- AN-V-174Arsenic in zinc plant electrolyte
The concentration of As(total) in zinc plant electrolyte is determined by anodic stripping voltammetry (ASV) on a lateral gold electrode in HCl electrolyte. Due to the high excess of zinc in the sample the deposition potential has to be adapted. A second potential approx. 100 mV more negative than the arsenic signal has to be applied to selectively oxidize interfering antimony. For sample preparation the sample was passed through a cation exchange column to reduce the concentration of zinc in the measuring solution.
- AN-C-186Sodium in potassium sodium tartrate as per USP
Within the scope of the USP monograph modernization, sodium is determined in potassium sodium tartrate applying cation chromatography with direct conductivity detection. The USP41 monograph for «Potassium sodium tartrate» does not yet mention an assay for sodium. The separation is performed on a Metrosep C 6 - 150/4.0 column (L76). The assay of potassium is performed with two commercially available products according to USP definitions. All acceptance criteria are fulfilled. See AN-C-182 for the respective determination of potassium. Apllying this method allows to determine sodium and potassium simultaneously according to USP.
- 410000005-BPortable Raman Instrumentation for SERS Applications
For SERS developers and end users of SERS for specific applications to investigate low concetation levels of compounds, the centerpiece of their technological platform must be a Raman setup that provides reliable lab grade performance and is affordable and portable, allowing them to tackle real world problems. The portable i-Raman Plus system coupled with a BAC151 video microscope sampling accessory provides an ideal setup. With the performance and flexibility of use with different laser spot size and power for SERS research.
- 410000051-BIdentification of microplastics with Raman microscopy
Research laboratories must expand their capabilities to routinely analyze candidate microplastics from environmental samples to determine their origin and help predict biological impacts. Spectroscopic techniques are well suited to polymer identification. Laboratory Raman spectroscopy is an alternative to confocal Raman microscopes and Fourier transform infrared (FTIR) microscopes for quick identification of polymer materials. Raman microscopy was used to identify very small microplastic particles in this Application Note.
- 410000061-AIdentification of Starting Materials in Pharmaceutical industry using STRam®-1064
100% starting materials identification testing is one of the FDA’s directives as per 211.84 for FDA regulated industries such as Pharmaceutical, Vaccines, Cosmetics, Tobacco, Animal veterinary products, Food, etc. STRam®-1064 is a Raman analyzer uniquely suited for this purpose. It measures samples through thick packaging materials such as plastics, multilayer kraft paper sacks, and HDPE containers. A long wavelength laser is used to suppress fluorescence. The ID algorithm isolates the sample signature by subtracting that of the packaging material and compares that with library spectra to achieve identification.
- AN-NIR-118Quantification of cotton content in textiles by near-infrared spectroscopy
This Application Note demonstrates how the OMNIS NIR Analyzer Solid quickly determines the cotton content in various textile products within just 30 seconds.
- AN-RS-009Verification of fatty acids in functional foods and cosmetics
Determination of the identity and purity of ingredients is essential for the product quality of functional foods (neutraceuticals) and cosmetics. It prevents the utilization of inferior substances in the production process and thus avoids expensive delays and out-of-spec products. This Application Note describes the identification and checking of fatty acids in functional foods and cosmetics using the Metrohm Instant Raman Analyzer MIRA P.
- AN-RS-044Optimize raw material identification and verification (RMID) with MIRA P
This Application Note explains how to scale MIRA P usage across an entire manufacturing operation by transferring models between different MIRA P instruments.
- AN-SENS-001Quantification of paracetamol with square wave voltammetry
This Application Note demonstrates square wave voltammetry for sensitive, reproducible quantification of paracetamol using a screen-printed electrode and INTELLO.
- AN-T-111Saponification value of edible oils
The saponification value evaluates edible oil quality by indicating the average molecular weight of fatty acids. Its titrimetric determination in canola and olive oil is described here.
- WP-035Facile Verification of Edible Oils with Raman Spectroscopy
Edible oils comprise a significant portion of any diet, and they also have important roles in the production of foods, cosmetics, and skincare products. For these reasons, a convenient and accurate method for materials identification of a variety of fats and oils is highly desirable. Historically, authentication of fats and oils was performed through intensive laboratory techniques involving chromatographic methods. Here, Raman spectroscopy combined with Principle Component Analysis (PCA) has been used for materials identification with 16 different edible oils, with excellent results. Raman is an ideal technique for evaluation of fats, as carboncarbon double- and single-bonds give strong Raman signals. PCA analysis in combination with Raman spectroscopy is a powerful tool for qualification and verification of different fats and oils, as there are few visual differences between spectra of edible oils.
- WP-069(Un)Grounded: Grounded and floating measurements and their application in electrochemical research
In this White Paper, details of the electronic (PGSTAT) and electrochemical cell grounding are presented together with the necessity of using a floating PGSTAT for different application and experimental examples. Due to the wide variation of experimental requirements and kinds of electrochemical cells, the use of an electrochemical instrument with a selectable floating feature (such as VIONIC) which brings additional versatility to the user is recommended.
- AN-I-017Potassium in electrolyte powder – Fast and economical determination by standard addition
The determination of the potassium content in foodstuffs plays a major role in the food and dietary supplement industry, as potassium is an essential mineral nutrient for humans. It is an important intracellular cation and also plays a important role in processes within cells, where it is involved in the regulation of numerous body functions like blood pressure, cell growth and muscle control.As a dietary supplement, potassium is present in e.g., electrolyte powder, electrolyte drinks and food supplements. To quantify the potassium content in such products, e.g. flame photometry can be used. In this work, an alternative, ion measurement by standard addition, is described, which is fast, inexpensive and simple to use.
- AN-I-016Potassium in fruit juice and wine – Fast and economical determination by ion measurement
Determination of the potassium content plays a major role in the food and beverage industry. Potassium is an essential mineral nutrient for humans. It is an important intracellular cation and also plays an important role in processes withincells, where it is involved in the regulation of numerous body functions like blood pressure, cell growth and muscle control.To declare the potassium content of drinks and food, it is usually determined by flame photometric method. However, flame photometry is linear only over a limited concentration range, and often sample dilution is necessary. Furthermore, the instrumentation is rather complex and expensive to buy and maintain. The ion measurement method presented here is a fast, less expensive, and reliable alternative to determine potassium content in beverages.
- 410000008-ARaw Materials Identification through Multiple Polyethylene Bags
The NanoRam is able to test material through multiple layers of transparent plastic bags. Postive identification of material on PE bags from 1 to 9 layers were obtained, demonstrating minimum interference from the PE bags on the material identification result.
- 410000016-AQuantification of Urea in Ethanol by Raman Spectroscopy
Urea in widely employed as a nitrogen-release fertilizer with more than 90 % of urea production destined for agricultural applications. Urea is also known to form complexes with fatty acids, which have been employed for separation of complex mixtures and purification processes. In this application note, we present the quantification of the concentration of urea in ethanol by Raman Spectroscopy and show how this method can be employed for determining the percentage of urea in a solid inclusion compound with stearic acid.
- 410000019-BQuantification of methanol in contaminated spirits with Raman
Methanol, often present in spirits prepared with industrial solvents like wood alcohol, can lead to blindness and even death when ingested. After an incident involving methanol-laced alcohol in the Czech Republic, they adopted Raman spectroscopy as the preferred method for identifying and quantifying methanol in contaminated spirits, following an exhaustive study using various screening tools. This Application Note discusses the reasons why Raman spectroscopy is the ideal choice for this application and shows a real-world example of Raman analysis of methanol-laced rum.
- 410000024-BRaman solution suite for forensics applications
Law enforcement personnel, laboratory technicians, crime scene investigators and many others face a significant challenge for identification of materials in a forensic investigation.Traditionally, technicians used multiple forms of identification in order to collect results from various forms of forensic samples. Although certain technologies are ideal for precise laboratory identification, many technologies, such as Raman spectroscopy, can be successfully used for identification of multiple forensic sample types either directly in the field or in the lab. Raman spectroscopy is classified as a Category A analytical method by the Scientific Working Group for the Analysis of Seized Drugs (SWGDRUG; Version 7.1, 2016).
- 410000028-AIdentification of Additives used in the Pharmaceutical and Food Industries with the NanoRam Handheld Raman Spectrometer
Today’s Raman instrumentation is faster, more rugged, and less expensive than previous instrumentation.The design of high performance, portable and handheld devices has introduced the technology to new application areas that were previously not possible with older, more cumbersome instruments. Handheld Raman instruments such as the NanoRam® from B&W Tek are well-suited for pharmaceutical applications such as the testing of raw materials, verification of final products and the identification of counterfeit drugs due to the technique’s extremely high molecular selectivity.
- 410000049-ANanoRam®-1064 Fast Facts: Botanical Verification
Botanicals are derived from plant materials and used for their medicinal and therapeutic properties in the nutraceuticals market. They are not as heavily regulated by the U.S. Food and Drug Administration (FDA) like the pharmaceuticals drug market, but they are required to follow Good Manufacturing Practice (GMP Requirements).The NanoRam®-1064 is an asset for pharmaceutical identity testing, minimizing fluorescence generated by typical handheld Raman systems with 785 nm lasers. As such, the NanoRam®-1064 is used here to identify botanicals that would normally fluoresce with a 785 nm laser.
