應用領域
- AB-129电位法测定正磷酸根,偏磷酸根与聚磷酸根
进行酸消解后,用氢氧化钠对样品溶液进行中和生成磷酸二氢钠。 加入过量的硝酸镧,然后使用氢氧化钠溶液对释放出来的硝酸进行滴定。NaH2PO4 + La(NO3)3 -> LaPO4 + 2 HNO3 + NaNO3这种测定方法适用于浓度较高的磷酸盐。
- AB-314Determination of total phosphate in phosphoric acid and phosphate fertilizers with thermometric titration
Phosphate can be rapidly and easily titrated thermometrically using a standard solution of Mg2+ as titrant. The phosphate-containing solution is basified and buffered with NH3/NH4Cl solution before titration. The formation of insoluble MgNH4PO4 is exothermic. The method is a titrimetric adaptation of a classical gravimetric procedure. This bulletin deals with the determination of phosphate in phosphoric acid and granular fertilizers such as MAP (monoammonium phosphate), DAP (diammonium phosphate) and TSP (triple superphosphate). Results are reported as percentage of P and P2O5.
- AN-D-001用于OpenLab CD的瑞士万通离子色谱驱动器
This application focuses on the simultaneous analysis of cations and suppressed anions with a dual channel Metrohm IC operated by OpenLab CDS.
- AN-D-002啤酒中的阴阳离子
- AN-D-003透析浓缩物的质量控制
离子色谱 (IC) 提供了一种自动、快速、灵敏的解决方案,可同时准确量化阳离子和阴离子成分(包括醋酸盐)。这种全面的方法使离子色谱成为血液透析浓缩液等药物溶液质量控制传统技术的经济替代方案。离子色谱 简单易用、准确度高、通量大,提高了生产效率,符合现代常规和研究实验室的要求。
- AN-H-008镁滴定法测定磷酸盐
可溶性正磷酸盐离子的测定,例如DAP等肥料中的磷酸盐。
- AN-H-035化肥中的磷酸盐 – 通过测温滴定法快速靠谱地测定
磷是植物的主要常量营养素,是 DNA 和三磷酸腺苷(ATP)的组成部分,参与许多需要能量的生物过程。在肥料中, 磷以磷酸盐的形式存在, 因为植物非常容易获得的磷形式是磷酸二氢盐。对磷含量的了解有助于为植物选择合适的肥料。传统上,磷酸盐是通过重量分析(耗时的程序)或分光光度法(昂贵的仪器)确定的。在本应用报告中,提出了一种替代方法,即通过镁沉淀滴定来确定磷酸盐。对磷含量在 6.5~17% 之间的各种固体和液体氮磷钾肥料进行了分析。测温滴定法分析液体氮磷钾肥料时不需要样品前处理,分析固体氮磷钾肥料时仅需要非常少的样品前处理。一个测定大约需要 5 分钟。
- AN-H-037酸性蚀刻混合剂中磷酸盐的测定
酸性蚀刻混合剂中磷酸盐含量的测定
- AN-M-003采用IC/MS联用法,用在线英蓝渗析技术进行样品处理,测定制备水中的磷酸根
采用电导检测和MS检测的阴离子色谱法,采用在线英蓝渗析,测定含高达100克/升氯离子及原油的制备水中的磷酸根。
- AN-N-006干燥处理的马铃薯中的氯离子,硝酸根,磷酸根,硫酸根与草酸根
采用阴离子色谱用直接电导检测法测定干燥处理的马铃薯中的氯离子,硝酸根,磷酸根,硫酸根与草酸根。
- AN-N-010植物叶子萃取液中的氯离子,硝酸根,磷酸根与硫酸根
采用阴离子色谱用直接电导检测法测定植物叶子萃取液中的氯离子,硝酸根,磷酸根与硫酸根。
- AN-N-015焦磷酸盐,三聚磷酸盐与三偏磷酸盐的测定
采用阴离子色谱用直接电导检测法测定焦磷酸盐,三聚磷酸盐与三偏磷酸盐。
- AN-N-046采用非抑制的离子色谱法测定fosetyl-aluminum
采用直接电导检测的阴离子色谱法测定fosetyl-aluminum (aluminium tris(O-ethylphosphonate)。
- AN-N-062输液中的乙酸根,磷酸根,氯离子与柠檬酸根。
采用直接电导检测的阴离子色谱法测定一种输液中的乙酸根,磷酸根,氯离子及柠檬酸根。
- AN-NIR-144近红外光谱法(NIRS)分析乳清渗透液
近红外光谱(NIRS)技术无需样品前处理,即可同步测定乳清渗透液中的关键质量参数(如灰分、磷酸盐、乳糖、蛋白质、pH值及水分含量)。
- AN-O-009使用Metrosep有机酸柱测定八种有机酸以及磷酸根。
采用离子排斥色谱,用直接电导检测法测定有机酸与磷酸根
- AN-PAN-1042核电站单次回路中阴离子的在线痕量分析
在核电站中,监测或防止腐蚀的措施至关重要,如果不对腐蚀加以控制,可能会对健康和安全造成重大威胁。阴离子会在高温高压下腐蚀金属,因此必须随时监测阴离子的浓度。单次回路中的分析难题是检测微克/升范围内的阴离子以及克级数量的硼酸和氢氧化锂。精确、可靠的痕量分析要求分析方法尽可能自动化。瑞士万通过程分析仪 的 2060 在线离子色谱仪一次进样可测量多种阴离子,并结合了在线预浓缩和在线基质消除功能,可一次又一次地精确、可靠地测量低浓度阴离子。
- AN-PAN-1046通过离子色谱仪(ASTM E1787-16)在线测定 50% NaOH 和 50% KOH 中的阴离子
基础化学工业负责大规模生产数千种原料。下游产业依靠一定程度的化学纯来制造自己的商品,因为某些杂质会导致各种工艺中出现重大问题。在生产碱性化学品 NaOH 和 KOH 的过程中,用膜电池电解饱和盐水溶液产生的产品进一步蒸发浓缩。在盐水中使用的盐杂质也将被浓缩。通常,使用各种有不同保质期的危险化学品离线进行此种杂质分析。过程离子色谱仪能够在线进行 ASTM E1787-16 中描述的测量,确保优质产品,而不需要耗时、危险的实验室实验。
- AN-Q-003在线监测锅炉给水中的微量阴离子含量
采用化学抑制后电导检测的阴离子色谱法测定锅炉进给水中微量的氯离子,硝酸根,磷酸根与硫酸根。
- AN-Q-006压水反应堆(PWR)硼化水中阴离子的在线痕量分析
压水反应堆(PWR)主回路中的水含有用于吸收中子的硼。较高的硼含量却会影响对阴离子直接进行痕量测定。英蓝中和配合可变浓缩和英蓝基质消除(MiPCT-ME)功能,可在进样前消除样品中的硼。
- AN-Q-007超临界水-蒸汽回路中氯化物和油酸盐的在线分析
850 Professional IC 和 872 Extension Module Liquid Handling 配合使用,开辟了万通在线离子色谱分析的新领域。本应用报告介绍英蓝浓缩和基质消除(MiPCT-ME)的组合使用方式。通过消除基质组分后,可以较高的灵敏度测定腐蚀性阴离子。此外,通过这种方法还可在使用单一校准溶液的情况下自动进行校准。可在线分析多条样品流的氯化物和硫酸盐含量。
- AN-Q-008采用离子色谱法监测蒸馏水痕量
940 Professional IC Vario、942 Extension Module Vario LQH 和 941 淋洗液制备模块组合使用,可实现采用离子色谱对工艺过程的监控。根据 ProfIC Vario 12 Anion 这一名称可知该组合为瑞士万通专业离子色谱装置的阴离子款型。采用基质消除的智能浓缩技术用于样品前处理。使用 ELGA PURELAB® Flex 6 可确保提供非常高质量的超纯水,尤其是在高样品通量的情况下。
- AN-RS-005利用拉曼光谱区分
本应用说明介绍了手持式拉曼光谱仪(如 Mira M-1)在识别和区分碳酸盐、磷酸盐和硫酸盐等盐类方面的适用性。工作重点是评定阳离子部分和结晶水对拉曼光谱鉴定盐类的影响。
- AN-RS-048Phosphates speciation with Raman spectroscopy
Metrohm’s MIRA XTR handheld Raman spectrometer enables fast, reagent-free identification of phosphate species, enabling continuous monitoring of dynamic systems.
