Foi redireccionado para a sua versão local da página solicitada.
Separate Ag-rod electrode with Ag2S coating

Separate Ag-rod electrode with Ag2S coating

6.0331.010S

Separate Ag-rod electrode with Ag2S coating

en

6.0331.010S

Visão geral

This metal electrode has to be used in combination with a reference electrode (c(KNO3) = 1 mol/L as reference electrolyte) and is well suited for precipitation titrations (titrant silver nitrate). The robust shaft made of polypropylene and the metal rod can be replaced separately. The silver rod is coated with sulfide (Ag2S) for higher sensitivity.

Especificações técnicas

Shaft materialPP
Measuring range (theoretical)–2000 ... 2000
Measuring unitmV
Temperature range, long-term (°C)0 ... 80
Temperature range, short-term (°C)0 ... 80
SGJ sleeveStandard ground-joint 14/15
Min. immersion depth (mm)5
Electrode plug-in headMetrohm socket B negative with cable (l = 1 m)
Indicator electrode typeAg
Indicator electrode shapePin
Este produto foi descontinuado, mas ainda é suportado.
    • Ag/AgCl reference electrode (length 12.5 cm)
    • 6.0729.100
    • Silver/silver chloride reference electrode with Double-Junction System and separate shielding, installation length 10 cm.This reference electrode is well-suited for:Nonaqueous samples; Differential potentiometry; The standard ground-joint 14/15 enables easy assembly, and the flexible ground-joint diaphragm, which is insensitive to contamination, can be replaced at any time. The reference electrolyte and the bridge electrolyte can be selected freely according to use, and are easy to replace. The sensor is supplied without electrolyte filling.
    • <p>Silver/silver chloride reference electrode with Double-Junction System and separate shielding, installation length 10 cm.<br/>This reference electrode is well-suited for:</p><ul><li>Nonaqueous samples</li><li>Differential potentiometry</li></ul><p>The standard ground-joint 14/15 enables easy assembly, and the flexible ground-joint diaphragm, which is insensitive to contamination, can be replaced at any time. The reference electrolyte and the bridge electrolyte can be selected freely according to use, and are easy to replace. The sensor is supplied without electrolyte filling.</p>
    • PCS
    • 1
    • Electrode shaft
    • 6.1241.030
    • Electrode shaft for separate metal pin electrodes
    • Electrode shaft for separate metal pin electrodes
    • PCS
    • 1
    • Strand / 1 m / 2 x B
    • 6.2106.020
    • Electrode cable with 2 x plug B (4 mm) for connecting electrodes with plug-in head B
    • Electrode cable with 2 x plug B (4 mm) for connecting electrodes with plug-in head B
    • PCS
    • 1
    • Electrolyte KNO3-1mol/L 250 mL
    • 6.2310.010
    • Electrolyte solution KNO3 1 M (reference electrolyte for combined silver electrodes)
    • Electrolyte solution KNO<SUB>3</SUB> 1 M (reference electrolyte for combined silver electrodes)
    • PCS
    • 1