重新導向訊息

Total PFAS analysis using Combustion Ion Chromatography

77 min

en

// Environmental

Iris Reber and Theresa Steurer from the Competence Center Ion Chromatography at Metrohm International Headquarters and Dr. Leo Yeung from Örebro University in Sweden present Combustion Ion Chromatography (CIC) as an innovative and robust solution for rapid and straightforward screening of environmental samples for adsorbable organofluorine (AOF) and/or extractable organofluorine (EOF).

填寫表格即可觀看網路研討會

此為必要欄位。

隱私權政策

我允許 Metrohm AG 及其子公司和獨家經銷商根據其隱私權政策存儲和處理我的資料,並通過電子郵件、電話或信件與我聯繫以回覆我的詢問和用於廣告目的。我可以隨時透過發送電子郵件至 info@metrohm.com.tw 撤回此同意。

此為必要欄位。

Combustion ion chromatography for PFAS analysis

Big factory close to a river

Per- and polyfluoroalkyl substances (PFAS) include highly persistent compounds that pose serious environmental concerns. Total PFAS analysis by CIC can provide an accurate picture of the overall PFAS contamination level before more expensive and time-consuming analytical methods are deployed for targeted analysis of specific PFASs.

CIC is a fully automated technique and can be a valuable tool for public authorities and any laboratories in general tasked with PFAS monitoring and the identification of hotspots. Combustion IC is an established method to determine halogens and sulfur in matrices ranging from solids to viscous, liquid, and gaseous samples.

DIN 38409-59 describes CIC as a standardized and validated analysis method for fast, reliable, and robust determination of the sum parameter CIC-AOX(CI) as well as the single fractions AOCl, AOBr, AOI, and AOF.

Learn more about combustion IC

Learn more about DIN 38409-59

Download free white paper

This free white paper presents combustion ion chromatography as a reliable and fast method to accurately determine the sum parameter AOX, including its individual fractions AOCl, AOI, and AOBr, as well as AOF according to DIN 38409-59.

Metrohm IC: More than 30 years of experience

0:00 / 0:00

Metrohm IC covers simple setups for academic laboratories to fully automated, high-performance ion chromatography systems and hyphenated techniques such as IC-MS or IC-ICP/MS. The portfolio includes detectors, inline sample preparation techniques as well as the heart of ion chromatography itself: the separation columns.

Rely on Swiss-made quality and benefit from our global presence in over 80 countries for local support by our service and application experts.

Go to ion chromatographs for the lab

Go to ion chromatograph for process analysis