- AN-RS-049Determining phosphate concentration with Raman spectroscopy
Raman spectroscopy with PLS modeling enables rapid, accurate, nondestructive quantification of the total phosphate content in solution with minimal sample preparation.
- AN-RS-054采用拉曼光谱技术实时监测磷酸盐反应过程
拉曼光谱技术作为一种快速检测方法,可用于溶液中的磷酸盐与硫酸盐物种分析,为优化磷肥生产工艺和提升产品质量提供支持。
- AN-S-005冷却水中的六种阴离子
采用化学抑制后电导检测的阴离子色谱法测定冷却水中的氟离子,氯离子,亚硝酸根,硝酸根,磷酸根与硫酸根。
- AN-S-006乙二醇中的次磷酸根,磷酸根,与有机酸
采用化学抑制后电导检测的阴离子色谱法测定乙二醇中的次磷酸根,甲酸根,磷酸根,己二酸根,对硝基苯甲酸根与癸二酸根。
- AN-S-007废水中的氯离子,硝酸根,磷酸根与硫酸根
采用化学抑制后电导检测的阴离子色谱法测定废水中的氯离子,硝酸根,磷酸根与硫酸根。
- AN-S-0112% 的氢氟酸中的磷酸根和四氟硼酸根
采用化学抑制后电导检测的阴离子色谱法测定2% HF中的磷酸根和四氟硼酸根。
- AN-S-023一种清洗溶液中的磷酸根和硫酸根
采用化学抑制后电导检测的阴离子色谱法测定一种清洗溶液中的磷酸根和硫酸根。
- AN-S-025一种刹车添加剂中的氯离子,溴离子,磷酸根与硫酸根
采用化学抑制后电导检测的阴离子色谱法测定灰化处理后的刹车添加剂中的氯离子,溴离子,磷酸根与硫酸根。
- AN-S-026磷酸根与亚磷酸根的分析
采用化学抑制后电导检测的阴离子色谱法分离氟离子,氯离子,亚硝酸根,溴离子,硝酸根,磷酸根,亚磷酸根,硫酸根与四氟硼酸根。
- AN-S-028ppb级别的阴离子。
采用化学抑制后电导检测的阴离子色谱法,直接进样测定1 (3) µg/L的氯离子,亚硝酸根,溴离子,硝酸根,磷酸根与硫酸根。
- AN-S-029蚀刻剂中的阴离子
采用化学抑制后电导检测的阴离子色谱法测定蚀刻剂中的氟离子,硝酸根,磷酸根与硫酸根。
- AN-S-033地表水中的五种阴离子(用ELCD检测亚硝酸根)
采用阴离子色谱,用化学抑制后电导检测法测定地表水中的氟离子,氯离子,硝酸根,磷酸根与硫酸根,用电化学检测法(电导与ELCD检测器串联)测定亚硝酸根。
- AN-S-038采用样品英蓝渗析处理法测定含高含量有机物的污水中的阴离子。
采用化学抑制后电导检测以及样品英蓝渗析处理的阴离子色谱法测定污水中的溴离子,硝酸根与磷酸根。
- AN-S-039采用英蓝渗析样品预处理法测定排污沟废水中的溴离子和磷酸根。
采用化学抑制后电导检测及英蓝渗析样品预处理的阴离子色谱法测定含非常高浓度的其它离子及有机物的排污沟废水中的溴离子和磷酸根。
- AN-S-040采用样品英蓝渗析处理法测定切割油乳浊液中的五种阴离子
采用化学抑制后电导检测以及样品英蓝渗析处理的阴离子色谱法测定切割油乳浊液中的氯离子,亚硝酸根,硝酸根,磷酸根与硫酸根。
- AN-S-053硼酸中的四种阴离子
采用化学抑制后电导检测的阴离子色谱法测定硼酸中的氟离子,氯离子,磷酸根与硫酸根。
- AN-S-059一种输液中的乙酸根,氯离子,磷酸根与琥珀酸根。
采用化学抑制后电导检测的阴离子色谱法测定一种输液中的乙酸根,氯离子,磷酸根与琥珀酸根。
- AN-S-063使用样品英蓝渗析处理法测定聚乙烯基膦酸中的磷酸根与亚磷酸根
采用化学抑制后电导检测以及样品英蓝渗析处理的阴离子色谱法测定聚膦酸中的磷酸根与亚磷酸根。
- AN-S-066经过预浓缩后,测定硼酸中的痕量阴离子
采用化学抑制后电导检测,并采用样品预浓缩的阴离子色谱法测定硼酸中的氟离子,氯离子,硝酸根,磷酸根与硫酸根。
- AN-S-068采用MSM进行在线样品中和,测定15% NaOH中的痕量阴离子
采用化学抑制后电导检测,并采用在线样品中和的阴离子色谱法测定15% NaOH中的痕量氟离子,氯离子,硝酸根,磷酸根与硫酸根。
- AN-S-075单氟磷酸谷氨酰胺中的五种阴离子
采用化学抑制后电导检测的阴离子色谱法测定单氟磷酸谷氨酰胺中的氟离子,氯离子,磷酸根与单氟磷酸根。
- AN-S-076废水中的六种阴离子
采用化学抑制后电导检测的阴离子色谱法测定废水中的氟离子,氯离子,硝酸根,亚硫酸根,磷酸根与硫酸根。
- AN-S-084一种染料溶液中的氯离子,磷酸根,亚磷酸根与硫酸根
采用化学抑制后电导检测的阴离子色谱法测定染料溶液中的氯离子,磷酸根,亚磷酸根与硫酸根。
- AN-S-090采用样品英蓝渗析处理法测定一种蛋白质配方中的四种阴离子。
采用化学抑制后电导检测以及样品英蓝渗析处理的阴离子色谱法测定蛋白质配方中的氯离子,硝酸根,磷酸根与硫酸根。
- AN-S-093一种阳离子电泳涂料槽液中的硝酸根,磷酸根,硫酸根与铬酸根。
采用化学抑制后电导检测的阴离子色谱法测定 阳离子电泳涂料槽液中的硝酸根,磷酸根,硫酸根与铬酸根。
- AN-S-100彩色液体中的九种阴离子
采用化学抑制后电导检测的阴离子色谱法测定彩色液体中的氟离子,氯离子,亚硝酸根,溴离子,硝酸根,磷酸根,亚硫酸根,硫酸根与硫代硫酸根。
- AN-S-107用Metrosep A Supp 3分离柱测定废水中的五种阴离子
采用化学抑制后电导检测的阴离子色谱法测定废水中的氟离子,氯离子,硝酸根,磷酸根与硫酸根。
- AN-S-108在线消除重金属后,对一种电镀槽液中的五种阴离子进行测定
采用阴离子色谱,用化学抑制后电导检测法,并采用793离子色谱样品处理模块上的阳离子交换法在线消除重金属后,对一种电镀槽液中的氯离子,亚硝酸根,硝酸根,磷酸根与硫酸根进行测定。
- AN-S-109用Metrosep A Supp 5分离柱测定Schoeniger吸收溶液中的六种阴离子
采用化学抑制后电导检测的阴离子色谱法测定Schoeniger吸收溶液中的氯离子,亚硝酸根,溴离子,硝酸根,磷酸根和硫酸根。
- AN-S-120牙膏中的氟化物、氯化物、磷酸盐、单氟磷酸盐和硫酸盐
通过阴离子色谱分析法、在化学抑制后以电导检测测定牙膏中的氟化物、氯化物、磷酸盐、单氟磷酸盐和硫酸盐。
