Applikationen
- AN-I-014Bromide in water
Bromide is ubiquitous in sea water, where it is present in concentrations of around 65 mg/L. By contrast, the maximum bromide concentration in drinking and ground water is usually less than 0.5 mg/L. A higher bromide content may indicate a contamination of the water caused by fertilizer, road salt or industrial waste water. This Application Note describes the determination of the bromide content in water via direct measurement with a Br ion-selective electrode in accordance with ASTM D1246.
- AN-I-030Dissolved oxygen in tap water
In municipal water supplies, higher dissolved oxygen (DO) content is desirable because it improves the taste of drinking water. However, high DO levels also speed up corrosion in water pipes. For this reason, industries utilize water with as little DO as possible, and add scavengers such as sodium sulfite to remove any oxygen from a water supply. Municipal water supply pipes are normally coated inside with polyphosphates to protect the metal from contact with oxygen, thus allowing higher DO contents. Therefore, monitoring the DO content online in a water supply is important to assess its DO content to either improve taste or minimize pipe corrosion. Using an optical sensor, such as the O2-Lumitrode, allows a fast and reliable determination according to ISO 17289.
- AN-I-028Dissolved oxygen in surface water
Oxygen diffuses into water sources from the air via aeration, however several factors can reduce the dissolved oxygen (DO) content in water. First, as water warms up, oxygen is released into the atmosphere. Secondly, oxygen is consumed by bacteria and other microorganisms which feed on organic material. Finally, plants can also consume oxygen in certain situations.Human-induced alterations can have a negative influence on surface water when DO values fall below crucial limits for maintaining the life supporting capacity of freshwater ecosystems. Therefore, monitoring the DO content in surface water by an optical sensor to assess its quality is important.
- AN-I-013Sulfide in ground and waste water
Even in low concentration, sulfide ions cause odor and corrosion problems in ground water and waste water. They can release hydrogen sulfide in acidified water, which is toxic in even minuscule amounts. This Application Note describes the determination of sulfide concentration in water via direct measurement with the Ag/S-ISE in accordance with ASTM D4658.
- AN-I-009Cyanide in water
Cyanides are used in some industrial processes, but if not handled carefully, they could contaminate the wastewater. In an acidic or neutral environment, this contaminated wastewater can form highly toxic hydrogen cyanide gas. Furthermore, the cyanide salts could also poison the environment and enter the ground water system. Therefore, it is essential to monitor the content of cyanide in effluent water. Cyanides can be easily determined with a cyanide ion-selective electrode. This application note presents a method for cyanide analysis according to APHA Method 4500-CN and ASTM D2036.
- AN-PAN-1040Ammonia in cooling water of thermal power plants
Thermal power plants require enormous amounts of water, using high purity steam at high pressure to rotate turbines. A separate cooling water circuit is implemented, which helps to form a vacuum when the steam condenses after the turbines. Maintaining this vacuum with optimal condensation parameters is critical for the power plant efficiency. The copper condensers are susceptible to corrosion by ammonia, leading to an upper limit of 2 mg/L NH3 set by EPRI in cooling water. Small cracks in the condenser combined with the large pressure differential between the steam circuit and the cooling water circuit will contaminate the high purity water in the boiler, causing major problems and necessitating a shutdown for plant maintenance. Monitoring NH3 online in cooling water with a process analyzer can signal early problems in a plant before significant intermediation is necessary.
- AN-PAN-1045Online monitoring of copper corrosion inhibitors in cooling water
Copper is used widely in industrial cooling water systems for its heat transfer properties, although it is susceptible to corrosion. Corrosion can cause a loss of efficiency and eventually a failure of equipment, leading to costly maintenance, replacement, and downtime. Corrosion inhibitors (triazoles) can be added to the water chemistry, which form sparingly soluble protective layers on the surface of the metal. Triazole concentrations must be maintained to protect the copper, which necessitates regular concentration determinations in cooling water. The 2060 IC Process Analyzer with UV/VIS detection is well-suited for this application, able to precisely and reliably measure multiple ionic and UV-active compounds simultaneously in cooling water.
- AN-S-236Drinking water quality by EPA 300.1
Fast and reliable analysis of drinking water by combining EPA method 300.1 Parts A and B in a single IC run.
- AN-PAN-1001Online analysis of hydrogen sulfide and ammonia in sour water stripper
This Process Application Note details the simultaneous online analysis of H2S and NH3 in sour water which was previously treated in the sour water stripper (SWS). The method includes automatic cleaning and calibration. Fast and accurate results are continuously supplied for process control.
- AN-S-261Chlorid, Nitrat und Sulfat in "produced water"
Bestimmung von Chlorid, Nitrat und Sulfat in "produced water" mittels Anionenchromatographie und anschliessender Leitfähigkeitsdetektion nach chemischer Suppression.
- AN-M-001Aliphatische Monocarbonsäuren in «produced water» mittels IC/MS-Kopplung
Bestimmung von Essig-, Propion-, Butter-, Valerian- und Capronsäure in «produced water» mittels Anionenchromatographie und anschliessender Leitfähigkeits- und MS-Detektion nach Nachsäulenaddition von Ammoniak für die MS-Detektion und Inline-Probenvorbereitung durch Dialyse.
- AN-C-060Magnesium, Strontium und Barium in "produced water" (11 g/L Natrium)
Bestimmung von Magnesium, Strontium und Barium in "produced water" mittels Kationenchromatographie und anschliessender direkter Leitfähigkeitsdetektion.
- AN-PAN-1044Online trace analysis of amines in the alkaline water-steam circuit of power plants
Neutralizing amines are added to adjust pH levels within the water-steam circuit of power plants to avoid corrosion-inducing conditions. This preventive maintenance can reduce costly and critical downtimes due to corrosion, however frequent monitoring of the amine chemistry is necessary to ensure conditions stay optimal. The 2060 IC Process Analyzer featuring the Metrohm intelligent Partial Loop Technique (MiPT) option is ideal for this application, with the ability to measure trace amounts of the analytes precisely and reliably through an automated method. The benefit of using IC is that multiple analytes can be monitored simultaneously, and here the ability to measure the presence of sodium next to the high ammonium or amine concentrations could indicate that cooling water is seeping into the circuit, indicating a problem upstream.
- AN-M-003Phosphat in «produced water» mittels IC/MS-Kopplung nach Probenvorbereitung durch Inline-Dialyse
Bestimmung von Phosphat in «produced water», welches bis zu 100 g/L Chlorid sowie Rohöl enthält, mittels Anionenchromatgraphie und anschliessender Leitfähigkeits- und MS-Detektion nach Inline-Dialyse.
- 8.000.6112Technical Poster: Haloacetic acids in water
LC-MS/MS quantification methods are commonly used to determine trace levels of organic compounds. However, highly polar reversed phases (RPs) lack sufficient retention for very polar compounds, or they fail for charged organics. Separation using ion chromatography (IC) and subsequent MS/MS detection is an innovative alternative approach that combines the fast elution and flexibility of the IC system with the excellent resolution and high sensitivity of the MS/MS detector. This poster presents a fast, robust and reliable IC-MS/MS method for the detection of HAAs and other ionic analytes using the high-end MS/MS system QTRAP 6500+ from SCIEX coupled to a the 940 Professional IC Vario One SeS/PP/HPG instrument. This analytical setup is able to identify and quantify the presence of HAAs at trace levels with LLODs between 0.02 μg/mL and 0.2 μg/L on a single HAA. This capability easily fulfills the sensitivity requirements specified in EU Drinking Water Directive, which specifies a maximum residue level (MRL) of 60 mg/mL for the sum of monochloroacetic acid, dichloroacetic acid, trichloroacetic acid, monobromoacetic acid and dibromoacetic acid present in the representative sample.
- AN-RS-018Trace Detection of Malachite Green in Stream Water
Malachite green (MG) is a textile dye with effective fungicidal properties, however it is acutely toxic and its metabolites persist in the flesh of fish and mammals, making it a threat to the human food chain. The EU has concluded that contaminated foods containing levels higher than 2 μg/g MG constitute a credible health risk, and several countries have banned malachite green as an aquaculture additive. Despite tight regulation, seafood products contaminated with MG continue to find their way to consumers.Using Misa (Metrohm Instant SERS Analyzer) to ensure food safety, the rapid and highly sensitive detection of malachite green is achieved in a facile assay format.
