906 Titrando
2.906.0020
-
- Wrench
- 6.2739.010
- For exchange units.
- For exchange units.
- PCS
- 1
-
- 906 Titrando
- 1.906.0020
- High-end titrator for use with intelligent electrodes – iTrodes – withbuilt-in buret drive; dynamic (DET), monotonic (MET) and endpoint titration (SET), enzymatic and pH-STAT titrations (STAT), Karl Fischer titration (KFT); Measurement with ion-selective electrodes (MEAS CONC); Dosing functions with monitoring (DOS), Liquid Handling; four MSB connectors; two galvanically isolated measuring interfaces; USB connector;
- <p>High-end titrator for use with intelligent electrodes – iTrodes – with</p><ul><li>built-in buret drive</li><li>dynamic (DET), monotonic (MET) and endpoint titration (SET), enzymatic and pH-STAT titrations (STAT), Karl Fischer titration (KFT)</li><li>Measurement with ion-selective electrodes (MEAS CONC)</li><li>Dosing functions with monitoring (DOS), Liquid Handling</li><li>four MSB connectors</li><li><strong>two galvanically isolated measuring interfaces</strong></li><li>USB connector</li></ul>
- PCS
- 1
- Wrench
- 6.2739.010
- For exchange units.
- For exchange units.
- PCS
- 1
-
- 800 Dosino
- 2.800.0010
- The 800 Dosino is a drive with write/read hardware for intelligent Dosing Units. With fixed cable (length 150 cm).
- <p>The 800 Dosino is a drive with write/read hardware for intelligent Dosing Units. With fixed cable (length 150 cm).</p>
- PCS
- 1
- 801 Stirrer with stand
- 2.801.0040
- Magnetic stirrer including base plate, support rod and electrode holder for supplementing the Titrino plus, Dosimat plus, Titrandos, Sample Processors, 805 Dosimat and 780/781 pH meters as well as the 856 and 867 measuring modules. With permanently attached cable for MSB (Metrohm Serial Bus).
- <p>Magnetic stirrer including base plate, support rod and electrode holder for supplementing the Titrino plus, Dosimat plus, Titrandos, Sample Processors, 805 Dosimat and 780/781 pH meters as well as the 856 and 867 measuring modules. With permanently attached cable for MSB (Metrohm Serial Bus).</p>
- PCS
- 1
- 802 Stirrer for 804 Ti Stand
- 2.802.0040
- Rod stirrer including 6.1909.010 stirring propeller.
- Rod stirrer including 6.1909.010 stirring propeller.
- PCS
- 1
- 804 Ti Stand with stand
- 2.804.0040
- Titration stand and controller for 802 Rod Stirrer. The 804 Ti Stand together with the optional 802 Rod Stirrer provides an alternative to the magnetic stirrer. Ti Stand with base plate, support rod and electrode holder.
- Titration stand and controller for 802 Rod Stirrer. The 804 Ti Stand together with the optional 802 Rod Stirrer provides an alternative to the magnetic stirrer. Ti Stand with base plate, support rod and electrode holder.
- PCS
- 1
- 805 Dosimat
- 2.805.0010
- Dosing device for the Titrando and Sample Processors with read/write hardware for intelligent Exchange Units. With permanently attached cable. Without Exchange Unit.
- Dosing device for the Titrando and Sample Processors with read/write hardware for intelligent Exchange Units. With permanently attached cable. Without Exchange Unit.
- PCS
- 1
- 846 Dosing Interface
- 2.846.0010
- USB-capable control unit for connecting a maximum of four 800 Dosinos or 805 Dosimats for dosing and Liquid Handling tasks. A Touch Control or the connection to a PC with OMNIS Software, tiamo™, MagIC Net, viva, or 797 VA Computrace is required for operation.
- <p>USB-capable control unit for connecting a maximum of four 800 Dosinos or 805 Dosimats for dosing and Liquid Handling tasks. A Touch Control or the connection to a PC with OMNIS Software, <strong>tiamo</strong>™, MagIC Net, viva, or 797 VA Computrace is required for operation.</p>
- PCS
- 1
- 854 iConnect
- 2.854.0010
- The 854 iConnect – Electrode cable and measuring amplifier for intelligent "iTrodes" electrodes (cable length 150 cm).
- <p>The 854 iConnect – Electrode cable and measuring amplifier for intelligent "iTrodes" electrodes (cable length 150 cm).</p>
- PCS
- 1
- 900 Touch Control
- 2.900.0010
- Operating unit for the Titrandos, USB Sample Processors, 856 Conductivity Module, 867 pH Module and 846 Dosing Interface. Touch-sensitive, high-resolution color display, simple and intuitive operation, thanks to Favorites for direct method access. With integrated Ethernet interface for direct connection to the Internet and USB interface for connecting USB printers or a USB memory stick.Dialog languages: German, English, Chinese, French, Spanish, Portuguese, Russian, Korean, Polish and Italian.
- <p>Operating unit for the Titrandos, USB Sample Processors, 856 Conductivity Module, 867 pH Module and 846 Dosing Interface. Touch-sensitive, high-resolution color display, simple and intuitive operation, thanks to Favorites for direct method access. With integrated Ethernet interface for direct connection to the Internet and USB interface for connecting USB printers or a USB memory stick.</p><p>Dialog languages: German, English, Chinese, French, Spanish, Portuguese, Russian, Korean, Polish and Italian.<br/> </p>
- PCS
- 1
- Adapter red 2 mm plug / 4 mm socket
- 6.2103.130
- For connecting plug B (4 mm) to 2 mm socket.
- For connecting plug B (4 mm) to 2 mm socket.