- AB-125Simultaneous determination of calcium, magnesium, and alkalinity by complexometric titration with potentiometric or photometric indication in water and beverage samples
This bulletin describes the determination of calcium, magnesium, and alkalinity in water by complexometric titration with EDTA as titrant. It is grouped into two parts, the potentiometric determination and the photometric determination.There are multiple definitions of the different types of water hardness. In this Application Bulletin, the following definitions are used: alkalinity, calcium hardness, magnesium hardness, total hardness, and permanent hardness. Explanations of these definitions and other expressions are provided in the Appendix.Determination of alkalinity during the photometric part is carried out in a separate acid-base titration before the complexometric titration of calcium and magnesium in water. Permanent hardness can be calculated from these values. The determination of calcium and magnesium in beverages (fruit and vegetable juices, wine) is also described.The photometric part includes the determinations of total and calcium hardness and thereby indirectly magnesium hardness using Eriochrome Black T and calconcarboxylic acid as indicators (in accordance with DIN 38406-3).
- AB-130Chloride titrations with potentiometric indication
Potentiometric titration is an accurate method for determining chloride content. For detailed instructions and troubleshooting tips, download our Application Bulletin.
- AB-200Acid value, hydroxyl value, and isocyanates in raw materials for the fabrication of plastics – Determination by automatic potentiometric titration according to various standards
Polyurethanes are one of the most commonly used types of plastic. They are produced by the reaction of raw polyols with isocyanates. Depending on the starting material a wide variety of plastics can be obtained. The determination of the acid value, hydroxyl value, and isocyanate content plays an important part in the analysis of raw materials for plastics.The acid number of polyol raw material is usually used in quality control to ensure batch-to-batch uniformity. Additionally it is used as correction factor for calculating the true hydroxyl number. In this Application Bulletin the determination of the acid number according to ASTM D4662 and ASTM D7253 is described.One raw material for polyurethanes are polyols. Polyols contain multiple hydroxyl groups. Therefore, hydroxyl number of a raw material directly correlates to the amount of polyols present and it is thus an important quality control parameter. In this Application Bulletin the determination of the hydroxyl number according to ASTM E1899 and DIN 53240-3 is described.As polyols react stoichiometrically with isocyanates, the knowledge of the isocyanate content is an important quality parameter for the production of polyurethanes. In this document the determination according to EN ISO 14896 method A, ASTM D5155 method A and ASTM D2572 is described.
- AN-NIR-027Identification of 46 medicinal and aromatic plants for the cosmetics and pharmaceuticals industry
This Application Note shows how, with the help of Vis-NIR spectroscopy and a special plant library, 46 different medicinal and aromatic plants, e.g., Organicum majoricum and Tilia cordata, can be conveniently identified on the basis of their spectrum. In comparison with alternative methods for the determination of plants, which are elaborate and require experienced scientists for their performance, the Vis-NIR method permits rapid and uncomplicated identification.
- AN-NIR-042Quantification of USP heparin units using near-infrared spectroscopy
Heparin acts as an efficient anticoagulant and, in addition to direct injection, is also used as a lock-flush solution for rinsing catheters. Vis-NIR spectroscopy can be used to determine the strength of contaminated and purified heparin. This Application Note demonstrates that heparin strength can be determined reliably with Vis-NIR spectroscopy.
- AN-NIR-046Qualification of droplet morphology in hair conditioner by Vis-NIR spectroscopy
Vis-NIR spectroscopy is used to determine the droplet morphology in hair conditioner. This Application Note shows that near-infrared (NIR) spectroscopy can be used to distinguish between unprocessed and processed hair conditioner and to qualify quality parameters such as the droplet size.
- AN-NIR-049Quantification of TAED, PCS and protease enzyme in detergents using Near-infrared spectroscopy
Visible near-infrared (Vis-NIR) spectroscopy can be used as a fast and accurate analytical method for the quantification of different analytes and active ingredients in detergents, such as tetraacetylethylendiamin (TAED), sodium percarbonate (PCS), and enzymes. This Application Note shows how NIRS can be used for multi-constituent analyses in detergents in a single measurement.
- AN-NIR-050Quantification of active ingredients in shampoo using near-infrared spectroscopy (NIR)
Near-infrared spectroscopy (NIRS) was used in a preliminary study as a fast and accurate method for the quantification of different preservatives and active ingredients in liquid shampoo. This Application Note shows how this analytical method allows the simultaneous determination of several constituents in shampoo in a single measurement.
- AN-NIR-056Quantification of five effective components in pesticides by visible near-infrared spectroscopy
This Application Note shows that visible near-infrared spectroscopy (Vis-NIRS) can be used for the quantification of five effective insecticide and herbicide components (Abamectin emulsifiable concentrate (EC), Emamectin EC, Cyhalothrin EC, Cypermethrin and Glyphosate) in pesticides. Vis-NIRS is an excellent alternative to conventional lab methods, saving both cost and time.
- AN-NIR-057Quantification of Baicalin content in scutuellaria baicalensis powder (herbal supplements) by Vis-NIRS
This Application Note shows that visible near-infrared spectroscopy (Vis-NIRS) can be used for the quantification of Baicalin content in herbal supplements. Vis-NIRS is a good alternative to the conventional lab method (HPLC) and can save both cost and time.
- AN-NIR-058Quantification of color intensity of diluted textile dye by visible near-infrared spectroscopy
This Application Note shows that the visible range of the Metrohm Vis-NIR analyzer can be used to quantify the color intensity of dyes, providing comparable results to the reference analysis UV-Vis. The NIR region can be used in addition to distinguish between different dye types or different suppliers and can identify impurities in the undiluted dyes during raw material control. The combination of the visible and near-infrared wavelength ranges offer the benefit that only one analyzer is required to receive results on multiple parameters in a 30-seconds-scan results on both cost and time saving.
- AN-NIR-070Quantification of nicotine and glycerin in e-liquids using visible near-infrared spectroscopy
This Application Note describes a fast method for the simultaneous quantification of nicotine and glycerin in liquid mixtures used for electronic cigarettes. With visible near infrared spectroscopy (VIS-NIRS), results are available without sample preparation, thus making VIS-NIRS highly suited for fast quality control.
- AN-NIR-122Quantification of water in lactose with the OMNIS NIRS Analyzer
This Application Note shows how easy it is to determine water content in the pharmaceutical excipient lactose with reagent-free near-infrared spectroscopy.
- AN-PAN-1053Monitoring of DOTP production via esterification with inline analysis
This Process Application Note presents a way to closely monitor multiple parameters simultaneously during the dioctyl terephthalate production process with near-infrared spectroscopy.
- AN-RS-002Identification of structurally very similar sugars using a portable Raman spectrometer
This Application Note describes the Raman spectroscopy identification of sugars such as D-galactose, D-glucose, D-maltose, D-mannose, D-sorbitol, fructose, sucrose and inositol. Rapid and non-destructive determination takes place after a suitable spectrum database has been created. Measurements with the portable Raman spectrometer Mira M-1 require no sample preparation and provide immediate and unambiguous results.
- AN-RS-003Identification of conventional organic solvents with handheld Raman spectrometers
This Application Note describes the rapid and non-destructive identification of conventional organic solvents using hand-held Raman spectrometers. Measurements with the handheld Raman spectrometer Mira M-1 require no sample preparation and provide immediate and unambiguous results.
- AN-RS-007Identification of polymer masterbatches with Raman spectroscopy
Handheld Raman spectroscopy enables rapid polymer masterbatch analysis, while Metrohm’s XTR® algorithm mitigates fluorescence interference for accurate additive identification.
- AN-RS-010P-test verification of Equate cold tablets and comparison with Alka-Seltzer
Producers of generic brands offer cosmetics, medicines and other goods in competition with name brands, often at a lower price point. This lower cost may reflect a lack of research, development, and advertising costs, but should never imply lower quality, especially in the case of over-the-counter drugs. As an example, Equate (a Walmart brand) effervescent cold tablets promise customers the same active ingredients in the same proportions and with identical effectiveness as Alka-Seltzer, at a much lower price. This Application Note demonstrates that Raman spectroscopy can successfully verify that these competing cold tablets are not identical. The process of ingredient verification involves a p- test, which measures the acceptable variability of a sample spectrum, as compared to a representative training set.
- AN-RS-011Improving verification with Orbital Raster Scan technology
Raman spectrometers use tightly focused beams to produce high resolution spectra, but fail at analyzing heterogeneous substances because they cannot spatially target all components. ORSTM (Orbital Raster Scan) increases the interrogation area on a sample while maintaining high spectral resolution. Effervescent cold medicines, for example, contain many active ingredients in each heterogeneous tablet. Traditional identification and verification techniques require the collection of several spectra at different points on the tablet. Mira spectrometers equipped with ORS capture a large interrogation area in a very short time, analyzing all of the ingredients in a single scan.
- AN-RS-032Raman and SERS identification of a combination prescribed opioid
Handheld Raman spectrometers are valued for their ability to provide onsite material identification in seconds. In the case of combination pharmaceuticals, a single tablet contains more than one active ingredient in different proportions. MIRA DS is uniquely capable of identifying multiple compounds in such tablets by using Raman to identify the major component and SERS (surface-enhanced Raman spectroscopy) for the minor component. This application describes quick, dual analysis of a prescription medication containing acetaminophen and hydrocodone. The application is easily extrapolated to the study of street drugs.
- AN-RS-033Raman and SERS identification of YABA, a popular street drug
Yaba, produced in Southeast Asia, is a popular drug of abuse and is actively targeted by police squads. Two strong and highly addictive stimulants make up Yaba: caffeine, which comprises up to 60% of each tablet, and methamphetamine at approximately 20%. Identifying these two active ingredients in different proportions in a colorful tablet with other excipients could be an analytical nightmare. With handheld Raman, bulk material identification is achieved in seconds onsite with simple point-and-shoot analysis. SERS (surface-enhanced Raman spectroscopy) analysis is used to detect the minor component in mixtures without interference from fillers, dyes, and coatings. MIRA DS is uniquely capable of both analyses—Raman testing positively identifies caffeine in Yaba, while methamphetamine can be detected with SERS sampling. This application describes quick, dual analysis of Yaba tablets with MIRA DS.