- AN-S-123肉萃取液中的五种阴离子
采用化学抑制后电导检测的阴离子色谱法测定一种经过Carrez试剂澄清法处理的肉萃取液(Na2B4O7)中的氯离子,亚硝酸根,硝酸根,磷酸根与硫酸根。
- AN-S-126经过在线中和处理后,对NaOH中的五种阴离子进行测定
采用阴离子色谱,用化学抑制后电导检测法,并采用793离子色谱样品处理模块上的阳离子交换小柱进行在线中和后,对20%的NaOH中的氯离子,溴离子,硝酸根,磷酸根与硫酸根进行测定。
- AN-S-127人尿中的五种阴离子
采用化学抑制后电导检测以及样品英蓝渗析处理的阴离子色谱法测定人尿中的氯离子,硝酸根,磷酸根,硫酸根与草酸根。
- AN-S-129经过二硫酸盐消解处理后的废水中的磷酸根总含量
采用化学抑制后电导检测的阴离子色谱法测定经过二硫酸盐消解处理后的废水中的磷酸根总含量。
- AN-S-135河水中的八种阴离子
采用化学抑制后电导检测的阴离子色谱法测定河水中的氟离子,氯离子,亚硝酸根,溴离子,硝酸根,磷酸根,亚硫酸根与硫酸根。
- AN-S-138聚磷酸根以及标准阴离子
采用高压梯度以及化学抑制后电导检测的阴离子色谱法测定焦磷酸根,三偏磷酸根,三聚磷酸根,以及氟离子,氯离子,亚硝酸根,溴离子,硝酸根,磷酸根和硫酸根。
- AN-S-141饮料中的氯离子,硝酸根,磷酸根,硫酸根和柠檬酸根。
采用高压梯度以及化学抑制后电导检测的阴离子色谱法测定饮料中的氯离子,硝酸根,磷酸根,硫酸根和柠檬酸根。
- AN-S-142一种粘土萃取液中的硅酸根,硫酸根与磷酸根
采用化学抑制后电导检测的阴离子色谱法测定粘土萃取液中的硅酸根,硫酸根和磷酸根。 采用台阶梯度,以及阀切换,以便在化学抑制或非化学抑制的情况下进行测试。
- AN-S-143氨基酸中的甘油磷酸
采用化学抑制后电导检测的阴离子色谱法测定氨基酸中的α-甘油磷酸与β-甘油磷酸。
- AN-S-144一种涤气塔溶液中的热稳定性盐
采用化学抑制后电导检测的阴离子色谱法测定涤气塔溶液中的氯离子,溴离子,硝酸根,亚硫酸根,硫酸根,磷酸根,草酸根,硫代硫酸根与硫氰酸根(热稳定性盐)。
- AN-S-148焦磷酸四钠中的阴离子
采用高压梯度以及化学抑制后电导检测的阴离子色谱法测定焦磷酸四钠中的氟离子,氯离子,硝酸根,磷酸根,硫酸根,三偏磷酸根和三聚磷酸根。
- AN-S-149三聚磷酸盐中的阴离子
采用高压梯度以及化学抑制后电导检测的阴离子色谱法测定三聚磷酸盐中的氯离子,亚硝酸根,硝酸根,磷酸根,硫酸根,三偏磷酸根和焦磷酸根。
- AN-S-150三聚磷酸钠中的正磷酸根,焦磷酸根与三偏磷酸根(等度洗脱)
采用化学抑制后电导检测的阴离子色谱法测定三聚磷酸钠中的正磷酸根,焦磷酸根与三偏磷酸根。
- AN-S-151清洗液中的阴离子。
采用电导检测与化学抑制的阴离子色谱法测定一种酸性清洗液中的溴乙酸根,甲基磺酸根,氯离子,磷酸根以及硫酸根。
- AN-S-154采用高压梯度淋洗法测定11种阴离子
采用高压梯度以及化学抑制后电导检测的阴离子色谱法测定一种标准溶液中的氟离子,氯离子,亚硝酸根,溴离子,硝酸根,磷酸根,硫酸根,草酸根,硫代硫酸根,碘离子和柠檬酸根。
- AN-S-160一种离子性液体中的六氟磷酸根
采用化学抑制后电导检测的阴离子色谱法测定一种离子性液体BMIHFP(1-butyl-3-methylimidazolium hexafluorophosphate,>97%)中的六氟磷酸根。
- AN-S-164橙汁中的五种阴离子
采用化学抑制后的电导检测以及样品在线英蓝渗析处理的阴离子色谱法测定橙汁中的乳酸根,甲酸根,氯离子,磷酸根和硫酸根。
- AN-S-165一种电镀槽液中的次磷酸根,亚磷酸根,酒石酸根,钨酸根,磷酸根,柠檬酸根与焦磷酸根
采用高压梯度以及化学抑制后电导检测的阴离子色谱法测定一种电镀槽液中的次磷酸根,亚磷酸根,酒石酸根,钨酸根,磷酸根,柠檬酸根与焦磷酸根。
- AN-S-171一种食品添加剂中的柠檬酸根和聚合磷酸根
采用化学抑制后电导检测的阴离子色谱法测定一种食品添加剂中的柠檬酸根,二聚磷酸根和三聚磷酸根。
- AN-S-180清洗粉中的硫酸根,柠檬酸根与磷酸根
采用化学抑制后电导检测的阴离子色谱法测定一种清洗粉中的硫酸根,磷酸根,柠檬酸根,焦磷酸根,三偏磷酸根与三聚磷酸根。
- AN-S-183用于离子色谱的万思得在线英蓝渗析装置
采用化学抑制后的电导检测的阴离子色谱以及万思得英蓝渗析法进行在线样品处理对蛋黄酱中的乙酸根,氯离子,硝酸根,磷酸根和硫酸根进行测定。
- AN-S-186使用在线基体消除法测定含N-甲基吡咯烷酮的污水中的阴离子。
采用化学抑制后电导检测以及在线基体消除的阴离子色谱测定含N-甲基吡咯烷酮的污水中的氟离子,乙酸根,甲酸根,氯离子,亚硝酸根,硝酸根,磷酸根和硫酸根。
- AN-S-187矿泉水中的碘离子及标准阴离子
采用化学抑制后电导检测的阴离子色谱法测定一种矿泉水中的氟离子,氯离子,亚硝酸根,溴离子,硝酸根,磷酸根,硫酸根与碘离子。
- AN-S-190一种含70 g/L钒酸根的强碱性溶液中的五种阴离子
采用化学抑制后电导检测的阴离子色谱法测定一种强碱性溶液中的氯离子,亚硝酸根,硝酸根,磷酸根与硫酸根。
- AN-S-192采用在线稀释法在线测定一种腐蚀槽液中的酸
采用化学抑制后电导检测的阴离子色谱法测定一种蚀刻槽液中的氟离子,硝酸根,磷酸根,亚硫酸根与硫酸根。
- AN-S-193啤酒麦芽汁中的四种阴离子
采用化学抑制后电导检测的阴离子色谱法测定啤酒麦芽汁中的氟离子,氯离子,磷酸根与硫酸根。
- AN-S-195高压梯度分离阴离子与有机酸。
采用化学抑制后电导检测及高压梯度的阴离子色谱法测定21种阴离子与有机酸。
- AN-S-196农渠水中的阴离子
采用化学抑制后电导检测的阴离子色谱法测定雨水中的农渠水中的氟离子,氯离子,亚硝酸根,溴离子,硝酸根,磷酸根与硫酸根。
- AN-S-199亚硒酸根与硒酸根,以及标准阴离子
采用化学抑制后电导检测的阴离子色谱法测定氟离子,氯离子,亚硝酸根,亚硒酸根,磷酸根,硝酸根,硫酸根与硒酸根。
- AN-S-201用Metrosep A Supp 1分离柱对八种阴离子进行分离
采用化学抑制后电导检测的阴离子色谱法测定甲酸根,氯离子,亚硝酸根,亚磷酸根,磷酸根,亚硫酸根,硝酸根与硫酸根。