- PCS
- 1
- Adapter black 2 mm plug / B socket 4 mm
- 6.2103.140
- For connecting plug B (4 mm) to 2 mm socket.
- For connecting plug B (4 mm) to 2 mm socket.
- PCS
- 1
- Electrode cable / 1 m / F
- 6.2104.020
- For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
- For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
- PCS
- 1
- Electrode cable for plug in head U/plug F, 2x2 mm B, 1m
- 6.2104.600
- For connecting electrodes with Metrohm plug-in head U to Metrohm instruments (socket F).
- For connecting electrodes with Metrohm plug-in head U to Metrohm instruments (socket F).
- PCS
- 1
- Remote Box MSB
- 6.2148.010
- Additional remote interface for the connection of devices that can be controlled via remote lines. With permanently attached cable.
- Additional remote interface for the connection of devices that can be controlled via remote lines. With permanently attached cable.
- PCS
- 1
- RS-232/USB box
- 6.2148.020
- Extends the Titrando, USB Sample Processors, Dosing Interface, Titrosampler by two RS-232 interfaces for connecting e.g. balances, PC, LIMS. Requires 6.2151.030 cable.
- <p>Extends the Titrando, USB Sample Processors, Dosing Interface, Titrosampler by two RS-232 interfaces for connecting e.g. balances, PC, LIMS. Requires 6.2151.030 cable.</p>
- PCS
- 1
- Mini USB adapter cable, 25 cm
- 6.2168.000
- Mini USB adapter cable for connecting one 854 iConnect to an 867 pH Module, 901 to 907 Titrandos and 916 Ti-Touch, 25 cm. The adapter cable remains plugged into the instrument as strain relief and the 854 iConnect is only plugged into and unplugged from the adapter cable.
- <p>Mini USB adapter cable for connecting one 854 iConnect to an 867 pH Module, 901 to 907 Titrandos and 916 Ti-Touch, 25 cm. The adapter cable remains plugged into the instrument as strain relief and the 854 iConnect is only plugged into and unplugged from the adapter cable.</p>
- PCS
- 1
- Exchange Unit 1 mL
- 6.3026.110
- Exchange Unit with integrated data chip with 1 mL glass cylinder and light protection. PCTFE/PTFE flat stopcock, FEP tubing connection, antidiffusion buret tip and standard amber glass reagent bottle.
- Exchange Unit with integrated data chip with 1 mL glass cylinder and light protection. PCTFE/PTFE flat stopcock, FEP tubing connection, antidiffusion buret tip and standard amber glass reagent bottle.
- PCS
- 1
- Exchange Unit 5 mL
- 6.3026.150
- Exchange Unit with integrated data chip with 5 mL glass cylinder and light protection. PCTFE/PTFE flat stopcock, FEP tubing connection, anti-diffusion buret tip and standard amber glass reagent bottle.
- Exchange Unit with integrated data chip with 5 mL glass cylinder and light protection. PCTFE/PTFE flat stopcock, FEP tubing connection, anti-diffusion buret tip and standard amber glass reagent bottle.
- PCS
- 1
- Exchange Unit 10 mL
- 6.3026.210
- Exchange unit with integrated data chip with 10 mL glass cylinder and light protection. PCTFE/PTFE flat stopcock, FEP tubing connection, anti-diffusion buret tip and standard amber glass reagent bottle.
- Exchange unit with integrated data chip with 10 mL glass cylinder and light protection. PCTFE/PTFE flat stopcock, FEP tubing connection, anti-diffusion buret tip and standard amber glass reagent bottle.
- PCS
- 1
- Exchange Unit 20 mL
- 6.3026.220
- Exchange unit with integrated data chip with 20 mL glass cylinder and light protection. PCTFE/PTFE flat stopcock, FEP tubing connection, anti-diffusion buret tip and standard amber glass reagent bottle.
- <p>Exchange unit with integrated data chip with 20 mL glass cylinder and light protection. PCTFE/PTFE flat stopcock, FEP tubing connection, anti-diffusion buret tip and standard amber glass reagent bottle.</p>
- PCS
- 1
- Exchange unit 50 mL
- 6.3026.250
- Exchange unit with integrated data chip with 50 mL glass cylinder and light protection. PCTFE/PTFE flat stopcock, FEP tubing connection, antidiffusion tip and standard amber glass reagent bottle.
- <p>Exchange unit with integrated data chip with 50 mL glass cylinder and light protection. PCTFE/PTFE flat stopcock, FEP tubing connection, antidiffusion tip and standard amber glass reagent bottle.</p>
- PCS
- 1
- 807 Dosing Unit 2 mL
- 6.3032.120
- 807 Dosing Unit with integrated data chip with 2 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.
- <p>807 Dosing Unit with integrated data chip with 2 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.</p>
- PCS
- 1
- 807 Dosing Unit 5 mL
- 6.3032.150
- 807 Dosing Unit with integrated data chip with 5 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.
- <p>807 Dosing Unit with integrated data chip with 5 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.</p>
- PCS
- 1
- 807 Dosing Unit 10 mL
- 6.3032.210
- 807 Dosing Unit with integrated data chip with 10 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.
- <p>807 Dosing Unit with integrated data chip with 10 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.</p>
- PCS
- 1
- 807 Dosing Unit 20 mL
- 6.3032.220
- 807 Dosing Unit with integrated data chip with 20 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.
- <p>807 Dosing Unit with integrated data chip with 20 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.</p>
- PCS
- 1
- 807 Dosing Unit 50 mL
- 6.3032.250
- 807 Dosing Unit with integrated data chip with 50 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.
- <p>807 Dosing Unit with integrated data chip with 50 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.</p>
- PCS
- 1