- AN-RS-047Rapid phenotypic identification of microorganisms with Raman
Raman spectroscopy offers a fast, nondestructive way to identify microorganisms and analyze metabolites directly from culture media, without complex genetic sequencing.
- AN-S-278Anions in sodium tetraborate with Metrohm Inline Acidification, Metrohm Inline Matrix Elimination, and Metrohm Inline Calibration
Determination of fluoride, chloride, phosphate, and sulfate in sodium tetraborate using anion chromatography with conductivity detection after sequential suppression. Inline acidification is applied to convert tetraborate into boric acid which is not retained on the preconcentration column. Inline calibration minimizes the anion contamination.
- AN-S-374Fluoride Identification and Assay in «Sodium Fluoride Oral Solution» by Ion Chromatography as per USP
Fluoride is commonly used in dental products to help prevent tooth decay. If the products are intended to prevent the formation of cavities (carries), then it is regulated by the US Food and Drug Administration (USFDA) as an Over-the-Counter (OTC) Drug. Previously, the assay of Fluoride in oral solution was done by Ion selective electrode and identification was done by tedious wet chemistry method. USP has updated this monograph for Assay and identification tests with Ion Chromatography using L46 packing. The Metrosep A Supp 1 - 250/4.6 column fulfills all USP acceptance criteria. It therefore is a viable alternative separation column for the determination of sodium fluoride in oral solutions.
- AN-T-180Determination of the acid number and base number in used motor oil by differential amplification
For titrations in low conducting media (e.g., non-aqueous titrations) the potentiometric indication can be disturbed by interfering signals. When differential amplification is used, these signals are measured by both the measuring electrode and the reference electrode and thus neutralized. It is therefore possible to obtain smoother titration curves and more reproducible results.This Application Note describes the potentiometric determination of the acid number and base number in used motor oil by the differential amplification using a fully automated OMNIS system.
- BWT-4904The Benefits of Raman Spectroscopy for the Identification and Characterization of Polymers
Raman spectroscopy is a quick nondestructive method for the direct identification of plastics. It can also be used for the analysis of flame retardants, lubricants and other additives. Coupled with chemometric software, quantitative and advanced qualitative analyses can be performed.
- BWT-4906Rapid Raw Material Identification for Formulation Compounds Using Handheld Raman Technology
The raw materials whey, sorbitol, stearic acid, and calcium phosphate dihydrate dibasic all show very distinctive, unique Raman signatures, which indicates that Raman spectroscopy is the ideal technology for identification of these materials. The PCA model-based method provides reliable specificity to successfully identify these nondestructively in plastc samples bags using the NanoRam.
- BWT-4908The Benefits of a High-Performance Handheld Raman Spectrometer for the Rapid Identification of Pharmaceutical Raw Materials
The principles and benefits of Raman are presented in terms of advances that make handheld Raman an integral tool for pharmaceutical manufacturers to comply with incoming material testing requirements. Examples of the NanoRam for positive identification of excipients including celluloses and sugars illustrate the selectivity of Raman.
- WP-024Verification, p-values, and Training Sets for the Mira P
This white paper differentiates between methods for identification of unknowns and verification of known materials. The goal of this publication is, ultimately, to inform the user of the capabilities of the handheld Metrohm Raman Mira P system. Best practices for building robust training sets for materials verification with Mira P can also be found here.
- WP-043Instrument Calibration, System Verification, and Performance Validation for Metrohm Instant Raman Analyzers (Mira)
Analytical Instrument Qualification (AIQ) according to the United States Pharmacopeia (USP) ensures that instruments perform as intended and users may have confidence in data quality. As the Pharma industry adopts handheld Raman instruments for incoming materials identification and verification, producers of such systems must provide suitable calibration and validation routines. Upon completion of these tests, end users are assured that all measurements are in accordance with agreed standards at Metrohm Raman, we have sophisticated AIQ routines in place to confirm the quality of your results.
- WP-064Illicit Drug Trafficking and Border Control with Mira DS: Safe Fentanyl Identification
Like any defense and security professional, border agents must quickly and accurately identify suspicious substances at the point of contact. When that substance is fentanyl, which is deadly in microdoses, the stakes are even higher. The Mira DS handheld Raman system from Metrohm Raman offers safe, no-contact identification of over 200 fentanyl analogues. Mira DS protects border agents, while they protect citizens from deadly narcotics, drug smugglers, and illegal entry of goods.
- WP-093Significant cost savings through dynamic ventilation during nitrification in wastewater treatment
This White Paper gives an overview of the energy-intensive nitrification process that converts ammonia into less harmful nitrogen compounds at wastewater treatment plants (WWTPs). It displays the results from a field test at a WWTP, showcasing the positive influence of single-method process analyzers on the efficiency of the nitrification process.
- AN-SENS-002Detection of heavy metals with differential pulse voltammetry
This Application Note presents DPV as a sensitive, selective method for detecting heavy metals in water, detailing setup, parameters, and advantages over other techniques.
- AN-EC-041Studying nickel deposition with EQCM-D and EC-Raman
This application note demonstrates EQCM D for simultaneous mass and dissipation analysis of Ni(OH)₂ electrodeposition.
- 410000047-ANanoRam-1064 Fast Fact: Raw Material Verification of Cellulose and its Derivatives
Cellulose is a common naturally-derived raw excipient found in the majority of pharmaceutical products. Raw material testing is required to ensure that consumers are receiving quality cellulose and its derivatives. The NanoRam®-1064 is an asset for pharmaceutical identity testing, minimizing fluorescence generated by typical handheld Raman systems with 785 nm lasers. As such, the NanoRam®-1064 is used here to identify cellulose derivatives that would normally fluoresce with a 785 nm laser.
- 410000050-AApplication Fast Fact Historic Stamp Inks
Stamps are cultural heritage objects that provide an invaluable amount of historical information. There is an increase of counterfeit historical inks and it is imperative that fraudulent stamps can be identified and removed from the market. The portable Raman i-Raman EX® with a 1064 nm laser is used because it minimizes the fluorescence of the ink. The i-Raman EX® also has the functionality of low laser power reduction down to 1% to prevent sample burning and the Raman video microscope system analyzes the smallest of details, which is imperative for cultural heritage analysis of an 1885 historical envelope.
- AN-EC-034Ion-selective electrodes based on screen-printed technology
Advances in polymeric membranes and screen-printed technologies have enabled miniaturized, portable potentiometric sensors ideal for point-of-care analysis.
- AN-PAN-1044Online trace analysis of amines in the alkaline water-steam circuit of power plants
Neutralizing amines are added to adjust pH levels within the water-steam circuit of power plants to avoid corrosion-inducing conditions. This preventive maintenance can reduce costly and critical downtimes due to corrosion, however frequent monitoring of the amine chemistry is necessary to ensure conditions stay optimal. The 2060 IC Process Analyzer featuring the Metrohm intelligent Partial Loop Technique (MiPT) option is ideal for this application, with the ability to measure trace amounts of the analytes precisely and reliably through an automated method. The benefit of using IC is that multiple analytes can be monitored simultaneously, and here the ability to measure the presence of sodium next to the high ammonium or amine concentrations could indicate that cooling water is seeping into the circuit, indicating a problem upstream.
- EB-003Ion chromatography for food and beverage analysis
Efficiently analyze food products with ion chromatography (IC). Discover its robust applications in quality control for beverages, food additives, and dairy.
- AN-C-194IC Assays for Calcium and Magnesium according to USP
Calcium carbonate has a wide applicability in the pharmaceutical industry as an excipient and also as an active ingredient, and in the food industry as a major dietary supplement. The U.S. Pharmacopoeia (USP) monographs for calcium and magnesium carbonates tablets as well as calcium carbonate and magnesia chewable tablets currently describe manual titration as the assay procedure for calcium and magnesium. The USP has embarked on a global initiative to modernize many of the existing monographs across all compendia. In response to this initiative, two alternative analytical methods were developed to determine the analytes calcium and magnesium. This Application Note presents ion chromatography (IC) procedures using conductivity detection that provide better accuracy and specificity and are suitable for the intended purpose. These validated IC methods (according to USP General Chapter <1225>) offer a significant improvement to the existing assays because they can simultaneously determine both analytes calcium and magnesium, saving both time and effort.
- AN-PAN-1045Online monitoring of copper corrosion inhibitors in cooling water
Copper is used widely in industrial cooling water systems for its heat transfer properties, although it is susceptible to corrosion. Corrosion can cause a loss of efficiency and eventually a failure of equipment, leading to costly maintenance, replacement, and downtime. Corrosion inhibitors (triazoles) can be added to the water chemistry, which form sparingly soluble protective layers on the surface of the metal. Triazole concentrations must be maintained to protect the copper, which necessitates regular concentration determinations in cooling water. The 2060 IC Process Analyzer with UV/VIS detection is well-suited for this application, able to precisely and reliably measure multiple ionic and UV-active compounds simultaneously in cooling water.
- AN-PAN-1059Online analysis of strontium and barium in high purity brine
This Process Application Note describes a method to determine the strontium and barium concentration in brine as early detectors ofmembrane fouling via online process ion chromatography. Using this multiparameter analytical technique can help reduce the risk of premature membrane fouling and avoid unexpected maintenance and high utility costs with 24/7 automated analysis.
- 410000001-CChoosing the Most Suitable Laser Wavelength For Your Raman Application
Raman instrumentation can use lasers of different laser excitation, giving the same Raman spectrum for a sample. This paper presents the specific strengths and weaknesses that different excitation wavelengths provide, allowing a user to optimize the measurement of different samples by their choice of Raman excitation laser wavelength.