- AN-S-206锅炉给水痕量阴离子在线监测系统
采用化学抑制后电导检测的阴离子色谱法测定锅炉进给水中痕量的氯离子,硝酸根,磷酸根与硫酸根。
- AN-S-207液体化肥中的硝酸根与磷酸根
采用化学抑制后电导检测的阴离子色谱法测定一种液态化肥中的硝酸根和磷酸根。
- AN-S-212泡腾片中的氟磷酸根
采用化学抑制后电导检测的阴离子色谱法测定泡腾片中的氟磷酸根,采用台阶梯度淋洗出强保留组分。
- AN-S-215定性分析尿中的阴离子,以确认掺假
采用化学抑制后电导检测的阴离子色谱法,定性分析尿中的氯离子,磷酸根与硫酸根以及亚氯酸根,亚硝酸根,氯酸根,溴离子与铬酸根。
- AN-S-219引擎冷却剂中阴离子与有机酸
采用化学抑制后电导检测的阴离子色谱法测定引擎冷却剂中的乙醇酸根,甲酸根,氯离子,亚硝酸根,硝酸根,磷酸根,硫酸根和草酸根。
- AN-S-221人尿和老鼠尿中的硫酸根,磷酸根与焦磷酸根
采用化学抑制后电导检测的阴离子色谱法测定人尿和老鼠尿中的硫酸根,磷酸根与焦磷酸根。
- AN-S-222硼酸盐废水中的阴离子
采用化学抑制后电导检测的阴离子色谱法测定一种硼酸盐废水中的氟离子,氯离子,硝酸根,磷酸根与硫酸根。
- AN-S-225采用Metrosep A Supp 10 - 100/4.0分析柱测定啤酒中的亚硫酸根及标准阴离子
采用化学抑制后电导检测的阴离子色谱法测定一种啤酒中的氯离子,磷酸根,亚硫酸根,溴离子,硝酸根与硫酸根。
- AN-S-227二甲基乙酰胺中的阴离子
采用化学抑制后电导检测的阴离子色谱法测定二甲基乙酰胺中的氯离子,溴离子,硝酸根,磷酸根与硫酸根。
- AN-S-230经过在线稀释和在线英蓝渗析处理后的聚合物样品中的磷酸根与硫酸根
采用化学抑制后电导检测的阴离子色谱法测定一种液态聚合物样品中的磷酸根和硫酸根。
- AN-S-236基于EPA 300.1方法的饮用水水质分析
一次离子色谱运行即可完成EPA 300.1方法A部分与B部分分析,饮用水检测快速可靠。
- AN-S-237工艺用水(process water)中的磷组分
采用抑制电导检测的阴离子色谱法测定含氟离子、氯离子与硫酸根的工艺用水(process water)中的次磷酸根,亚磷酸根与磷酸根。
- AN-S-247镍镀槽磷系添加剂监测平台 (次磷酸盐-亚磷酸盐-磷酸盐联测 · 抗强酸腐蚀设计 )
采用化学抑制后电导检测的阴离子色谱法,应用在线阳离子交换处理,测定镍槽液中的次磷酸根,亚磷酸根与磷酸根。
- AN-S-249一种工艺用水(process water)中的14种阴离子
使用电导检测阴离子色谱法并采用串联抑制,测定一种工艺用水(process water)中的氟离子,乙酸根,丙酸根,甲酸根,丁酸根,氯离子,亚硝酸根,溴离子,硝酸根,苯甲酸根,磷酸根,硫酸根,丙二酸根与草酸根。
- AN-S-250氢氧化四甲基铵(TMAOH)中的痕量阴离子
采用串联抑制后电导检测及在线基体中和的阴离子色谱法测定20% TMAOH中的甲酸根,氯离子,硝酸根,磷酸根与硫酸根。
- AN-S-254MISP – 瑞士万通英蓝超滤 – 交叉污染 < 0.1%
采用在线英蓝超滤及化学抑制后电导检测的阴离子色谱法测定100毫克/升的氟离子,氯离子,亚硝酸根,溴离子,硝酸根,磷酸根与硫酸根对超纯水的交叉污染。
- AN-S-255采用梯度淋洗、 Metrosep A Supp 7 - 250/4.0 色谱柱分离16种阴离子
利用阴离子色谱电导检测器、梯度淋洗和化学抑制的方法测定氟化物、次磷酸盐、亚氯酸盐、溴酸盐、氯化物、亚硝酸盐、溴化物、氯酸盐、硝酸盐、亚磷酸盐、磷酸盐、硫酸盐、砷酸盐、碘化物、铬酸盐和高氯酸盐。
- AN-S-259采用 Metrosep A Supp 15 - 100/4.0 色谱柱进行磷酸根和柠檬酸根的分离
利用阴离子色谱电导检测器和化学抑制的方法测定硫酸根、磷酸根和柠檬酸根。
- AN-S-267E85 混合物(85% 乙醇和 15% 汽油)中的阴离子,借助英蓝基体消除
借助阴离子色谱、使用电导测量和序列抑制法测定 E85 混合物(85% 乙醇和 15% 汽油)中的氟化物、醋酸、甲酸、氯化物、亚硝酸盐、硝酸盐、磷酸盐和硫酸盐。进行样品准备时采用英蓝基体消除。
- AN-S-269MiPT - 瑞士万通智能部分循环进样技术
使用智能部分循环进样技术校准氟化物、氯化物、亚硝酸盐、溴化物、硝酸盐、磷酸盐和硫酸盐,采用阴离子色谱法,在连续抑制后进行电导检测。该技术允许在 1 个校准溶液中实现 1:100 的校准范围(例如,1 μg/L 至 100 μg/L 相当于 2 μL 至 200 μL 的注入体积)。对样品进行全范围的部分循环进样,一次校准的样品浓度范围为 1 至 10'000。
- AN-S-270进样过滤器中的杂质 - 阴离子
使用阴离子色谱法测定进样器过滤器中的氟化物、醋酸盐、甲酸盐、氯化物、亚硝酸盐、硝酸盐、磷酸盐和硫酸盐杂质,并在顺序抑制后进行电导检测。
- AN-S-271Fosetyl-aluminum in pesticide formulations
Determination of fosetyl-aluminum in a formulation using anion chromatography with conductivity detection after sequential suppression.
- AN-S-272Column-switching method for anions in water samples with two different analytical requirements
Determination of fluoride, chloride, nitrate, phosphate, and sulfate on a short column or the ions mentioned plus bromate and nitrite on a long column in water samples applying intelligent column-switching using anion chromatography with conductivity detection after sequential suppression.
