Aplicações
- 8.000.6020Titrimetric analyses of biofuels
Several testing methods such as the determination of the acid and the iodine numbers in biodiesel as well as the quantification of sulfate and chloride in bioethanol are described.
- 8.000.6021Water analysis
A complete tap water analysis includes the determination of the pH value, the alkalinity and the total water hardness. Both the pH measurement and the pH titration by means of a standard pH electrode suffer from several drawbacks. First, the response time of several minutes is too long and, above all, the stirring rate significantly influences the measured pH value. Unlike these standard pH electrodes, the Aquatrode Plus with its special glass membrane guarantees rapid, correct and very precise pH measurements and pH titrations in solutions that have a low ionic strength or are weakly buffered. Total water hardness is ideally determined by a calcium ion-selective electrode (Ca ISE). In a complexometric titration, calcium and magnesium can be simultaneously determined up to a calcium/magnesium ratio of 10:1. Detection limits for both ions are in the range of 0.01 mmol/L.
- 8.000.6022Automated preparation of surrogate mixtures for the determination of octane and cetane numbers
Commercially available fuels are complex mixtures of hundreds of different hydrocarbons. For the calibration of the test engines or advanced experimental and computational research they are modeled by means of multicomponent surrogate mixtures that adequately represent the desired physical and chemical characteristics. By definition, every octane and cetane number corresponds to a specific mixing ratio of primary reference fuels (PRFs). Based on this information, the tiamoTM controlled automatic dosing device prepares the surrogate mixtures. The setup drastically minimizes time-consuming and error-prone manual preparation steps and the contact with hazardous solvents. Additionally, precise and accurate results are displayed on customizable reports that fully comply with all current GLP and GMP requirements.
- 8.000.6023Determination of anionic and cationic surfactants by potentiometric two-phase titration
Compared to the classical Epton titration, potentiometrically indicated two-phase titrations using organic-solvent-resistant Surfactrodes can be easily automated and require no toxic and environmentally hazardous chloroform. Even challenging matrices such as fats and oils in bath oils and hair conditioners or strong oxidizing agents in washing powder and industrial cleaners do not interfere with the titration of the ionic surfactants. Results obtained show excellent agreement to those of the Epton titration. Irrespective of the matrix, relative standard deviations of threefold determinations are all below 2.1%. While the Surfactrode Resistant is mainly used for oil-containing formulations, the Surfactrode Refill is ideal for washing powders and soaps. Both electrodes excel by their ruggedness and allow the rapid and precise determination of anionic and cationic surfactants.
- 8.000.6024Fully automated sample preparation for the content determination of tablets
Benzbromaron is one of the main uricosuric drugs currently used. In addition to sophisticated and expensive LC-MS and GC-MS methods, benzbromaron can be effectively determined by titration with sodium hydroxide solution using a straightforward, fully automated sample preparation method. A high-frequency homogenizer comminutes one or three tablets within 90 or 120 s respectively. The overall analysis time is 8 minutes. Ten-fold determinations with one and three tablets resulted in a benzbromaron content of 99.2 and 98.7 mg per tablet respectively. Increasing the number of tablets from one to three lowers the RSD from 1.36 to 0.88%. These results show an excellent agreement with the benzbromaron content indicated by the manufacturer (approx. 100 mg/tablet).Besides the presented Titrando/homogenizer combination, the other two members of the 815 Robotic Soliprep Sample Processor family offer comprehensive sample preparation possibilities within the fields of IC, HPLC, ICP or voltammetry.
- 8.000.6034Determination of the sodium contribution of solvent-extractable organic compounds in Bayer process liquor
This poster presents a highly reproducible procedure for the determination of the sodium contribution of acid-extractable organic species in Bayer process liquor. The precision of the method is estimated to be 0.2% RSD.
- 8.000.6047Fully automated potentiometric determination of the hydroxyl number (HN) according to ASTM E1899-08 and DIN 53240-2
Hydroxyl is an important functional group and knowledge of its content is required in many intermediate and end-use products such as polyols, resins, lacquer raw materials and fats (petroleum industry). The test method to be described determines primary and secondary hydroxyl groups. The hydroxyl number is defined as the mg of KOH equivalent to the hydroxyl content of 1 g of sample.The most frequently described method for determining the hydroxyl number is the conversion with acetic anhydride in pyridine with subsequent titration of the acetic acid released: H3C-CO-O-CO-CH3 + R-OH -> R-O-CO-CH3 + CH3COOH. However, this method suffers from the following drawbacks: - The sample must be boiled under reflux for 1 h (long reaction time and laborious, expensive sample handling) - The method cannot be automated - Small hydroxyl numbers cannot be determined exactly - Pyridine has to be used, which is both toxic and foul-smellingBoth standards, ASTM E1899-08 and DIN 53240-2, offer alternative methods that do not require manual sample preparation and therefore can be fully automated: The method suggested in ASTM E1899-08 is based on the reaction of the hydroxyl groups attached to primary and secondary carbon atoms with excess toluene-4-sulfonyl-isocyanate (TSI) to form an acidic carbamate. The latter can then be titrated in a non-aqueous medium with the strong base tetrabutyl- ammonium hydroxide (TBAOH). The method suggested in DIN 53240-2 is based on the catalyzed acetylation of the hydroxyl group. After hydrolysis of the intermediate, the remaining acetic acid is titrated in a non-aqueous medium with alcoholic KOH solution. The present work demonstrates and discusses an easy way to determine the hydroxyl number according to ASTM E1899-08 or DIN 53240-2 with a fully automated titrimetric system for a great variety of industrial oil samples.
- 8.000.6048Fully automated determination of fluoride in blood samples
Sodium fluoride is used as a preservative in biological samples for alcohol analysis. All submitted blood samples, including those taken from vehicle drivers suspected of driving under the influence of liquor, have to be tested for adequate preservation prior to alcohol determination by gas chromatography. This is critical to ensure adequate sample preservation. Inadequate sample preservation may allow glycolysis and/or microorganism growth to produce ethanol.In the past this has been done by direct potentiometric measurement using a fluoride-selective electrode (F ISE), an ion meter and certified NaF standards. The sodium fluoride level was determined manually by dipping the electrode directly into the blood sample. Results were recorded manually. This poster describes two independent automated methods of analysis that allow the minimization of this tedious and time-consuming procedure.In the first one, the fluoride content in a blood aliquot is measured by direct potentiometric measurement after the addition of TISAB and deionized water. The second method employs the titration of the sample aliquot with La(NO3)3 after adding a buffer solution.
- 8.000.6066Determination of the total acid number (TAN) using thermometric titration
The thermometric titration method presented here permits a simple and direct determination of the total acid number (TAN) in petroleum products. It is an invaluable alternative to current manual and potentiometric methods. Thermometric titration uses a maintenance-free temperature sensor that does not require rehydration and is free of fouling and matrix effects. The procedure requires minimal sample preparation. Results agree closely with those from the potentiometric titrimetric procedure according to ASTM D664, but the thermometric titration method is far superior in terms of reproducibility and speed of analysis, with determinations being complete in approximately one minute.
- 8.000.6080Thermometric titration – the missing piece of the titration puzzle
Thermometric titration can solve application problems that potentiometry cannot solve at all, or at least not satisfactorily.
- 8.000.6111Fully Automated Determination of pH Using Flow Cell Technology
A high throughput automated system was developed to determine pH of culture media using a pH module equipped with an external flow cell. A custom septum-piercing, vented needle was developed to accommodate the shape and size of the customer sample vials. For this application, both accurate and precise pH measurements were required. The data presented in this document was collected by a customer as a part of their validation process and was provided for use with their consent.
- AB-004Biamperometric titration method for the determination of antimony in lead
An automatic titration method is described using biamperometric endpoint indication for the determination of antimony in antimony-alloyed cable lead (approx. 1% Sb). A 0.01 mol/L KBrO3 solution is used as the titrant.
- AB-011Determinação de zinco por titulação biamperométrica com hexacianoferrato(II) de potássio
O zinco, como aquele que ocorre como constituinte de ligas leves, pode ser determinado por titulação de precipitação com indicação de ponto final potenciométrico. A determinação de zinco na presença de cádmio também é possível. 2K4[Fe(CN)6] + 3 ZnCl2 → K2Zn3[Fe(CN)6]2 + 6KCl
- AB-014Determination of nickel by potentiometric titration
A potentiometric method for the determination of nickel in gold and silver electroplating baths is described. The titration is carried out with KCN. Gold and silver are removed before titration by a reduction process. It is also possible to determine nickel in steel alloys, etc. (see the literature reference). Ni2+ + 4 KCN + 2NH4+ → (NH4)2[Ni(CN)4] + 4 K+
- AB-016Routine determination of copper in brass, bronze, German silver and in electroplating baths
A routine method for the determination of copper is described. After dissolving the sample and adding a KI/KCNS solution, the released iodine is back-titrated with thiosulfate. The endpoint indication is potentiometric.
- AB-017Potentiometric titration of calcium carbonate in raw meal from the cement industry
A method for the potentiometric determination of CaCO3 in cement raw meal is described, in which the accurately weighed-out sample is treated with HCl, heated to boiling and the excess HCl is then back-titrated with NaOH.
