electrodes with reference electrolyte c(KCl) = 3 mol/L
- Storage solution for all combined pH glass electrodes with reference electrolyte c(KCl) = 3 mol/L
- PCS
- 1
- 5 mm hex key for IC Sample Processors
- 6.2621.070
- PCS
- 1
- Hexagon key 2 mm
- 6.2621.130
- 2 mm.
- 2 mm.
- PCS
- 1
- 807 Dosing Unit 20 mL
- 6.3032.220
- 807 Dosing Unit with integrated data chip with 20 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.
- <p>807 Dosing Unit with integrated data chip with 20 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.</p>
- PCS
- 2
- 800 Dosino (cable length 1.5 m)
- 1.800.0030
- Drive with write/read hardware for intelligent dosing units. With permanently attached cable (length 1.5 m).
- <p>Drive with write/read hardware for intelligent dosing units. With permanently attached cable (length 1.5 m).</p>
- PCS
- 2
- iAg Titrode
- 6.00470.300
- Intelligent, combined silver ring electrode with a pH glass membrane as reference electrode and integrated memory chip for storing sensor data.This maintenance-free electrode is suitable for precipitation titrations when the pH value remains constant (titrant silver nitrate), for example of: Chloride, Bromide, Iodide; Sulfides; Hydrogen sulfide; Mercaptans; Cyanides; This electrode is stored in distilled water.Depending on the application, we recommend using an Ag Titrode with Ag2S coating, which can be ordered accordingly.iTrodes can be used on Titrando, Ti-Touch or 913/914 meters.
- <p>Intelligent, combined silver ring electrode with a pH glass membrane as reference electrode and integrated memory chip for storing sensor data.<br/>This maintenance-free electrode is suitable for precipitation titrations when the pH value remains constant (titrant silver nitrate), for example of:<br/> </p><ul><li>Chloride, Bromide, Iodide</li><li>Sulfides</li><li>Hydrogen sulfide</li><li>Mercaptans</li><li>Cyanides</li></ul><p><br/>This electrode is stored in distilled water.<br/><br/>Depending on the application, we recommend using an Ag Titrode with Ag<sub>2</sub>S coating, which can be ordered accordingly.<br/>iTrodes can be used on Titrando, Ti-Touch or 913/914 meters.</p>
- PCS
- 1
-
- Adapter red 2 mm plug / 4 mm socket
- 6.2103.130
- For connecting plug B (4 mm) to 2 mm socket.
- For connecting plug B (4 mm) to 2 mm socket.
- PCS
- 1
- Adapter black 2 mm plug / B socket 4 mm
- 6.2103.140
- For connecting plug B (4 mm) to 2 mm socket.
- For connecting plug B (4 mm) to 2 mm socket.
- PCS
- 1