- 8.000.6013Analyse von „Produced Water“-Verschmutzungen durch Ionenchromatographie
Die Herausforderung bei der Analyse, die hier im Einzelnen vorgestellt wird, besteht in der Detektion von Sub-ppb-Mengen an Bromid, Sulfat, aliphatischen Monocarbonsäuren und verschiedenen Erdalkalimetallen in Anwesenheit einer sehr hoher Konzentration von Natrium und Chlorid. Bromid, Sulfat, Acetat und Butyrat können mittels suppressierter Leitfähigkeitsdetektion zuverlässig nachgewiesen werden. Aufgrund von Matrixeffekten kann Propionat nur qualitativ bestimmt werden. Dieser Nachteil kann beseitigt werden, indem ein ionenchromatographischer Detektor (IC) mit einem massenspektrometrischen (MS) Detektor gekoppelt wird. Dadurch treten weniger Matrixstörungen, aber signifikant bessere Empfindlichkeiten auf. Die Kationen von Magnesium, Barium und Strontium werden durch nicht suppressive Leitfähigkeitsdetektion ermittelt.
- AN-I-031Dissolved oxygen in acrylic dispersion paint
Acrylic dispersion paints are made of pigment suspended in acrylic polymer emulsions, which also include other organic material such as plasticizers, defoamers, or stabilizers. Acrylic dispersion paints are water-soluble but become resistant to water when dry. Due to the fact that once dry, acrylic dispersion paints can no longer be used, they should be stored air-tight at room temperature. For research purposes, it is of interest to assess the dissolved oxygen (DO) concentration in such samples as it is assumed that the DO amount can be related to the storage life. This Application Note describes a fast and accurate determination of dissolved oxygen by using an optical sensor.
- AN-PAN-1043Online trace analysis of cations in the primary circuit of nuclear power plants
In power plants, corrosion is the primary factor leading to costly and critical downtimes. In a nuclear power plant, a separate water circuit known as the Pressurized Water Reactor (PWR) ensures radioactive material stays contained while still transferring heat and energy to the other circuits. Boric acid and lithium hydroxide are added specially to the PWR circuit in amounts which can complicate other analytical measurements. Lithium prevents corrosion and must be monitored, along with other cations such as zinc, nickel, and ammonium. In order to measure these cations online at sub-µg/L range in a single analysis, the 2060 IC Process Analyzer is offered with combined Inline Preconcentration and Inline Matrix Elimination. Several cations can be analyzed in a single injection, with automated sample preparation making precise and reliable measurements easier.
- AN-T-073Vollautomatische Bestimmung der Leitfähigkeit, des pH-Wertes und der Alkalinität in Leitungswasser nach Probenvorbereitung
Das automatisierte system Basic water analysis bestimmt Leitfähigkeit, pH-Wert und Alkalinität in sämtlichen Wasserproben. Der hohe Automatisierungsgrad (z. B. automatische Probenzugabe, automatische Kalibrierung sowie die automatische Bestimmung des Titers und der Zellkonstante) minimiert Fehler und gewährleistet eine ausgezeichnete Reproduzierbarkeit.
- AN-RS-005Differentiation of inorganic salts using Raman spectroscopy
This Application Note documents the suitability of hand-held Raman spectrometers, e.g., the Mira M-1, for the identification and differentiation of salts such as carbonates, phosphates, and sulfates. The focus of the work was the rating of the influence of the cationic part and of the crystal water on the Raman spectroscopy identification of the salts.
- AN-I-023Fluoride in tea
One of the major sources of fluoride intake for humans comes from foodstuff, such as tea. Tea actually has one of the highest potentials to increase the daily fluoride intake. Excessive fluoride intake may lead to dental or skeletal fluorosis. The World Health Organization does not recommend consuming water with a fluoride content higher than 1.5 mg/L. In the presented method according to DIN 10807, the fluoride content can be assessed quickly with an ion selective electrode.
- AN-NIR-079Moisture analysis in fertilizer products
Moisture content is one of the most commonly measured properties of fertilizers. Globally, regulations for different fertilizers vary, but local legal limits ensure that the maximum amount of water must not be exceeded. Next to gravimetric methods, Karl Fischer titration is often used for accurate moisture determination.Compared to these methods, near-infrared spectroscopy (NIRS) offers unique advantages: it generates reliable results within seconds, and at the same time does not create chemical waste. This Application Note explains how NIRS can offer fast, reagent-free analysis of moisture content in various fertilizer products.
- AN-NIR-076Quality control of polyvinyl alcohol
Polyvinyl alcohol (PVA) is a linear polymer, used in a variety of medical products (e.g. eye drops). Here, the degree of alcoholysis is an important index for the water solubility, viscosity, and adhesion of the product. The degree of alcoholysis is defined as the percentage of hydroxyl functional groups compared to the total functional groups accessible in the molecule. Conventional alcoholysis determination can take up to six hours per sample. Compared to the primary method, analysis with near-infrared spectroscopy (NIRS) only takes one minute. The following application note describes the determination of the degree of alcoholysis by NIRS.
- AN-NIR-092Quality Control of PVC foils
PVC (polyvinyl chloride) foils with a PVDC (polyvinylidene chloride) coating are often used for high performance packaging films like pharmaceutical blister packs or in food packaging. In multi-layer blister films, the PVC serves as the thermoformable backbone structure, whereas the PVDC coating acts as a barrier against moisture and oxygen. The Water Vapor Transmission Rate (WVTR) and Oxygen Transmission Rate (OTR) are influenced by the composition and the thickness of the coating. A fast way to monitor PVDC coating thickness is with near-infrared spectroscopy. Results are provided in a few seconds, indicating when adjustments in the polymer production process are necessary.
- AN-H-026Bestimmung von Ätzmittel, Carbonat und Aluminiumoxid in Bayer-Prozesslauge
Dieses Application Note beschreibt eine Methode zur Bestimmung von Ätzmittel, Carbonat und Aluminiumoxid in gebrauchten Bayer-Prozesslaugen. Die Methode beruht auf Verfahren, die von Watts-Utley und VanDalen-Ward entwickelt wurden.
- AB-313Analyse von Bayer-Prozesslaugen mittels thermometrischer Titration
Die Bestimmung des Gesamtgehalts an Ätzmittel, Natriumcarbonat und Aluminiumoxid in (Bayer-)Prozesslaugen kann mit hoher Präzision und Geschwindigkeit mit Hilfe des 859 Titrotherm in einer thermometrischen Säure-Base-Titration erfolgen. Eine vollständige Titration dauert ca. 5 Minuten.Der Ablauf ist eine automatisierte Adaptation der traditionellen Watts-Utley-Methode und ähnlich der thermometrischen VanDalen-Ward-Titrationsmethode, allerdings mit dem zusätzlichen Vorteil, dass die Analyse auch für den Carbonatgehalt der Lauge durchgeführt werden kann.
- AN-V-215Zink in Trinkwasser mit der scTRACE Gold
Zink ist ein essentielles Spurenelement für den Menschen. Eine übermäßige Aufnahme von Zink in höheren Konzentrationen kann jedoch schädlich sein. In den „Guidelines for Drinking-water Quality“ der Weltgesundheitsorganisation gibt es keinen Richtwert für Zink, da typische Gehalte im Trinkwasser keine Rolle spielen. Die anodische Stripping-Voltammetrie ist eine praktikable, weniger anspruchsvolle Alternative zur Atomabsorptionsspektroskopie (AAS) zur Bestimmung von Zink in Trinkwasser. Während AAS (und konkurrierende Methoden) nur in einem Labor durchgeführt werden können, können anodische Stripping-Voltammetrie-Bestimmungen konventionell im Labor oder alternativ vor Ort mit dem tragbaren VA-Analysator 946 durchgeführt werden. Die Bestimmung erfolgt an der scTRACE Gold-Elektrode.
- AN-PAN-1042Online trace analysis of anions in the primary circuit of nuclear power plants
Measures to monitor or prevent corrosion are crucial in nuclear power plants, where significant risks to health and safety can occur if corrosion is left unchecked. Anions corrode metals under high temperature and pressure, therefore their concentrations must be monitored at all times. The analytical challenge in the primary circuit is detection of anions in the μg/L range alongside gram quantities of boric acid and lithium hydroxide. Precise, reliable trace analysis requires the method to be automated as much as possible. The 2060 IC Process Analyzer from Metrohm Process Analytics can measure several anions from a single injection, with combined Inline Preconcentration and Inline Matrix Elimination to measure low anion concentrations precisely and reliably time after time.