- AB-018Determinação simultânea de ouro e cobre em banhos e/ou ligas de galvanoplastia por titulação potenciométrica
Este Boletim descreve a determinação simultânea de ouro e cobre por titulação potenciométrica utilizando uma solução de Fe(II) como titulante. O Fe(II) reduz o Au(III) diretamente ao metal livre, enquanto o Cu(II) não reage. Pela adição de íons fluoreto, o Fe(III) é complexado e uma mudança no potencial redox é efetuada. Em seguida, adiciona-se iodeto de potássio, reduzindo assim o Cu(II) a Cu(I), e o iodo livre é novamente titulado com a solução de Fe(II) utilizando um Pt Titrode. Reações químicas: Au(III) + 3Fe(II) → Au + 3Fe(III) 2 Cu(II) + 2 I- → 2 Cu(I) + I2 EU2 + 2Fe(II) → 2 eu- + 2Fe(III)
- AB-025Coatings on silver electrodes
Ag electrodes are used for the indication of the potentiometric endpoints in precipitation titrations between silver and halide or sulfide ions. A coating on the silver ring may increase the sensitivity of the electrode and can thus reduce the limit of detection. This is why a variety of coated Ag electrodes are commercially available. This bulletin describes how the silver ring of Ag electrodes can be coated with AgCl, AgBr, AgI or Ag2S by electrolysis.
- AB-027Potentiometric titration of chloride and bromide in the presence of each other
If chloride and bromide are present in approximately equal molar concentrations they can be titrated directly with silver nitrate solution after addition of barium acetate. If, however, the molar ratio n(Br-) : n(Cl-) changes from 1 : 1 to 1 : 5, 1 : 10, 5 : 1 or 10 : 1 then greater relative errors must be expected with this method. The Bulletin describes an additional titration method that allows bromide to be determined in the presence of a large excess of chloride. The determination of small chloride concentrations in the presence of a large excess of bromide is not possible by titration.
- AB-037Determinação de cromo em ferro e aço
Dois métodos são descritos para a determinação de cromo: uma titulação biamperométrica e uma análise polarográfica.
- AB-039Potentiometric determination of nitrating acid
A potentiometric, nonaqueous method is described for analyzing nitrating acid using cyclohexylamine as titrant. Both sulfuric and nitric acid can be determined quantitatively.
- AB-042Determination of carbonyl compounds by potentiometric titration
Carbonyl compounds (CC) occur in many products, such as bio-oils and fuels, cyclic and acyclic solvents, flavors and mineral oils. Carbonyl compounds can be responsible for the instability of these products during storage or processing. Especially pyrolysis bio-oils are known to cause issues during storage, handling and upgrading. This bulletin describes an aqueous and a non-aqueous analytical titration method for the determination of carbonyl compounds by potentiometric titration.
- AB-046Potentiometric determination of cyanide
The determination of cyanide is very important not only in electroplating baths and when decontaminating wastewater but, due to its high toxicity, also in water samples in general. Concentrations of 0.05 mg/L CN- can already be lethal for fish. This Bulletin describes the determination of cyanide in samples of different concentrations by potentiometric titration. Chemical reactions: 2 CN- + Ag+ → [Ag(CN)2]- [Ag(CN)2]- + Ag+ → 2 AgCN
- AB-048Check of Silver, Platinum and Gold electrodes
It is essential to know before starting the sample analysis if the electrode is in a good state or not. A well working electrode will increase the quality of your results, as the accuracy and precision will be increased. Furthermore, tedious error tracking can be omitted and no sample is wasted due to a defect or old electrode. There exist several ways how to check metal electrodes, e.g., measurement of redox potentials, potentiometric titration or bivoltammetric titration. This bulletin describes the best methods for the various by Metrohm available metal electrodes.
- AB-053Determination of ammonium or Kjeldahl nitrogen
The potentiometric titration of Kjeldahl nitrogen is one of the most common analytic procedures. It is referenced in numerous standards, ranging from the food and animal feed industries through sewage and waste analysis and all the way to the fertilizer industry. As a rule, the samples are digested with concentrated sulfuric acid with the addition of a catalyst. The ammonium sulfate that is formed is distilled as ammonia in alkali solution, collected in an absorption solution and titrated there. This Bulletin provides a detailed description of potentiometric nitrogen determination following distillation of the digestion solution, followed by a discussion of the possibilities of coulometric titration (without distillation).
- AB-061Potentiometric determination of silver – Accurate determination according to EN ISO and GB/T standards
Silver is an important metal not only in jewelry and silverware but also in electrical conductors and contacts. The knowledge of the exact silver content in fine silver and silver alloys ensures that quality standards for jewelry and silverware are met. As for the plating industry, the knowledge of the amount of silver in silver plating baths helps to run the bath efficiently. While X-ray fluorescence (XRF) is a fast alternative to determine the silver content in fine silver and silver alloys, it can only determine the silver content of the outermost sections of the metal. In contrast, titration offers a more comprehensive solution considering the whole sample, thus preventing fraud by thick plating. This application bulletin describes the potentiometric determination of silver in fine silver and silver alloys according to EN ISO 11427, ISO 13756, GB/T 17823, and GB/T 18996 as well as in silver plating baths by a titration with potassium bromide or potassium chloride, respectively
- AB-063Silicon, calcium, magnesium, iron and aluminum in cement after digestion and photometric titration
As much as the many types of cement may differ from one another, the characteristic that all of them have in common is the presence of the elements calcium, magnesium, iron, aluminum and silicon. Calcium, magnesium, iron and aluminum can be determined using various indicators following digestion of the cement sample using photometric titration with the Optrode at 610 nm. The determination of silicon, on the other hand, is gravimetric.
- AB-066Determinação potenciométrica e termométrica de ácido bórico
O ácido bórico é usado em muitos circuitos primários de usinas nucleares, em banhos de níquel e na produção de vidros ópticos. Além disso, compostos de boro são encontrados em detergentes em pó e fertilizantes. Este boletim descreve a determinação potenciométrica e termométrica de ácido bórico. A determinação também abrange outros compostos de boro, quando é aplicada digestão ácida.
- AB-068Potentiometric determination of carboxyl and amino terminal groups in polyamide fibers
Indication of the titration endpoint of the weakly alkaline or weakly acidic terminal groups in non-aqueous solution is frequently not easy. An improvement is possible by using a suitable titrant (TBAH = tetrabutylammonium hydroxide for terminal carboxyl groups; perchloric acid for terminal amino groups). An improvement in the evaluation can also be achieved by choosing benzyl alcohol as the solvent. The choice of electrode combination and the measuring setup is also important. Differential potentiometry using the three-electrode technique results in a great improvement in titrations in poorly conducting solutions. Noisy signals are eliminated.
- AB-069Titrimetric methods for the chemical analysis of pasta
The quality of egg-based pasta is primarily determined by its egg content. Also of importance, however, is the water content, which influences the storage life of the product, as well as the degree of acidity which, in the case of high values, indicates undesirable acidification during processing or drying. A check of the chloride content shows whether salt has been added to the pasta.
- AB-072Potentiometric determination of mercury or silver in the presence of halides
Halides interfere with most determinations of mercury or silver. However, if mercury or silver is titrated with sulfide ions, extremely insoluble sulfides are formed. A simple method is described that allows the direct titration of mercury(II) or silver(I) compounds in the presence of halides. The potentiometric titration takes place under alkaline conditions using thioacetamide as the titrant after formation of the EDTA complex. Organic compounds that are insoluble in alkaline EDTA can also be titrated after a Schoeniger digestion.
- AB-084Titrimetric analysis of vinegar
The quality of a vinegar depends on various factors. Since the contents of the individual components vary widely even from bottle to bottle, it is impossible to give average values. This Bulletin describes the determination of the following parameters in vinegar: pH value, total titratable acid, volatile, and non-volatile acid, free mineral acid as well as free and total sulfurous acid.
- AB-085Analysis of jams, fruit and vegetable juices, and their concentrates
This Bulletin describes analysis methods for determining the following parameters: pH value, total titratable acid, ash alkalinity, formol number, total sulfurous acid, chloride, sulfate, calcium, and magnesium. These methods are suitable for the analysis of jams, fruit and vegetable juices, and their concentrates.
- AB-087Analysis of dairy products
This Bulletin describes potentiometric titration methods for the determination of the acidity in milk and yoghurt according to DIN 10316, ISO/TS 11869, IDF/RM 150, ISO 6091 and IDF 86, the chloride content in milk, butter and cheese according to EN ISO 5943, IDF 88, ISO 15648, IDF 179, ISO 21422, and IDF 242. Additionally the determination of the sodium content in milk using the thermometric titration is described. The determination of the oxidation stability of butter in accordance to AOCS Cd 12b-92, ISO 6886 and GB/T 21121 as well as the determination of lactose in lactose free milk by ion chromatography is also described.For the determination of the pH value in dairy products see Application Bulletin AB-086 and for the determination of calcium and magnesium see Application Bulletin AB-235.
- AB-089Potentiometric analysis of anodizing baths
This Bulletin describes potentiometric titration methods for checking sulfuric acid and chromic acid anodizing baths. In addition to the main components aluminum, sulfuric acid, and chromic acid, chloride, oxalic acid, and sulfate are determined.
- AB-090Potentiometric analysis of tin plating baths
Potentiometric titration methods for the analysis of acid and alkaline tin plating baths are presented. The following methods are described: tin(II) / tin(IV) / total tin, free fluoroboric acid, or free sulfuric acid, chloride in acidic tin baths, free hydroxide, and carbonate in alkaline tin baths.
- AB-091Potentiometric analysis of brass and bronze plating baths
Methods are described for the potentiometric analysis of the following bath components: Brass plating bath: copper, zinc, free cyanide, ammonium, carbonate, and sulfite. Bronze plating bath: copper, tin, and free cyanide.
