Aplikácie
- AN-T-250Potentiometric analysis of rare earth elements (REEs)
Rare earth elements (REEs) are critical materials whose deposit viability and processing streams require accurate mass-fraction determination during ore dissolution and purification. This Application Note describes a rapid potentiometric back-titration using a copper ion-selective electrode (Cu-ISE) that enables selective quantification and partial separation of REEs in complex matrices with near-quantitative recovery. As an absolute, flexible, and cost-effective method with ICP-compatible sample preparation, back-titration is well suited both as a reference technique and for rapid on-site analysis.
- AN-T-068Determination of coconut oil ethoxylates (nonionic surfactants)
This application note shows how coconut oil ethoxylates can be determined via potentiometric titration.
- AN-T-014Chlorhexidine in a wash lotion
Determination of chlorhexidine in wash lotion by potentiometric titration with sodium tetraphenylborate using the NIO surfactant electrode.
- AN-K-022Water in pesticide formulations
This Application Note describes the determination of water content in pesticides using Karl Fischer titration.
- AN-H-060Standardization of 0.1 mol/L perchloric acid in glacial acetic acid
Standardization of 0.1mol/L perchloric acid in glacial acetic acid by catalyzed endpoint thermometric titration.
- AN-H-032Standardization of ammonium ferrous sulfate solution
Standardization of 0.1 mol/L ammonium ferrous sulfate solution for use in thermometric titration of Cr(VI) solutions.
- AB-195Titrimetric determination of free boric acid and tetrafluoroboric acid in nickel plating baths
This Bulletin describes the simultaneous potentiometric titration of free boric acid and free tetrafluoroboric acid in nickel plating baths. After addition of mannitol, the formed mannitol complexes are titrated with sodium hydroxide solution. The determination is carried out directly in the plating bath sample; nickel and other metal ions do not interfere.
- AN-T-234Direct comparison of OMNIS and Titrando for mixed acids and TMAH
This Application Note compares the OMNIS Titrator and 888 Titrando for determinations of nitric acid, phosphoric acid, and acetic acid in an aluminum etching bath, as well as the determination of tetramethylammonium hydroxide (TMAH). Identical analysis parameters were used, showing that OMNIS delivers results on par or even better than with other established titration systems.
- AN-T-100Chloride in acidic copper baths
Acid copper baths are mainly used for the copper deposition on semiconductor wafers. Small amounts of chloride increase the speed of deposition and reduce anode polarization. However, higher concentrations are undesired, as this will decrease the quality of the copper deposition. Therefore, it is quite important to monitor the amount of chloride to have an effective, yet high-quality copper deposition process.In this Application Note, a fully automated solution based on titration is presented. In comparison to ion chromatography, titration offers the benefit that no dilution of the sample is necessary, and the hardware is comparatively low-priced. Furthermore, the fully automated solution allows users to minimize handling errors, to reduce workloads, and to guarantee outstanding reproducibility.
- AN-T-017Determination of ampicillin content
Determination of ampicillin in raw and pure products through potentiometric titration with Hg(II) using the combined Au electrode. Keyword: Antibiotics
- AN-T-016Nonionic surfactants in compact washing powders
Determination of nonionic surfactants in compact washing powders by potentiometric titration with sodium tetraphenylborate using the NIO surfactant electrode.
- AN-T-066Calcium in cheese
Determination of calcium in cheese by potentiometric titration with EGTA using the Cu-ISE.
- AN-T-046Soap content of soap noodles
Determination of the soap content of soap noodles by potentiometric titration with TEGO®trant A100 using the «Ionic Surfactant» electrode.
- AN-T-008Sulfate in brine
Determination of sulfate in brine by indirect potentiometric titration with EGTA using platinum and tungsten electrodes.
- AN-T-038Iron content of iron powder
Determination of the iron content of iron powder by potentiometric titration with potassium dichromate using the Pt-Titrode.
- AN-T-065Astemizole in raw products
Determination of the antihistamine astemizole in raw products by nonaqueous potentiometric titration with perchloric acid using separate electrodes.
- 8.000.6021Water analysis
A complete tap water analysis includes the determination of the pH value, the alkalinity and the total water hardness. Both the pH measurement and the pH titration by means of a standard pH electrode suffer from several drawbacks. First, the response time of several minutes is too long and, above all, the stirring rate significantly influences the measured pH value. Unlike these standard pH electrodes, the Aquatrode Plus with its special glass membrane guarantees rapid, correct and very precise pH measurements and pH titrations in solutions that have a low ionic strength or are weakly buffered. Total water hardness is ideally determined by a calcium ion-selective electrode (Ca ISE). In a complexometric titration, calcium and magnesium can be simultaneously determined up to a calcium/magnesium ratio of 10:1. Detection limits for both ions are in the range of 0.01 mmol/L.