- AN-PAN-1056Online monitoring of sodium in industrial power plants
In power plants, corrosion is the greatest enemy. If corrosive impurities are present in the circuit streams (e.g., chlorides and hydroxides), deposition of an insulating layer of scale on the heat transfer surfaces occurs, resulting in costly and critical downtimes. To ensure high throughput of power plants, online analysis of critical parameters such as sodium is highly advantageous for safety, protection, and process optimization. With the 2035 Process Analyzer from Metrohm Process Analytics, operators gain the information they need to accurately identify trends, reduce downtimes, and address operational issues before costly problems arise.
- AN-RS-023Trace Detection of Aspartame in Beverages
Some studies suggest that consumption of the artificial sweetener, aspartame, is correlated with increased risk for brain and hematopoietic cancers, however, others find it to be a safe food additive. Consequently, the US and EU approve aspartame as a multi-purpose sweetener with an acceptable daily intake of 40 mg/kg body weight/day. However, the clear health hazard to individuals suffering from phenlyketonuria and ongoing criticism by health food advocates continues to fuel the challenge against aspartame’s widespread use in the food industry.Using Misa (Metrohm Instant SERS Analyzer), beverage products are screened for aspartame levels with no sample preparation beyond simple dilution of a consumer product.
- AN-NIR-095Quality Control of Hand Sanitizers
- AN-PAN-1016Siliziumdioxid in Kesselspeisewasser
Übermässige Konzentrationen an Siliziumdioxid in Kesselspeisewasser können zu Ablagerungen an Turbinenblättern führen und müssen deshalb vermieden werden. Die Siliziumdioxidanalyse erfolgt mittels Differentialphotometrie und einem thermostatischen Küvettenmodul der Spitzentechnologie für berührungslosen Kontakt am Detektor. Typische Konzentrationsbereiche für Siliziumdioxid liegen bei 0–50 ppb und 0–1 ppm oder höher.
- AN-M-017IC-MS/MS-Analyse von Trifluoressigsäure nach DIN 38407-53
Der neue Entwurf der DIN-Norm 38407-53 beschreibt die TFA-Analyse in Wasser mittels Direktinjektion und LC-MS/MS. Wie in dieser Application Note dargestellt, erlaubt das Verfahren eine Quantifizierung im Bereich von 0,1 bis 3,0 μg/L.
- AN-PAN-1029Monitoring peracetic acid (PAA) in a beverage bottling facility
Precise online monitoring of peracetic acid (PPA) for beverage bottling requires a reliable stainless steel process analyzer.
- AN-RS-016Trace Detection of Potassium Ferrocyanide in Table Salt
Potassium ferrocyanide (KFC) is an anti-caking compound added to table salt. Although this is a common non-toxic food additive, its spectroscopic response is representative of analogous cyanide compounds. Trace detection of other cyanides in food products is essential to the safety of consumers, as they can be toxic at oral consumption levels as low as 20 μg/g.This application demonstrates rapid trace analysis of potassium ferrocyanide in table salt with Misa (Metrohm Instant SERS Analyzer), in a simple assay format with minimal use of laboratory reagents.
- AN-M-015Spurenbestimmung von Halogenessigsäuren, Dalapon und Bromat in Trinkwasser
Bei der Chlorung von Trinkwasser können krebserregende Nebenprodukte entstehen. Die EPA-Methode 557 ermöglicht die Quantifizierung von Halogenessigsäuren im µg/L-Bereich mit der IC-MS/MS-Technologie von Metrohm.
- AN-PAN-1035Online-Analyse von Indigo, Hydrosulfit und weiteren Parametern in Textilfärbebädern
Die Grösse des Indigomoleküls macht es schwierig, synthetische Fasern zu färben. Dagegen können Cellulosefasern mit ihren grösseren Poren, wie im Fall der Baumwolle, Indigomoleküle ohne Weiteres aufnehmen. Indigo ist in Wasser unlöslich, weshalb man es zuerst im stark alkalischen Bad mit Natriumsulfit zum wasserlöslichen Leuko-Indigo reduziert. Für gute Färbeergebnisse ist eine gute Durchlüftung des Bades erforderlich; auch sollte daruf geachtet werden, dass kein Sauerstoffeintrag erfolgt. Die Stoffe müssen zwischen den Eintauchvorgängen in das Farbbad oxidiert werden, um das Indigo in den Poren der Fasern zu fixieren. Für stärkere Färbungen sind mehrere Tauchvorgänge erforderlich. Um eine qualitativ hochwertige Färbung zu erzielen, müssen zahlreiche Parameter überwacht und gesteuert werden, vom pH-Wert für die richtige NaOH-Dosierung, der Hydrosulfit- und Indigokonzentration bis hin zur Temperatur und zum Redoxpotential des Bades.
- AN-RS-028SERS Detection of Brilliant Blue
Brilliant Blue (BB) FCF, more commonly known as FD&C Blue #1, is the most commonly used blue dye worldwide for food and beverages. It is generally accepted as safe and non-toxic. Aside from foods labelled as organic or as free from artificial dyes, there is little objection to the use of BB at levels at or exceeding 100 μg/g in foods.This application for Misa (Metrohm Instant SERS Analyzer) is unique. The benefit is twofold — successful detection of a fluorescent dye, and a unique sample cleanup technique that permits detection of a target that does not exhibit a strong SERS signal and is present in a complex matrix. While Misa successfully detects BB in direct sampling, this application describes a simple extraction method that improves detectability of BB with Misa.
- AN-U-049Analyse von Bromat in Trinkwasser gemäß ISO 11206 und EPA 317
Die Ionenchromatographie mit PCR und UV/VIS-Detektion bietet eine hochspezifische und empfindliche Methode für die Bromatanalyse, die den Anforderungen der EPA-Methode 317 und der ISO 11206 entspricht.
- AN-PAN-1009Gleichzeitige Analyse von Ammoniak, Nitrat und Nitrit.
Diese Process Application Note beschäftigt sich mit den Online-Messungen von Ammoniak, Nitrit und Nitrat in Abwasseranlagen. Dabei werden NH3, NO3- und NO2- mittels einer driftfreien kolorimetrischen Messung bestimmt.
- AN-NIR-073Bestimmung der Wasseraktivität in Tabletten mit dem OMNIS NIR Analyzer
Die Wasseraktivität ist ein wichtiger Parameter für die Messung der Qualität und Stabilität nicht steriler Arzneimittel. Der OMNIS NIR Analyzer liefert diese Daten innerhalb von Sekunden.
- AN-S-354Anionen in Abwasser mit dem Eco IC
Der Eco IC ist ein Einstiegsgerät, das sich besonders für den Routinebetrieb und die Wasseranalytik eignet. Es ist mit einem Leitfähigkeitsdetektor ausgerüstet und kann sowohl mit als auch ohne chemische Suppression eingesetzt werden. Diese Applikation beschreibt die Bestimmung des Anionengehaltes mit der Säule Metrosep A Supp 17 - 250/4.0. Dieser Säulentyp ist besonders für die Wasseranalyse bei Raumtemperatur geeignet.
- AN-RS-020Trace Detection of Auramine O in Curry Powder
Auramine O (AO) is an industrial dye used for a broad range of manufactured products and as a fluorescent stain for detecting acid-fast bacteria in clinical specimens. Due to its intense yellow coloration, AO is also prized as an additive for enhancing the visual appeal of illicitly processed food products. Despite bans on AO as a food additive, surveillance testing indicates its persistent use as an adulterant in foods and spices.Misa (Metrohm Instant SERS Analyzer) achieves the rapid and sensitive detection of AO in curry powder in a simple assay format.
- AN-RS-025Trace Detection of Paraquat in Tea Leaves
Paraquat is a highly effective, yet exceptionally toxic herbicide used to manage weeds in agricultural operations. In recognition of paraquat’s danger, the EU and several other countries have banned its use for any application, though the US EPA permits its limited use by licensed applicators. Despite tight regulation, paraquat continues to be produced and is liberally used as an herbicide in over 100 countries without regulatory oversight.Testing for paraquat typically requires involved sample processing and analysis by trained chemists using expensive laboratory instruments such as HPLC, CE, and LC/MS. Misa achieves trace level detection of paraquat residue in tea leaves in a fully integrated, portable, smart system for easy on-site testing by non-technicians.