- AB-092Potentiometric analysis of lead plating baths
This Bulletin describes the potentiometric determination of lead, tin(II), and free fluoroboric acid.
- AB-093Potentiometric analysis of cadmium plating baths
This Bulletin describes titrimetric methods for the determination of cadmium, free sodium hydroxide, sodium carbonate, and total cyanide. The free cyanide can be calculated from the total cyanide and the Cd content.
- AB-098Determination of ascorbic acid (Vitamin C) and its compounds
In addition to its natural occurrence in fruit and vegetables, ascorbic acid (Vitamin C) is used as an antioxidant in foods and drinks. Ascorbic acid is furthermore also to be found in numerous drugs. Ascorbic acid and its salts and esters can be determined with titration or by using polarography, for which ascorbic acid is oxidized to form dehydroascorbic acid. Bi-voltammetric or photometric equivalence point indication can be used for titrimetric determination. It must be taken into account here that only bi-voltammetric indication is independent of the inherent color of the sample. Polarography is the most selective of the methods described, as other reducing or oxidizing substances are not recorded.
- AB-100Biamperometric determination of potassium and/or ammonium
The potassium (or ammonium) ion is precipitated with sodium tetraphenyl borate, and the excess of this reagent back-titrated against the thallous(I) ion, using biamperometric endpoint detection. Ammonium can either be titrated together in an acid solution, or driven off by previous boiling in an alkaline solution. Methods are given for determining potassium in the presence of large excesses of sodium, ammonium, calcium, and magnesium.
- AB-101Complexometric titrations with the Cu ISE
This Bulletin describes the complexometric potentiometric titration of metal ions. An ion-selective copper electrode is used to indicate the endpoint of the titration. Since this electrode does not respond directly to complexing agents, the corresponding Cu complex is added to the solution. With the described electrode, it is possible to determine water hardness and to analyze metal concentrations in electroplating baths, metal salts, minerals, and ores. The following metal ions have been determined: Al3+, Ba2+, Bi3+, Ca2+, Co2+, Fe3+, Mg2+, Ni2+, Pb2+, Sr2+, and Zn2+.
- AB-112Quantitative determination of metals that can be precipitated by potassium hexacyanoferrate(II) in wine («décassage» of wine)
Wine sometimes contains heavy metals which can be precipitated out by the addition of potassium ferrocyanide. Generally, these are quantities of iron ranging between 1 and 5 mg, and exceptionally up to 9 mg Fe/L. Zinc, copper, and lead – in descending order of content – may also be present. To estimate the quantity of potassium ferrocyanide necessary for the «décassage of the wine», only very complicated and relatively inaccurate methods have been described until now. This Bulletin permits accurate results to be obtained easily with a simple instrumentation. The results are available in a short time.
- AB-119Potentiometric determination of trace bromide and iodide in chlorides
Bromide is removed from the sample as BrCN by distillation. The BrCN is absorbed in sodium hydroxide solution and decomposed with concentrated sulfuric acid, then the released bromide ions are determined by potentiometric titration with silver nitrate solution. Iodide does not interfere with the determination. Iodide is oxidized to iodate by hypobromite. After destruction of the excess hypobromite, the potentiometric titration (of the iodine released from iodate) is carried out with sodium thiosulfate solution. Bromide does not interfere, even in great excess. The described methods allow the determination of bromide and iodide in the presence of a large excess of chloride (e.g., in brine, seawater, sodium chloride, etc.).
- AB-125Simultaneous determination of calcium, magnesium, and alkalinity by complexometric titration with potentiometric or photometric indication in water and beverage samples
This bulletin describes the determination of calcium, magnesium, and alkalinity in water by complexometric titration with EDTA as titrant. It is grouped into two parts, the potentiometric determination and the photometric determination. There are multiple definitions of the different types of water hardness. In this Application Bulletin, the following definitions are used: alkalinity, calcium hardness, magnesium hardness, total hardness, and permanent hardness. Explanations of these definitions and other expressions are provided in the Appendix. Determination of alkalinity during the photometric part is carried out in a separate acid-base titration before the complexometric titration of calcium and magnesium in water. Permanent hardness can be calculated from these values. The determination of calcium and magnesium in beverages (fruit and vegetable juices, wine) is also described. The photometric part includes the determinations of total and calcium hardness and thereby indirectly magnesium hardness using Eriochrome Black T and calconcarboxylic acid as indicators (in accordance with DIN 38406-3).
- AB-129Potentiometric determination of orthophosphates, metaphosphates, and polyphosphates
After acid digestion, the sample solution is neutralized with sodium hydroxide to form sodium dihydrogen phosphate. An excess of lanthanum nitrate is added and the released nitric acid is then titrated with sodium hydroxide solution. NaH2PO4 + La(NO3)3 → LaPO4 + 2 HNO3 + NaNO3 This determination method is suitable for higher phosphate concentrations.
- AB-130Chloride titrations with potentiometric indication
Besides acid-base titrations, the titrimetric determination of chloride is one of the most frequently used titrimetric methods of analysis. It is employed more or less frequently in practically every laboratory. This Bulletin shows you how to determine chloride in a wide range of concentrations using automatic titrators. Silver nitrate is normally used as titrant (for environmental reasons one should refrain from using mercury nitrate). The titrant concentration depends on the chloride content of the sample to be analyzed. It is crucial to choose the correct electrode for samples with low chloride contents.
- AB-135Potentiometric determination of hydrogen sulfide, carbonyl sulfide, and mercaptans in petroleum products
This Bulletin describes the potentiometric determination of hydrogen sulfide, carbonyl sulfide, and mercaptans in gaseous and liquid products of the oil industry (natural gas, liquefied petroleum gas, used absorption solutions, distillate fuels, aviation gasoline, gasoline, kerosene, etc.). The samples are titrated with alcoholic silver nitrate solution using the Ag Titrode.
- AB-140Titrimetric sulfate determination
This Bulletin describes three potentiometric, one photometric, one thermometric and one conductometric titration method for sulfate determination. The question of which indication method is the most suitable depends primarily on the sample matrix. Method 1: Precipitation as barium sulfate and back titration of the Ba2+ surplus with EGTA. Use of the ion-selective calcium electrode as indicator electrode. Method 2: As with Method 1, although with the electrode combination tungsten/platinum. Method 3: Precipitation titration in semi-aqueous solution with lead nitrate in accordance with the European Pharmacopoeia using the ion-selective lead electrode as indicator electrode. Method 4: Photometric titration with lead nitrate, dithizone indicator and the Optrode 610 nm, particularly suitable for low concentrations (up to 5 mg SO42- in the sample solution). Method 5: Thermometric precipitation titration with Ba2+ in aqueous solution, particularly suitable for fertilizers. Method 6: Conductometric titration with barium acetate in accordance with DIN 53127
- AB-141Analysis of edible fats and oils – The seven most important parameters for quality control
As the determination of the exact content of individual glycerides in fats and oils is difficult and time-consuming, several fat sum parameters or fat indices are used for the characterization and quality control of fats and oils. Fats and oils are not only essential for cooking, they are also an important ingredient in pharmaceuticals and personal care products, such as ointments and creams. Consequently, several norms and standards describe the determination of the most important quality control parameters. This Application Bulletin describes eight important analytical methods for the following fat parameters in edible oils and fats: Determination of water content in accordance with the Karl Fischer method Oxidation stability in accordance with the Rancimat method Iodine value Peroxide value Saponification value Acid value, free fatty acids (FFA) Hydroxyl number Traces of nickel using polarography Special care is taken to avoid chlorinated solvents in these methods. Also, as many of the mentioned methods as possible are automated.
- AB-143Determination of complexing agents in detergents
Application Bulletin AB-076 contains a description of the polarographic determination of low concentrations (1–100 mg/L) of NTA and EDTA in bodies of water. NTA, EDTA and citrate have gained in importance as complexing agents and builders due to the fact that the laws of some countries have made it necessary to find a substitute for phosphates in detergents. This Bulletin describes the determination of larger quantities of complexing agents in detergents using potentiometric titration. The ion-selective copper electrode (Cu-ISE) is used here as the indicator electrode. The determination of complexing agents is not disturbed by the other constituents often present in detergents.
- AB-177Automatic determination of the bromine number and the bromine index in petroleum products
The bromine number and bromine index are important quality control parameters for the determination of aliphatic C=Cdouble bonds in petroleum products. Both indices provide information on the content of substances that react withbromine. The difference between the two indices is that the bromine number indicates the consumption of bromine in gfor 100 g sample and the bromine index in mg for 100 g sample.This Application Bulletin describes the determination of the bromine number according to ASTM D1159, ISO 3839, BS2000-130, IP 130, GB/T 11135 and DIN-51774-1. The bromine index determination for aliphatic hydrocarbons is described according to ASTM D2710, IP 299, GB/T 11136 and DIN 51774-2. For aromatic hydrocarbons the determination of the bromine index is described according to ASTM D5776 and SH/T 1767. UOP 304 is not recommended for the determination of the bromine number or bromine index because its titration solvent contains mercuric chloride.
- AB-178Fully automated water analysis
The determination of the physical and chemical parameters as electrical conductivity, pH value, p and m value (alkalinity), chloride content, the calcium and magnesium hardness, the total hardness, as well as fluoride content are necessary for evaluating the water quality. This bulletin describes how to determine the above mentioned parameters in a single analytical run. Further important parameters in water analysis are the permanganate index (PMI) and the chemical oxygen deman (COD). Therefore, this Bulletin additionally describes the fully automated determination of the PMI according to EN ISO 8467 as well as the determination of the COD according to DIN 38409-44.
