Chuyển hướng tin nhắn
Robotic Acid-Base Analyzer

Robotic Acid-Base Analyzer

2.855.1020

Sản phẩm này đã ngừng sản xuất, nhưng vẫn được hỗ trợ.
    • Aquatrode Plus
    • 6.0253.100
    • Combined pH electrode for pH titrations in ion-deficient aqueous media (e.g., drinking water, process water). This electrode shows a very short response time in these samples. The fixed ground-joint diaphragm is insensitive to contamination. When c(KCl) = 3 mol/L is used as bridge electrolyte, storage in storage solution is recommended.The bridge electrolyte can be easily replaced with a chloride-free electrolyte (e.g., potassium nitrate c(KNO3) = 1 mol/L (6.2310.010)). Storage in the used bridge electrolyte.
    • <p>Combined pH electrode for pH titrations in ion-deficient aqueous media (e.g., drinking water, process water). This electrode shows a very short response time in these samples. The fixed ground-joint diaphragm is insensitive to contamination. <br/><br/>When c(KCl) = 3 mol/L is used as bridge electrolyte, storage in storage solution is recommended.<br/>The bridge electrolyte can be easily replaced with a chloride-free electrolyte (e.g., potassium nitrate c(KNO<sub>3</sub>) = 1 mol/L (6.2310.010)). Storage in the used bridge electrolyte.</p>
    • PCS
    • 1
    • Titration Head, 3 x SGJ 14
    • 6.1458.040
    • Titration head for 120 mL beakers. With 3 openings SGJ 14 and 4 openings 6.4 mm, 2 dosing tips included. Suitable for rinsing and aspiration equipment.
    • Titration head for 120 mL beakers. With 3 openings SGJ 14 and 4 openings 6.4 mm, 2 dosing tips included. Suitable for rinsing and aspiration equipment.
    • PCS
    • 1
    • Sample beaker, plastic (PP), 120 mL, 250 pieces 
    • 6.1459.300
    • Sample beaker, plastic (polypropylene, PP), 120 mL, suitable for sample racks: 6.2041.470, 6.2041.840, 6.2041.850, 6.2068.010, 6.2068.020, 6.2068.030, and 6.9920.141, 250 pieces 
    • <p>Sample beaker, plastic (polypropylene, PP), 120 mL, suitable for sample racks: 6.2041.470, 6.2041.840, 6.2041.850, 6.2068.010, 6.2068.020, 6.2068.030, and 6.9920.141, 250 pieces<br/> </p>
    • PCS
    • 1
    • Aspiration tip / M8 thread
    • 6.1543.170
    • Aspiration tip for the Sample Processors.
    • <p>Aspiration tip for the Sample Processors.</p>
    • PCS
    • 1
    • Piston tongs
    • 6.1546.030
    • For pistons for 807 Dosing Units or cylinder units OMNIS.
    • <p>For pistons for 807 Dosing Units or cylinder units OMNIS.</p>
    • PCS
    • 1
    • Container 10 L
    • 6.1621.000
    • As rinsing or waste container in automated systems.
    • As rinsing or waste container in automated systems.
    • PCS
    • 2
    • Stirring propeller / 102 mm
    • 6.1909.050
    • Propeller for 802 Stirrer when this is used with sample racks for 120 mL beakers (6.1459.300)
    • Propeller for 802 Stirrer when this is used with sample racks for 120 mL beakers (6.1459.300)
    • PCS
    • 1
    • Bottle holder base, right, to 855
    • 6.2001.120
    • Bottle holder base for assembly on the right next to the tower of the 855 Robotic Titrosampler.
    • Bottle holder base for assembly on the right next to the tower of the 855 Robotic Titrosampler.