- AN-S-404Prüfung der Wasserqualität mit EPA 300.1
Die Metrosep A Supp 21-Säule und das 948 Continuous IC Module, CEP ermöglichen eine effiziente, automatisierte Single-Run-Analyse von Hauptanionen und Desinfektionsnebenprodukten in Wasser.
- AN-M-013Chromspeziation mittels IC-ICP-MS
Die Unterscheidung zwischen Cr(III) und Cr(VI) ist gemäß den Richtlinien der ISO 24384 durch die Kombination von Ionenchromatographie und induktiv gekoppelter Plasma-Massenspektrometrie möglich.
- AN-PAN-1026Mercaptane und Hydrogensulfid in Rohöl gemäss ASTM D3227 und UOP163
Rohöl enthält mehrere Gewichtsprozent an Schwefelverbindungen. Sie riechen nicht nur unangenehm, sie sind auch umweltschädigend und korrosiv, weshalb sie in der Raffinierung weitgehend entfernt werden müssen. Der 2045TI Ex proof Analyzer mit einem flexiblen Probenvorbehandlungssystem ist in den verschiedensten Bereichen der Raffinierung zu finden. Zum einen kontrolliert er den Gehalt an Mercaptanen und H2S gemäss der ASTM D3227 und UOP163, zum anderen lassen sich u. a. der Ammoniak-, Halogen- und Phenolgehalt sowie der Bromidindex, Verseifungs- und Säurezahl bestimmen. Der Analysator erfüllt die EU-Richtlinie 94/9/EC (ATEX95) und ist für Zone 1 und 2 zertifiziert.
- AN-PAN-1046Online-Bestimmung von Anionen in 50% NaOH und 50% KOH durch IC (ASTM E1787-16)
Die chemische Grundstoffindustrie ist für die Herstellung tausender Rohmaterialien in sehr grossem Umfang verantwortlich. Die nachgelagerten Branchen sind für die Herstellung ihrer eigenen Waren auf ein bestimmtes Mass an chemischer Reinheit angewiesen, denn gewisse Verunreinigungen können bei verschiedenen Prozessen zu ernsthaften Problemen führen. Bei der Herstellung der chemischen Grundstoffe NaOH und KOH ergibt sich durch die Elektrolyse von gesättigten Salzlösungen mithilfe einer Membranzelle ein Produkt, dessen Konzentration durch Verdunsten weiter erhöht wird. Die Konzentration der Verunreinigungen, die in der verwendeten Salzlösung vorhanden sind, erhöht sich ebenfalls. Normalerweise wird die Analyse dieser Verunreinigungen mit verschiedenen gefährlichen Chemikalien von unterschiedlicher Haltbarkeit durchgeführt, wenn sich das System nicht in Betrieb befindet. Der Process Ion Chromatograph ist in der Lage, die in ASTM E1787-16 beschriebene Online-Messung durchzuführen und so für ein hochwertiges Produkt zu sorgen, ohne dass zeitaufwendige, gefährliche Laborexperimente erforderlich sind.
- AN-NIR-122Quantifizierung von Wasser in Laktose mit dem OMNIS NIR Analyzer
Diese Application Note zeigt, wie einfach es ist, den Wassergehalt im pharmazeutischen Hilfsstoff Laktose mit reagenzienfreier Nahinfrarotspektroskopie zu bestimmen.
- AN-RS-022Trace Detection of Carbendazim on Strawberries
Carbendazim (MBC) is a common fungicide approved for regulated use in agriculture globally, outside of the EU. Most MBC is found on fruits as surface contamination, the result of sprays applied prior to harvest. The US EPA has determined that a concentrations below 80 μg/mL in orange juice are not a health risk, while the EU restricts MBC levels to 10 ng/g (from imported produce) in foods intended for baby food production.This Application Note describes a very simple test for surface MBC and provides library spectra demonstrating the sensitive detection of MBC with Misa (Metrohm Instant SERS Analyzer).
- AN-T-244Standardization of sodium thiosulfate
The OMNIS Titrator equipped with a Pt Titrode accurately and reliably determines titer concentration even in diluted titrants as shown in this Application Note.
- AN-PAN-1034Analyse von Bayer-Aluminatlauge durch thermometrische Titration
Das Bayer-Verfahren erzeugt hochreines Aluminiumoxid aus Bauxit, das durch Schmelzelektrolyse in Aluminium überführt wird. Das feingemahlene Bauxit wird mit Calciumoxid und Natronlauge bei hohen Temperaturen aufgeschlossen. In der alkalischen Lösung reagiert Calciumoxid mit dem Kohlendioxid der Luft zu Calciumcarbonat. Dieses und weitere Verunreinigungen in der Bayer-Lauge reduzieren die Aluminiumausbeute, weshalb die Überwachung der Laugenzusammensetzung sehr wichtig ist, umso mehr, da die Lauge nach Abfiltern des Aluminiumoxids recycelt wird. Dies setzt voraus, dass die Hydroxyl-, Carbonat- und Aluminiumoxidkonzentrationen in der Lauge bekannt sind. Diese Parameter lassen sich bequem mit dem 2035 Process Analyzer mithilfe der thermometrischen Titration bestimmen.
- AN-RS-014Trace Detection of Rhodamine B in Cayenne Powder
Rhodamine B is a dye utilized extensively in biotechnology and industrial applications and is one of several colorants banned for use as food additives in Europe and North America. The most common analytical methods for detection of illicit dyes in food products, GC/MS and HPLC, are laboratory-based instrumental methods that require specialized training.With Misa (Metrohm Instant SERS Analyzer), detection of trace amounts of Rhodamine B in ground cayenne pepper is quick and easy after a facile extraction procedure with minimal material consumption. Rhodamine B can be detected in cayenne powder at a concentrations as low as 10 µg/g.
- AN-RS-019SERS Detection of Metanil Yellow in Turmeric
Metanil yellow (MY) is an azo dye used in the manufacture of external-use products such as textiles; however, it is prohibited from use as a food additive in many countries. Toxicology studies demonstrate that ingestion of MY results in significant neurological and multi-organ damage. Despite these hazards, MY is commonly used as an illicit colorant for enhancing the visual appeal of spices and legumes, most notably turmeric. Ideal tests for such food adulterants feature methods that are selective and sensitive, yet portable and convenient.Misa (Metrohm Instant SERS Analyzer) achieves rapid and accurate detection of MY in a facile assay format.
- AN-D-003Qualitätskontrolle von Dialysekonzentraten
Die Ionenchromatographie (IC) bietet eine automatisierte, schnelle und empfindliche Lösung zur gleichzeitigen genauen Quantifizierung kationischer und anionischer Komponenten, einschließlich Acetat. Dieser umfassende Ansatz macht IC zu einer wirtschaftlichen Alternative zu herkömmlichen Techniken zur Qualitätskontrolle pharmazeutischer Lösungen wie Hämodialysekonzentrate. Benutzerfreundlichkeit, Genauigkeit und der hohe Durchsatz von IC steigern die Produktivität und erfüllen die Anforderungen moderner Routine- und Forschungslabore.
- AN-RS-021Trace Detection of Erythrosine B in Sugar
Erythrosine B (EB), also known as Red Dye #3, is a synthetic dye approved for use in candy in the US, and in pharmaceuticals and cosmetics in the EU and elsewhere. However, rodent studies suggest that ingestion of EB can promote thyroid tumor formation. EB may also be implicated as a dietary factor contributing to hyperkinesis in children. WHO recommends a daily intake of EB less than 0.1 mg/kg of body weight.The ability to obtain fast results with a portable test platform recommends Misa (Metrohm Instant SERS Analyzer) as a competitive and cost-effective alternative to laboratory technologies (e.g., CE, HPLC) currently employed for detecting EB in foodstuffs.
- AN-CIC-033Überwachung von PFAS in Wasserquellen
AOF (adsorbierbares organisches Fluor) wird zum Screening auf per- und polyfluorierte Alkylsubstanzen in wässrigen Matrices mittels pyrohydrolytischer Verbrennung und Ionenchromatographie verwendet.
- AN-CIC-034Schnelle Analyse von AOX in Gewässern durch CIC
Die Combustion Ionenchromatographie (CIC) misst AOX (adsorbierbare organisch gebundene Halogene, d.h. AOCl, AOBr, AOI) und AOF sowie CIC AOX(Cl) nach DIN 38409-59 und ISO 18127.