- AB-180Automatic determination of the formol number in fruit and vegetable juices
The formol number represents a further parameter for the characterization of fruit and vegetable juices. As this is merely an index (the formalin number does not deal with the molecular size, nor with the quantity of amino acids), the conditions of the titration can be adapted to meet practical needs. This concerns mainly the pH value of the endpoint of the SET titration (pH = 8.5, pH = 9.0, pH = 9.2, etc.).
- AB-181Automatic potentiometric titration of aluminum and magnesium in the same solution
Mixtures of aluminum and magnesium ions can be analyzed automatically using potentiometric titration. The excess DCTA is back-titrated with copper(II) sulfate solution after the addition of 1,2-diaminocyclohexanetetraacetic acid (DCTA) and complex formation. The ion-selective copper electrode is used here as the indicator electrode. First, the aluminum is determined in acidic solution and then the magnesium in alkali solution.
- AB-195Titrimetric determination of free boric acid and tetrafluoroboric acid in nickel plating baths
This Bulletin describes the simultaneous potentiometric titration of free boric acid and free tetrafluoroboric acid in nickel plating baths. After addition of mannitol, the formed mannitol complexes are titrated with sodium hydroxide solution. The determination is carried out directly in the plating bath sample; nickel and other metal ions do not interfere.
- AB-200Índice de acidez, índice de hidroxila e isocianatos em matérias-primas para fabricação de plásticos – Determinação por titulação potenciométrica automática de acordo com diversas normas
Os poliuretanos são um dos tipos de plástico mais comumente usados. Eles são produzidos pela reação de polióis brutos com isocianatos. Dependendo do material de partida pode ser obtida uma grande variedade de plásticos. A determinação do índice de acidez, do índice de hidroxila e do teor de isocianato desempenha um papel importante na análise de matérias-primas para plásticos. O índice ácido da matéria-prima poliol é geralmente usado no controle de qualidade para garantir a uniformidade entre lotes. Além disso, é usado como fator de correção para calcular o verdadeiro número de hidroxila. Neste Boletim de Aplicação é descrita a determinação do índice de acidez de acordo com ASTM D4662 e ASTM D7253. Uma matéria-prima para poliuretanos são os polióis. Os polióis contêm vários grupos hidroxila. Portanto, o número de hidroxila de uma matéria-prima se correlaciona diretamente com a quantidade de polióis presentes e é, portanto, um importante parâmetro de controle de qualidade. Neste Boletim de Aplicação é descrita a determinação do índice de hidroxila de acordo com ASTM E1899 e DIN 53240-3. Como os polióis reagem estequiometricamente com os isocianatos, o conhecimento do teor de isocianato é um importante parâmetro de qualidade para a produção de poliuretanos. Neste documento é descrita a determinação de acordo com EN ISO 14896 método A, ASTM D5155 método A e ASTM D2572.
- AB-206Titer determination in potentiometry
This Bulletin provides an overview of the potentiometric titer determination of current titrants. Many publications only describe methods with color indicators. However, the titration conditions chosen for the titer determination should resemble those used for the actual analysis as closely as possible. The tables contain suitable titrimetric standard substances and electrodes for selected titrants as well as additional information. Following this, an example is given to show what an SOP for a titer determination could look like.
- AB-221Standard methods in water analysis
This Bulletin gives a survey of standard methods from the field of water analysis. You will also find the analytical instruments required for the respective determinations and references to the corresponding Metrohm Application Bulletins and Application Notes. The following parameters are dealt with: electrical conductivity, pH value, fluoride, ammonium and Kjeldahl nitrogen, anions and cations by means of ion chromatography, heavy metals by means of voltammetry, chemical oxygen demand (COD), water hardness, free chlorine as well as a few other water constituents.
- AB-223Fully automated determination of uranium
This Bulletin describes the fully automated determination of uranium according to the method of Davies and Gray: Uranium(VI) is reduced in concentrated phosphoric acid solution with iron(II) to form Uranium(IV). With molybdenum as a catalyst, the excess iron(II) is oxidized with nitric acid. The nitrous acid that is formed is destroyed with sulfamic acid before uranium(IV) is titrated with a potassium dichromate solution in the presence of a vanadium catalyst.
- AB-225Simple wine analysis
The Bulletin describes the determination of the following parameters in wine: pH value, total titratable acid, free sulfurous acid, total sulfurous acid as well as ascorbic acid (vitamin C) and other reductones.
- AB-230Potentiometric determination of nonionic surfactants based on polyoxyethylene adducts with the NIO electrode
The titrimetric determination of nonionic surfactants on the basis of polyoxyethylene adducts (POE adducts) is described in the Bulletin. The basis for the determination is the transfer of the nonionic surfactant into a pseudo-cation compound and its precipitation titration with sodium tetraphenylborate (Na-TPB). The NIO electrode is used for the indication of the potentiometric titration. This Bulletin describes determinations in raw products, formulations and wastewater and draws attention to special features, possibilities, limits and disruptions.
- AB-233Potentiometric determination of anionic and cationic surfactants with surfactant electrodes
Anionic surfactants can be titrated with cationic surfactants and vice-versa. The Bulletin describes a multitude of substances that can be determined in this fashion and specifies the respective working conditions and parameters. In contrast to the classic two-phase titration in accordance with Epton, the titration with the anionic and cationic surfactants electrodes can be performed without chloroform. Furthermore, the equivalence point of the titration is difficult to determine in some cases with the Epton method and the titration cannot be automated. In many cases, a surfactant ISE is a remedy that is both environmentally friendly and suitable here. It was developed specially for application with potentiometrically indicated surfactant determinations.
- AB-235Potentiometric titration of calcium (magnesium) in dairy products
This Bulletin describes a simple method for the determination of the calcium content in dairy products. The use of CuEGTA and the ion-selective copper electrode (Cu ISE) as indicator electrode allows the determination to be performed without time-consuming sample preparation. If the complexing agent EDTA is used as titrant instead of EGTA, the sum of calcium and magnesium is obtained. The magnesium content can then be calculated from the difference between the results of the two titrations.
- AB-249Determination of free and residual chlorine based on DIN EN ISO 7393-1 and APHA 4500-Cl
Chlorine is frequently added to drinking water for disinfection. Depending on the reactivity and the concentration of chlorine, toxic disinfection by-products (DBPs) can thereby be released. Therefore, it is necessary to strictly control the chlorine concentration in the drinking water. This Application Bulletin shows how to determine the chlorine concentration according to three standard methods: DIN EN ISO 7939-1, APHA 4500-Cl Method B, and APHA 4500-Cl Method I.
- AB-264Titrimetric methods for the determination of betains
The two potentiometric titration methods described here allow the determination of the content of commercial betaine solutions. Neither method is suitable for determining the betaine content of formulations. The possibilities and limits of both methods are described and distinctive features and possible sources of interference are mentioned. The Bulletin explains the most important theoretical principles and is intended to help users to develop their own product-specific titration methods.
- AB-268Potentiometric titration of surfactants and pharmaceuticals – an overview
The present Bulletin offers an overview of the multitude of surfactants and pharmaceuticals that can be determined with potentiometric titration. Metrohm provides five different surfactant electrodes for indicating the titration endpoint: the Ionic Surfactant, the High Sense, the Surfactrode Resistant, the Surfactrode Refill and the NIO Surfactant electrode. The manufacture of the respective titrants and their titer determination are described in detail. In addition to this, the Bulletin contains a tabular overview of more than 170 proven applications from the area of surfactant and pharmaceutical analysis. This guideline leads you reliably to your destination: At a glance you can see from the table which surfactant electrode and which titrant are optimally suitable for your product.
- AB-269Potentiometric determination of ionic surfactant through two-phase titration with the Surfactrode
On the basis of a multitude of practical examples, this Bulletin describes the potentiometric two-phase titration of ionic surfactants in raw materials and many other formulations. Two surfactant electrodes – the Surfactrode Resistant and the Surfactrode Refill – make it possible to perform this type of surfactant titration, analogous to the classic "Epton titration", with a high degree of automation. The achieved results correlate very well with those of Epton titration. The toxic, carcinogenic and environmentally hazardous chloroform can be replaced by other solvents such as methyl iosbutyl ketone or n-hexane.
- AB-275Potentiometric two-phase titration of anionic surfactants in washing powder and liquid detergent
Two-phase titration with potentiometric indication is a universal method for the determination of ionic surfactants in detergents. The results obtained are comparable to those with the classic two-phase titration in accordance with Epton (mixed indicator system disulfine blue / dimidium bromide). The present Bulletin addresses various parameters that could have an influence on potentiometric surfactant titration. The information provided makes it possible for the user to determine precisely the anionic surfactant content in practically all formulations.
- AB-298Sodium determination in various foods with thermometric titration
In an acidic solution (containing NH4F * HF, Al(NO3)3 / KNO3) sodium forms NaK2AlF6 which precipitates in an exothermic solution, enabling analysis by thermometric titration. Several foods were analyzed, namely bouillon, gravy, tomato ketchup, corn chips, pretzel sticks as well as crackers. The reproducibility of the results was good. After weighing in and adding solutions, samples were crushed with a polytron to ensure homogeneity in the measuring solution. Relative standard deviations were between 0.08% and 3.75%. In addition to this application bulletin, you can find more information on thermometric sodium determination in foods in our application video available on YouTube:https://youtu.be/lnCp9jBxoEs
- AB-304Titration of whole blood and blood plasma for acid-base analysis according to Joergensen and Stirum
The presented Application Bulletin describes the apparatus and methods that are used for acid-base analysis of whole blood and blood plasma by Joergensen and Stirum. Evaluation of the measured data is performed with a software sold by Komstar AG.
