CVS electrode equipment with 2 mm platinum electrode, gel reference electrode and steel auxiliary electrode for Professional VA/CVS instruments
6.5339.110
CVS electrode equipment with 2 mm platinum electrode, gel reference electrode and steel auxiliary electrode for Professional VA/CVS instruments
en
6.5339.110
Överblick över funktioner
Complete electrode set for the determination of organic additives in electroplating baths with CVS (Cyclic Voltammetric Stripping). Contains rotating platinum working electrode (electrode diameter: 2 mm), driving axle with mercury contact, maintenance-free gel reference electrode, steel auxiliary electrode, measuring vessels and KCl electrolyte solution.
-
- Separate steel electrode
- 6.0343.110
- Steel auxiliary electrode for CVS
- <p> Steel auxiliary electrode for CVS</p>
- PCS
- 1
- Complete LL-Ag/AgCl(gel) reference electrode
- 6.0730.100
- Maintenance-free Double-Junction Ag/AgCl reference electrode for voltammetry. Made of glass with electrolyte c(KCl) = 3 mol/L (gel), for pH 0 - 8. Suitable for use in continuous operation in automated systems and online instruments.
- <p>Maintenance-free Double-Junction Ag/AgCl reference electrode for voltammetry. Made of glass with electrolyte c(KCl) = 3 mol/L (gel), for pH 0 - 8. Suitable for use in continuous operation in automated systems and online instruments.</p>
- PCS
- 1
- Driving axle for rotating disk electrode (RDE) with mercury contact
- 6.1204.520
- Driving axle for rotating disk electrode (RDE) with titanium axle and mercury contact for Professional VA/CVS instruments, M3 thread.
- <p>Driving axle for rotating disk electrode (RDE) with titanium axle and mercury contact for Professional VA/CVS instruments, M3 thread.</p>
- PCS
- 1
- 2 mm platinum electrode tip for CVS
- 6.1204.610
- Metal electrode tip made of platinum (Pt), diameter of electrode disk 2 mm ±0.05 mm, polished surface, shaft made of glass, M3 thread connection. Concentricity error: < 0.3 mm. Temperature range: 0 - 50 °C.
- <p>Metal electrode tip made of platinum (Pt), diameter of electrode disk 2 mm ±0.05 mm, polished surface, shaft made of glass, M3 thread connection. Concentricity error: < 0.3 mm. Temperature range: 0 - 50 °C.</p>
- PCS
- 1
- Titration vessel / 10-90 mL
- 6.1415.210
- PCS
- 1
- Titration vessel / 50-150 mL
- 6.1415.250
- PCS
- 1
- Electrolyte 3 mol/L KCl (250 mL)
- 6.2308.020
- Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
- Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
- PCS
- 1
-
- Separate steel electrode
- 6.0343.110
- Steel auxiliary electrode for CVS
- <p> Steel auxiliary electrode for CVS</p>
- PCS
- 1
- Complete LL-Ag/AgCl(gel) reference electrode
- 6.0730.100
- Maintenance-free Double-Junction Ag/AgCl reference electrode for voltammetry. Made of glass with electrolyte c(KCl) = 3 mol/L (gel), for pH 0 - 8. Suitable for use in continuous operation in automated systems and online instruments.
- <p>Maintenance-free Double-Junction Ag/AgCl reference electrode for voltammetry. Made of glass with electrolyte c(KCl) = 3 mol/L (gel), for pH 0 - 8. Suitable for use in continuous operation in automated systems and online instruments.</p>
- PCS
- 1
- Driving axle for rotating disk electrode (RDE) with mercury contact
- 6.1204.520
- Driving axle for rotating disk electrode (RDE) with titanium axle and mercury contact for Professional VA/CVS instruments, M3 thread.
- <p>Driving axle for rotating disk electrode (RDE) with titanium axle and mercury contact for Professional VA/CVS instruments, M3 thread.</p>
- PCS
- 1
- 2 mm platinum electrode tip for CVS
- 6.1204.610
- Metal electrode tip made of platinum (Pt), diameter of electrode disk 2 mm ±0.05 mm, polished surface, shaft made of glass, M3 thread connection. Concentricity error: < 0.3 mm. Temperature range: 0 - 50 °C.
- <p>Metal electrode tip made of platinum (Pt), diameter of electrode disk 2 mm ±0.05 mm, polished surface, shaft made of glass, M3 thread connection. Concentricity error: < 0.3 mm. Temperature range: 0 - 50 °C.</p>
- PCS
- 1
- Titration vessel / 10-90 mL
- 6.1415.210
- PCS
- 1
- Titration vessel / 50-150 mL
- 6.1415.250
- PCS
- 1
- Electrolyte 3 mol/L KCl (250 mL)
- 6.2308.020
- Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
- Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
- PCS
- 1