- AN-RS-017Trace Detection of Thiabendazole on Bananas
Thiabendazole (TBZ) is a broad-spectrum pesticide used both as a fungicide in fruits and vegetables and for controlling parasites in animal feed. To ensure consumer safety, regulatory agencies establish maximum residue levels (MRL) for pesticide-treated crops based on their review of risk assessment studies. For bananas, which are either aerially sprayed or dipped in protectant solutions of TBZ, the US FDA reports a MRL of 3 μg/g, and the EU stipulates a MRL of 6 μg/g by weight.With Misa (Metrohm Instant SERS Analyzer), the rapid and sensitive detection of TBZ on bananas is demonstrated in formats easily adapted for food safety surveillance testing.
- AN-RS-030Trace Detection of Fenthion in Olive Oil
Fenthion is a multi-purpose insecticide used in many countries for mosquito control. To minimize human exposure and the unintentional poisoning of wildlife, the US EPA has classified fenthion as a restricted-use insecticide. However, the widespread spraying of olive orchards in Mediterranean countries results in olive oils that occasionally exceed the maximum residue limits established for olives.Misa (Metrohm Instant SERS Analyzer) easily achieves sensitive trace detection of fenthion in spiked olive oil after a simple organic solvent extraction. This Application Note presents an excellent example of how the signal from SERS substrates can compete with the target signal at very low levels of detection.
- AN-PAN-1013Online-Analyse von Borsäure im Kühlwasser von Druckwasserreaktoren
Borsäure erfordert eine genaue Überwachung im Primärkreislauf, um die Reaktivität des Kernreaktors zu kontrollieren. Der 2060 TI Process Analyzer überwacht Borsäure online und nahezu in Echtzeit.
- AN-NIR-016Nahinfrarotspektroskopie zur Überwachung eines Eintopfgranulierers
Dieses Application Note beschreibt die Einsatzmöglichkeiten eines neuen Sensordesigns, welches es in Kombination mit einem NIRS XDS Process Analyzer erlaubt, Restmengen von Lösungsmittel während der Trocknungsphase in einem High-Shear Granulator zu bestimmen. Diese Systemkonfiguration reduziert die Streuung der Dichteverteilung der Pulverproben, so dass es direkt im Prozess möglich ist, Wasser- und Lösungsmittelgehalt präzise zu modellieren.
- AN-PAN-1059Online analysis of strontium and barium in high purity brine
This Process Application Note describes a method to determine the strontium and barium concentration in brine as early detectors ofmembrane fouling via online process ion chromatography. Using this multiparameter analytical technique can help reduce the risk of premature membrane fouling and avoid unexpected maintenance and high utility costs with 24/7 automated analysis.
- AN-V-213Kupfer im Trinkwasser
Höhere Kupferwerte im Trinkwasser entstehen üblicherweise durch die korrosive Wirkung des Wassers, das Kupfer aus den Kupferrohren auslaugt. Obwohl Kupfer für den menschlichen Organismus ein wichtiger Nährstoff ist, wirkt sich die Einnahme höherer Konzentrationen negativ auf die menschliche Gesundheit aus. Die aktuellen «Richtlinien für Trinkwasserqualität» der Weltgesundheitsorganisation empfehlen eine maximale Konzentration von 2000 μg/l. Mit einer Nachweisgrenze (LOD) von 0,5 μg/l ist die anodische Stripping-Voltammetrie eine praktikable, weniger anspruchsvolle Alternative zur Atomabsorptionsspektroskopie (AAS) zur Bestimmung von Kupfer in Trinkwasser. Während AAS (und konkurrierende Methoden) nur in einem Labor durchgeführt werden können, kann die anodische Stripping-Voltammetrie konventionell im Labor oder alternativ vor Ort mit dem tragbaren 946 VA Analyzer verwendet werden. Die Bestimmung erfolgt auf der scTRACE Gold-Elektrode.
- AN-V-218Bismut in Trinkwasser
Bismut gilt als Metall mit sehr geringer Toxizität. In hohen Konzentrationen wurden jedoch toxische Wirkungen beschrieben. In den «Leitlinien für Trinkwasserqualität» der Weltgesundheitsorganisation gibt es für Bismut keinen Richtwert, da die im Trinkwasser üblicherweise vorkommenden Konzentrationen unbedenklich sind. Die anodische Stripping-Voltammetrie ist eine praktikable, weniger aufwändige Alternative zur Atomabsorptionsspektroskopie (AAS) zur Bestimmung von Bismut in Trinkwasser. Während AAS (und konkurrierende Methoden) nur in einem Labor durchgeführt werden können, kann die anodische Stripping-Voltammetrie im Labor oder alternativ vor Ort mit dem handheld VA-Analyzer 946 verwendet werden. Die Bestimmung erfolgt auf der scTRACE Gold-Elektrode.
- AN-V-210Gesamtarsen in Mineralwasser
Arsen ist in geringen Konzentrationen in der Erdkruste allgegenwärtig. Erhöhte Konzentrationen können in Mineralvorkommen und Erzen vorkommen. Arsen aus solchen Lagerstätten gelangt in Form von Arsenit (AsO33–) und Arsenat (AsO43–) ins Grundwasser und verursacht dessen Verunreinigung. Neben dem aus natürlichen Quellen stammenden Arsen tragen auch Industrie und Landwirtschaft in geringerem Maße zur Belastung bei. Der Richtwert für anorganisches Gesamtarsen ist in den «Leitlinien für Trinkwasserqualität» der Weltgesundheitsorganisation auf 10 μg/L festgelegt. Mit einer Nachweisgrenze (LOD) von 0,9 μg/l ist die anodische Stripping-Voltammetrie eine praktikable, weniger anspruchsvolle Alternative zur Atomabsorptionsspektroskopie (AAS) zur Bestimmung von Arsen. Während AAS (und konkurrierende Methoden) nur in einem Labor durchgeführt werden können, kann die anodische Stripping-Voltammetrie konventionell im Labor oder alternativ vor Ort mit dem tragbaren VA-Analysator 946 verwendet werden. Die Bestimmung erfolgt auf der scTRACE Gold Elektrode.
- AN-V-212Quecksilber in Mineralwasser
Quecksilber und seine Verbindungen sind giftig. Das größte Risiko geht von einer chronischen Vergiftung mit über die Nahrung aufgenommenen Quecksilberverbindungen aus. Ein erheblicher Teil des in der Umwelt vorhandenen Quecksilbers ist anthropogenen Ursprungs. Wesentliche Quellen sind Kohlekraftwerke, die Stahl- und Nichteisenmetallproduktion, Müllverbrennungsanlagen, die chemische Industrie oder der handwerkliche Goldbergbau, wo die Verwendung von elementarem Quecksilber zur Gewinnung von Gold aus dem Erz immer noch üblich ist. Der Richtwert für anorganisches Quecksilber in den „Leitlinien für Trinkwasserqualität“ der Weltgesundheitsorganisation ist auf 6 μg/l festgelegt. Mit einer Nachweisgrenze (LOD) von 0,5 μg/l ist die anodische Stripping-Voltammetrie eine praktikable, weniger anspruchsvolle Alternative zur Atomabsorptionsspektroskopie (AAS). Während AAS (und konkurrierende Methoden) nur in einem Labor durchgeführt werden können, kann die anodische Stripping-Voltammetrie konventionell im Labor oder alternativ vor Ort mit dem tragbaren VA Analyzer 946 angewandt werden. Die Bestimmung erfolgt auf der scTRACE Gold-Elektrode.
- AN-V-216Eisen in Trinkwasser
Eisen ist ein essentieller Bestandteil der menschlichen Ernährung. Es kann durch die Wasseraufbereitung oder durch Korrosion im Wasserleitungssystem in Trinkwasser vorhanden sein. In den «Leitlinien für Trinkwasserqualität» der Weltgesundheitsorganisation gibt es keinen Richtwert für Eisen, da die im Trinkwasser üblicherweise vorkommenden Konzentrationen unbedenklich sind. Allerdings gibt es in verschiedenen Ländern nationale Grenzwerte. Die Europäische Union hat einen Richtwert für Eisen von 200 μg/l festgelegt. Die Voltammetrie ist eine praktikable, weniger aufwändige Alternative zur Atomabsorptionsspektroskopie (AAS) zur Bestimmung von Eisen im Trinkwasser. Während AAS (und konkurrierende Methoden) nur in einem Labor durchgeführt werden können, können voltammetrische Bestimmungen mit anodischer Stripping-Methode konventionell im Labor oder alternativ vor Ort mit dem tragbaren VA-Analysator 946 durchgeführt werden. Die Bestimmung erfolgt mittels adsorptiver Stripping-Voltammetrie (AdSV) unter Verwendung von 2,3-Dihydroxynaphthalin (DHN) auf der scTRACE Gold-Elektrode.