- 410000014-BRaman Spectroscopy as a Tool for Process Analytical Technology
This article demonstrates the utility of portable Raman spectroscopy as a versatile tool for process analytical technology (PAT) for raw material identification, in-situ monitoring of reactions in developing active pharmaceutical ingredients (APIs), and for real-time process monitoring. Raw material identification is done for verification of starting materials as required by PIC/S and cGMP, and can be readily done with handheld Raman. Portable Raman systems allow users to make measurements to bring process understanding and also provide proof of concept for the Raman measurements to be implemented in pilot plants or large-scale production sites. For known reactions which are repetitively performed or for continuous online process monitoring of reactions, Raman provides a convenient solution for process understanding and the basis for process control.
- 410000025-AIdentification of Forensic Fabrics Using a Portable Raman Spectrometer
At a crime scene, a police officer collects a fiber sample that may prove to be invaluable evidence in identifying a criminal or exonerating an innocent person. In recent years, Raman spectroscopy has been studied extensively for forensic fiber analysis because of the high selectivity of Raman signatures, non-destruction nature of the test, and the ability to conduct the analysis without any sample preparation. The Raman spectrum can be measured directly on fabrics or fibers mounted on glass slide with very little interference from the mounting resin or the glass.
- 410000029See-through ID with Raman technology
Metrohm’s ST Raman technology enables fast, contactless identification of substances through opaque packaging, expanding safe, field-ready use of Raman spectroscopy.
- 410000033-AMicro-Raman Spectroscopy in Thin Section Analysis of Rock Mineralogy
Correct identification of mineral phases in rock thin sections is essential to petrographic and petrologic analysis of rocks. Portable Raman coupled to an optical microscope gives chemical information along with the optical images to give a higher certainty of identification than traditionally used optical micropcopy alone.
- 410000038-AMaterial ID through Dark Brown PVBag
This technical note is to demonstrate the NanoRam material identification through dark brown plastic bags. NanoRam is shown to work for material identification inside dark brown polyvinyl bag.
- 410000052-ASee-Through Measurements of Illicit Substances in Commercial Containers with the TacticID®-1064 ST
The TacticID®-1064 ST is a 1064 nm handheld Raman system designed for law enforcement officials, first responders, and customs and border protection officers for rapid field identification of illicit substances such as narcotics, explosives, and other suspicious materials.The TacticID-1064 ST is specially designed with see-through Raman functionality to measure materials through both transparent and opaque containers. These through-barrier measurements remove the need for active sampling of potentially dangerous compounds such as fentanyl, leading to safer operations and reduced wait time for clear results.
- 410000057-ATechnical Note: Spectral Preprocessing for Raman Quantitative Analysis
Raman spectroscopy’s use for process analytics in the pharmaceutical and chemical industries continues to grow due to its nondestructive measurements, fast analysis times, and ability to do both qualitative and quantitative analysis. Spectral preprocessing algorithms are routinely applied to quantitative spectroscopic data in order to enhance spectral features while minimizing variability unrelated to the analyte in question. In this technical note we discuss the main preprocessing options pertinent to Raman spectroscopy with real applications examples, and to review the algorithms available in B&W Tek and Metrohm software so that the reader becomes comfortable applying them to build Raman quantitative models.
- 8.000.6020Titrimetric analyses of biofuels
Several testing methods such as the determination of the acid and the iodine numbers in biodiesel as well as the quantification of sulfate and chloride in bioethanol are described.
- 8.000.6055Liquid handling applied to automated sample preparation in liquid chromatography
In routine chemical analysis, the predominant challenge involves a higher sample throughput, improved reproducibility, liquid handling flexibility and reduced personnel costs. In response to these requirements, the 872 Extension Module Liquid Handling in combination with the MagIC NetTM software and the well-proven Dosino technology expands the possibilities of inline sample preparation and opens up new fields of application. Among others, the module can be used, together with an optional mixing vessel, for pH adjustments, pre-column derivatizations, or the mixing of solutions.As a representative of an inline sample preparation technique, this poster describes the performance of precise dilutions. By using only one single stable standard solution, multi-point calibration curves can be automatically recorded by diluting a concentrated standard in an external vessel.
- 8.000.6076Sequential suppression for conductivity detection in ion chromatography
The poster describes how different suppressors (MSM and MCS) work and mentions possible applications.
- 8.000.6080Thermometric titration – the missing piece of the titration puzzle
Thermometric titration can solve application problems that potentiometry cannot solve at all, or at least not satisfactorily.
- AB-025Coatings on silver electrodes
Ag electrodes are used for the indication of the potentiometric endpoints in precipitation titrations between silver and halide or sulfide ions. A coating on the silver ring may increase the sensitivity of the electrode and can thus reduce the limit of detection. This is why a variety of coated Ag electrodes are commercially available. This bulletin describes how the silver ring of Ag electrodes can be coated with AgCl, AgBr, AgI or Ag2S by electrolysis.
- AB-128Electrochemical detection in HPLC
In our Instructions for Use for the 656 Electrochemical Detector the user will find all the basic information about how it works and how to use it as well as how to handle the electrodes. They also contain information about the demands placed on the separating system together with the causes of and remedies for detection problems.Application Bulletin no. 128 is intended to provide an overview of the most important substance classes and mention some compounds that can easily be determined oxidatively, i.e., with detection limits in the pg range; it also mentions possible working conditions for separation and electrochemical detection and illustrates them with examples.
- AB-137Coulometric water content determination according to Karl Fischer
This Application Bulletin gives an overview of the coulometric water content determination according to Karl Fischer.Amongst others, it describes the handling of electrodes, samples, and water standards. The described procedures and parameters comply with the ASTM E1064.
- AB-141Analysis of edible fats and oils – The seven most important parameters for quality control
As the determination of the exact content of individual glycerides in fats and oils is difficult and time-consuming, several fat sum parameters or fat indices are used for the characterization and quality control of fats and oils. Fats and oils are not only essential for cooking, they are also an important ingredient in pharmaceuticals and personal care products, such as ointments and creams. Consequently, several norms and standards describe the determination of the most important quality control parameters. This Application Bulletin describes eight important analytical methods for the following fat parameters in edible oils and fats:Determination of water content in accordance with the Karl Fischer method; Oxidation stability in accordance with the Rancimat method; Iodine value; Peroxide value; Saponification value; Acid value, free fatty acids (FFA); Hydroxyl number; Traces of nickel using polarography; Special care is taken to avoid chlorinated solvents in these methods. Also, as many of the mentioned methods as possible are automated.
- AB-188pH measurement technique
This Bulletin, using practical examples, indicates how the user can achieve optimum pH measurements. As this Bulletin is intended for actual practice, the fundamentals - which can be found in numerous books and publications - are treated only briefly.
- AB-206Titer determination in potentiometry
This Bulletin provides an overview of the potentiometric titer determination of current titrants. Many publications only describe methods with color indicators. However, the titration conditions chosen for the titer determination should resemble those used for the actual analysis as closely as possible. The tables contain suitable titrimetric standard substances and electrodes for selected titrants as well as additional information. Following this, an example is given to show what an SOP for a titer determination could look like.
- AB-434Water in lithium ion battery materials – Reliable and precise determination by Karl Fischer titration
Lithium-ion batteries must be completely free of water (concentration of H2O < 20 mg/kg), because water reacts with the conducting salt, e.g., LiPF6, to form hydrofluoric acid.The water content of several materials used in lithium ion batteries can be determined reliably and precisely by coulometric Karl-Fischer titration. In this Application Bulletin the determination for the following materials is described:raw materials for the manufacture of lithium-ion batteries (e.g., solvents for electrolytes, carbon black/graphite); electrode coating preparations (slurry) for anode and cathode coating; the coated anode and cathode foils as well as in separator foil and in the combined material; electrolytes for lithium-ion batteries;
- AN-BAT-003Galvanostatic intermittent titration technique (GITT) for Li-ion batteries
This Application Note outlines GITT, a key technique for studying Li-ion battery kinetics, OCV, and diffusion, using INTELLO for streamlined control and analysis.
- AN-BAT-009Determination of the binary diffusion coefficient of a battery electrolyte
In this application note, we demonstrate how to determine the binary diffusion coefficient of a commercial liquid binary lithium ion battery electrolyte based on a galvanostatic pulse polarization method.
- AN-BAT-010Investigation of the Solid Electrolyte Interface Structure and Kinetics.
This application note presents the experimental details and an overview of the most important findings from the EIS and CV experiment to study the structure of a model solid electrolyte interface forming on a planar glassy carbon electrode in contact with a typical organic battery electrolyte.
- AN-BAT-011Determination of the Through-Plane Tortuosity of Battery Electrodes by EIS in a symmetric Lithium-iron-phosphate cell
In this application note, we demonstrate how to determine the through-plane tortuosity τ of a commercial lithium ion battery cathode material with known porosity and coating thickness, based on the electrochemical impedance spectroscopy (EIS) method.
- AN-BAT-012Determination of the Lithium Ion Transference Number of a Battery Electrolyte by VLF-EIS
In this application note, we demonstrate how to determine the lithium ion transference number of a commercial liquid binary lithium ion battery electrolyte, based on the very-low-frequency electrochemical impedance spectroscopy (VLF-EIS) method.
- AN-BAT-014Constant current constant voltage (CCCV) cycling with INTELLO
This Application Note explains how researchers can determine the underlying chemistry and potential failure mechanisms from cycle testing batteries with INTELLO.
- AN-BAT-015Differential capacity analysis (DCA) for battery research with INTELLO
This Application Note discusses differential capacity analysis (DCA) and its impact on enhancing battery performance, with a focus on using the INTELLO platform.