- AB-305Check of surfactant electrodes
This Application Bulletin describes methods for checking the condition of electrodes for surfactant titration. For testing electrodes used for ionic surfactant titration (Ionic Surfactant electrodes), sodium dodecyl sulfate (SDS) is determined using TEGO®trant. Conversely, for testing electrodes used for cationic surfactant titration (Cationic Surfactant electrodes), TEGO®trant is titrated with SDS. For non-ionic surfactant electrodes (NIO surfactant electrode), PEG 1000 is titrated with sodium tetraphenylborate (STPB). For testing Surfactrode Resistant and Surfactrode Refill electrodes, titrations of SDS with TEGO®trant are performed. Suitable criteria for the test are the height of the potential jump and the shape of the titration curve. Key word: NaPh4B
- AB-307Determination of sulfate in granular phosphate fertilizers with thermometric titration
Sulfate can be rapidly and easily titrated thermometrically using a standard solution of Ba2+ as titrant. In industry, the widespread procedure is applied to the determination of sulfate in wet-process phosphoric acid. This bulletin deals with the determination of sulfate in granular fertilizers such as MAP (monoammonium phosphate), DAP (diammonium phosphate) and TSP (triple superphosphate). Results are reported as percentage of elemental sulfur, %S.
- AB-308Determination of sulfate in phosphoric acid (liquid fertilizer samples) with thermometric titration
Sulfate can be rapidly and easily titrated thermometrically using a standard solution of Ba2+ as titrant. In industry, the widespread procedure is applied to the determination of sulfate in wet-process phosphoric acid.
- AB-313Analysis of Bayer process liquors using thermometric titration
The determination of the total causticizer, sodium carbonate and aluminum oxide contents in (Bayer) process liquors can be accomplished with high precision and speed by using the 859 Titrotherm in a thermometric acid-base titration. A complete titration takes approximately 5 minutes. The procedure is an automated adaptation of the traditional Watts-Utley method, and is similar to the VanDalen-Ward thermometric titration method, but with the added advantage that the analysis can also be performed for the carbonate content of the liquor.
- AB-314Determination of total phosphate in phosphoric acid and phosphate fertilizers with thermometric titration
Phosphate can be rapidly and easily titrated thermometrically using a standard solution of Mg2+ as titrant. The phosphate-containing solution is basified and buffered with NH3/NH4Cl solution before titration. The formation of insoluble MgNH4PO4 is exothermic. The method is a titrimetric adaptation of a classical gravimetric procedure. This bulletin deals with the determination of phosphate in phosphoric acid and granular fertilizers such as MAP (monoammonium phosphate), DAP (diammonium phosphate) and TSP (triple superphosphate). Results are reported as percentage of P and P2O5.
- AB-315Determination of free fatty acids (FFA) in edible oils with thermometric titration
In titration, the titrant reacts with the analyte either exothermically (gives off heat) or endothermically (absorbs heat). The Thermoprobe measures the temperature change during titration. When all of the analyte has reacted with the titrant, the temperature of the solution will change, and the endpoint of the titration is indicated by an inflection in the temperature curve. Catalytically enhanced titrations using paraformaldehyde as catalyst are based on the endothermic hydrolysis of the paraformaldehyde in the presence of excess hydroxide ions. Edible oils are dissolved in a mixture of toluene and 2-propanol (1:1) and titrated with standardized TBAH (0.01 mol/L) in 2-propanol to a catalytically enhanced endpoint.
- AB-316Determination of phosphoric acid in liquid fertilizer with thermometric titration
The phosphoric acid content can be easily titrated with a standardized solution of 2 mol/L NaOH. The interfering calcium content in phosphoric fertilizer can be eliminated by adding a saturated oxalate solution.
- AB-322Determinação potenciométrica totalmente automatizada do número de hidroxila (HN) de acordo com ASTM E1899 e DIN EN ISO 4629-2
O sistema de titulação apresentado pode ser utilizado para a determinação totalmente automatizada do número de hidroxila (HN) de acordo com ASTM E1899 e EN ISO 4629-2. O método permite a determinação de polióis e oxoóleos sem ferver sob refluxo ou outra preparação de amostra e é, portanto, um grande benefício para laboratórios que precisam lidar com um alto rendimento de amostras. As normas EN 15168 e DIN 53240-3 baseiam-se no mesmo método de análise da ASTM E1899.
- AB-340Bromine index (BI) by coulometric titration
This bulletin describes a procedure to determine the bromine index (BI) using coulometric titration. The bromine index is the fraction of reactive unsaturated compounds (mostly C=C double bonds) in hydrocarbons encountered in the petrochemical industry. The double bonds are split with the attachment addition of bromine.
- AB-342Automated determination of calcium and magnesium in milk with thermometric titration
This bulletin deals with the automated determination of calcium and magnesium in commercially available finished milk products using a 859 Titrotherm and a 814 USB Sample Processor. Calcium and magnesium in milk can be rapidly and easily titrated thermometrically using a standard solution of Na4EDTA as titrant.Thermometric titrations are conducted under conditions of constant titrant addition rate. The molarity of the titrant is computed automatically in tiamo (software) using the SLO command. Results are reported as mg Ca and Mg/100 mL.
- AB-343Automated determination of sodium in milk with thermometric titration
This bulletin discusses automated determination of sodium in milk products available to the public using a 859 Titrotherm and a 814 USB Sample Processor. The sodium content of milk can be rapidly and easily titrated thermometrically with a standard solution of Al3+ as titrant. Thermometric titrations are conducted under conditions of constant titrant addition rate. The molarity of the titrant is computed automatically in tiamoTM (software) with the SLO command. Results are reported as mg Na/100 mL. In addition to this application bulletin, you can find more information on thermometric sodium determination in foods in our application video available on YouTube:https://youtu.be/lnCp9jBxoEs
- AB-344Automated analysis of etch acid mixtures for silicon substrates with thermometric titration
This bulletin deals with the automated determination of mixtures of HNO3, HF and H2SiF6 in the range of approximately 200-600 g/L HNO3, 50-160 g/L HF, and 0-185 g/L H2SiF6 using thermometric titration.Etch acid mixtures containing HNO3, HF and H2SiF6 from the etching of silicon substrates can be analyzed in a sequence of two determinations using the 859 Titrotherm. The first determination involves a direct titration with standard c(NaOH) = 2 mol/L, followed by a back titration with c(HCl) = 2 mol/L. This determination yields the H2SiF6 content plus a value for the combined (HNO3+HF) contents. The second determination consists of a titration with c(Al3+) = 0.5 mol/L to determine the HF content. For freshly made up mixtures of HNO3 and HF containing no H2SiF6, a linked two-titration sequence is employed. Results from the two determinations are used by tiamoTM to yield individual results for HNO3, HF and H2SiF6.
- AB-404Total acid number titration of petroleum products
The determination of the acid number plays a significant role in the analysis of petroleum products. This is manifested in the numerous standard procedures in use over the world (internal specifications of multinational companies, national and international specifications of ASTM, DIN, IP, ISO, etc.). These procedures differ mainly in the composition of the used solvents and titrants.This bulletin describes the determination of the acid number in petroleum products by applying different types of titration.The potentiometric determination is described according to ASTM D664, the photometric according to ASTM D974 and the thermometric titration according to ASTM D8045.
- AB-405Total base number titration of petroleum products
This Application Bulletin shows the determination of the total base number in petroleum products by applying different titration types according to various standards.
- AB-427Acid number in petroleum products with thermometric titration
This Application Bulletin describes the determination of the total acid number in various oil samples by catalytic thermometric titration as per ASTM D8045.
- AB-441Assay of pyrithione complexes – Reliable determination by potentiometric titration
Pyrithione complexes, such as zinc pyrithione (ZnPT), copper pyrithione (CuPT), and sodium pyrithione (NaPT), are used as fungicides and bactericides. ZnPT is used in the treatment of skin conditions such as seborrheic dermatitis or dandruff. Furthermore, ZnPT is sometimes used as an antibacterial agent in paints to prevent algae and mildew growth. CuPT is primarily in use as a biocide to prevent biofouling of surfaces submerged in water. Meanwhile, NaPT is used as antifungal agent for treatment of mycosis, such as athlete’s foot. The different pyrithione complexes are determined by iodometric titration using a maintenance-free Pt Titrode for the indication.
- AN-H-003Determinação de sulfato em ácido fosfórico
Determinação do teor de sulfato do ácido fosfórico de processo úmido.
- AN-H-004Determination of fluoride by boric acid titration
This Application Note explains how fluoride determination in acid etching baths can be performed with thermometric titration.
- AN-H-005Determinação de íons cuprosos na presença de íons ferrosos
Determinação de íons cuprosos na presença de íons ferrosos em soluções eletroquímicas de lixiviação de cobre.
- AN-H-006Determination of nonionic surfactants
Determination of a nonionic surfactant of the alkyl propylene oxide derivative type in commercial mixtures containing anionic surfactants.
- AN-H-007Padronização da solução de tetrafenilborato de sódio
Padronização de solução de tetrafenilborato de sódio (NaTPB) para determinação de potássio e de tensoativos não iônicos.
- AN-H-008Determination of phosphate by magnesium titration
Determination of soluble orthophosphate ions, for example soluble phosphate in fertilizers such as DAP.
- AN-H-009Determinação de sulfato em salmouras
Determinação do teor de sulfatos em salmouras.
