This metal electrode has to be used in combination with a reference electrode (c(KNO3) = 1 mol/L as reference electrolyte) and is well suited for precipitation titrations (titrant silver nitrate). The robust shaft made of polypropylene and the metal rod can be replaced separately. The silver rod is coated with sulfide (Ag2S) for higher sensitivity.

Thông số kỹ thuật

Shaft materialPP
Measuring range (theoretical)–2000 ... 2000
Measuring unitmV
Temperature range, long-term (°C)0 ... 80
Temperature range, short-term (°C)0 ... 80
SGJ sleeveStandard ground-joint 14/15
Min. immersion depth (mm)5
Electrode plug-in headMetrohm socket B negative with cable (l = 1 m)
Indicator electrode typeAg
Indicator electrode shapePin
Sản phẩm này đã ngừng sản xuất, nhưng vẫn được hỗ trợ.
    • Ag/AgCl reference electrode (length 12.5 cm)
    • 6.0729.100
    • Silver/silver chloride reference electrode with Double-Junction System and separate shielding, installation length 10 cm.This reference electrode is well-suited for:Nonaqueous samples; Differential potentiometry; The standard ground-joint 14/15 enables easy assembly, and the flexible ground-joint diaphragm, which is insensitive to contamination, can be replaced at any time. The reference electrolyte and the bridge electrolyte can be selected freely according to use, and are easy to replace. The sensor is supplied without electrolyte filling.
    • <p>Silver/silver chloride reference electrode with Double-Junction System and separate shielding, installation length 10 cm.<br/>This reference electrode is well-suited for:</p><ul><li>Nonaqueous samples</li><li>Differential potentiometry</li></ul><p>The standard ground-joint 14/15 enables easy assembly, and the flexible ground-joint diaphragm, which is insensitive to contamination, can be replaced at any time. The reference electrolyte and the bridge electrolyte can be selected freely according to use, and are easy to replace. The sensor is supplied without electrolyte filling.</p>
    • PCS
    • 1
    • Electrode shaft
    • 6.1241.030
    • Electrode shaft for separate metal pin electrodes
    • Electrode shaft for separate metal pin electrodes
    • PCS
    • 1
    • Strand / 1 m / 2 x B
    • 6.2106.020
    • Electrode cable with 2 x plug B (4 mm) for connecting electrodes with plug-in head B
    • Electrode cable with 2 x plug B (4 mm) for connecting electrodes with plug-in head B
    • PCS
    • 1
    • Electrolyte KNO3-1mol/L 250 mL
    • 6.2310.010
    • Electrolyte solution KNO3 1 M (reference electrolyte for combined silver electrodes)
    • Electrolyte solution KNO<SUB>3</SUB> 1 M (reference electrolyte for combined silver electrodes)
    • PCS
    • 1