- AN-S-274Anions in cooling lubricant after inline dialysis
Determination of chloride, nitrite, bromide, nitrate, phosphate, sulfite, sulfate, and oxalate in a cooling lubricant using anion chromatography with conductivity detection and subsequent UV detection (see AN-U-047) after sequential suppression applying Metrohm Inline Dialysis.
- AN-S-278Anions in sodium tetraborate with Metrohm Inline Acidification, Metrohm Inline Matrix Elimination, and Metrohm Inline Calibration
Determination of fluoride, chloride, phosphate, and sulfate in sodium tetraborate using anion chromatography with conductivity detection after sequential suppression. Inline acidification is applied to convert tetraborate into boric acid which is not retained on the preconcentration column. Inline calibration minimizes the anion contamination.
- AN-S-280Ten anions in an offshore effluent
Determination of acetate, chloride, nitrite, bromide, nitrate, phosphate, sulfate, oxalate, fumarate, and molybdate using anion chromatography with conductivity detection after chemical suppression.
- AN-S-282Phosphor anions in a biocide
Determination of phosphate, HEDP (etidronic acid), and pyrophosphate in a biocide sample using anion chromatography with conductivity detection after sequential suppression.
- AN-S-291瑞士万通抑制器模块 (MSM) 的可重复性
非常先进的三室抑制器技术为每次测量提供一个全新的抑制室。色谱图和统计数据表明,使用瑞士万通抑制器模块进行的测量具有非常好的重现性。
- AN-S-293使用带有 MSM-HC 抑制器的阴离子色谱法分析洗衣粉中的阴离子
大容量抑制器 MSM-HC 可在高浓度洗脱液(如氢氧化钠洗脱液)条件下进行分析。洗衣粉中阴离子的测定就是一个典型的例子,需要使用高 pH 值的 NaOH 来分离多磷酸盐。
- AN-S-294美白牙膏中的磷酸盐种类
美白牙膏通常含有多磷酸盐来去除污渍。分析这些多磷酸盐需要使用高 pH 的氢氧化物洗脱液。大容量抑制器 MSM-HC 可抑制洗脱液的高浓度。
- AN-S-295锅炉水中的阴离子,包括硫样本(亚硫酸盐和硫酸盐)
锅炉水分析是电厂应用中的一项重要任务。在给定的条件下,“Metrosep A Supp 10 - 100/4.0 ”色谱柱可以分离亚硫酸盐和硫酸盐,而无需在淋洗液中添加任何有机改性剂。即使不使用任何稳定剂,亚硫酸盐的测定结果也具有很高的重现性。
- AN-S-296用849液位控制器进行阴离子在线淋洗液制备
按需淋洗液制备 (EPOD) 是一种方便灵活的自动淋洗液制备方法。849 液位控制器与配备 50 mL 定量装置的 800 Dosino 一起使用,可将浓缩淋洗液稀释到终淋洗液浓度。浓缩淋洗液适用于任何类型的淋洗液。这便于系统在无人看管的情况下运行数周(阳离子淋洗液的制备参见 AN C-134)。
- AN-S-301Comprehensive water analysis with VoltIC pro I
VoltIC pro I is the perfect combination of voltammetry and ion chromatography for the fully automated analysis of anions, cations, and heavy metals (e.g., Zn, Cd, Pb, Cu): comprehensive water analysis on a single system.
- AN-S-304Variable Inline Preconcentration including Matrix Elimination for trace anion analysis (MiPCT-ME)
Metrohm Inline Preconcentration Technique with Matrix Elimination (MiPCT-ME) is a powerful tool that combines preconcentration, matrix elimination, and multilevel calibration. The latter only requires a single multi-ion standard solution. The 800 Dosino takes over all liquid handling tasks. The shown system setup allows sample analysis from 0.1 µg/L up to 1.0 mg/L.
