2.1028.0010
Eco Coulometer with generator electrode with diaphragmThe Eco Coulometer with integrated magnetic stirrer and touch-sensitive display is ideal for water content determination in the 10 µg to 200 mg absolute water range. Predefined methods enable a smooth and easy instrument start-up. In addition to GLP-compliant printouts on paper or as PDFs, the Eco Coulometer also offers the option of being able to connect balances or send determination data to a PC via PC / LIMS reports. Indicator electrode and generator electrode with diaphragm are included in the scope of delivery.Coulometry is the ideal method for water content determination in the trace range in liquids, solids and gases. In addition, coulometry is an absolute method making titer determination unnecessary.
2.1028.0110
Eco Coulometer with generator electrode without diaphragmThe Eco Coulometer with integrated magnetic stirrer and touch-sensitive display is ideal for water content determination in the 10 µg to 200 mg absolute water range. Predefined methods enable a smooth and easy instrument start-up. In addition to GLP-compliant printouts on paper or as PDFs, the Eco Coulometer also offers the option of being able to connect balances or send determination data to a PC via PC / LIMS reports. Indicator electrode and generator electrode without diaphragm are included in the scope of delivery.Coulometry is the ideal method for water content determination in the trace range in liquids, solids and gases. In addition, coulometry is an absolute method making titer determination unnecessary.
2.1029.0010
Solvent PumpSolvent Pump is used with an Eco Titrator / Eco KF Titrator / Eco Coulometer for reliably adding solvent and aspirating off titration vessel content without contact with the reagents.Device-independent use is also possible with optional 6.2164.010 power supply unit.
2.831.0010
831 KF Coulometer with generator electrode with diaphragmInexpensive coulometer including titration cell and generator electrode with diaphragm for water content determination down to trace levels.This coulometer has become indispensable in many laboratories, thanks to its reliability, its backlit graphical display, the multi-language dialog and the simplicity of its operation. The clear display provides information regarding the relevant titration parameters and unambiguous indication of the progress of the titration in the form of a curve showing µg water over time.Recommended measuring range: 10 µg - 200 mg absolute water
2.831.0110
831 KF Coulometer with generator electrode without diaphragmInexpensive coulometer including titration cell with generator electrode without diaphragm for water content determination down to the trace range.This coulometer has become indispensable in many laboratories, thanks to its reliability, its backlit graphical display, the multi-language dialog and the simplicity of its operation. The clear display provides information regarding the relevant titration parameters and unambiguous indication of the progress of the titration in the form of a curve showing µg water over time.Recommended measuring range: 10 µg - 200 mg absolute water
2.756.0010
756 KF Coulometer with generator electrode with diaphragmKF coulometer with built-in printer and titration cell with generator electrode with diaphragm for water content determination down to trace levels.This coulometer has become indispensable in many laboratories thanks to its reliability, its backlit graphical display, the multi-language dialog and the simplicity of its operation. The clear display provides information regarding the relevant titration parameters and unambiguous indication of the progress of the titration in the form of a curve showing µg water over time.Recommended measuring range: 10 µg - 200 mg absolute water
2.756.0110
756 KF Coulometer with generator electrode without diaphragmKF coulometer with built-in printer and titration cell with generator electrode without diaphragm for water content determination down to trace levels.This coulometer has become indispensable in many laboratories thanks to its reliability, its backlit graphical display, the multi-language dialog and the simplicity of its operation. The clear display provides information regarding the relevant titration parameters and unambiguous indication of the progress of the titration in the form of a curve showing µg water over time.Recommended measuring range: 10 µg - 200 mg absolute water
2.917.0010
917 Coulometer with generator electrode with diaphragmThe 917 Coulometer is a compact titrator for coulometric water determination in accordance with Karl Fischer. ''Reduced to the max'' – operating module, stirrer and pump are integrated in the 917 Coulometer for rapid reagent replacement. This saves a great deal of space on the laboratory table.Recommended measuring range: 10 µg…200 mg absolute waterCoulometry is the ideal method for water content determination in liquids, solids and gases in the trace range. In addition, coulometry is an absolute method and thus no titer determination is necessary.The 917 Coulometer now also fulfills FDA Regulation 21 CFR, Part 11. This means you are always on the safe side when it comes to audits.
2.917.0110
917 Coulometer with generator electrode without diaphragmThe 917 Coulometer is a compact titrator for coulometric water determination in accordance with Karl Fischer. ''Reduced to the max'' – operating module, stirrer and pump are integrated in the 917 Coulometer for rapid reagent replacement. This saves a great deal of space on the laboratory table.Recommended measuring range: 10 µg…200 mg absolute waterCoulometry is the ideal method for water content determination in liquids, solids and gases in the trace range. In addition, coulometry is an absolute method and thus no titer determination is necessary.The 917 Coulometer now also fulfills FDA Regulation 21 CFR, Part 11. This means you are always on the safe side when it comes to audits.