- AN-BAT-016EIS at different states of charge with INTELLO
This application shows how EIS, combined with INTELLO and NOVA, tracks changes in internal battery resistance across SOC levels to study performance and aging mechanisms.
- AN-C-136Metrohm intelligent Partial Loop Technique (MiPT) – a single standard calibration: 2 mL vs. 5 mL Dosing Unit
Metrohm intelligent Partial Loop Technique (MiPT) is a versatile injection mode in IC. In this application, injection volumes range from 4 to 200 µL (corresponding to 0.5 - 10 mg/L) using the 250 µL loop. Here, the use of 2 and 5 mL Dosing Units are compared.
- AN-C-148Metrohm Inline Dilution – Dilution factors of up to 10,000 in two intelligent steps
Sample dilution is a work-intensive routine task in the analysis laboratory. An automatic two-step dilution exponentiates the dilution factor – 1:100 – thus incorporating a dilution factor of 10,000. The intelligent dilution is made possible by MagIC Net, which calculates the essential dilution steps, and by the dosing properties of the 800 Dosino and the Liquid Handling Station. The Application Note shows statistical results of a 1:10,000 dilution.
- AN-COR-005Corrosion part 5 – corrosion Inhibitors
A corrosion inhibitor is a substance that reduces the corrosion rate of a metal. A corrosion inhibitor is usually added in a small concentration to the corrosive environment. This application note shows how Metrohm Autolab instruments can be used to check the quality of inhibitors.
- AN-COR-010Electrochemical Corrosion Studies of Various Metals
Corrosion of metals is a problem seriously affecting not only many industrial sectors, but also private life, resulting in enormous costs. In this application note, the results gained during electrochemical corrosion studies on different metals are compared to literature data.
- AN-COR-012ASTM G5: Potentiodynamic anodic polarization measurements
This Application Note evaluates corrosion in Type 430 stainless steel according to ASTM G5 with VIONIC powered by INTELLO and an ASTM-compliant corrosion cell setup.
- AN-COR-015Corrosion Rates Measurements in Quiescent and Turbulent Flow conditions by using Rotating Cylinder Electrode (RCE)
The rotating cylinder electrode (RCE) is successfully used in a laboratory environment to generate a turbulent flow at the surface of a sample, simulating realistic pipe flow conditions. In this application note, the corrosion rate is measured and compared between quiescent and turbulent flow conditions, while keeping all the other experimental conditions unchanged. The linear polarization (LP) technique was used together with the RCE (with and without rotation).
- AN-COR-016ASTM G61: Standard test method for conducting cyclic potentiodynamic polarization
This Application Note details ASTM G61-compliant corrosion measurements performed with VIONIC powered by INTELLO using Metrohm’s ASTM-compliant corrosion cells.
- AN-DV-001DropView solutions for treatment of electrochemical and optical results
Electrochemistry, spectroscopy, and spectroelectrochemistry (SEC) are widely used techniques in many fields. However, the data curves obtained from these analyses are quite varied, and not all electrochemical peaks and spectroscopic bands can be measured with the same procedures. This Application Note examines four tools included in the DropView 8400 and DropView SPELEC softwares to facilitate the measurement and analysis of the collected curves and data. The following measurement options are explained in detail: automeasurement, set on curve measurement, set free measurement, and set step measurement.
- AN-EC-002Reference electrodes and their usage
A reference electrode has a stable and well-defined electrochemical potential (at constant temperature), against which the applied or measured potentials in an electrochemical cell are referred. A good reference electrode is therefore stable and non-polarizable. In other words, the potential of such an electrode will remain stable in the used environment and also upon the passage of a small current. This application note lists the most used reference electrodes, together with their range of use.
- AN-EC-003Ohmic Drop Part 1 – Basic Principles
This application explains ohmic iR drop in electrochemical cells, its causes, and strategies to minimize its impact for accurate and reliable potential measurements.
- AN-EC-004Ohmic iR Drop Part 2 – Measurement: Current Interrupt and Positive Feedback
This application introduces two tools (current interrupt and positive feedback) that measure and compensate for up to 90% of the ohmic iR drop, a common error in electrochemistry.
- AN-EC-007Differences between digital scans, analog scans, and signal integration
In this Application Note, analog and digital staircase potential signals are applied to a platinum working electrode in an acidic solution. The differences in measured currents are highlighted and compared with a similar experiment where the current is being calculated from the measured charge.
- AN-EC-008Basic overview of the working principle of a potentiostat/galvanostat (PGSTAT) – electrochemical cell setup
A basic overview of the working principle of a potentiostat/galvanostat is presented. Depending on the application, the connections of the instrument to the electrochemical cell can be (or must be) set up in different ways. Below, the three commonly used electrochemical cell setups are discussed together with the role of the electrodes used in electrochemical measurements.
- AN-EC-009Spectroelectrochemical measurements
In this application note, the combination between electrochemistry and spectroscopy is shown, with the oxidation of ferrocyanide to ferricyanide monitored with IR spectra taken at defined potential steps. The increase in absorbance at 425 nm corresponding to the formation ferricyanide.
- AN-EC-011Investigation of intermediates in the electrodeposition of copper using the Autolab rotating ring disc electrode (RRDE)
Copper is arguably one of the most technologically relevant metals, especially for the semiconductor industry. The deposition process used in this industry is known as the dual-damascene process and it involves the electrodeposition of copper from an acidic cupric compound, in the presence of additives.This Application Note illustrates the use of the Autolab rotating ring disc electrode (RRDE) for the study of electrodeposition of copper and the detection of the Cu+ intermediate.
- AN-EC-012Different approaches for capacitance measurements
The relative permittivity εr, also known as dielectric constant, is of great importance in materials characterization. It can be defined as the ratio between the amount of electrical energy stored in a material and the amount of electrical energy stored in a vacuum. One of the easiest way to obtain the relative permittivity is to calculate it from capacitance values. In this Application Note, five techniques to retrieve capacity values have been compared.
- AN-EC-013The importance of using four-terminal sensing for EIS measurements on low-impedance systems
In this application note, electrochemical impedance spectroscopy (EIS) is used to test a commercial battery connected in two different ways. In the first EIS measurement, the battery is connected in a two-terminal sensing configuration. In the second EIS measurement, the battery is connected in a four-terminal sensing (Kelvin sensing) configuration. The difference in how the leads are connected results in different measured impedance values for the battery.
- AN-EC-014Oxygen Reduction Reaction with the Rotating Ring Disk Electrode
The oxygen reduction reaction (ORR) is important to the functional readiness of a fuel cell. Rotating ring disk electrode (RRDE) experiments allow the reaction to be studied in hydrodynamic conditions to determine kinetic properties via the Levich and Koutecký-Levich equations. Mechanistic information is simultaneously obtained from the reaction of intermediates at the secondary (ring) electrode. This application note describes how the RRDE from Metrohm Autolab can be used to study the ORR.
- AN-EC-019How to use a convolution method in voltammetric analysis
Convolution voltammetry consists essentially of a voltammetric, chronoamperometric, or chronocoulometric experiment followed by a mathematical transformation - convolution. Using a convolution method, the effect of the decrease of the concentration gradient can be eliminated from the total response of the electrode. This application note explains how the convolution in NOVA works.
- AN-EC-023Determination of the T-dependent conductivity of a solid proton conductor
The proton conductivity of membranes made of a proton conductive material is an essential quantity to be determined. In this application note, we present the results of an exemplary study of σDC(T) determined by impedance spectroscopy for a novel solid proton conductor in its dry state.
- AN-EC-025Study of the hydrogen region at platinum electrodes with linear scan cyclic voltammetry
The study of the electrochemical behavior of platinum in acidic media is of crucial importance in fundamental electrochemistry and electrocatalysis. Most electrocatalytic processes occurring at Pt electrodes are highly sensitive to the structure of the platinum surface. Cyclic voltammetry (CV) is a widely used rapid measurement technique that provides both a qualitative and quantitative fingerprint of platinum surfaces. A comparison of results given by linear and staircase CVs is presented in this Application Note.
- AN-EC-027Measuring the potential at the counter electrode with VIONIC powered by INTELLO
Many different configurations are made possible when using two-, three-, or four-electrode cell setups in research. Depending on the experimental requirements, one setup may be preferred over another. Therefore, the proper electrode arrangements for these three situations are defined in this Application Note. As an example, the potential at the counter electrode is measured during the platinum oxidation in acidic media, with the second sense (S2) of VIONIC powered by INTELLO. Since dissolved Pt in solution could bias the results, it is important to be able to monitor the potential of the counter electrode.
- AN-EC-030Electrochemistry of microelectrodes: a comparison with common-size electrodes
In this Application Note, the electrochemical properties of electrodes with a micrometer-size surface area are compared with the electrochemical properties of electrodes with millimeter-size surface area. The comparison is made through cyclic voltammetry in a Fe3+/Fe2+ (ferro/ferri) solution, and the differences in the voltammograms are explained with the different diffusion profiles at the electrode-electrolyte interface.
- AN-EC-031Monitoring ferrocyanide oxidation using hyphenated EC-Raman
This Application Note highlights the use of Metrohm Hyphenated EC-Raman Solutions to monitor the reversible oxidation of ferrocyanide at a gold electrode.
- AN-EC-033Utilizing hyphenated EC-Raman to study a model system
This Application Note presents a walkthrough of an experiment on 4-nitrothiophenol using hyphenated EC-Raman, a combination of Raman spectroscopy and electrochemistry.
- AN-EC-036Ohmic iR drop Part 3 – Measurement with EIS
This Application Note explains manual and automated iR drop correction with electrochemical impedance spectroscopy and cautions against using less accurate methods.
- AN-EC-040ECL detection of fentanyl
This Application Note presents an electrochemiluminescence (ECL) method for a fast, accessible, and cost-effective alternative method to detect fentanyl.