- AN-S-307可乐饮料中的磷酸盐
可乐饮料中含有高浓度磷酸。测定磷酸含量属于可乐饮料质量检查的一部分。也可以在加工过程中通过磷酸盐分析监控磷酸盐浓度稀释。尽可能稀释浓度对于装瓶方也有着经济益处。
- AN-S-30970% 过氧化氢中的阴离子使用英蓝基质清除
过氧化氢被用作清洁剂、氧化剂和漂白剂。取决于纯度,它可含有无机阴离子和有机酸阴离子,如草酸和邻苯二甲酸酯,以及吡啶二羧酸。吡啶二羧酸络合试剂将过渡金属阳离子络合,有时加入过氧化氢以提高其稳定性。
- AN-S-314借助 Dose-in 剂量梯度测定虾中的正磷酸盐、焦磷酸钠、三聚磷酸钠和三聚磷酸钠
正磷酸盐和多磷酸盐的测定是虾的重要质量检查。剂量梯度通过加配更强的淋洗液,能加快阴离子分离。磷酸盐的分离造成在氢氧化物含量保持不变的情况下碳酸浓度增加。
- AN-S-317印刷电路板表面阴离子残留分析平台
电子产品制造过程中不可忽视清洁。尤其是离子性污染会导致电路板质量急剧恶化。本 Application Note 将介绍电路板表面阴离子的测定。为此所使用的方法-智能 Partial Loop(局部循环)进样工艺(MiPT)-可在同一样品中测定阳离子和阴离子。阳离子的测定在 AN-C-149 中进行了描述。
- AN-S-318快速离子色谱分析:三分钟分离标准阴离子
快速离子色谱分析意味着高度的样品通量。通过较短色谱柱、相对较高的流量以及较强的淋洗液来实现。可于三分钟之内在 Metrosep A Supp 10 - 50/4.0 上测定标准阴离子。
- AN-S-322快速离子色谱分析:八分钟内测定标准阴离子和草酸。
快速离子色谱分析意味着运行时间短且样品通量高。将通过较短色谱柱和较强淋洗液来实现。可于八分钟之内在 Metrosep A Supp 5 - 100/4.0 上分离氟化物、氯化物、硝酸盐、磷酸盐、硫酸盐和草酸盐。
- AN-S-326在游泳池水中测定标准阴离子之外的氧卤化物
游泳池水须彻底消毒,此过程通常使用臭氧完成。此时可能会产生有害的氧卤化物,须监测其浓度。分离和测定标准阴离子之外的氧氯化物的过程在色谱柱 Metrosep A Supp 5 - 250/4.0 上完成。然后可按照序列抑制法通过电导监测来进行定量。
- AN-S-327在饮料分析中通过梯度缩短柠檬酸保留时间
在含有柠檬酸的饮料中,柠檬酸的较长停留时间会使色谱法测定阴离子的过程延迟。使用梯度方法可减少柠檬酸停留时间,由此明显缩短分析时间。
- AN-S-331使用微孔阴离子柱 Metrosep A Supp 5 分离七种标准阴离子
微孔阴离子柱 Metrosep A Supp 5 有 150 和 250 mm 两种款型。7 种标准阴离子的分离时间分别为 20 和 29 分钟。除了良好的分离性能和运行时间短之外,微孔分离柱所消耗的淋洗液比 4 mm 款型减少 75%。
- AN-S-332使用英蓝超滤和英蓝淋洗液制备的 Metrosep A Supp 5 - 250/2.0 色谱柱稳定性
微孔款型 Metrosep A Supp 5 - 250/2.0 的色谱柱稳定性已由长期的实验室操作检测而得到验证。连续六天进行 2 套进样系列。每套系列均包括 9 次自来水、3 次检查标准溶液和 6 次自来水进样。第七天关闭离子色谱仪系统。该离子色谱仪系统一共运行 12周,共计 2650 次进样。其结果表明了具有良好的重现性和高度柱稳定性。
- AN-S-335使用英蓝超滤和英蓝淋洗液制备的 Metrosep A Supp 5 - 250/4.0 色谱柱稳定性
经长期实验室测试业已证实 Metrosep A Supp 5 - 250/4.0 色谱柱的稳定性。曾连续六天每天运行 2 套进样系列流程。 每套系列流程均包括 9 次自来水进样、3 次检验标准溶液进样和 6 次自来水进样。每到第七天均关闭离子色谱仪系统。该离子色谱系统一共运行超过 10 周,共计进行了 2150 次进样。其结果显示出良好的重现性,以及高度的色谱柱稳定性。
- AN-S-344高容量色谱柱上«电子级»硝酸淋洗液中的阴离子
电子级硝酸 (electronic grade) 仅可含有微量阴离子污染(mg/L-范围)。只有在所有其他离子从色谱柱淋洗出之后,这些阴离子痕量的离子色谱法测定既需要高容量色谱柱,也需要硝酸盐淋洗液。借助强碳酸盐/碳酸氢钠淋洗液,可在 Metrosep A Supp 16 - 250/4.0 型色谱柱上实现分离。
- AN-S-345制药配方中的 β-甘油和 L-苹果酸
β-甘油和 L-苹果酸在制药配方中进行测定。借助碳酸盐淋洗液和 Metrosep A Supp 7 - 250/4.0 色谱柱可从 α-甘油和磷酸盐中完美分离 β-甘油和苹果酸。
- AN-S-347使用 VoltIC Professional 1 全面分析水
VoltIC Professional 1 是伏安测量和离子色谱的非常好的结合,用于全自动同时分析阳离子、阴离子和重金属(比如锌、镉、铅、铜)。多参数分析法使用相同的<>元件和共同的自动进样器,可以节省空间和成本。
- AN-S-35230% 过氧化氢(H2O2)中焦磷酸盐和标准阴离子的测定
焦磷酸盐用作双氧水水溶液稳定剂。“试剂级”溶液可能有较高含量(mg/L)的焦磷酸盐,而“电子级”过氧化氢则应该不含此稳定剂。在此,结合运用英蓝富集和基质消除(MiPCT-ME)以及剂量梯度分析,测定高纯度 H2O2 溶液(30%)中的焦磷酸盐含量。
- AN-S-353常规饮用水分析
离子色谱法(IC)是确定水中常见离子浓度的首选方法。离子浓度是饮用水中非常重要的指标 ,必须 符合相关标准要求才能保证安全 (如亚硝酸盐和硝酸盐)。此外工业上的一些技术要求也对水中离子浓度做了限制(如氯离子和硫酸盐的腐蚀性)。 Eco IC智能离子色谱系统经济实惠,非常适合用于常规水分析。Eco IC标配为电导检测器和化学抑制器,可选配全自动样品前处理装置。化学抑制器可以大大减少基线背景,提高信噪比,拓宽检测范围,降低检出限。配备A Supp 17阴离子色谱柱,在室温下即可对饮用水中主要阴离子进行分析,无需外配柱温箱。
