Metrosep Carb 2 - 100/4.0
6.1090.410
Metrosep Carb 2 - 100/4.0
en
6.1090.410
Feature overview
The Metrosep Carb 2 - 100/4.0 IC column is particularly suitable for the determination of carbohydrates using alkaline eluents and pulsed amperometric detection. The high-capacity anion exchanger column is based on a styrene-divinylbenzene copolymer. It is stable in the range of pH = 0 - 14 and provides separation of glucose, fructose, and sucrose. It is also suitable for the analysis of some sugar alcohols and oligosaccharides. Short analysis times can be achieved on the 100 mm version of the Metrosep Carb 2 separation column.
Tech specs
| Housing material | PEEK |
|---|---|
| Carrier material | Polystyrene-divinylbenzene copolymer with quaternary ammonium groups |
| Particle size | 5.0 µm |
| Standard flow | 0.8 mL/min |
| Maximum pressure | 20 MPa |
| Maximum flow | 1.6 mL/min |
| pH range | 0–14 |
| Column dimensions | 100 x 4.0 mm |
| Temperature range | 20–60 °C |
| Standard temperature | 30°C |
Chromatogram
-
- Threaded stopper
- 6.2744.060
- For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.
- <p>For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.</p>
- PCS
- 2
-
- Threaded stopper
- 6.2744.060
- For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.
- <p>For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.</p>
- PCS
- 2
-
- Metrosep BO3 Trap 1 - 100/4.0
- 6.1015.200
- Trap column for the removal of borate contaminants from the eluent. The Metrosep BO3 Trap 1 - 100/4.0 is used mainly in carbohydrate analysis with hydroxide eluents.
- <p>Trap column for the removal of borate contaminants from the eluent. The Metrosep BO<sub>3</sub> Trap 1 - 100/4.0 is used mainly in carbohydrate analysis with hydroxide eluents.</p>
- PCS
- 1
- Metrosep CO3 Trap 1 - 100/4.0
- 6.1015.300
- Trap column for the removal of carbonate traces in hydroxide eluents.
- <p>Trap column for the removal of carbonate traces in hydroxide eluents.</p>
- PCS
- 1
- Metrosep Carb 2 Guard/4.0
- 6.1090.500
- The Metrosep Carb 2 Guard/4.0 effectively removes contamination, thus protecting the analytical separation column. The design of the guard column has been selected in such a way that its influence on the chromatographic separation can be ignored.
- <p>The Metrosep Carb 2 Guard/4.0 effectively removes contamination, thus protecting the analytical separation column. The design of the guard column has been selected in such a way that its influence on the chromatographic separation can be ignored.</p>
- PCS
- 1
- Metrosep Carb 2 S-Guard/4.0
- 6.1090.510
- The Metrosep Carb 2 S-Guard/4.0 effectively removes contaminations, thus protecting the analytical separation column. The design of the guard column has been selected in such a way that its influence on the chromatographic separation can be ignored.
- <p>The Metrosep Carb 2 S-Guard/4.0 effectively removes contaminations, thus protecting the analytical separation column. The design of the guard column has been selected in such a way that its influence on the chromatographic separation can be ignored.</p>
- PCS
- 1