- AN-V-217Nickel, Kobalt in Trinkwasser
Nickel wird häufig bei der Herstellung von Edelstahl verwendet. Es ist bekannt, dass es bei ausreichend hohen Konzentrationen bei Hautkontakt allergische Reaktionen hervorruft. Durch Wasserhähne aus nickelhaltigen Metallen kann es zu einer Verunreinigung des Trinkwassers kommen. Der Richtwert für Nickel ist in den «Leitlinien für Trinkwasserqualität» der Weltgesundheitsorganisation auf 70 μg/L festgelegt. Nationale Grenzwerte liegen typischerweise niedriger bei z.B. 20 μg/l. Kobalt kommt meist in Verbindung mit Nickel vor und kann auch in geringeren Konzentrationen neben Nickel vorkommen. Die adsorptive Stripping-Voltammetrie ist eine praktikable, weniger aufwändige Alternative zur Atomabsorptionsspektroskopie (AAS) zur Bestimmung von Nickel und Kobalt in Trinkwasser. Während AAS (und konkurrierende Methoden) nur in einem Labor durchgeführt werden können, können adsorptive Stripping-Voltammetriebestimmungen im Labor oder alternativ vor Ort mit dem tragbaren VA-Analyzer 946 durchgeführt werden. Die Bestimmung erfolgt auf einem auf der scTRACE Gold-Elektrode aufgebrachten Wismutfilm.
- AN-V-230Chrom(VI) in Trinkwasser
Der Richtwert für Gesamtchrom in den «Leitlinien für Trinkwasserqualität» der Weltgesundheitsorganisation (WHO) beträgt 50 µg/L. Chrom(VI) ist giftiger als seine dreiwertige Form (Cr(III)) und kommt auch seltener vor. Daher ist eine robuste und empfindliche Methode erforderlich, um die Konzentration im Trinkwasser zu überwachen. Die mit einem Quecksilberfilm modifizierte scTRACE Gold kann zur Überwachung von Chrom(VI) eingesetzt werden und bietet eine einfache Handhabung und ein hohes Maß an Stabilität.
- AN-V-214Blei im Trinkwasser
Blei gilt als hochgiftig für den Menschen, da es Enzymreaktionen stört. Eine chronische Bleivergiftung kann durch das Austreten von Blei aus Rohrleitungssystemen ins Trinkwasser verursacht werden. Der aktuelle, vorläufige Richtwert in den «Leitlinien für Trinkwasserqualität» der Weltgesundheitsorganisation legt eine maximale Konzentration von 10 μg/L fest. Mit einer Nachweisgrenze (LOD) von 0,2 μg/l ist die anodische Stripping-Voltammetrie eine praktikable, weniger anspruchsvolle Alternative zur Atomabsorptionsspektroskopie (AAS) zur Bestimmung von Blei im Trinkwasser. Während AAS (und konkurrierende Methoden) nur in einem Labor durchgeführt werden können, kann die anodische Stripping-Voltammetrie konventionell im Labor oder alternativ vor Ort mit dem tragbaren VA-Analysator 946 verwendet werden. Die Bestimmung erfolgt auf einem auf der scTRACE Gold-Elektrode aufgebrachten Silberfilm.
- AN-V-227Chrom(VI) in Trinkwasser
Der Richtwert für Chrom in den «Leitlinien für Trinkwasserqualität» der Weltgesundheitsorganisation (WHO) beträgt 50 µg/L. Dabei ist zu beachten, dass Chromkonzentrationen häufig als Gesamtchrom und nicht als Chrom(III) oder (VI) angegeben werden. Chrom(VI) ist für Veränderungen des Erbguts verantwortlich und kommt in deutlich geringeren Konzentrationen vor als Cr(III). Daher ist eine äußerst empfindliche Methode erforderlich, um Cr(VI) im Trinkwasser zu überwachen. Zur Bestimmung solch niedriger Konzentrationen kann die leistungsstarke adsorptive Stripping Voltammetrie (AdSV) an einer ex-situ mit Quecksilberfilm modifizierten Glaskohlenstoffelektrode unter Verwendung von DTPA als Komplexbildner eingesetzt werden.
- AN-V-231Cadmium und Blei in Trinkwasser
Die vorläufigen Richtwerte in den «Leitlinien für Trinkwasserqualität» der Weltgesundheitsorganisation (WHO) liegen bei 3 µg/L für Cadmium und 10 µg/L für Blei. Mithilfe der anodischen Stripping-Voltammetrie (ASV), die an der ex situ mit Quecksilberfilm modifizierten Metrohm DropSens-Siebdruckelektrode (SPE) durchgeführt wird, können Konzentrationen beider Elemente im niedrigen Bereich von 0,3 µg/l gleichzeitig erkannt werden. Dies ist geeignet um die Richtwerte der WHO zu überwachen. Der Hauptvorteil dieser Methode liegt in der innovativen und kostengünstigen Siebdruckelektrode.
- AN-T-243Sulfite determination in beet sugar
This study presents the automatic titration of low sulfite levels in beet crystal sugar using an OMNIS Titrator and a Pt Titrode as the potentiometric sensor.
- AN-V-221Cadmium und Blei in Trinkwasser
Um die toxischen Auswirkungen von Cadmium auf den menschlichen Körper zu verringern und die neurotoxischen Wirkungen von Blei zu begrenzen, sind die vorläufigen Richtwerte in den «Leitlinien für Trinkwasserqualität» der Weltgesundheitsorganisation auf eine maximale Konzentration von 3 µg/L für Cadmium und 10 µg/L für Blei festgelegt. Die völlig quecksilberfreie Bi-Tropfenelektrode ist der nächste Schritt bei der Umwandlung der voltammetrischen Analyse in einen ungiftigen Ansatz zur Schwermetallerkennung. Der Einsatz dieses umweltfreundlichen Sensors für die anodische Stripping-Voltammetrie (ASV) ermöglicht die gleichzeitige Bestimmung von Cd und Pb in Trinkwasser. Die hervorragende Sensitivität ist zur Überwachung der vorläufigen WHO-Richtwerte mehr als ausreichend.
- AN-V-224Nickel und Kobalt in Trinkwasser
Aufgrund der Toxizität und der schädlichen Auswirkungen von Nickel und Kobalt auf die menschliche Gesundheit muss ihre Konzentration im Trinkwasser kontrolliert werden. Daher legt die EU-Gesetzgebung einen Grenzwert für Nickel im Trinkwasser von 20 µg/L fest. Der aktuelle, vorläufige Richtwert für Ni in den «Leitlinien für Trinkwasserqualität» der Weltgesundheitsorganisation ist auf eine maximale Konzentration von 70 µg/L festgelegt. Zur Überwachung der Konzentrationen von Ni und Co mit dem 884 Professional VA wird eine Methode zur simultanen Bestimmung an der mit einem Bi-Film modifizierten Glaskohlenstoffelektrode (GC-RDE) verwendet.
- AN-V-225Cadmium und Blei in Trinkwasser
Um die toxischen Auswirkungen von Cadmium auf Nieren, Skelett und Atmungssystem sowie die neurotoxischen Auswirkungen von Blei zu verringern, sind die vorläufigen Richtwerte in den „Leitlinien für die Trinkwasserqualität“ der Weltgesundheitsorganisation (WHO) auf eine maximale Konzentration von 3 µg/l für Cadmium und 10 µg/l für Blei festgelegt. Die leistungsstarke anodische Stripping-Voltammetrie (ASV) mit der ex situ mit Quecksilberfilm modifizierten Glaskohlenstoffelektrode ist mehr als ausreichend, um die vorgeschlagenen WHO-Leitlinien für Cd und Pb im Trinkwasser zu überwachen.