- AN-EIS-001Electrochemical impedance Spectroscopy (EIS) Part 1 – Basic Principles
Electrochemical impedance spectroscopy (EIS) is a widely used multidisciplinary technique for characterizing the behavior of complex electrochemical systems. EIS is employed in the study of a range of complex systems including batteries, catalysis, and corrosion processes. This Application Note focuses on the basic principles of EIS measurements.
- AN-EIS-002Electrochemical Impedance Spectroscopy (EIS) Part 2 – Experimental Setup
A typical electrochemical impedance spectroscopy (EIS) experimental setup consists of an electrochemical cell, a potentiostat/galvanostat, and a frequency response analyzer (FRA). This Application Note introduces common EIS experimental setups as well as details of the main experimental parameters.
- AN-EIS-004Electrochemical Impedance Spectroscopy (EIS) Part 4 – Equivalent Circuit Models
Explore how to construct simple and complex equivalent circuit models for fitting EIS data in this Application Note. Nyquist plots are shown for each example.
- AN-EIS-005Electrochemical Impedance Spectroscopy (EIS) Part 5 – Parameter Estimation
In the application note AN-EIS-004 on equivalent circuit models, an overview of the different circuit elements that are used to build an equivalent circuit model was given. After identifying a suitable model for the system under investigation, the next step in the data analysis is estimation of the model parameters. This is done by the non-linear regression of the model to the data. Most impedance systems come with a data-fitting program. In this application note, the way NOVA is uses to fit the data is shown.
- AN-EIS-006Electrochemical Impedance Spectroscopy (EIS) Part 6 – Measuring raw signals in EIS
In this application note, the advantage of recording the raw time domain data for each individual frequency during an electrochemical impedance measurement is described.
- AN-EIS-009Mott-Schottky Analysis
This Application Note presents the Mott-Schottky measurement, an extension of electrochemical impedance spectroscopy (EIS), on a popular semiconducting material.
- AN-FC-002Fuel cells part 2 – types of fuel cells
To overcome the various technical problems, many different fuel cell types have been developed. In this Application Note, proton exchange membrane, direct methanol and solid oxide fuel cells are discussed in more detail.
- AN-FC-003Fuel cells part 3 – characterization using EIS
In this Application Note the use of Electrochemical Impedance Spectroscopy (EIS) for the characterisation of PEM fuel will be demonstrated. It will be shown that EIS is a powerful diagnostic tool for the determination of the following factors that can influence the performance of a PEM fuel cell.
- AN-FC-004Impedance Measurements on Fuel Cells and Fuel Cell Stacks at High Currents: Part 1 – Autolab in combination with an electronic load
In this application note, a combination of PGSTAT and electronic load is use to perform electrochemical impedance spectroscopy in a fuel cell operating at high currents.
- AN-FET-001Characterization and performance studies of field-effect transistors (FETs) using μStat-i 400
In recent years, field-effect transistors (FETs) have become more commonly used as a sensing platform for a multitude of electrochemical and biological applications. These devices are promising bioelectronic transducers that allow both low-potential operation and stable potentiometric measurements. FETs are now seen as an attractive alternative to using conventional electrochemical detection systems in the scientific community. This Application Note gives in-depth guidance about how to operate Metrohm DropSens bipotentiostat devices for the characterization of FETs and their use as transducers. A single μStat-i 400 device, a small and portable bipotentiostat and galvanostat, is used to demonstrate the experiments.
- AN-FLU-001Fluorescence spectroelectrochemistry of [Ru(bpy)3]2+/3+ in semi-infinite diffusion regime
In this Application Note, the Metrohm DropSens SPELEC instrument is used with the FLUORESCENCE KIT for time-resolved monitoring of electrochemical reactions in a semi-infinite diffusion regime by performing fluorescence spectroelectrochemistry of the [Ru(bpy)3]2+/3+ redox couple.
- AN-H-028Standardization of 0.1 mol/L KOH in propan-2-ol
Standardization of 0.1 mol/L in propan-2-ol for use in applications for the determination of weakly acidic species in non-aqueous media.
- AN-H-042Standardization of thiosulfate titrant for copper determinations
This Application Note discusses the standardization of thiosulfate titrant for use in the determination of copper with thermometric titration.
- AN-H-044Standardization of EDTA titrant by copper
Thermometric complexometric titration of metals is often performed with tetrasodium EDTA. This Application Note explains the standardization of tetrasodium EDTA titrant with copper.
- AN-H-045Standardization of EDTA titrant by magnesium
This Application Note explains how to use magnesium to standardize tetrasodium EDTA titrant.
- AN-H-076Determination of the iodine value in fats and oils
As a key quality control parameter for fats and oils, the iodine value (IV) represents the degree of unsaturation. In this Application Note, excess Wijs reagent reacts with double bonds in the sample, and the iodine formed is quantified by thermometric back-titration with sodium thiosulfate. Thermometric endpoint titration (TET) provides a rapid, robust alternative to potentiometric methods by detecting the reaction enthalpy change without requiring sensor maintenance.
- AN-H-082Determination of surface acidity in Zeolites and other materials with a high specific surface area
This Application Note outlines the determination of total acidic active surface sites in zeolites with thermometric titration.
- AN-H-083Determination of surface basicity in zeolites and other materials with a high specific surface area
This Application Note shows that the parameter of surface basicity of zeolites can be measured by thermometric titration.
- AN-H-131Determination of titer and blank value for thermometric titrations using tiamo™
This Application Note describes in detail how to determine the blank value and the titer for thermometric titrations using tiamo™.
- AN-I-012Automated calibration of the NH3 ISE for low ammonia concentrations
Ammonia determination via NH3 ISE requires precise calibration. Details on this are provided by the present Application Note.
- AN-I-034Investigation of nucleation processes with automated titrators
This Application Note covers the formation of calcium carbonate from solution.
- AN-K-048Sample preparation with the oven technique – relative blank
Large sample sizes can lead to subtraction of too high blank values. This Application Note describes the calculation of a relative blank and thus helps to improve the accuracy of the method.
- AN-M-017IC-MS/MS analysis of trifluoroacetic acid according to DIN 38407-53
The new DIN draft standard 38407-53 outlines TFA analysis in water using direct injection LC-MS/MS, enabling quantification from 0.1–3.0 μg/L as shown in this Application Note.
- AN-NIR-012Increase the accuracy of your NIR measurements with instrument calibration
This Application Note describes how the accuracy of your NIR measurements can be increased with instrument calibration.
- AN-NIR-013Increase the accuracy of your NIR measurements with reference standards
This Application Note describes how the accuracy of your NIR measurements can be increased with reference standards.
- AN-NIR-028Data and method transfer from System II analyzer to Metrohm NIRS XDS or DS2500 analyzer
This Application Note shows the transfer of near-infrared spectroscopy analysis methods from the FOSS NIRSystems System II (5000/6500) Analyzer to the Metrohm NIRS XDS und DS2500 Analyzers. In addition, the advantages of the new NIRS XDS and DS2500 analyzers with extended spectral range and improved resolution are displayed, in particular with respect to the FOSS NIRSystems System II analyzer.
- AN-NIR-044Multiparameter Quality Control of Palm Oil with NIR Spectroscopy
Determination of key quality parameters of palm oil, namely free fatty acids (FFA), iodine value (IV), moisture content, deterioration of bleachability index (DOBI), and carotene require the use of several different analytical methods, which are laborious and can lack in accuracy. This application note demonstrates that the XDS RapidLiquid Analyzer operating in the visible and near infrared spectral region (Vis-NIR) provides a cost-efficient and fast solution for the determination of these quality control parameters in palm oil. With no sample preparation or chemicals needed, Vis-NIR spectroscopy allows for the analysis of palm oil in less than a minute and can be used by anyone.
- AN-NIR-083Quality Control of HDPE, LDPE, and PP
Identification of individual polymers with FT-IR spectroscopy can be a challenge due to sample inhomogeneity especially when larger sample sizes need to be analyzed. This application note demonstrates that the DS2500 Solid Analyzer operating in the visible and near infrared spectral region (Vis-NIR) provides a reliable and fast solution for the identification of high-density polyethylene (HDPE), low-density polyethylene (LDPE), and polypropylene (PP). With no sample preparation or chemicals needed, Vis-NIR spectroscopy allows the identification of larger inhomogeneous sample amounts in less than a minute.
- AN-NIR-111Iodine value, FFA, refractive index, and fatty acid composition in edible oils
Near-infrared spectroscopy can quickly determine multiple edible oil quality parameters simultaneously without sample preparation as shown in this Application Note.
- AN-NIR-116Determination of iodine value in frying oils with NIR spectroscopy
Monitoring the iodine value in edible oil blends is crucial to produce vegetable oils with the desired properties. This Application Note displays the benefit of using the Metrohm NIRS DS2500 Liquid Analyzer for quality control in food laboratories.
- AN-P-073Glucose and galactose in 2% lactose using amperometric detection applying Empower 3.0
This Application Note shows the determination of glucose and galactose in a 2% solution of lactose. The separation is achieved on a Hamilton RCX-30 - 250/4.6 applying pulsed amperometric detection (PAD) at a gold electrode. Instrument control, data acquisition, and data handling is done by Empower 3.0 using the Metrohm IC Driver 2.0 for Empower.
- AN-PAN-1061Inline detection of wheat flour adulteration by NIR spectroscopy
Adulteration in the food industry is a significant concern due to potential health risks and changes in product quality and nutrition. Detecting such adulteration is challenging, however, to ensure high-quality products, precise measurements during the manufacturing process are essential for identifying any contamination in raw materials and final products. This Process Application Note details the inline analysis of potato starch in the wheat flour manufacturing process with a 2060 The NIR Analyzer from Metrohm Process Analytics.
