요청하신 페이지의 적용되는 국가로 리디렉션되었습니다
Metrosep A Supp 17 - 250/4.0

Metrosep A Supp 17 - 250/4.0

6.01032.430

Metrosep A Supp 17 - 250/4.0

en

6.01032.430

기능 개요

The Metrosep A Supp 17 - 250/4.0 combines high separating efficiency with a good price-performance ratio without requiring the use of a column oven. The polystyrene-divinylbenzene basic material used guarantees a long service life for the column. Complex separation tasks can be solved on this column.

기술 스펙

Housing materialPEEK
Carrier materialPolystyrene-divinylbenzene copolymer with quaternary ammonium groups
Particle size5 µm
Standard flow0.6 mL/min
Maximum pressure18 MPa
Maximum flow0.9 mL/min
pH range0–14
Column dimensions 250 x 4.0 mm
Temperature range10–70 °C
Standard temperature 25 °C

크로마토그램

  • 크로마토그램
  • 크로마토그램
  • 크로마토그램
이 필드는 필수입니다.
    • Threaded stopper
    • 6.2744.060
    • For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.
    • <p>For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.</p>
    • PCS
    • 2
    • Threaded stopper
    • 6.2744.060
    • For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.
    • <p>For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.</p>
    • PCS
    • 2
    • Metrosep A Supp 17 Guard/4.0
    • 6.01032.500
    • The Metrosep A Supp 17 Guard/4.0 reliably protects the Metrosep A Supp 17 analytical separation columns against contamination. Thanks to the "On Column Guard System", the guard column is very easy to handle. The guard column screws easily onto the analytical column. No tools are required.
    • <p>The Metrosep A Supp 17 Guard/4.0 reliably protects the Metrosep A Supp 17 analytical separation columns against contamination. Thanks to the "On Column Guard System", the guard column is very easy to handle. The guard column screws easily onto the analytical column. No tools are required.</p>
    • PCS
    • 1
    • Metrosep A Supp 17 S-Guard/4.0
    • 6.01032.510
    • The Metrosep A Supp 17 S-Guard/4.0 reliably protects the Metrosep A Supp 17 analytical separation columns against contamination. The guard column is simply connected to the separation column using capillary connections. No tools are required.
    • <p>The Metrosep A Supp 17 S-Guard/4.0 reliably protects the Metrosep A Supp 17 analytical separation columns against contamination. The guard column is simply connected to the separation column using capillary connections. No tools are required.</p>
    • PCS
    • 1
    • Metrosep A Supp 17 S-Guard - 50/4.0
    • 6.01032.530
    • The Metrosep A Supp 17 S-Guard 50/4.0 reliably protects the Metrosep A Supp 17 analytical separation columns against contamination. The guard column is simply connected to the separation column using capillary connections. No tools are required.
    • <p>The Metrosep A Supp 17 S-Guard 50/4.0 reliably protects the Metrosep A Supp 17 analytical separation columns against contamination. The guard column is simply connected to the separation column using capillary connections. No tools are required.</p>
    • PCS
    • 1