- AN-V-232Nickel und Kobalt in Trinkwasser
Als Grenzwert für Nickel in Trinkwasser legt die EU-Gesetzgebung 20 µg/L fest. Der aktuelle, vorläufige Richtwert für Ni in den «Leitlinien für Trinkwasserqualität» der Weltgesundheitsorganisation ist auf eine maximale Konzentration von 70 µg/L festgelegt. Mithilfe der adsorptiven Stripping-Voltammetrie (AdSV), die an der ex-situ mit Wismutfilm modifizierten siebgedruckten Elektrode (SPE) Metrohm DropSens 11L durchgeführt wird, lassen sich bei einer Ablagerungszeit von 30 s gleichzeitig Konzentrationen von nur 0,4 µg/l Nickel und 0,2 µg/l Kobalt erkennen. Der wartungsfreie Einwegsensor kann konventionell im Labor mit dem 884 Professional VA oder alternativ vor Ort mit dem handheld VA Analyzer 946 verwendet werden. Diese Methode eignet sich am besten für manuelle Systeme.
- AN-V-233Selen(IV) in Trinkwasser
Der Unterschied zwischen den für die menschliche Gesundheit toxischen und essentiellen Selenwerten ist sehr gering. Daher ist der aktuelle vorläufige Richtwert für Selen(IV) in den «Leitlinien für Trinkwasserqualität» der Weltgesundheitsorganisation und in der europäischen Trinkwasserrichtlinie auf eine maximale Konzentration von 10 µg/L festgelegt. Mit der anodischen Stripping-Voltammetrie (ASV) des unveränderten scTRACE Gold lassen sich bei einer Ablagerungszeit von 30 s so niedrige Konzentrationen wie 0,5 µg/L Selen bestimmen. Durch eine Erhöhung der Abscheidungszeit können diese Grenzwerte noch weiter gesenkt werden. Der lineare Bereich bei 30 s Depositionszeit endet bei ca. 100 μg/L. Die scTRACE Gold-Elektrode erfordert keine aufwändige Wartung wie etwa mechanisches Polieren. Messungen können im Labor mit dem 884 Professional VA oder alternativ vor Ort mit dem 946 Portable VA Analyzer durchgeführt werden. Diese Methode eignet sich für manuelle oder automatisierte Systeme.
- AN-V-234Tellur(IV) in Trinkwasser
Tellur ist eines der Elemente, die vor kurzem als technologisch entscheidend für die Umwandlung in Photovoltaik, Quantenpunkte und die thermoelektrische Technologie identifiziert wurden und das Potenzial haben, zu einem neuen Schadstoff zu werden. In den «Leitlinien für Trinkwasserqualität» der Weltgesundheitsorganisation und in der europäischen Trinkwasserrichtlinie gibt es bislang keinen Richtwert für die Tellur(IV)-Konzentration in Trinkwasser. Zur Überwachung des Tellur(IV)-Gehalts im Trinkwasser wird die anodische Stripping-Voltammetrie (ASV) mit der unveränderten scTRACE Gold empfohlen. Mit dieser Methode ist die Bestimmung von Tellur(IV) im Konzentrationsbereich zwischen 1 µg/L und 60 µg/L bei einer Abscheidungszeit von 90 s möglich. Die scTRACE Gold-Elektrode erfordert keine aufwändige Wartung wie etwa mechanisches Polieren. Messungen können im Labor mit dem 884 Professional VA oder alternativ vor Ort mit dem 946 Portable VA Analyzer durchgeführt werden.
- AN-I-029Dissolved oxygen in wine
Dissolved oxygen (DO) is generally considered detrimental to wine quality, especially if introduced after fermentation, storage, or bottling. The presence of oxygen after primary fermentation and during the later stages of winemaking can enhance browning reactions, chemical and microbiological instability, and the formation of off-flavors such as acetaldehyde. Knowing the DO content in wine is important through the entire wine production process, because oxidation is a common fault in bottled wines. With the 913 pH/DO meter and the 914 pH/DO/Conductometer, the oxygen content of wine can be determined quickly and easily directly on site.
- AN-I-027Dissolved oxygen in fruit juices
Dissolved oxygen (DO), incorporated into juices during processing, affects quality parameters of the beverage during storage such as Vitamin C concentration, color, and aroma. Various oxygen removal methods are used during juice production, such as vacuum-deaeration or gas sparging to increase product quality and extend shelf life. However, these methods have the drawback that the aroma might be affected since the volatile compounds are also removed. By assessing the DO content in fruit juices, manufacturers can improve the overall product quality. This application note describes a fast and accurate determination of dissolved oxygen in juices by using an optical sensor.
- AN-NIR-151Moisture and protein content in corn starch with NIR spectroscopy
Corn starch serves as a gelling and thickening agent in the confectionary industry. It is also an ideal reusable molding and drying medium for starch-molded candies, where its moisture content is critical to monitor. Near-infrared spectroscopy (NIRS) provides a rapid, reagent-free method to determine moisture and protein content in corn starch. The technique is straightforward to operate and suitable for atline monitoring or routine quality control laboratories.
- AN-T-245Photometric determination of ionic surfactants by two-phase titration
Accurate, reliable determination of ionic surfactants with the Epton two-phase titration method can be achieved using an OMNIS system as shown in this study.
- AN-RS-012Verhindern von Säureangriffen – Identifikation von Säuren durch einen neuartigen Kunststoffbehälter
Säureattentate, eine historische Vergeltungsmassnahme gegen Frauen, sind zu einer modernen Bedrohung ganz anderer Art geworden. Konzentrierte Säuren und andere ätzende Stoffe haben sich zu modernen Werkzeugen sozialer Gewalt entwickelt. Angreifer nutzen gewöhnliche Kunststoffbehälter mit Öffnungen, die einen starken, zielgerichteten Strahl erzeugen, wie z. B. Spritzflaschen von Zitronensaft. Aufgrund ihrer hochkorrosiven Eigenschaften wurden hier Schwefel- und Phosphorsäure für die Analyse gewählt ‒ bei Säureangriffen in London wurden am häufigsten Schwefel-, Phosphor- und Salpetersäure eingesetzt. Im Jahr 2017 kam es im Vereinigten Königreich mit durchschnittlich zwei gemeldeten Vorfällen pro Tag zu einer ungewöhnlich hohen Anzahl an Säureangriffen. Die Erkennung und Regulierung von Säuren könnte dazu beitragen, dieses gesellschaftliche Übel zu verhindern.
- AN-RS-027Trace Detection of Thiram on Apples
Thiram is used extensively as a fungicide and parasiticide to prevent disease in crops and as an animal repellent to protect trees and ornamental plants. However, extensive toxicological studies conclude that chronic, high-level exposure can cause considerable organ damage to land and aquatic species. The US defines maximum residue limits that vary for different food crops. In contrast, the EU recently banned thiram and is moving to use pesticides that carry reduced health risks.Using Misa (Metrohm Instant SERS Analyzer), low level detection of thiram on apples is achieved with guided workflows adapted for use by diverse testers.
- AN-NIR-035Quality control of polyols with NIRS
Polyols are widely used as polyurethane feedstocks, where tight quality control of parameters such as hydroxyl value, acid number, moisture, and viscosity is essential. Conventional titration methods are standardized but slow and costly due to hazardous chemicals and waste handling. Near-infrared spectroscopy (NIRS), recognized by ASTM for hydroxyl value determination, enables rapid, reagent-free, multiparameter analysis of polyols with significantly lower operating costs.
- AN-RS-024Trace Detection of Pyrimethanil in Wine
Pyrimethanil is a broad-spectrum fungicide. As grapevines are susceptible to fungal pathogens, large-scale viticulture operations apply pyrimethanil as part of a mixed treatment. Although chemical analysis of wines post-fermentation finds low to undetectable amounts of residue, pyrimethanil is a suspected human carcinogen. The US FDA and EU have therefore established a maximum permissible level of 5 μg/mL pyrimethanil in finished wine products.In this application, trace detection of pyrimethanil in wine with Misa (Metrohm Instant SERS Analyzer) requires few laboratory supplies and minimal sample processing, yet returns rapid results.
- AN-RS-029Trace Detection of Malathion on Corn
Malathion is an insecticide widely used on a broad spectrum of plant species. Several studies have implicated chronic exposure to malathion in the development of certain cancers. Maximum residue limits for malathion have been enacted by the regulatory agencies of several countries: the US Food and Drug Administration sets maximum residue limits at 8 μg/g in foods, while the EU has a considerably more stringent limit of 20 ng/g.SERS is an accepted method for detection of malathion on fruit and vegetable surfaces. Misa (Metrohm Instant SERS Analyzer), which requires minimal laboratory chemicals and consumables and provides an extremely user-friendly interface, is an excellent SERS solution for trace detection of food adulterants.