- AN-T-136Epoxide equivalents in epoxy resin
The epoxy content of epoxy resins has a strong influence on the reactivity of the resins as well as on the properties of the coating obtained from the resin curing process. The epoxy content is thus an important quality control parameter for manufacturers as well as consumers. This analysis is based on the reaction of hydrogen bromide with the epoxy groups of the sample. Hydrogen bromide in turn is produced by the reaction of tetraethylammonium bromide (TEABr) with standardized perchloric acid. The standards EN ISO 3001 and ASTM D1652 describe the determination of the epoxy content expressed as epoxy equivalent weight (EEW) by titration. The use of a Titrando and Solvotrode easyClean instead of manual titration greatly increases the reproducibility and repeatability of the determination.
- AN-H-052Determination of nickel in electroless plating solutions
Thermometric titration of nickel in electroless plating solution with disodium dimethylglyoximate.
- AN-T-050Nonionic surfactant nonylphenol ethoxylate (8 EO)
This application note describes the determination of nonylphenol ethoxylate by potentiometric titration with sodium tetraphenylborate using the NIO surfactant electrode.
- AN-H-091Standardization of tetrasodium EDTA solutions with standard magnesium solution
Standardization of 1 mol/L tetrasodium EDTA (Na4EDTA) solutions by titration with standard magnesium solution.
- AN-T-026Perborate, percarbonate, or persulfate in washing powder
Determination of perborate, percarbonate, or persulfate in washing powder by iodometric potentiometric titration using the Pt-Titrode.
- AN-T-012Cationic surfactants in hair conditioner
Determination of cationic surfactants in hair conditioner by potentiometric titration with dioctyl sodium sulfosuccinate using the «Ionic Surfactant electrode.
- AN-T-187Bromine number in petroleum distillate
The bromine number indicates the degree of unsaturation and relies on the simple addition of bromine to the double bonds of alkenes. One mole of bromine is consumed for each mole of carbon-carbon double (C=C) bond present in a substance. In petroleum products, the bromine number corresponds to the olefin content.Normally, chlorinated solvents are used for the determination of the bromine number. In this Application Note they have been replaced by toluene. This makes the determination more ecological. The titration is performed automatically on an OMNIS system in combination with a double Pt-wire electrode. With this setup, a fast and accurate determination by potentiometric titration can be realized.
- AB-053Determination of ammonium or Kjeldahl nitrogen
The potentiometric titration of Kjeldahl nitrogen is one of the most common analytic procedures. It is referenced in numerous standards, ranging from the food and animal feed industries through sewage and waste analysis and all the way to the fertilizer industry. As a rule, the samples are digested with concentrated sulfuric acid with the addition of a catalyst. The ammonium sulfate that is formed is distilled as ammonia in alkali solution, collected in an absorption solution and titrated there.This Bulletin provides a detailed description of potentiometric nitrogen determination following distillation of the digestion solution, followed by a discussion of the possibilities of coulometric titration (without distillation).
- 8.000.6108Comparative Study of Moisture Analysis Techniques on Cannabis
Moisture in cannabis impacts potency and must be accurately determined. Loss on drying (LOD) is the most popular method for determining moisture in cannabis. Unfortunately, this technique is not specific to moisture and the loss of any volatile components, such as terpenes, will be incorrectly classified as moisture. Karl Fischer (KF) titration is the only chemically specific test for moisture. This poster describes the instrument used to determine moisture content by Karl Fischer titration and compares the results of this data to loss on drying.
- AN-H-011Determination of the total solids content of drilling fluids
Thermometric titration is presented as a simple, fast, and reliable method to determine calcium content in various drilling fluids.
- AN-T-070Determination of calcium pantothenate
Determination of calcium pantothenate by nonaqueous potentiometric titration with perchloric acid using separate electrodes.
- AN-K-046Water in calcium carbonate (chalk, lime)
The water content in Ca carbonate is determined by volumetric Karl Fischer titration.
- AN-H-033Determination of low levels of chloride in water
Determination of low levels of chloride (to approximately 5 mg/L Cl-) by thermometric titration.
- AN-K-054Determination of the water content in tablets
This Application Note describes the determination of the water content in tablets using automated volumetric titration including sample preparation (MATi 11).
- AN-T-010Anionic surfactants in shower lotions and shampoos
Determination of anionic surfactants in shower lotions and shampoos by potentiometric titration with TEGO®trant A100 using the «Ionic Surfactant» electrode.
- AN-T-210Assay of potassium carbonate and potassium bicarbonate
This Application Note presents a potentiometric titration method for a potassium bicarbonate and potassium carbonate assay meeting all USP General Chapter <1225> requirements.
