Metrosep A Supp 16 - 150/4.0

Metrosep A Supp 16 - 150/4.0

6.1031.420

Metrosep A Supp 16 - 150/4.0

vi

6.1031.420

Tổng quan

The Metrosep A Supp 16 is ideal for high-capacity separation problems and distinguishes itself with its outstanding resolution. The Metrosep A Supp 16 - 150/4.0 is based on a surface-functionalized polystyrene-divinylbenzene copolymer. The functional groups are bonded covalently.

The Metrosep A Supp 16 - 150/4.0 is characterized by outstanding resolution and solves the most difficult separation problems. The column is very well-suited to applications that have a high ionic load but that do not require the highest resolution. It is one of the standard columns in anion chromatography.

Thông số kỹ thuật

Housing materialPEEK
Carrier materialPolystyrene-divinylbenzene copolymer with quaternary ammonium groups
Particle size4.6 µm
Standard flow0.8 mL/min
Maximum pressure20 MPa
Maximum flow1.2 mL/min
pH range0–14
Column dimensions 150 x 4.0 mm
Temperature range10–70 °C

Sắc ký đồ

  • Sắc ký đồ
  • Sắc ký đồ
  • Sắc ký đồ
This field is required.
    • Threaded stopper
    • 6.2744.060
    • For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.
    • <p>For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.</p>
    • PCS
    • 2
    • Threaded stopper
    • 6.2744.060
    • For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.
    • <p>For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.</p>
    • PCS
    • 2
    • Metrosep A Supp 16 Guard/4.0
    • 6.1031.500
    • The Metrosep A Supp 16 Guard/4.0 reliably protects the Metrosep A Supp 16 analytical separation columns against contamination. Thanks to the "On Column Guard System", the guard column is very easy to handle. The guard column screws easily onto the analytical column. No tools are required.
    • <p>The Metrosep A Supp 16 Guard/4.0 reliably protects the Metrosep A Supp 16 analytical separation columns against contamination. Thanks to the "On Column Guard System", the guard column is very easy to handle. The guard column screws easily onto the analytical column. No tools are required.</p>
    • PCS
    • 1
    • Metrosep A Supp 16 S-Guard/4.0
    • 6.1031.510
    • The Metrosep A Supp 16 S-Guard/4.0 reliably protects the Metrosep A Supp 16 analytical separation columns against contamination. The guard column is connected to the separation column simply using capillary connections. No tools are required.
    • <p>The Metrosep A Supp 16 S-Guard/4.0 reliably protects the Metrosep A Supp 16 analytical separation columns against contamination. The guard column is connected to the separation column simply using capillary connections. No tools are required.</p>
    • PCS
    • 1