- AN-H-010Determinação de cálcio em fluidos de perfuração
A titulação termométrica avalia com rapidez e precisão o conteúdo total de sólidos dos fluidos empregados na perfuração de poços de petróleo e gás em poucos minutos.
- AN-H-011Determinação do teor total de sólidos de fluidos de perfuração
A titulação termométrica apresenta-se como um método simples, rápido e confiável para determinar o teor de cálcio em diversos fluidos de perfuração.
- AN-H-012Determination of ferrous ion content of heat exchanger wash solutions
Determination of ferrous ions in heat exchanger and vessel acid wash solutions, for measuring the effectiveness of acid inhibitors used in the solutions. Depending on the condition of the sample, the lower practical limit for the determination will vary from approximately 20-100mg/Kg Fe2+. Samples with high silicic acid contents require relatively large amounts of dilution water to render them mobile, and this limits the aliquot size and hence the amount of Fe2+ which can be analyzed.
- AN-H-013Determinação do teor de umidade de sólidos ultrafinos
Determinação de água em sólidos particulados úmidos, como oxihidróxido de cobalto.
- AN-H-014Determination of free acid content of solutions containing Fe(III)
Determination of free acid in solutions containing metal ions, particularly Fe(III).
- AN-H-015Determinação de anidrido acético em misturas de acilação
Determinação de anidrido acético na presença de ácido acético em misturas de acilação.
- AN-H-016Determination of acetic, phosphoric, and nitric acid mixtures
Determination of mixtures of phosphoric, nitric, and acetic acids used in etching aluminum in the manufacture of semiconductor devices.
- AN-H-017Determinação de brometo e cloreto em soluções reveladoras fotográficas
Determinação de brometo e cloreto em soluções reveladoras fotográficas.
- AN-H-018Determinação de cloreto em fluidos de perfuração
Determinação de cloreto em fluidos de perfuração de poços de petróleo.
- AN-H-019Determinação de cloro em alvejantes domésticos
Determinação de cloro em alvejantes domésticos.
- AN-H-020Determination of chromium in leather waste solutions
Determination of chromium in leather waste solutions in the range between 1000 and 30,000 ppm.
- AN-H-021Determinação de ácido livre em soluções de refino de cobre
Determinação de ácido livre em soluções de refino de cobre.
- AN-H-022Determination of moisture in lubricating oils with TEOF
Determination of moisture in lubricating oils with TEOF (triethyl orthoformate).
- AN-H-023Determinação de níquel por titulação de dimetilglioxima
Determinação de níquel na ausência de cobalto e outras interferências.
- AN-H-024Determination of tar acids (phenolics) in tar products
Determination of tar acids in coal tar products. This procedure may also be applied to the determination of a range of weakly acidic organic compounds such as carboxylic acids, hydroxy acids, phenols, phenolic acids, keto-enols, imides, and aromatic nitro compounds.1 1 Vaughan, G. A. Thermometric and Enthalpimetric Titrimetry. Van Nostrand Reinhold Co. Ltd (1973)
- AN-H-025Determinação de umidade em óleos lubrificantes por DMP
Determinação de água em óleos lubrificantes automotivos.
- AN-H-026Determinação de caustificante, carbonato e óxido de alumínio em licor do processo Bayer
Esta Nota de Aplicação descreve um método para a determinação de caustificante, carbonato e óxido de alumínio em licores usados do processo Bayer. O método é baseado em processos desenvolvidos por Watts-Utley e VanDalen-Ward.
- AN-H-027Determinação de soda orgânica em licores de aluminato Bayer
Determinação da basicidade total de compostos orgânicos extraíveis de caráter ácido em licores de refinaria do processo Bayer.
- AN-H-028Standardization of 0.1 mol/L KOH in propan-2-ol
Standardization of 0.1 mol/L in propan-2-ol for use in applications for the determination of weakly acidic species in non-aqueous media.
- AN-H-030Determination of chlorite by direct titration with thiosulfate
Determination of chlorite by direct thermometric titration with standard sodium thiosulfate solution. The procedurewas applied originally to the determination of chlorite in hide treatment solutions.
- AN-H-031Determinação de baixos níveis de sulfato por deslocamento de cromato de bário
Determinação de baixos níveis de sulfato (até aproximadamente 20mg/L SO42-) por titulação termométrica.
- AN-H-032Standardization of ammonium ferrous sulfate solution
Standardization of 0.1 mol/L ammonium ferrous sulfate solution for use in thermometric titration of Cr(VI) solutions.
- AN-H-033Determinação de baixos níveis de cloreto na água
Determinação de baixos níveis de cloreto (até aproximadamente 5 mg/L Cl-) por titulação termométrica.
- AN-H-034Determinação de cálcio e magnésio em amostras de processo
Determinação de cálcio e magnésio em soluções de processo.
- AN-H-035Fosfato em fertilizantes – Determinação rápida e confiável por titulação termométrica
O fósforo é um macronutriente primário para as plantas e é um constituinte do DNA e do trifosfato de adenosina (ATP), que está envolvido em muitos processos biológicos que requerem energia. Nos fertilizantes, o fósforo está presente na forma de fosfato, pois a forma de fósforo mais acessível para as plantas é o dihidrogenofosfato. O conhecimento do teor de fósforo ajuda a selecionar o fertilizante certo para as plantas. Tradicionalmente, o fosfato é determinado gravimetricamente (um procedimento demorado) ou espectrofotometricamente (instrumentação cara). Nesta Nota de Aplicação é apresentado um método alternativo, onde o fosfato é determinado por uma titulação de precipitação com magnésio. Foram analisados diversos fertilizantes NPK sólidos e líquidos com teores de fósforo entre 6,5 e 17%. A análise por titulação termométrica não requer preparação de amostra no caso de fertilizantes NPK líquidos e apenas preparação mínima de amostra no caso de fertilizantes NPK sólidos. Uma determinação leva cerca de 5 minutos.
- AN-H-037Determinação de fosfato em uma mistura de ataque ácido
Determinação do teor de fosfato em banho de ataque ácido.
- AN-H-038Determination of sulfate and total acids in a nitrating mixture
Determination of sulfate and total acids in a nitrating mixture.
- AN-H-039Determinação de lauril éter sulfato de sódio
Determinação de surfactantes lauril éter sulfato de sódio.
- AN-H-040Determination of HCl (ppm range) in silicone oil
Determination of low content of HCl (around 10 ppm) in silicone oil.
- AN-H-041Padronização de soluções de cloreto de cetilpiridínio
Padronização de soluções de cloreto de cetilpiridínio para uso como titulante de surfactante catiônico na determinação de surfactantes aniônicos, como lauril éter sulfato de sódio.
- AN-H-042Padronização do titulante tiossulfato para determinações de cobre
Esta Nota de Aplicação discute a padronização do titulante tiossulfato para uso na determinação de cobre com titulação termométrica.
- AN-H-044Standardization of EDTA titrant by copper
Thermometric complexometric titration of metals is often performed with tetrasodium EDTA. This Application Note explains the standardization of tetrasodium EDTA titrant with copper.
- AN-H-045Padronização do titulante EDTA por magnésio
Esta nota de aplicação explica como usar magnésio para padronizar o titulante EDTA tetrassódico.
- AN-H-046Standardization of copper back-titrant by EDTA
Standardization of copper back-titrant using standard tetrasodium EDTA titrant in the determination of metals.
- AN-H-048Standardization of disodium dimethylglyoximate for the determination of nickel
Standardization of disodium dimethylglyoximate by thermometric titration with standard Ni(II) solution.
- AN-H-049Determination of nickel by titration with disodium dimethylglyoximate
Determination of nickel in solution by titration with standard disodium dimethylglyoximate.
- AN-H-050Determinação de silicatos de sódio e potássio
Determinação dos valores de sódio, potássio e sílica em silicatos de sódio e potássio.
- AN-H-051Determination of sodium hypophosphite
Determination of sodium hypophosphite in electroless plating solutions.
- AN-H-052Determination of nickel in electroless plating solutions
Thermometric titration of nickel in electroless plating solution with disodium dimethylglyoximate.
- AN-H-053Determination of aluminum by fluoride titration
Determination of aluminum in acidic, basic, and neutral solutions; including aluminum chloride, aluminum chlorohydrate (also in anti-perspirant formulations), alum, etching solutions, and aluminate solutions.
- AN-H-055Analysis of sodium and phosphorus in sodium tripolyphosphate precursor solutions
Determination of Na, P, and [Na]/[P] in precursor solutions and solids in the manufacture of sodium tripolyphosphate.
- AN-H-056Standardization of barium acetate solution
Standardization of barium acetate titrant used in the determination of sulfate in phosphoric acid. The same procedure is applied if barium chloride is chosen as the titrant.
- AN-H-057Standardization of sodium fluoride for aluminum titrations
Standardization of sodium fluoride titrant for determination of aluminum.
- AN-H-058Determinação de sódio como cloreto em ketchup e molhos
Determinação de sódio como cloreto em ketchups, molhos e produtos alimentícios similares.
- AN-H-060Standardization of 0.1 mol/L perchloric acid in glacial acetic acid
Standardization of 0.1mol/L perchloric acid in glacial acetic acid by catalyzed endpoint thermometric titration.
- AN-H-061Direct titration of sodium
Determination of sodium in salts, process solutions, and foods.
- AN-H-062Standardization of titrant for direct titration of sodium
Standardization of titrant for direct determination of sodium.