2.143.0200
TX-900MH impact printerCompact impact printer with USB and RS232 interface for 900 Touch Control (+); 915 KF Ti-Touch (+); 916 Ti-Touch (+); 917 Coulometer (+); 91X Meter (+)Eco Dosimat/Titrator (+); 877/848 Titrino plus (additional 6.2151.100 required); 865/876 Dosimat plus (additional 6.2151.100 required); 862 Compact Titrosampler (additional 6.2151.100 required); 870 KF Titrino plus (additional 6.2151.100 required); 899 Coulometer (additional 6.2151.100 required); (+) Cable included in scope of delivery
2.899.0010
899 Coulometer with generator electrode with diaphragmThanks to the integrated stirrer, the 899 Coulometer takes up less space on the laboratory table than a sheet of DIN A4 paper. Although small and compact, the coulometer does not compromise on performance. Water contents can be determined with precision down to trace levels. Indicator electrode and generator electrode with diaphragm are included in the scope of delivery.Recommended measuring range: 10 µg - 200 mg absolute waterCoulometry is the ideal method for water content determination in liquids, solids and gases in the trace range. In addition, coulometry is an absolute method and thus no titer determination is necessary.
2.899.0110
899 Coulometer with generator electrode without diaphragmThanks to the integrated stirrer, the 899 Coulometer takes up less space on the laboratory table than a sheet of DIN A4 paper. Although small and compact, the coulometer does not compromise on performance. Water contents can be determined with precision down to trace levels. Indicator electrode and generator electrode without diaphragm are included in the scope of delivery.Recommended measuring range: 10 µg - 200 mg absolute waterCoulometry is the ideal method for water content determination in liquids, solids and gases in the trace range. In addition, coulometry is an absolute method and thus no titer determination is necessary.
2.142.0100
Custom Q3X thermal printerCompact printer with USB interface for 900 Touch Control; 915 KF Ti-Touch; 916 Ti-Touch; 917 Coulometer; 877 / 848 Titrino plus; 865 / 876 Dosimat plus; 91X Meter (cable 6.2151.140); Eco Dosimat / Titrator; 862 Compact Titrosampler; 870 KF Titrino plus; 899 Coulometer; Paper width 60 mm (40 characters). Including 6.2151.120 USB cable.
2.899.1010
899 Coulometer with generator electrode with diaphragm and Q3X USB thermal printerThanks to the integrated stirrer, the 899 Coulometer takes up less space on the laboratory table than a sheet of DIN A4 paper. Although small and compact, the coulometer does not compromise on performance. Water contents can be determined with precision down to trace levels. Indicator electrode, generator electrode with diaphragm and a Q3X USB thermal printer are included in the scope of delivery.Recommended measuring range: 10 µg - 200 mg absolute waterCoulometry is the ideal method for water content determination in liquids, solids and gases in the trace range. In addition, coulometry is an absolute method and thus no titer determination is necessary.
2.899.1110
899 Coulometer with generator electrode without diaphragm and Neo's USB thermal printerThanks to the integrated stirrer, the 899 Coulometer takes up less space on the laboratory table than a sheet of DIN A4 paper. Although small and compact, the coulometer does not compromise on performance. Low water contents can be determined with precision down to trace levels. Indicator electrode, generator electrode without diaphragm and a Q3X USB thermal printer are included in the scope of delivery.Recommended measuring range: 10 µg - 200 mg absolute waterCoulometry is the ideal method for water content determination in liquids, solids and gases in the trace range. In addition, coulometry is an absolute method and thus no titer determination is necessary.
2.852.0150
852 Titrando with generator electrode without diaphragmCoulometer including generator electrode without diaphragm and complete volumetric titration cellCoulometry is the ideal method for water content determination in liquids, solids, and gases when it comes to water content determination in the trace range (10 µg to 10 mg absolute water). In addition, coulometry is an absolute method and thus no titer determination is necessary.Recommended coulometry measuring range: 10 µg - 200 mg absolute water.The 852 Titrando controls not only coulometric, but also volumetric Karl Fischer titration.For use with OMNIS Software, tiamo software, or Touch Control unit. Compliance with GMP/GLP and FDA regulations such as 21 CFR Part 11, if required.