- AN-T-015Nonionic surfactants in liquid household cleaners
This application note shows a reliable way to determine the content of non-ionic surfactants in liquid cleaning solutions by potentiometric titration.
- AB-037Determination of chromium in iron and steel
Two methods are described for the determination of chromium: a biamperometric titration and a polarographic analysis.
- AN-H-141Acid number in crude oil and gas oil according to ASTM D8045
Thermometric titration can determine the total acid number (TAN) of various crude oil products according to ASTM D8045 without requiring any sensor maintenance.
- AN-T-039Free alkali in sodium hypochlorite
Determination of free alkali in sodium hypochlorite by potentiometric titration with hydrochloric acid using a combined glass electrode.
- AN-H-098Determination of hydrofluoric acid in silicon etch solutions
This Application Note describes the determination of fluoride in silicon etch solutions with thermometric titration.
- AN-T-238Determination of the alkalinity (p-value and m-value) in water
Alkalinity defines the acid-binding capacity of natural water. A distinction is made between total alkalinity (m-value) and carbonate alkalinity (p-value). This Application Note presents the determination of pH and alkalinity in water with a titration method conforming to EPA 310.1, Standard Methods 2320 B (Titration Method), ASTM D1067, EN ISO 9963-1, and EN ISO 9963-2.
- AN-K-018Water in cyclopropyl methyl ketone
The water content of cyclopropyl methyl ketone is determined according to Karl Fischer by coulometric titration using special reagents for aldehydes and ketones.
- AN-T-181Lithium in brine
Lithium is a soft metal which is used for many applications, such as production of high-temperature lubricants or heat-resistant glass. Furthermore, lithium is used in large quantities in for battery production. It is obtained from brines and high-grade lithium ores. Depending on the lithium concentration, extraction may or may not be economically viable.This Application Note demonstrates a method to determine the lithium concentration in brines by potentiometric titration. Lithium and fluoride precipitate in ethanol as insoluble lithium fluoride. Using ammonium fluoride as the titrant and a fluoride ion-selective electrode (ISE), determination via potentiometric titration is possible. This method is more reliable, faster, and less expensive than the determination of lithium in brine by other more sophisticated techniques such as atomic absorption spectroscopy (AAS).
- AB-068Potentiometric determination of carboxyl and amino terminal groups in polyamide fibers
Indication of the titration endpoint of the weakly alkaline or weakly acidic terminal groups in non-aqueous solution is frequently not easy. An improvement is possible by using a suitable titrant (TBAH = tetrabutylammonium hydroxide for terminal carboxyl groups; perchloric acid for terminal amino groups).An improvement in the evaluation can also be achieved by choosing benzyl alcohol as the solvent.The choice of electrode combination and the measuring setup is also important. Differential potentiometry using the three-electrode technique results in a great improvement in titrations in poorly conducting solutions. Noisy signals are eliminated.
- AN-H-066Carbonate and bicarbonate in solution
Determination of bicarbonate and carbonate in a mixture by sequential thermometric titrations.
- AN-T-021Sn(II) and sulfuric acid in a tin plating bath
Determination of Sn(II) and sulfuric acid in an acidic tin plating bath by potentiometric titration.
- AN-T-006Trace chloride in cement and clinker
Determination of trace chloride in cement and clinker by potentiometric titration with silver nitrate using the Ag-Titrode.
- AN-T-037Nitrogen content of nitrocellulose
Determination of the nitrogen content of nitrocellulose by potentiometric titration with Fe(II) using a combined Pt electrode.
- AN-T-040Determination of phenylglycine content
Determination of phenylglycine through nonaqueous potentiometric titration with sodium methylate using a special combined glass electrode. Keyword: Antibiotics
- AN-T-072Reducing sugars in wine and candies
Determination of reducing sugars in wine and candies according to Fehlings method by potentiometric/iodometric titration using the Pt-Titrode.
- AN-K-053Determination of the water content in toothpaste with MATi 10
This Application Note describes the automated determination of the water content in toothpaste using volumetric Karl Fischer titration (MATi 10).
- AN-K-005Water in ink
Determination of water content in ink is possible with Karl Fischer titration, as shown in this Application Note.
- AN-T-045Acetate, chloride, and phosphate in an infusion solution
Determination of acetate, chloride, and phosphate in an infusion solution by potentiometric titration with sodium hydroxide after conversion of the anions to the corresponding acids.
- AN-T-011Anionic surfactants in a nickel plating bath
Determination of anionic surfactants in a nickel plating bath by potentiometric titration with TEGO®trant A100 using the «Ionic Surfactant» electrode.