- AN-H-064Total base number (TBN) in used motor oils
The determination of the total base number (TBN) in motor oils is accomplished by means of titration with a standard solution made up of trifluoromethanesulfonic acid in glacial acetic acid and isobutyl vinyl ether as reagent for improved end point identification.
- AN-H-065Determination of salts of carboxylic acids by aqueous acidometric titration
Determination of sodium and potassium salts of carboxylic acids in aqueous media. May be used for analysis of reagent purity.
- AN-H-067Determination of chloride in Bayer process liquor
Determination of chloride in Bayer process liquor.
- AN-H-070Determination of ferric and cupric Ions in copper refining solutions
Determination of Fe3+ and Cu2+ in copper refining solutions by thermometric titration. It was found that the conventional approach of masking Fe3+ to permit the iodometric determination of Cu2+ is not possible in some copper refining solutions.
- AN-H-071Determination of ammonium ions by titration with hypochlorite
Determination of ammonium ions in ammonium salts and mixtures containing ammonium ion.
- AN-H-073Determination of total acid number (TAN) in biodiesel
Determination of Total Acid Number (TAN) values in biodiesel to <0.05 mg KOH/g sample.
- AN-H-074Determination of calcium and magnesium in seawater
Determination of calcium and magnesium in seawater. The method is suitable for determining the effect of caustic soda and alumina refinery aluminate solutions on the calcium and magnesium content of seawater.
- AN-H-075Standardization of tetrasodium EDTA solutions
Standardization of ~1mol/L tetrasodium EDTA solutions for thermometric complexometric analysis.
- AN-H-077Determinação de sódio em salmouras por titulação de alumínio
Determinação de sódio em água do mar e salmouras similares. Este procedimento é adequado para a análise de sódio em água do mar contaminada com soluções de aluminato de sódio provenientes de refinarias de alumina e água do mar que tem sido utilizada para a neutralização de resíduos de refinarias de alumina («lama vermelha») pastas.
- AN-H-078Determination of total halides in brines
Determination of total halides (Cl- + Br- +I-) in seawater and similar brines. This procedure is suitable for the analysis of total halides in seawater contaminated with sodium aluminate solutions emanating from alumina refineries, and seawater which has been used for the neutralization of alumina refinery waste («red mud») slurries. Given the small concentration of bromine andiodine in seawater, the total halide content approximates the chloride concentration.
- AN-H-079Determination of free acid in heat exchanger cleaning acid
Determination of free acid in sulfuric acid («acid shot») solutions employed in the removal of silicate scale in heat exchangers. This method is suitable for acid shot solutions where the silicic acid content is so high that the solutions have gelled.
- AN-H-080Determination of total sodium in sodium aluminate liquors by aluminum titration
Determination of the total sodium content of sodium aluminate liquors, such as Bayer Process liquor. This method is suitable for the analysis of all sodium aluminate solutions down to at least 1 g/L as Na2CO3. The determination may be automated by adding an 814 USB sample processor to an 859 Titrotherm.
- AN-H-081Determination of phosphoric and nitric acid in nitrophos liquors
Determination of phosphoric and nitric acids in liquors from the Nitrophos fertilizer manufacturing process.
- AN-H-082Determination of surface acidity in Zeolites and other materials with a high specific surface area
This Application Note outlines the determination of total acidic active surface sites in zeolites with thermometric titration.
- AN-H-083Determination of surface basicity in zeolites and other materials with a high specific surface area
This Application Note shows that the parameter of surface basicity of zeolites can be measured by thermometric titration.
- AN-H-084Determination of mixtures of sulfuric, phosphoric, and nitric acids
Determination of mixtures of sulfuric, phosphoric, and nitric acids. The procedure is suitable for automated analysis using an 814 Sample Processor.
- AN-H-086Determinação de sódio em batatas fritas
Titulação de uma suspensão não filtrada da amostra com uma solução padronizada de alumínio contendo um excesso estequiométrico de íons potássio na presença de hidrogenodifluoreto de amônio a ~ pH 3 para dar uma reação exotérmica, formando NaK insolúvel2AlF6. O titulante é padronizado contra uma solução preparada a partir de sulfato de sódio anidro ou carbonato de sódio. Além desta nota de aplicação, você pode encontrar mais informações sobre determinação termométrica de sódio em alimentos em nosso vídeo de aplicação disponível no YouTube: https://youtu.be/lnCp9jBxoEs
- AN-H-087Determination of hydrofluoric acid by aluminum titration
Determination of hydrofluoric acid in mixed acid etchant solutions.
- AN-H-088Automated determination of total acid number (TAN) in oils
Automated determination of total acid number (TAN) in new and used lubricating oils and crude oils using the 814 USB Sample Processor. Dissolve oil sample in mixture of toluene and 2-propanol, add paraformaldehyde and titrate with 0.1 mol/L or 0.01 mol/L KOH in propan-2-ol. The endpoint is indicated by an endothermic response caused by the base-catalyzed depolymerization of paraformaldehyde.Reference: 1. M. J. D. Carneiro, M. A. Feres Júnior, and O. E. S. Godinho. Determination of the acidity of oils using paraformaldehyde as a thermometric end-point indicator. J. Braz. Chem. Soc. 13 (5) 692-694 (2002)
- AN-H-089Automated analysis of hexafluorosilicic acid
Automated determination of the H2SiF6 and HF contents of industrial grade hexafluorosilicic acid.
- AN-H-090Nickel in electroless nickel solutions by thermometric EDTA titration
Automated thermometric titration of the nickel content of electroless nickel plating solutions. The determination is suitable for fully automated titration employing a 814 Sample Processor.
- AN-H-091Standardization of tetrasodium EDTA solutions with standard magnesium solution
Standardization of 1 mol/L tetrasodium EDTA (Na4EDTA) solutions by titration with standard magnesium solution.
- AN-H-092Analysis of zirconium acetate
Automated determination of the zirconium content of zirconium acetate, as well as other zirconium compounds which can be rendered soluble as zirconium acetate.
- AN-H-093Determination of boric acid by fluoride titration
Determination of boric acid in electroless plating solutions.
- AN-H-094Determinação de boro em minérios por titulação de flúor
Determinação de boro em minérios do elemento como bórax e ulexita.
- AN-H-095Determination of urea by non-aqueous titration
Dissolution of urea in glacial acetic acid, and titration with standard 0.1 mol/L trifluoromethanesulfonic acid in acetic acid using isobutyl vinyl ether as a thermometric endpoint indicator.
- AN-H-096Determination of total base number of lubricating oils
Dissolution of oil in toluene, and titration with standard 0.1 mol/L trifluoromethanesulfonic acid in acetic acid using isobutyl vinyl ether as a thermometric endpoint indicator.
- AN-H-097Determination of calcium and magnesium in harvested salt
A measured amount of salt is titrated directly with a solution of 1 mol/L tetrasodium EDTA to thermometrically determined endpoints for Ca and Mg. Acetylacetone is added to alter the Ca and Mg EDTA stability constants for better endpoint sharpness.
- AN-H-098Determination of hydrofluoric acid in silicon etch solutions
This Application Note describes the determination of fluoride in silicon etch solutions with thermometric titration.
- AN-H-100Determination of total acids in highly acidic etch solutions
Determination of the total acids concentration in mixtures of nitric-hydrofluoric acid intended for etching silicon substrates.
- AN-H-101Determination of the water content of mineral acids
A sample of concentrated mineral acid is dissolved in anhydrous acetonitrile, and the water content titrated with a solution of TEOF in acetonitrile. The TEOF reacts exothermically with water in the presence of a strong acid (acting as a catalyst).
- AN-H-102Determinação de Hipoclorito por Titulação com Íon Amônio
Os íons hipoclorito reagem com os íons brometo para formar íons hipobromito, que por sua vez oxidam rapidamente os íons de amônio em nitrogênio. O hipobromito reage mais rapidamente com o amônio do que o hipoclorito e é formado in situ (Vogel, 1961). A titulação é realizada em solução contendo brometo e bicarbonato.
- AN-H-103Determination of Calcium and Magnesium in Milk
A measured amount of milk is treated with trichloroacetic acid to coagulate milk solids and liberate calcium and magnesium as dissociated ion. The coagulated milk is filtered or centrifuged, and an aliquot of the clear serum is titrated with a standard solution of 1 mol/L tetra-sodium EDTA to thermometrically determined endpoints for Ca and Mg. Acetylacetone is added to alter the Ca- and Mg- EDTA stability constants for better endpoint sharpness.
- AN-H-104Determination of free acid content of hydrometallurgical leach liquors
A measured amount of acidic hydrometallurgical leach liquor is treated with potassium oxalate solution to mask potential interference from Fe(III) and other metal ions, and then titrated with standard 1 mol/L NaOH solution.
- AN-H-105Determination of nickel in hydrometallurgical leach liquors
A measured amount of acidic hydrometallurgical leach liquor is first treated with hydrogen peroxide to oxidize Fe(II) to Fe(III), then with potassium pyrophosphate solution to mask interference from Fe(III) and other metal ions. Ammonium acetate solution is then added as a pH modifier, before being titrated with standardized disodium dimethylglyoximate to an exothermic endpoint.
- AN-H-106Determination of magnesium content in hydrometallurgical leach liquors
A measured amount of acidic hydrometallurgical leach liquor is treated first with a complexing agent (sodium gluconate). It is then basified to ~pH 10.5 with a NH3 /NH4Cl buffer, prior to the addition of KCN solution to mask Fe(III). Caution! Do not add KCN to solutions of pH below 9! The Fe(III) is then reduced to Fe(II) by additon of ascorbic acid, prior to titrating the Mg content with standard Na4EDTA solution.