2.852.0050
852 Titrando with generator electrode with diaphragmCoulometer including generator electrode with diaphragm, 801 Magnetic Stirrer, and complete volumetric titration cell.Coulometry is the ideal method for water content determination in liquids, solids, and gases when it comes to water content determination in the trace range (10 µg to 10 mg absolute water). In addition, coulometry is an absolute method and thus no titer determination is necessary.Recommended coulometry measuring range: 10 µg - 200 mg absolute waterThe 852 Titrando controls not only coulometric, but also volumetric Karl Fischer titration.For use with OMNIS Software, tiamo software, or Touch Control unit. Compliance with GMP/GLP and FDA regulations such as 21 CFR Part 11, if required.
2.851.0110
851 Titrando with generator electrode without diaphragmCoulometer including generator electrode without diaphragm.Coulometry is the ideal method for water content determination in liquids, solids, and gases when it comes to water content determination in the trace range (10 µg to 10 mg absolute water). In addition, coulometry is an absolute method and thus no titer determination is necessary.Coulometric titrations are carried out easily and quickly with the 851 Titrando.Recommended measuring range: 10 µg - 200 mg absolute water.For use with OMNIS Software, tiamo software, or Touch Control unit. Compliance with GMP/GLP and FDA regulations such as 21 CFR Part 11, if required.
2.851.0010
851 Titrando with generator electrode with diaphragmCoulometer including generator electrode with diaphragm and 801 Magnetic Stirrer.Coulometry is the ideal method for water content determination in liquids, solids, and gases when it comes to water content determination in the trace range (10 µg to 10 mg absolute water). In addition, coulometry is an absolute method and thus no titer determination is necessary.Coulometric titrations are carried out easily and quickly with the 851 Titrando.Recommended measuring range: 10 µg - 200 mg absolute waterFor use with OMNIS Software, tiamo software, or Touch Control unit. Compliance with GMP/GLP and FDA regulations such as 21 CFR Part 11, if required
2.852.0060
852 Titrando with Touch Control and generator electrode with diaphragmCoulometer including generator electrode with diaphragm, Touch Control, 801 Magnetic Stirrer, and complete volumetric titration cell.Coulometry is the ideal method for water content determination in liquids, solids, and gases when it comes to water content determination in the trace range (10 µg to 10 mg absolute water). In addition, coulometry is an absolute method and thus no titer determination is necessary.Recommended coulometry measuring range: 10 µg - 200 mg absolute waterThe 852 Titrando controls not only coulometric, but also volumetric Karl Fischer titration.For use with OMNIS Software, tiamo software, or Touch Control unit. Compliance with GMP/GLP and FDA regulations such as 21 CFR Part 11, if required.
2.852.0160
852 Titrando with Touch Control and generator electrode without diaphragmCoulometer including generator electrode without diaphragm, complete volumetric titration cell, and Touch Control.Coulometry is the ideal method for water content determination in liquids, solids, and gases when it comes to water content determination in the trace range (10 µg to 10 mg absolute water). In addition, coulometry is an absolute method and thus no titer determination is necessary.Recommended coulometry measuring range: 10 µg - 200 mg absolute waterThe 852 Titrando controls not only coulometric, but also volumetric Karl Fischer titration.For use with OMNIS Software, tiamo software, or Touch Control unit. Compliance with GMP/GLP and FDA regulations such as 21 CFR Part 11, if required.
2.851.0020
851 Titrando with Touch Control and generator electrode with diaphragmCoulometer including generator electrode with diaphragm, Touch Control, and 801 Magnetic Stirrer.Coulometry is the ideal method for water content determination in liquids, solids, and gases when it comes to water content determination in the trace range (10 µg to 10 mg absolute water). In addition, coulometry is an absolute method and thus no titer determination is necessary.Coulometric titrations are carried out easily and quickly with the 851 Titrando.Recommended measuring range: 10 µg - 200 mg absolute waterFor use with OMNIS Software, tiamo software, or Touch Control unit. Compliance with GMP/GLP and FDA regulations such as 21 CFR Part 11, if required
2.851.0120
851 Titrando with Touch Control and generator electrode without diaphragmCoulometer including generator electrode without diaphragm and Touch Control.Coulometry is the ideal method for water content determination in liquids, solids, and gases when it comes to water content determination in the trace range (10 µg to 10 mg absolute water). In addition, coulometry is an absolute method and thus no titer determination is necessary.Coulometric titrations are carried out easily and quickly with the 851 Titrando.Recommended measuring range: 10 µg - 200 mg absolute water.For use with OMNIS Software, tiamo software, or Touch Control unit. Compliance with GMP/GLP and FDA regulations such as 21 CFR Part 11, if required