    • PCS
    • 1
    • Sample rack, 59 x 120 mL, (PVC)
    • 6.2041.840
    • Sample rack for 815 Robotic USB Sample Processor XL, 855 Robotic Titrosampler "Basic", suitable for 59 sample beakers. The following sample beakers can be used: 6.1459.300, 6.1459.307.Plastic: Polyvinyl chloride (PVC)
    • <p>Sample rack for 815 Robotic USB Sample Processor XL, 855 Robotic Titrosampler "Basic", suitable for 59 sample beakers. The following sample beakers can be used: 6.1459.300, 6.1459.307.</p><p>Plastic: Polyvinyl chloride (PVC)</p>
    • PCS
    • 1
    • Cable clip
    • 6.2053.000
    • Cable clip for fastening cables and tubes
    • Cable clip for fastening cables and tubes
    • PCS
    • 1
    • Bottle holder for Dosinos
    • 6.2061.010
    • Bottle holder for up to two Dosinos, mounted on 1 L reagent bottles.
    • Bottle holder for up to two Dosinos, mounted on 1 L reagent bottles.
    • PCS
    • 1
    • Electrode cable / 1 m / F
    • 6.2104.020
    • For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
    • For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
    • PCS
    • 1
    • Electrolyte 3 mol/L KCl (50 mL)
    • 6.2308.050
    • Electrolyte solution c(KCl) = 3 mol/L (for Ag/AgCl reference systems)
    • Electrolyte solution c(KCl) = 3 mol/L (for Ag/AgCl reference systems)
    • PCS
    • 1
    • Storage solution
    • 6.2323.000
    • Storage solution for all combined pH glass electrodes with reference electrolyte c(KCl) = 3 mol/L
    • Storage solution for all combined pH glass electrodes with reference electrolyte c(KCl) = 3 mol/L
    • PCS
    • 1
    • Spray nozzle
    • 6.2740.020
    • For the fine-spraying of the rinsing solution.
    • <p>For the fine-spraying of the rinsing solution.</p>
    • PCS
    • 3
    • Safety shield
    • 6.2751.100
    • Safety shield for Sample Processors with 786 Swing Head
    • <p>Safety shield for Sample Processors with 786 Swing Head</p>
    • PCS
    • 1
    • 807 Dosing Unit 20 mL
    • 6.3032.220
    • 807 Dosing Unit with integrated data chip with 20 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.
    • <p>807 Dosing Unit with integrated data chip with 20 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.</p>
    • PCS
    • 1
    • 800 Dosino (cable length 1.5 m)
    • 1.800.0030
    • Drive with write/read hardware for intelligent dosing units. With permanently attached cable (length 1.5 m).
    • <p>Drive with write/read hardware for intelligent dosing units. With permanently attached cable (length 1.5 m).</p>
    • PCS
    • 1
    • 802 Rod Stirrer for 727 Ti Stand
    • 1.802.0010
    • Rod stirrer with separate 6.2137.000 Speed controller and 6.1909.010 Propeller stirrer.
    • Rod stirrer with separate 6.2137.000 Speed controller and 6.1909.010 Propeller stirrer.
    • PCS
    • 1
    • 855 Robotic Titrosampler "Basic" (1T/2P)
    • 1.855.0020
    • Basic model for setting up customer-specific automation in the titration. Space-saving Robotic Sample Processor XL with integrated Titrando, one workstation including Swing Head and two built-in membrane pumps. The programming of the methods is accomplished by means of the handy Touch Control or with the tiamo™ titration software.
    • <p>Basic model for setting up customer-specific automation in the titration. Space-saving Robotic Sample Processor XL with integrated Titrando, one workstation including Swing Head and two built-in membrane pumps. The programming of the methods is accomplished by means of the handy <strong>Touch Control</strong> or with the <strong>tiamo</strong>™ titration software.</p>
    • PCS
    • 1
    • Aquatrode Plus
    • 6.0253.100
    • Combined pH electrode for pH titrations in ion-deficient aqueous media (e.g., drinking water, process water). This electrode shows a very short response time in these samples. The fixed ground-joint diaphragm is insensitive to contamination. When c(KCl) = 3 mol/L is used as bridge electrolyte, storage in storage solution is recommended.The bridge electrolyte can be easily replaced with a chloride-free electrolyte (e.g., potassium nitrate c(KNO3) = 1 mol/L (6.2310.010)). Storage in the used bridge electrolyte.
