Ag/AgCl reference electrode with KCl (length 12.5 cm)
6.0726.107
Ag/AgCl reference electrode with KCl (length 12.5 cm)
vi
6.0726.107
Tổng quan
Silver / silver chloride reference electrode with double junction system, installation length 10 cm.
The SGJ 14/15 enables easy assembly and the flexible ground-joint diaphragm, which is insensitive to contamination, can be easily replaced. The reference and bridge electrolyte can be freely selected according to the application and are easy to exchange. This sensor is pre-filled with c(KCl) = 3 mol/L as reference and bridge electrolyte.
Thông số kỹ thuật
| Shaft material | Glass |
|---|---|
| Temperature range, long-term (°C) | 0 ... 80 |
| Temperature range, short-term (°C) | 0 ... 80 |
| Max. installation length (mm) | 100 |
| SGJ sleeve | Standard ground-joint 14/15 |
| Shaft diameter top (mm) | 12 |
| Shaft diameter bottom (mm) | 12 |
| Min. immersion depth (mm) | 10 |
| Electrode plug-in head | Metrohm socket B |
| Diaphragm | Ground-joint diaphragm |
| Reference electrolyte type | c(KCl) = 3 mol/L |
| Bridge electrolyte type | c(KCl) = 3 mol/L |
| Reference system | Ag wire/AgCl |
| Electrolyte outflow (µL/h) with reference to 3 mol/L KCl | 5...50 |
| Reference resistance (kΩ) with reference to 3 mol/L KCl | <3 |
-
- Cable strand, length 0.55 m
- 6.02105.000
- Electrode cables (1x banana plug 4 mm, 1x banana plug 2 mm) to connect a disconnected reference electrode to an analog measuring input in an OMNIS titration system.
- <p>Electrode cables (1x banana plug 4 mm, 1x banana plug 2 mm) to connect a disconnected reference electrode to an analog measuring input in an OMNIS titration system.</p>
- PCS
- 1
- Cable strand, length 1.5 m
- 6.02105.010
- Electrode cables (1x banana plug 4 mm, 1x banana plug 2 mm) to connect a disconnected reference electrode to an analog measuring input in an OMNIS titration system, length 1.5 m.
- <p>Electrode cables (1x banana plug 4 mm, 1x banana plug 2 mm) to connect a disconnected reference electrode to an analog measuring input in an OMNIS titration system, length 1.5 m.</p>
- PCS
- 1
- Diaphragm for reference electrode
- 6.1243.030
- Spare ground-joint diaphragm for 6.0726.1XX and 6.0729.1XX reference electrodes
- Spare ground-joint diaphragm for 6.0726.1XX and 6.0729.1XX reference electrodes
- PCS
- 1
- Strand / 1 m / 2 x B
- 6.2106.020
- Electrode cable with 2 x plug B (4 mm) for connecting electrodes with plug-in head B
- Electrode cable with 2 x plug B (4 mm) for connecting electrodes with plug-in head B
- PCS
- 1
- Strand / 2 m / 2 x B
- 6.2106.060
- Electrode cable with 2 x plug B (4 mm) for connecting electrodes with plug-in head B
- Electrode cable with 2 x plug B (4 mm) for connecting electrodes with plug-in head B
- PCS
- 1
- Electrolyte 3 mol/L KCl (250 mL)
- 6.2308.020
- Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
- Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
- PCS
- 1