- AN-S-354使用 Eco IC 测定废水中的阴离子
Eco IC 是一种入门级设备,特别适于常规运行和水分析。它配备有电导检测器,可以在使用或不使用化学抑制的情况下使用。本Application Note描述了使用色谱柱 Metrosep A Supp 17 - 250/4.0 测定阴离子含量的方法。这种色谱柱型号特别适用于在室温下分析水。
- AN-S-355牙膏中单氟磷酸盐的测定
单氟磷酸盐用于牙膏中以预防龋齿。美国食品药物管理局(USFDA)允许成人及 6 岁以上儿童使用的非处方(OTC)牙粉中氟化物最大含量为 1.5 g/kg,对应的单氟磷酸钠最大含量为 11.5 g/kg。在此,在执行化学抑制后应用电导检测技术,通过离子色谱分析牙膏中的单氟磷酸盐含量。
- AN-S-356天然气制乙二醇中的无机阴离子
乙二醇用于在液化之前先对天然气进行脱水处理,并且需要定期检查其纯度。无机阴离子及其相应的酸具有腐蚀性,因此必须将其保持在最低水平。分离使用微孔 Metrosep A Supp 16 - 250/2.0 色谱柱执行,并在执行序列抑制法后通过电导检测进行定量。
- AN-S-357污水处理厂的污水:用 Metrosep A Supp 4 - 250/2.0 进行阴离子测定
微内径 Metrosep A Supp 4 - 250/2.0 色谱柱特别适合用于分析危险样品的阴离子。在当前应用中分析的是废水样品。该样品在 Metrosep A Supp 4 - 250/2.0 上进样之前,仅需一次过滤。阴离子在使用电导检测法的情况下,经过连续抑制之后进行量化。
- AN-S-364水中溶解的阴离子根据 EN ISO 10304-1 施加英蓝超滤
EN ISO 10304-1 是测定水样中七种标准阴离子的非常重要标准之一。如果需要通过 IC 进行阴离子测定,请参考 EN ISO 10304-01 的许多其他标准。如果需要,本标准要求对样品进行膜过滤,以避免细菌和固体。此应用程序显示了根据 EN ISO 10304-1 应用英蓝超滤测定阴离子的方法。这种设置避免了繁琐的手动样品过滤,并全自动处理任何样品。
- AN-S-365浓缩电子级氢氧化铵中的阴离子杂质。
半导体行业需要超纯化学品。离子杂质可能会导致产品受损。本应用程序描述了电子级 28% 氢氧化铵溶液中阴离子杂质的测定方法。为了避免基质干扰,需要采用英蓝中和和英蓝预浓缩清除基质。
- AN-S-368STREAM – MSM 冲洗的完美方法 – 即使在基质中加入铁和铝
STREAM(测量后重复使用洗脱液处理抑制器)已经使用了相当长的一段时间。 与超纯水冲洗相比,用抑制型洗脱液进行抑制器冲洗是有利的:水浸更小、MSM 平衡更快以及可避免额外供水仅是众多优点中的几个例子。在硫酸再生的情况下,向基质中注入含铁的样品可使磷酸盐的峰更宽、面积减小。转换为基于硫酸和草酸的再生液可以使 MSM 可再生。上面的叠加图显示了向单个MSM室中进样 10mg/L Fe(||) 超过 300 次后采集到的三个色谱图。没有观察到峰形或峰面积的差异。
- AN-S-369使用抑制电导检测分析帕米膦酸盐中的亚磷酸盐和磷酸盐含量
帕米膦酸盐用于通过强化骨骼来治疗骨质疏松症。它是一种含有伯胺基团的双膦酸盐。亚磷酸盐和磷酸盐是相关的化合物,需要进行定量。USP 要求使用甲酸洗脱液,并进行折射率检测。但标准 IC 程序可作为替代方案,具有更好的灵敏度。在序列抑制后用电导检测来分析亚磷酸盐和磷酸盐。
- AN-S-371使用电导法检测水中的溴酸盐:优化分离和 LOQ
水中消毒副产物的测定是离子色谱法的标准应用。采用电导检测法从氯化物中分离出亚氯酸盐和溴酸盐对 μg/L 的指示极限是至关重要的。结合使用 Metrosep A Supp 7 - 250/4.0 分离柱和 Metrosep A Supp 16 Guard/4.0 保护柱可以优化分离效果。溴酸盐的定量极限约为 1μg/L。
- AN-S-372用离子色谱法分析锂离子电池电解液
锂离子(Li-ion)电池电解液的质量对性能、稳定性和安全性至关重要。离子色谱法是一种准确的电解液分析方法。
- AN-S-382用于 OpenLab CDS 的瑞士万通离子色谱Driver:软饮料中的阴离子和阳离子分析
OpenLab CDS 是安捷伦新一代的色谱数据系统,将色谱和质谱结合在一个软件平台中。用于 OpenLab CDS 的瑞士万通 IC Driver 集成了瑞士万通离子色谱仪器,可进行全控制和数据采集。本应用描述了利用双通道离子色谱系统同时分析软饮料中的阴离子和阳离子。通过应用 Inline Eluent Production 制备淋洗液。
- AN-S-383用于 OpenLab CDS 的瑞士万通 IC Driver:用 Dose-in Gradient 和 Dosino Regeneration 测定阴离子
OpenLab CDS 是安捷伦新一代的色谱数据系统。用于 OpenLab CDS 的瑞士万通 IC Driver 1.0 实现了瑞士万通离子色谱仪集成在 OpenLab CDS 中,从而可进行全控制和数据采集。此应用显示了在 OpenLab CDS 中使用梯度系统 (Dose-in Gradient) 和 Dosino Regeneration。分离并测定标准溶液中的氟离子、氯离子,亚硝酸根、溴离子、硝酸根,硫酸根、磷酸根和碘离子。
- AN-S-388根据 USP <345> 进行柠檬酸/柠檬酸盐和磷酸盐的含量测定
在 USP 色谱柱等效性测试过程中,根据 USP 通则<345>,将 Metrosep A Supp 3-250 / 4.0 用于柠檬酸/柠檬酸盐和磷酸盐的含量测定。该报告显示,Metrosep A Supp 3-250 / 4.0 色谱柱等效于 USP 通则 <345> 中要求的填料 L61。
- AN-S-389气体脱硫用单乙醇胺(MEA)中的热稳定盐