    • <p>Combined pH electrode for pH titrations in ion-deficient aqueous media (e.g., drinking water, process water). This electrode shows a very short response time in these samples. The fixed ground-joint diaphragm is insensitive to contamination. <br/><br/>When c(KCl) = 3 mol/L is used as bridge electrolyte, storage in storage solution is recommended.<br/>The bridge electrolyte can be easily replaced with a chloride-free electrolyte (e.g., potassium nitrate c(KNO<sub>3</sub>) = 1 mol/L (6.2310.010)). Storage in the used bridge electrolyte.</p>
    • PCS
    • 1
    • Titration Head, 3 x SGJ 14
    • 6.1458.040
    • Titration head for 120 mL beakers. With 3 openings SGJ 14 and 4 openings 6.4 mm, 2 dosing tips included. Suitable for rinsing and aspiration equipment.
    • Titration head for 120 mL beakers. With 3 openings SGJ 14 and 4 openings 6.4 mm, 2 dosing tips included. Suitable for rinsing and aspiration equipment.
    • PCS
    • 1
    • Sample beaker, plastic (PP), 120 mL, 250 pieces 
    • 6.1459.300
    • Sample beaker, plastic (polypropylene, PP), 120 mL, suitable for sample racks: 6.2041.470, 6.2041.840, 6.2041.850, 6.2068.010, 6.2068.020, 6.2068.030, and 6.9920.141, 250 pieces 
    • <p>Sample beaker, plastic (polypropylene, PP), 120 mL, suitable for sample racks: 6.2041.470, 6.2041.840, 6.2041.850, 6.2068.010, 6.2068.020, 6.2068.030, and 6.9920.141, 250 pieces<br/> </p>
    • PCS
    • 1
    • Aspiration tip / M8 thread
    • 6.1543.170
    • Aspiration tip for the Sample Processors.
    • <p>Aspiration tip for the Sample Processors.</p>
    • PCS
    • 1
    • Piston tongs
    • 6.1546.030
    • For pistons for 807 Dosing Units or cylinder units OMNIS.
    • <p>For pistons for 807 Dosing Units or cylinder units OMNIS.</p>
    • PCS
    • 1
    • Container 10 L
    • 6.1621.000
    • As rinsing or waste container in automated systems.
    • As rinsing or waste container in automated systems.
    • PCS
    • 2
    • Stirring propeller / 102 mm
    • 6.1909.050
    • Propeller for 802 Stirrer when this is used with sample racks for 120 mL beakers (6.1459.300)
    • Propeller for 802 Stirrer when this is used with sample racks for 120 mL beakers (6.1459.300)
    • PCS
    • 1
    • Bottle holder base, right, to 855
    • 6.2001.120
    • Bottle holder base for assembly on the right next to the tower of the 855 Robotic Titrosampler.
    • Bottle holder base for assembly on the right next to the tower of the 855 Robotic Titrosampler.
    • PCS
    • 1
    • Sample rack, 59 x 120 mL, (PVC)
    • 6.2041.840
    • Sample rack for 815 Robotic USB Sample Processor XL, 855 Robotic Titrosampler "Basic", suitable for 59 sample beakers. The following sample beakers can be used: 6.1459.300, 6.1459.307.Plastic: Polyvinyl chloride (PVC)
    • <p>Sample rack for 815 Robotic USB Sample Processor XL, 855 Robotic Titrosampler "Basic", suitable for 59 sample beakers. The following sample beakers can be used: 6.1459.300, 6.1459.307.</p><p>Plastic: Polyvinyl chloride (PVC)</p>
    • PCS
    • 1
    • Cable clip
    • 6.2053.000
    • Cable clip for fastening cables and tubes
    • Cable clip for fastening cables and tubes
    • PCS
    • 1
    • Bottle holder for Dosinos
    • 6.2061.010
    • Bottle holder for up to two Dosinos, mounted on 1 L reagent bottles.