- AN-PV-003Dye-sensitized solar cells, IMVS and IMPS measurements
Dye-sensitized solar cells (DSC) are currently subject of intense research in the framework of renewable energies as a low-cost photovoltaic (PV) device. To characterize photovoltaic devices, two additional frequency domain methods can be used, based on the modulation of the light intensity. These two methods are Intensity modulated photovoltage spectroscopy (IMVS): measurement of the transfer function between the modulated light intensity and the generated AC voltage, and Intensity modulated photocurrent spectroscopy (IMPS): measurement of the transfer function between the modulated light intensity and the generated AC current.This Application Note illustrates the use of the Metrohm Autolab PGSTAT302N equipped with a FRA32M module, in combination with the Autolab Optical Bench kit to perform IMVS and IMPS characterization of photovoltaic devices.
- AN-PV-004Charge Extraction Method to Study Dye-Sensitized Solar Cells
This application note shows how it is possible with Metrohm Autolab PGSTATs and the Metrohm Autolab Optical Bench, to retrieve information about the mechanism and the kinetics of the back reaction, a side reaction which limits the performances of dye-sensitized solar cells.
- AN-PV-006Using the Autolab Spectrophotometer for Calibration of the White LED Lights
This Application Note presents the procedure to determine the responsitivity value for calibrating the white lights of the Metrohm Autolab Optical Bench.
- AN-RA-002The carbon battle characterization of screen-printed carbon electrodes with SPELEC RAMAN
Carbon materials are a remarkable choice as electrode surfaces. They are not only cost-effective and chemically inert, but also have a low background current and a wide potential window. Physical and chemical properties of new carbon nanomaterials depend mainly on their structure, so their characterization is essential to choose the right material for different applications.Raman spectroscopy is a very attractive technique for this purpose, effortlessly distinguishing information about the bond structure of carbon materials, and, therefore, about their possible properties. DropSens screen-printed electrodes (SPEs) are low-cost, disposable devices, available with working electrodes fabricated in several carbon materials. This Application Note describes how their properties can be studied by Raman spectroscopy.
- AN-RA-003In situ, fast and sensitive: Electrochemical SERS with screen-printed electrodes
Substrates for surface-enhanced Raman spectroscopy (SERS) are typically fabricated with complex (micro/nano)structures of noble metals, enabling trace level detection of analytes. Due to the high costs and reactivity of these SERS substrates, they often have a limited shelf life. Development of new substrate materials which minimize these issues yet maintain the same performance standards is a constant concern.Screen-printed electrodes can be easily fabricated using different metallic materials with the well-established screen-printing method, leading to mass production of versatile, cost-effective, and disposable devices. In this Application Note, the feasibility of using readily-available screen-printed metal electrodes as suitable substrates for the fast and sensitive detection of different chemical species by in situ electrochemical SERS (EC-SERS) is shown.
- AN-RA-004UV/VIS spectroelectrochemical monitoring of 4-nitrophenol degradation
Spectroelectrochemistry is a multi-response technique that provides both electrochemical and spectroscopic information about a chemical system in a single experiment, i.e., it offers information from two different points of view. Spectroelectrochemistry focused on the UV/VIS region is one of the most important combinations because this allows us to obtain not only valuable qualitative information, but also outstanding quantitative results. In this application note, the degradation kinetics for 4-nitrophenol, a known pollutant, were determined using SPELEC.
- AN-RA-005Characterization of single-walled carbon nanotubes by Raman spectroelectrochemistry
Spectroelectrochemistry is a multi-response technique that provides electrochemical and spectroscopic information about a chemical system in a single experiment, i.e., it offers information from two different points of view. Raman spectroelectrochemistry could be considered as one of the best techniques for both the characterization and behavioral understanding of carbon nanotube films, as it has traditionally been used to obtain information about their oxidation-reduction processes as well as the vibrational structure. This application note describes how the SPELEC RAMAN is used to characterize single-walled carbon nanotubes by studying their electrochemical doping in aqueous solution as well as to evaluate their defect density.
- AN-RA-006New strategies for obtaining the SERS effect in organic solvents
Many electrochemical methods have been developed but are traditionally limited to aqueous media. Raman spectroelectrochemistry in organic solutions is an interesting alternative, but developing new EC-SERS procedures is still required. This Application Note demonstrates that the electrochemical activation of gold and silver electrodes enables the detection of dyes and pesticides in organic media.
- AN-RA-008Easy detection of enzymes with the electrochemical-SERS effect
Low sensitivity has limited the use of Raman spectroscopy as a detection method. However, the surface-enhanced Raman scattering (SERS) effect has improved its effectivity for analytical use. Aldehyde dehydrogenase (ALDH) and cytochrome c are analyzed by Raman spectroelectrochemistry as a proof of concept in this Application Note.
- AN-RA-009Comparison of SPELEC RAMAN and standard Raman microscopes
This Application Note compares SPELEC RAMAN and a standard Raman instrument by analyzing their performance in measuring single-walled carbon nanotubes (SWCNT).
- AN-RS-001Identifying polymers with Raman spectroscopy
This application highlights Metrohm’s XTR® technology to identify colored polymers by extracting the Raman signal from spectra with strong background fluorescence.
- AN-RS-006Differentiation between isopropyl alcohol from various manufacturers
This Application Note shows the rapid, non-destructive identification of isopropyl alcohol from two manufacturers using Raman spectroscopy following the creation of a suitable library. The measurements with the hand-held Raman spectrometer Mira M-1 require no sample preparation and provide immediate results that identify the samples unambiguously.
- AN-RS-008Identification of monomers with Raman spectroscopy
Raman spectroscopy can easily monitor polymerization by tracking monomer consumption and polymer formation, providing a valuable tool for polymer manufacturers.
- AN-RS-013Determination of Container Contents
Identification of unknown materials in the field can be a complicated affair, especially in critical situations, where speed, safety, and ease-of-operation are essential. Mira DS, Metrohm Raman’s handheld Raman analyzer, and the intelligent Universal Attachment (iUA) give the user automated Content ID capabilities. Content ID achieves through container identification of unknown materials quickly, easily, and safely.
- AN-RS-034Orbital Raster Scan (ORS™)
This application note presents the Orbital Raster Scan (ORS) technology from Metrohm Raman to overcome low resolution, poor sensitivity, and sample degradation while still interrogating a large sample area.
- AN-RS-041Discriminating counterfeit beer with Raman spectroscopy and PCA
Currently, there are no simple tests to identify counterfeit beer. This Application Note demonstrates the ability of i-Raman EX, the B&W Tek Laboratory Raman instrument with a 1064 nm laser, with principal component analysis (PCA) to distinguish between beers from different brewers and from a mixture of beers.
- AN-RS-045Transition RMID Operations Between Handheld Raman Devices
This application shows how to seamlessly transition from Metrohm’s NanoRam 785 to the newer MIRA P system, ensuring continuity in raw material identification (RMID).
- AN-RS-048Phosphates speciation with Raman spectroscopy
Metrohm’s MIRA XTR handheld Raman spectrometer enables fast, reagent-free identification of phosphate species, enabling continuous monitoring of dynamic systems.
- AN-RS-049Determining phosphate concentration with Raman spectroscopy
Raman spectroscopy with PLS modeling enables rapid, accurate, nondestructive quantification of the total phosphate content in solution with minimal sample preparation.
- AN-RS-055Low-frequency Raman spectroscopy
Low frequency Raman spectroscopy extends conventional Raman analysis by capturing vibrational modes down to 65 cm-1, enabling deeper insights into molecular structure, protein characterization, polymorph identification, and phase changes.
- AN-RS-056Quantification of methanol in contaminated spirits
Raman spectroscopy is ideally suited to rapidly screen for methanol contamination in spirits.
- AN-S-33915 organic acids on the Metrosep A Supp 7 - 250/4.0 using a high-pressure gradient
High-pressure gradients combine the advantages of weak and concentrated eluents. Weak eluents promote the separation of the components that elute early and in close proximity to one another; in contrast to this, concentrated eluents accelerate the analysis of the components that are stronger retained at the column. The high-pressure gradient used in this application makes it possible to separate 15 organic acid anions in a single run. The blank subtraction option in the MagIC Net software simplifies the allocation of the peaks and with it the quantification.
- AN-S-363Combination of Inline Dilution with subsequent Inline Ultrafiltration and automatic calibration
Metrohm Inline Sample Preparation (MISP) is a collection of versatile, time- and cost- effective techniques reducing manual sample preparation. This Application Note describes the combination of Inline Dilution with Inline Ultrafiltration. Samples are automatically diluted and subsequently filtered before injection. MagIC Net allows to run intelligent dilution by checking results and rediluting the sample if the result is out of the calibration range. Also the multipoint calibration is performed by automatically diluting the stock standard solution. In this way, an automatic calibration of each analyte is effectively achieved.
- AN-S-383Metrohm IC Driver for OpenLab CDS: Anions with Dose-in Gradient and Dosino Regeneration
OpenLab CDS is the newest generation of chromatography data systems from Agilent. The Metrohm IC Driver 1.0 for OpenLab CDS implements Metrohm ion chromatographs in OpenLab CDS for full control and data acquisition. This application shows the use of a gradient (Dose-in Gradient) as well as Dosino Regeneration in OpenLab CDS. Fluoride, chloride, nitrite, bromide, nitrate, sulfate, phosphate, and iodide in a standard solution are separated and determined.