在石化工业中,天然气需要经过处理以去除污染物并符合产品规格。进程污染物包括硫化氢和二氧化碳等酸性气体,它们会腐蚀下游昂贵的炼油设备。通常,会使用单乙醇胺(MEA)或甲基二乙醇胺(MDEA)通过烷醇胺处理去除酸性气体。胺溶液会吸收酸性气体,然后从天然气中除去胺化合物。除酸性气体外,天然气中残留的热稳定盐(HSS)对处理厂也有腐蚀性。这些物质也会通过气体脱臭去除,并需要在使用后的气体脱臭胺溶液中进行测定。一些常见的热稳定盐包括乙酸盐(1)、甲酸盐(2)、氯化物(3)、磷酸盐(4)、硫酸盐(5)、草酸盐(6)、硫代硫酸盐(7)和硫氰酸盐(8)。
- AN-S-391采用先进的英蓝基质消除法消除柴油中的阴离子
柴油中的阴离子,特别是生物柴油,可能会在发动机中造成有害沉积物。离子色谱法测定需要将柴油阴离子转移到水溶液中,然后注入 IC。将阴离子转移到水中的一种常用方法是在注射前通过英蓝萃取并随后进行英蓝渗析(有关阳离子的相应分析,请见 AN-C-101)。在实际的基质消除方法中,用异丙醇稀释的柴油被注入异丙醇流中并穿过浓缩柱。异丙醇会洗掉柴油,并随后使用超纯水进行冲洗,去除多余的异丙醇。
- AN-S-393过氧化氢和氢氧化铵中的阴离子
半导体工业需要高纯度甚至超高纯度的化学品来生产电子元件。化学品的纯度对零件的质量和生产效率至关重要。在这里,过氧化氢和氢氧化铵的分析采用了传统的样品制备方法,如消化和蒸发,然后用超纯水重组。所获得的样本,采用了智能浓缩技术(MiPCT)进行注射。
- AN-S-395用集成电路进行法医检查分析
法医机构通过对使用过的爆炸物及其残留物进行痕量检测分析来检查恐怖袭击和战争制剂。特别重要的是为刑事调查部门和政府安全机构获取 "化学指纹"。使用抑制电导检测离子色谱法(IC)进行法医调查,可在广泛的浓度范围内灵敏、可靠地测定阴离子污染物,如氯酸盐、硫代硫酸盐、硫氰酸盐和高氯酸盐,以及常见的无机阴离子。
- AN-S-396用离子色谱评估葡萄酒质量
监测葡萄酒中的有机酸含量对改善葡萄酒风味和质量以及满足《国际酿酒规范》等通用标准化标准至关重要。在分析上,有机酸可以通过离子色谱法(IC)和抑制电导检测法进行测定。作为一种多组分方法,无机酸也可以被分辨出来,它们也是葡萄酒质量和口感的重要示踪剂。 本应用说明介绍了两种用于葡萄酒质量分析的离子色谱法:一种是主要有机酸和阴离子(包括亚硫酸盐)的快速等度筛选法,另一种是采用二元梯度分离 15 种有机酸的复杂监测法。在线超滤用于经济的样品处理。
- AN-S-398Phosphate in sodium and potassium phosphates compounded injections
An ion chromatography (IC) assay with suppressed conductivity detection is the standardized way to accurately quantify phosphate in phosphates compounded injections.
- AN-S-403锂离子电池溶剂中的阴离子
N 甲基吡咯烷酮 (NMP) 对锂离子电池的生产至关重要。瑞士万通的智能预浓缩技术具有基体消除功能,可对 NMP 中的阴离子进行 µg/L 级别的分析。
- AN-S-404根据 EPA 300.1 进行水质检测
Metrosep A Supp 21色谱柱和948连续离子色谱模块(CEP)能够高效、自动化地进行水中主要阴离子和消毒副产物的单次运行分析。
- AN-T-045灌输溶液中的醋酸盐、氯化物和磷酸盐
把阴离子转变为相应的酸后,使用氢氧化钠采用电位滴定法测定浸出液中的醋酸根、氯离子和磷酸根。
- AN-T-233通过滴定法测定焦磷酸盐
滴定法是一种准确而精确的方法,可用于测定水溶液中焦磷酸盐的含量。配备滴定管的 OMNIS 奥秘一代全自动电位滴定仪可进行可靠的测定。
- AN-U-008采用化学抑制后电导检测及其后UV/VIS检测的阴离子色谱法测定氯化镁(MgCl2)中的痕量阴离子。
采用化学抑制后电导检测及其后UV/VIS检测的阴离子色谱法测定痕量的氟离子,溴离子,硝酸根,磷酸根与硫酸根。
- AN-U-010一个虾养殖场的海水中的亚硝酸根,硝酸根与磷酸根
采用化学抑制后电导检测并在其后串接UV/VIS检测器进行检测的阴离子色谱法测定一个虾养殖场的海水中的亚硝酸根,硝酸根与磷酸根。
- EB-003用于食品和饮料分析的离子色谱法
利用离子色谱 (IC) 效率高的分析食品。了解其在饮料、食品添加剂和乳制品质量控制方面的非常大的应用。
- WP-009根据 US EPA 方法 300 确定自来水中的阴离子
本文说明了一种根据 US EPA 方法 300 A 部分确定七种标准阴离子(氟化物、氯化物、亚硝酸盐、溴化物、硝酸盐、磷酸盐和硫酸盐)的简便方法。为了进行分析,扩展了一套使用英蓝超滤和英蓝洗脱液生产的离子色谱仪 系统。
- WP-045当 HPLC 失效时:在食品、水和药物分析中使用 IC
高效液相色谱(HPLC)和离子色谱(IC)通常用于制药、食品和环境部门,用于分析样品中的特定组分,并验证是否符合规范和标准。然而,HPLC 的使用者可能会遇到该技术的一些局限性(例如,分析标准阴离子或某些药物杂质时)。本白皮书概述了如何通过 IC 克服这些挑战。
- WP-060肥料中的多参数分析:通过测温滴定法,快速而简便
时代发展到今天,如果没有肥料,要想实现大规模的农业已经不可能了。为了满足近 80 亿人以及家养动物和工业用途的需求,需种植足够数量的农产品,有不同营养成分的肥料可供选择来满足各种土壤类型的独特需求。有关肥料成分(如总氮、磷和钾)的信息可帮助您选择适合特定土壤的理想肥料。 传统上,这些成分是通过重量分析(例如磷、钾或硫酸盐)或使用 ICP-OES(例如磷或钾)来确定的。这些方法要么具有分析时间长、费力的样品前处理(重量分析)的缺点,要么需要昂贵的仪器和较高的运行成本 (ICP-OES)。本白皮书详细说明了测温滴定法是一种快速、经济的替代方法,可提供有关不同肥料中各种营养素含量的信息。
- WP-086用离子色谱质谱法测量有机酸和无机阴离子
本白皮书重点介绍用于直接鉴定和定量不同基质中有机酸和无机阴离子的特定 IC-MS 应用。