    • Bottle holder for up to two Dosinos, mounted on 1 L reagent bottles.
    • PCS
    • 1
    • Electrode cable / 1 m / F
    • 6.2104.020
    • For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
    • For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
    • PCS
    • 1
    • Electrolyte 3 mol/L KCl (50 mL)
    • 6.2308.050
    • Electrolyte solution c(KCl) = 3 mol/L (for Ag/AgCl reference systems)
    • Electrolyte solution c(KCl) = 3 mol/L (for Ag/AgCl reference systems)
    • PCS
    • 1
    • Storage solution
    • 6.2323.000
    • Storage solution for all combined pH glass electrodes with reference electrolyte c(KCl) = 3 mol/L
    • Storage solution for all combined pH glass electrodes with reference electrolyte c(KCl) = 3 mol/L
    • PCS
    • 1
    • Spray nozzle
    • 6.2740.020
    • For the fine-spraying of the rinsing solution.
    • <p>For the fine-spraying of the rinsing solution.</p>
    • PCS
    • 3
    • Safety shield
    • 6.2751.100
    • Safety shield for Sample Processors with 786 Swing Head
    • <p>Safety shield for Sample Processors with 786 Swing Head</p>
    • PCS
    • 1
    • 807 Dosing Unit 20 mL
    • 6.3032.220
    • 807 Dosing Unit with integrated data chip with 20 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.
    • <p>807 Dosing Unit with integrated data chip with 20 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.</p>
    • PCS
    • 1
    • 849 Level Control
    • 2.849.0010
    • Additional equipment for Sample Processors for monitoring the filling level of rinsing or waste canisters via Remote. Prevents pumps from running dry and/or canisters from overflowing and is suitable for use with aqueous solutions, solvents and suspensions.
    • Additional equipment for Sample Processors for monitoring the filling level of rinsing or waste canisters via Remote. Prevents pumps from running dry and/or canisters from overflowing and is suitable for use with aqueous solutions, solvents and suspensions.
    • PCS
    • 1
    • OMNIS Software storage device
    • 6.06000.000
    • License-based PC program for controlling complex OMNIS analysis systems. Sample-oriented operating procedures with numerous templates; Graphical method editor with numerous templates; Clearly organized and professional sample lists; Management of instruments, work systems, sensors, solutions; Dialog languages: German, English, Chinese;   
    • <p>License-based PC program for controlling complex OMNIS analysis systems. </p><ul><li>Sample-oriented operating procedures with numerous templates</li><li>Graphical method editor with numerous templates</li><li>Clearly organized and professional sample lists</li><li>Management of instruments, work systems, sensors, solutions</li><li>Dialog languages: German, English, Chinese</li></ul><p> </p><p> </p>
    • PCS
    • 1
    • OMNIS Stand-Alone license
    • 6.06003.010
    • Enables stand-alone operation of the OMNIS software on a Windows™ computer.Features:The license already includes one OMNIS instrument license.; Must be activated via the Metrohm licensing portal.; Not transferable to another computer.;  
    • <p>Enables stand-alone operation of the OMNIS software on a Windows™ computer.<br/><br/>Features:</p><ul><li>The license already includes one OMNIS instrument license.</li><li>Must be activated via the Metrohm licensing portal.</li><li>Not transferable to another computer.</li></ul><p> </p>
    • PCS
    • 1
    • Remote Box MSB
    • 6.2148.010
    • Additional remote interface for the connection of devices that can be controlled via remote lines. With permanently attached cable.
    • Additional remote interface for the connection of devices that can be controlled via remote lines. With permanently attached cable.
    • PCS
    • 1