- AN-S-384Metrohm IC Driver for OpenLab CDS: Iodide measurement with amperometric detection
OpenLab CDS is the newest generation of the Agilent chromatography data systems platform. The Metrohm IC Driver 1.0 for OpenLab CDS enables introducing Metrohm IC instruments to this platform for full control and data acquisition. This application shows the analysis of iodide by amperometric detection, enabling detection at trace levels. The eluent is produced automatically by the 941 Eluent Production Module. In this way, amperometric detection can be executed with the same functionality and performance as with MagIC Net.
- AN-SEC-001Spectroelectrochemistry: an autovalidated analytical technique
Spectroelectrochemical experiments not only provide outstanding qualitative information about samples, but also offer other quantitative data that can be considered when performing analyses. A single set of experiments allows analysts to obtain two calibration curves: one with the electrochemical data and another with the spectroscopic information. The concentration of tested samples is calculated by using both curves, confirming the obtained results by two different routes. In this Application Note, comparison between electrochemical and spectroscopic determinations demonstrates that the two methods measure uric acid (UA) indistinctively, with close agreement of the calculated values with empirical data.
- AN-SEC-002Gathering information from spectroelectrochemical experiments
In-situ spectroelectrochemistry provides dynamic electrochemical and spectroscopic information concurrently with the redox reaction occurring on the electrode surface. Although different spectroelectrochemical configurations can be used, simple equations explain how to relate electrochemistry and spectroscopy for each experimental setup. This Application Note describes how the quantification of one electrochemical parameter (the diffusion coefficient) is calculated from the spectroscopic data as a proof of this concept.
- AN-SEC-004Spectroelectrochemical analysis of electrochromic materials
Poly(3,4-ethylenedioxythiophene) (PEDOT) is one of the most promising ICPs due to its high conductivity, electrochemical stability, catalytic properties, high insolubility in almost all common solvents and interesting electrochromic properties (transparent in the doped state and colored in the neutral state). In this Application Note, PEDOT film is evaluated by spectroelectrochemical techniques.
- AN-T-104Fully automated determination of barium in aqueous solution
This Application Note describes the fully automated complexometric determination of barium in aqueous solutions with a copper ion-selective electrode.
- AN-T-105Fully automated determination of bismuth(III) in aqueous solution
This application note shows how to determine the bismuth content automatically in aqueous solution with potentiometric titration.
- AN-T-109Iodine value in canola and olive oil
This Application Note presents a modified time-saving method to determine iodine value (IV) in edible oils based on several standards (EN ISO 3961, ASTM D5554, etc.).
- AN-T-110Peroxide value in edible oils
This Application Note details a method to determine the peroxide value of edible fats and oils based on EN ISO 27107, EN ISO 3960, AOAC 965.33, Ph.Eur. 2.5.5, and USP<401>.
- AN-T-112Acid value and free fatty acids in edible oils
This Application Note describes the titration of acid value and free fatty acids in different edible oils, based on the standards EN ISO 660, USP<401>, and Ph.Eur. 2.5.1.
- AN-T-125Automatic determination of cadmium in aqueous solution with the Cu ISE
This application note describes the analysis of cadmium in aqueous solution using a copper ion-selective electrode with Cu-EDTA complex used as an indicator.
- AN-T-126Automatic determination of cobalt in aqueous solution with the Cu ISE
This application note describes the fast, accurate determination of cobalt with a copper ion-selective electrode (Cu ISE) and Cu-EDTA complex as an indicator.
- AN-T-127Automatic determination of copper in aqueous solution with the Cu ISE
This Application Note describes the automated complexometric determination of copper with the Cu ISE.
- AN-T-144Mercury analysis using automatic photometric titration
Mercury can be determined in alkali media using back titration with zinc sulfate. Eriochrome black T is used as the indicator for this procedure. The Optrode is used for indication at a wavelength of 502 nm.
- AN-T-221SET titration of HPLC mobile phases
This Application Note shows the automatic pH adjustment of a mixture of acetonitrile, water and amine using a Metrohm titrator.
- AN-T-230Quantification of 1,2-diols by iodometric redox titration
Mannitol content determination is an important aspect of quality control in the pharmaceutical and food industries. Selective oxidative cleavage can be used to quantify the amount of 1,2-diol groups in the analyte. Determining the 1,2-diol content by iodometric titration can be fully automated for the most accurate results using an automated titrator and the dPt Titrode from Metrohm.
- AN-T-244Standardization of sodium thiosulfate
The OMNIS Titrator equipped with a Pt Titrode accurately and reliably determines titer concentration even in diluted titrants as shown in this Application Note.
- BWT-4905The NanoRam Hand-held Raman Spectrometer Full Regulatory Compliance for the Inspection of Raw Materials and Chemicals Used in the Pharmaceutical Industry.
The NanoRam is a state-of-the-art, handheld Raman spectrometer for the rapid identification of chemicals used in the pharmaceutical manufacturing process. It has been specifically designed for these applications and is fully compliant with all the major global regulatory, safety, and commercial testing agencies applicable to the pharmaceutical industry.
- BWT-4907Fundamentals of Raman Spectroscopy
The fundamentals of Raman instrumentation and spectroscopy are presented along with common applications of Raman.
- BWT-4909The Use of Raman Spectroscopy in the Field of Cancer Diagnostics
Raman spectroscopy and surface enhanced Raman spectroscopy (SERS) are proving to be invaluable tools in the field of biomedical research and clinical diagnostics. Raman systems are also being developed for molecular diagnostic testing to detect and measure human cancer biomarkers. This review highlights two applications realting to breast cancer and pancreatic cancer diagnosis together with examples of the use of Raman spectrometry in biomedical research areas such as the identification of bacterial infections, showing that Raman is an important part of the medical toolbox, as we continually strive to improve diagnostic techniques and bring a better health care system to patients.
- BWT-4911Using Handheld Raman to Reduce Risks in Materials Used for Manufacturing
Raman spectroscopy is a valuable tool to provide rapid, specific analysis for identification of raw materials, thus reducing the risk of using substandard or incorrect materials in manufacturing. The utility of handheld Raman increases productivity, and the ability to do full testing without creating bottlenecks in the production process. The integration of the Raman data into a company’s data management system provides a secure means of handling data and results, with reduced risk of transcription errors, and data loss.
- WP-046Overcoming the aqueous limitation at NIR Spectroelectrochemistry
NIR spectroscopy has been traditionally limited due to the water absorption in this spectral range. In this way, the well-known water restriction has limited the development of new applications for NIR spectroelectrochemistry. In this work, several interesting alternatives are proposed in order to minimize or even to remove the aqueous contribution in this spectral range.
- WP-055Corrosion Best Practice – Creating Pipe-flow Conditions Using a Rotating Cylinder Electrode
Electrochemical measurements utilizing a rotating cylinder electrode (RCE) are widely used in industrial corrosion applications when simulation of realistic pipe conditions are necessary in a lab environment. This white paper allows further insight into the particularities and parameters which govern the electrochemical measurements, in particular measurements performed in turbulent flow conditions, and shows a complete picture of the best practice use of this technique. The annexes provide an overview and short explanation of the parameters and laws specific to the fluid behavior in electrochemical cells with RCE.
- WP-058Virus detection: Fast, sensitive, and cost-effective with electrochemical testing
With significant global viral outbreaks becoming the norm rather than generational outliers, it is imperative that fast, sensitive, and cost-effective testing is available to the masses. Screen-printed electrodes (SPEs) allow rapid, widespread testing of populations for infectious disease, without the need of skilled personnel or burdensome equipment in the field. The possibility of point-of-care (POC) testing with SPEs has been exhibited in several recent studies. Metrohm DropSens combines high production capabilites of custom-made SPEs with a valid ISO 13485 certification "Manufacturing of sensors for medical devices", meaning testing procedures developed on these SPEs can be reliably scaled up for larger operations, with easier regulatory approval for commercialization.
- WP-073On-site detection of hexavalent chromium in protective paint primers
It is widely accepted that prolonged exposure to hexavalent chromium compounds can have dire health effects. This has led to increased regulation of chromium-containing products and greater demand for technologies that can positively identify hexavalent chromium in potential matrices. These include paints, dyes, and primers, which can pose a problem for interrogation with Raman, as strongly colored materials often exhibit fluorescence when stimulated at 785 nm. Fluorescence can obscure the Raman signal and prevent positive identification. MIRA XTR DS provides all the functionality of handheld material ID with a new capability that selectively eXTRacts the Raman signal from fluorescent materials. Fluorescence rejection at 785 nm provides higher sensitivity and resolution than 1064 nm systems, as well as a much wider scope of applications amenable to Raman spectroscopy. MIRA XTR DS offers a comprehensive and versatile material ID test solution for field operations.
- WP-080Seamless electrochemical measurements with VIONIC powered by INTELLO
This White Paper introduces seamless measurements that are possible with VIONIC powered by INTELLO and applications that can benefit from this unique feature. The combination of software and new generation electronics provides data in real-time with no gaps or missed reactions.
- WP-086Measuring organic acids and inorganic anions with ion chromatography mass spectrometry
This White Paper focuses on selected IC-MS applications for the straightforward identification and quantification of organic acids and inorganic anions in different matrices.
- WP-097Why switch to OMNIS Client/Server (C/S)?
OMNIS Client/Server boosts business performance with scalable server management, cutting costs by reducing hardware, energy use, and maintenance across locations.
- AN-U-076Zinc Oxide Assay as per USP General Chapter <591>
Manufacturers and laboratories must use validated methods to determine the zinc content in skin care products and pharmaceutical supplements to meet strict quality standards set by the United States Pharmacopeia and National Formulary (USP-NF). USP-NF has updated the zinc monograph (General Chapter <591>, Zinc Determination) and replaced the existing identification procedure of titration with ion chromatography (IC). The analysis involves separating Zn using a Metrosep A Supp 10 column followed by post-column reaction using 4-(2-pyridylazo)resorcinol and detection at 530 nm.