Ag/AgCl reference electrode with KCl (length 12.5 cm)

Ag/AgCl reference electrode with KCl (length 12.5 cm)

6.0726.107

Ag/AgCl reference electrode with KCl (length 12.5 cm)

en

6.0726.107

Feature overview

Silver / silver chloride reference electrode with double junction system, installation length 10 cm.
The SGJ 14/15 enables easy assembly and the flexible ground-joint diaphragm, which is insensitive to contamination, can be easily replaced. The reference and bridge electrolyte can be freely selected according to the application and are easy to exchange. This sensor is pre-filled with c(KCl) = 3 mol/L as reference and bridge electrolyte.

Tech specs

Shaft materialGlass
Temperature range, long-term (°C)0 ... 80
Temperature range, short-term (°C)0 ... 80
Max. installation length (mm)100
SGJ sleeveStandard ground-joint 14/15
Shaft diameter top (mm)12
Shaft diameter bottom (mm)12
Min. immersion depth (mm)10
Electrode plug-in headMetrohm socket B
DiaphragmGround-joint diaphragm
Reference electrolyte typec(KCl) = 3 mol/L
Bridge electrolyte typec(KCl) = 3 mol/L
Reference systemAg wire/AgCl
Electrolyte outflow (µL/h) with reference to 3 mol/L KCl5...50
Reference resistance (kΩ) with reference to 3 mol/L KCl<3
This field is required.
    • Cable strand, length 0.55 m
    • 6.02105.000
    • Electrode cables (1x banana plug 4 mm, 1x banana plug 2 mm) to connect a disconnected reference electrode to an analog measuring input in an OMNIS titration system.
    • <p>Electrode cables (1x banana plug 4 mm, 1x banana plug 2 mm) to connect a disconnected reference electrode to an analog measuring input in an OMNIS titration system.</p>
    • PCS
    • 1
    • Cable strand, length 1.5 m
    • 6.02105.010
    • Electrode cables (1x banana plug 4 mm, 1x banana plug 2 mm) to connect a disconnected reference electrode to an analog measuring input in an OMNIS titration system, length 1.5 m.
    • <p>Electrode cables (1x banana plug 4 mm, 1x banana plug 2 mm) to connect a disconnected reference electrode to an analog measuring input in an OMNIS titration system, length 1.5 m.</p>
    • PCS
    • 1
    • Diaphragm for reference electrode
    • 6.1243.030
    • Spare ground-joint diaphragm for 6.0726.1XX and 6.0729.1XX reference electrodes
    • Spare ground-joint diaphragm for 6.0726.1XX and 6.0729.1XX reference electrodes
    • PCS
    • 1
    • Strand / 1 m / 2 x B
    • 6.2106.020
    • Electrode cable with 2 x plug B (4 mm) for connecting electrodes with plug-in head B
    • Electrode cable with 2 x plug B (4 mm) for connecting electrodes with plug-in head B
    • PCS
    • 1
    • Strand / 2 m / 2 x B
    • 6.2106.060
    • Electrode cable with 2 x plug B (4 mm) for connecting electrodes with plug-in head B
    • Electrode cable with 2 x plug B (4 mm) for connecting electrodes with plug-in head B
    • PCS
    • 1
    • Electrolyte 3 mol/L KCl (250 mL)
    • 6.2308.020
    • Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
    • Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
    • PCS
    • 1