- AN-T-246Standardization of cationic surfactants by argentometric titration
The standardization of the cationic surfactant TEGOtrant is performed using potentiometric titration as well as near-infrared spectroscopy (NIRS) in this application.
- AN-RS-026Trace Detection of Diphenylamine in Baby Food
Diphenylamine (DPA) is used as a dye fixative and antioxidant in industrial applications and as a produce preservative in agricultural operations. Food safety advocates are concerned that daily ingestion of DPA, particularly in foods meant for babies, could have negative effects on children’s health. To mitigate potentially toxic effects of DPA, both the US and EU stipulate a maximum residue limit (MRL) of 5 μg/g for whole pears and a stringent MRL of 10 ng/g for all processed baby foods.Misa (Metrohm Instant SERS Analyzer) provides a user-friendly and cost-effective alternative to traditional analytical methods used for detecting DPA in foods, such as GC-MS and GC-NPD.
- AN-RS-056Quantification of methanol in contaminated spirits
Raman spectroscopy is ideally suited to rapidly screen for methanol contamination in spirits.
- AN-S-353Routinemäßige Trinkwasseranalyse
Die Ionenchromatographie (IC) ist die Methode der Wahl, um die Konzentration gewöhnlicher Ionen in Wasser zu bestimmen. Diese Informationen sind von entscheidender Bedeutung, da Trinkwasser bestimmte Standards erfüllen muss, um die Gesundheit (z. B. Nitrit und Nitrat) sowie die technische Eignung (z. B. Korrosivität von Chlorid und Sulfat) zu gewährleisten. Der Eco IC ist ein Ionenchromatograph, der sich für die wirtschaftliche Routinewasseranalyse eignet. Mit einer A Supp 17-Anionensäule ist die Analyse der wichtigsten Anionen in Trinkwasser robust und kann bei Umgebungstemperaturen ohne zusätzliche Temperaturkonditionierung durchgeführt werden.
- AN-EC-040ECL detection of fentanyl
This Application Note presents an electrochemiluminescence (ECL) method for a fast, accessible, and cost-effective alternative method to detect fentanyl.
- AN-EC-038Messung der Ionenleitfähigkeit mittels Siebdrucktechnologie
Mit Hilfe von 11COND-Einweg-Siebdruckelektroden und elektrochemischer Impedanzspektroskopie kann die Leitfähigkeit in Trinkwasser mit nur 100 µl Proben gemessen werden.
- AN-PAN-1002Online-Überwachung von Cyanid und Gold in Goldauslaugungslösungen
Die Goldlaugung durch Cyanidlaugung erfordert eine genaue Überwachung von Cyanid und Gold. Online-Prozessanalysatoren führen solche Messungen durch und verbessern so die Sicherheit und Konformität.
- AN-PAN-1032Korrosionsüberwachung in Kraftwerken mit Online-Prozessanalytik
Korrosion im Wasser-Dampf-Kreislauf von Kraftwerken führt zu einer kürzeren Lebensdauer der meisten Metallkomponenten und zu potenziell gefährlichen Situationen. Ein Sonderfall ist die strömungsbeschleunigte Korrosion (FAC), die zu dünner werdenden Rohren und erhöhten Fe-Konzentrationen im Kreislauf führt. Darüber hinaus können Metalltransportprobleme, wie etwa bei Cu aus Kupferwärmetauschern, zu Ablagerungen auf den Hochdruckturbinenschaufeln führen und deren Effizienz verringern. Aktuelle Methoden können diese Probleme überwachen, aber nicht verhindern, und die Analysezeiten sind extrem lang (bis zu drei Wochen). In Kombination mit dem Distributed Control System (DCS) des Kraftwerks sorgt die Online-Überwachung von Fe und Cu mit dem Prozessanalysator 2060 von Metrohm Process Analytics dafür, dass Korrosion kontrolliert werden kann, bevor sie die Kraftwerkseffizienz beeinträchtigt, was letztlich zu kürzeren Ausfallzeiten und niedrigeren Wartungskosten führt. Die Ergebnisse liegen innerhalb von 20 Minuten vor und ermöglichen schnelle Anpassungen des Wasser-Dampf-Kreislaufs zum Schutz der Unternehmenswerte.
- AN-PAN-1068Online-Elementanalyse von Kupfer, Zinn und Zink in Weißbronzebädern mittels XRF
In dieser Application Note wird erläutert, wie der 2060 XRF Process Analyzer eine chemische Echtzeitüberwachung der Kupfer-, Zinn- und Zinkkonzentrationen in Weißbronze-Beschichtungsbädern ermöglicht.
- AN-M-016Trennung von Halogenessigsäuren in Wasser
Bei der Trinkwasserdesinfektion mit Chlor, Chloramin oder Ozon können potenziell giftige halogenierte Nebenprodukte entstehen. Die Desinfektionsmittel können mit natürlich vorkommenden Bromiden und/oder organischen Stoffen im Quellwasser reagieren und eines der häufigsten und hochgiftigen Desinfektionsnebenprodukte (DBPs) bilden: Halogenessigsäuren (HAAs). Zum Schutz der menschlichen Gesundheit sind die maximal tolerierbaren Mengen an HAA im Trinkwasser reguliert (EPA 816-F-09-004). Die EPA-Methode 557 spezifiziert die Analyse von HAAs neben Bromat und Dalapon durch Ionenchromatographie gekoppelt mit Tandem-Massenspektroskopie (IC-MS/MS) mit LODs zwischen 0,02 und 0,11 µg/L. Allerdings wird auch mit Einzel-MS eine hohe Empfindlichkeit erreicht, um die aktuellen MCLs mit ausreichender Genauigkeit zu bestimmen. Diese Application Note beschreibt die Analyse von Bromat, Chlorit, Monochloressigsäure (MCAA), Monobromessigsäure (MBAA), Bromchloressigsäure (BCAA), Bromdichloressigsäure (BDCAA), Dibromessigsäure (DBAA), Dichloressigsäure (DCAA), Tribromessigsäure ( TBAA), Chlordibromessigsäure (CDBAA) und Trichloressigsäure (TCAA) mit IC/MS. Der Metrohm Driver 2.1 für EmpowerTM bietet die Analyse als einzige Softwarelösung mit EmpowerTM.
- AN-EC-041Studying nickel deposition with EQCM-D and EC-Raman
This application note demonstrates EQCM D for simultaneous mass and dissipation analysis of Ni(OH)₂ electrodeposition.
- 410000051-BIdentifizierung von Mikroplastik mit Raman-Mikroskopie
Forschungslabore müssen ihre Kapazitäten zur routinemäßigen Analyse von Mikroplastikkandidaten aus Umweltproben erweitern, um deren Herkunft zu bestimmen und biologische Auswirkungen vorherzusagen. Spektroskopische Techniken eignen sich gut zur Polymeridentifizierung. Die Labor-Raman-Spektroskopie ist eine Alternative zu konfokalen Raman-Mikroskopen und Fourier-Transformations-Infrarot-Mikroskopen (FTIR) zur schnellen Identifizierung von Polymermaterialien. In dieser Application Note wurde Raman-Mikroskopie verwendet, um sehr kleine Mikroplastikpartikel zu identifizieren.
- AN-S-396Bewertung der Weinqualität mit IC
Die Überwachung des Gehalts an organischen Säuren im Wein ist von entscheidender Bedeutung, um Geschmack und Qualität zu verbessern und universelle standardisierte Kriterien wie den International Code of Oenological Practices zu erfüllen. Analytisch können organische Säuren mit der Ionenchromatographie (IC) und der Detektion der unterdrückten Leitfähigkeit ordnungsgemäß bestimmt werden. Als Mehrkomponentenmethode können auch anorganische Säuren aufgelöst werden, die ebenfalls wertvolle Tracer für Weinqualität und -geschmack sind. In dieser Application Note werden zwei IC-Methoden für die Weinqualitätsanalyse vorgestellt: eine schnelle isokratische Screening-Methode für die wichtigsten organischen Säuren und Anionen, einschließlich Sulfit, und eine komplexe Überwachungsmethode mit einem binären Gradienten zur Trennung von 15 organischen Säuren. Zur wirtschaftlichen Probenaufbereitung wurde die Inline-Ultrafiltration eingesetzt.