- AN-H-107Determination of ferrous ion content in hydrometallurgical leach liquors
A measured amount of acidic hydrometallurgical leach liquor is further acidified with sulfuric acid, prior to being titrated with standard potassium dichromate solution to an exothermic endpoint. Thus, 1 mol K2Cr207 ≡ 6 mol Fe2+.
- AN-H-108Determination of ferric ion in hydrometallurgical leach liquors
A measured amount of acidic hydrometallurgical leach liquor is pH modified with a small amount of glacial acetic acid, and the Fe(III) content reduced to Fe(II) with iodide ion. The liberated iodine is titrated with standard thiosulfate solution to an exothermic endpoint. Thus, 1 mol Fe3+= 1 mol S2O32-.
- AN-H-109Determination of sulfuric acid, hydrofluoric acid, and ammonium bifluoride in acid mixtures
Results from three separate single endpoint titrations are used to calculate the results. The mixture of H2SO4, HF, and NH4F/HF contains H+ from H2SO4, HF, and NH4F/HF, SO42- from H2SO4, and F- from HF and NH4F/HF. Analysis of total H+ («total acids») by NaOH titration, F- by titrating with Al(NO3)3 («total fluoride») and SO42- by titrating with BaCl2 provides the information required to determine the composition of the mixture.
- AN-H-110Determinação de sulfato em água potável por deslocamento de cromato de bário
O sulfato é precipitado pela reação com uma solução acidificada de cromato de bário. O excesso de cromato de bário é precipitado por basificação com solução de amônia. O cromato solúvel residual equivalente ao teor de sulfato da amostra é titulado com uma solução de íon ferroso padrão até um ponto final determinado termometricamente.
- AN-H-111Determination of sulfate in harvested salt
Sulfate is precipitated as barium sulfate by reaction with an acidified barium chromate solution. The excess barium chromate is precipitated by basification with ammonia solution. Residual soluble chromate, equivalent to the sulfate content of the sample, is titrated with a solution of standard ferrous ion to a thermometrically determined endpoint.
- AN-H-114Determination of sulfuric acid, nitric acid, and hydrofluoric acid in etch solutions
Two separate titration sequences are required to analyze the mixture: - titration of the HF content with Al(NO3)3 (the «elpasolite» reaction) - titration of the H2SO4 with BaCl2 followed by titration with NaOH to determine the «total acids» content The HF, H2SO4, and «total acids» contents are converted to a HNO3 equivalent, with the HNO3 content found by subtracting the HF and H2SO4 from the «total acids» content.
- AN-H-115Determination of hydrofluoric acid, ammonium fluoride, and maleic acid in acid cleaning solutions
A direct thermometric titration (TET) with 2 mol/L NaOH is used to determine the HF, NH4F, and maleic acid (C4H4O4) contents of acid cleaning solutions. Three endpoints (EPs) are obtained, which may be assigned as follows: EP1: C4H4O4 (pKa1 = 1.9), HF (pKa = 3.17) EP2: C4H4O4 (pKa2 = 6.07) EP2: NH4F (pKa = 8.2) The HF content is determined by subtracting the difference (EP2-EP1) from EP1.
- AN-H-116Determination of sulfate in phosphoric acid through the standard addition of sulfuric acid
This Application Note supplements AN-H-003 with the treatment of the standard addition of sulfate as sulfuric acid. This technique may be contemplated when either sulfate levels are too low for a satisfactory direct titration, or when the sample matrix hinders endpoint detection, leading to poor precision and accuracy.
- AN-H-117Rapid determination of hydroxide and aluminum oxide in aluminate liquors
This Application Note describes the determination of the free and total hydroxide and aluminum oxide content in Bayer process and other aluminate liquors. The method is not subject to interference by carbonate ions. An aliquot of sodium aluminate liquor is titrated with potassium hydrogen carbonate solution to yield the free hydroxide ion content of the liquor.
- AN-H-118Determination of hydrochloric acid in acidic solutions containing iron and aluminum
The presence of the hydrated ion [Fe(H2O)6]3+ can interfere with the determination of «free acid» due to the low pKa value (~2.2) of this ion. Ions of metals such as Fe, Cu, and Al can be masked effectively with fluoride, and permit the determination of the acid content by thermometric alkalimetric titration with good accuracy and precision.
- AN-H-119Determinação de íon férrico em soluções ácidas
Esta Nota de Aplicação trata da determinação de íon férrico em soluções ácidas e isentas de cobre usando titulação termométrica. O íon férrico é reduzido pelo iodeto. O iodo liberado reage exotérmicamente quando titulado com solução de tiossulfato. O ponto final é determinado através da plotagem de temperatura pelo sensor de temperatura Thermoprobe.
- AN-H-120Determination of aluminum ion in acidic solutions containing ferric and ferrous ions
This Application Note describes the determination of aluminum ion down to approximately 0.5 g/L in acidic solutions containing ferric, ferrous, and other ions whose hydroxides do not dissolve in strongly basic solutions.
- AN-H-121Determination of ferrous ion in acidic solutions with ceric solution
This Application Note looks at the determination of ferrous ion in acidic solutions from approximately 0.25 g/L by thermometric titration with ceric titrant. The exothermic oxidation reaction shows a sharp endpoint that is detected using the Thermoprobe as a sensitive temperature sensor.
- AN-H-122Determination of sodium in canned fish products
This Application Note describes the determination of total sodium content in canned fish products using thermometric titration. In addition to this application note, you can find more information on thermometric sodium determination in foods in our application video available on YouTube: https://youtu.be/lnCp9jBxoEs
- AN-H-123Determination of sodium in instant noodles
This Application Note describes the determination of the total sodium content in instant noodles which are also called «two minute noodles» in some countries. These products contain considerable amounts of sodium (at least 50% of the recommended daily dosage), which means that precise analysis of the sodium content is required. Argentometric titration of the chloride content (assuming that the sodium content in the noodles originates exclusively from the sodium chloride that is added to them) is unsuitable for precise analysis, as the nutrient contents listed on the product packaging document the presence of additional sodium salts other than sodium chloride. Thermometric titration enables fast and direct determination of sodium. In addition to this application note, you can find more information on thermometric sodium determination in foods in our application video available on YouTube: https://youtu.be/lnCp9jBxoEs
- AN-H-124Determination of sodium content in the manufacturing of margarine
This Application Note describes the determination of the total concentration of sodium in precursor solutions used in the manufacturing of margarine. The solutions of the precursors are mixed with edible fats and oils to make margarine. Traces of sodium chloride and other sodium and potassium salts may be added to the margarine during this process, usually in the form of emulsifiers, stabilizers, antioxidants, vitamins, coloring agents or flavor enhancers. The analysis of the total sodium content in the precursor solutions is more efficient and cost-effective for the manufacturers than later total sodium content analyses in the final product. As a rule, argentometric titration of chloride is used for indirect determination of the sodium content of foodstuffs. The assumption behind this approach is that the chloride ions are present in a molar ratio of 1:1 with the sodium ions. This is however not the case when – as is usually the case with foodstuffs containing sodium – additional compounds containing sodium are also present in the margarine. The use of potassium chloride as a partial replacement for sodium chloride in some formulations is an additional source of error. The direct titration of sodium by means of thermometric endpoint titration (TET) eliminates these problems. TET is a direct determination method that not only takes into account the entire sodium content present in the solution but is also not hampered by the presence of potassium ions. In addition to this application note, you can find more information on thermometric sodium determination in foods in our application video available on YouTube: https://youtu.be/lnCp9jBxoEs
- AN-H-125Determination of sodium in soy milk
This application note describes the determination of the total sodium content in soy milk products. The methodology may also be applied to the determination of sodium in milk products from cows, goats and sheep. A standard addition technique is employed to permit the accurate and precise determination of sodium at relatively low levels.
- AN-H-126Determination of silver and nitric acid in silver electrolyte bath
Silver and nitric acid are determined in silver electrolyte solutions by means of thermometric titration. The method provides accurate results in a short time and is ideally suited for routine process control.
- AN-H-127Thermometric analysis of aluminum by back-titration
This Application Note describes the determination of aluminum in samples containing silicon dioxide using thermometric titration and EDTA as the titrant. Excess EDTA is titrated with a Cu2+ solution of known concentration. The initial, uncomplexed Cu2+ ions react immediately with the H2O2 present in the solution, leading to a recognizable sudden increase in temperature.
- AN-H-128Determination of ferrous ion in acidic solutions with permanganate as titrant
This Application Note looks at the determination of ferrous ion in acidic solutions through redox titration with potassium permanganate as titrant and thermometric titration.
- AN-H-129Determination of weak bases in nonaqueous media through catalyzed thermometric endpoint titration (CETT)
Weak, organic bases that are soluble in nonaqueous solvents (including nonpolar solvents) are determined in glacial acetic acid using titration with strong acids, e. g., anhydrous perchloric acid or trifluoromethanesulfonic acid. The endpoint of such titrations can be determined thermometrically, insofar as a suitable thermometric endpoint indicator exists. The exceptional suitability of isobutyl vinyl ether (IBVE) as indicator has been demonstrated.
- AN-H-130Determination of nitrite using sulfamic acid
This Application Note describes the determination of nitrite using thermometric endpoint titration with sulfamic acid. The nitrite content of a solution can be analyzed down to 0.2 mmol/L.
- AN-H-131Determination of titer and blank value for thermometric titrations using tiamo™
This Application Note describes in detail how to determine the blank value and the titer for thermometric titrations using tiamo™.