- AN-T-027Alkalinity of amine-containing gas washing solutions
Determination of the alkalinity of gas washing solutions containing alkanolamines by potentiometric titration with sulfuric acid using the combined glass electrode.
- AN-K-019Water in urea
In this application note, Karl Fischer titration is used to determine the water content of urea.
- AN-K-039Water in penicillin-G-potassium
This application note describes the water content determination in penicillin by using volumetric Karl Fischer titration. Unwanted side reactions can be avoided by using special solvent mixtures.
- AN-T-036Benzydamine hydrochloride in a disinfectant solution
Determination of benzydamine hydrochloride {1-benzyl-3-[3-(dimethylamino)-propoxy]-1H-indazole hydrochloride} in disinfectant solution by potentiometric titration with sodium tetraphenylborate using the NIO surfactant electrode.
- AN-T-062Analysis of nitrite solutions
Determination of nitrite in aqueous solutions by potentiometric back-titration of the added permanganate excess with ammonium iron(II) sulfate using the Pt-Titrode.
- AN-H-082Determination of surface acidity in Zeolites and other materials with a high specific surface area
This Application Note outlines the determination of total acidic active surface sites in zeolites with thermometric titration.
- AN-K-042Water in silicone oil
The water content of silicone oil is determined according to Karl Fischer by coulometric titration.
- AN-T-226Determination of functional groups in graphite and graphene oxide
Boehm titration is a quantitative analysis of functional groups on the surface of carbon materials based on their reactions with basic solutions of NaHCO3 (pKa = 6.4), Na2CO3 (pKa = 10.3), and NaOH (pKa = 15.7). This is a cost-efficient method that gives absolute values with high precision of the accessible, mainly oxygen-containing functional groups on the surface. Originally, Boehm titration was developed for carbon materials like conductive carbon black (CCB), activated carbon, porous carbon, and graphite. Modern carbon-based materials like graphene, graphene oxide (GO), or carbon nanotubes can also be analyzed this way.
- AN-H-083Determination of surface basicity in zeolites and other materials with a high specific surface area
This Application Note shows that the parameter of surface basicity of zeolites can be measured by thermometric titration.
- AN-K-051Determination of the water content in spirits with MATi 10
This Application Note describes the automated determination of the water content in liqueur (30% v/v) using volumetric Karl Fischer titration (MATi 10).
- AN-T-152Automatic determination of mercaptans in refinery products
Potentiometric titration with silver nitrate can be used for the determination of mercaptans in refinery products. This Application Note describes their automatic determination in a middle distillate sample (gas oil).
- AN-H-042Standardization of thiosulfate titrant for copper determinations
This Application Note discusses the standardization of thiosulfate titrant for use in the determination of copper with thermometric titration.
- AN-T-071Determination of palladium using the «Ionic Surfactant» electrode
Determination of palladium(II) by potentiometric titration with hexadecylpyridinium chloride using the «Ionic Surfactant» electrode.
- AN-H-130Determination of nitrite using sulfamic acid
This Application Note describes the determination of nitrite using thermometric endpoint titration with sulfamic acid. The nitrite content of a solution can be analyzed down to 0.2 mmol/L.
- AN-T-087Carboxyl end groups in polymers – Photometric determination based on ASTM D7409
The carboxyl end groups (CEG) in polymers, such as polyethylene terephthalate (PET), are a measure of the number of unreacted carboxylic acid groups at each end of a polymer chain. The number of CEGs may influence the hydrolysis resistance of geosynthetics, such as geogrids and geotextiles. The lower the CEG value the higher is the hydrolysis resistance of geosynthetics, which in turn increases their stability.This Application Note describes the photometric titration of carboxyl end groups in PET pellets using the Metrohm Optrode. The acidic end groups of the polymer are titrated with an ethanolic KOH solution using bromophenol blue as indicator.
- AN-T-035Tranexamic acid in injection solutions
Determination of tranexamic acid in injection solutions by nonaqueous potentiometric titration with perchloric acid using a glass electrode.
- AN-T-134Chloride in salted butter – Automated standard method reduces saves time and helps increase throughput
The salt content in food is a critical parameter, given that the WHO recommends a maximum daily intake of 5 g for an adult. In butter with a salt content exceeding 0.1%, it can be determined by a precipitation titration of chloride with silver nitrate. However, during manual titration the operator cannot leave the system unattended because he has to exchange the sample beakers manually which is time consuming and prone to errors.This Application Note describes the automated determination of chloride in salted butter in accordance with ISO 15648, ISO 21422, IDF 179 and IDF 242. If automated according to the norms and standards, salt determination can be performed completely unattended with superior reproducibility of results increasing efficiency in the laboratory.
- AN-K-026Water in used lubricating oil
The water content of used lubricating oil is determined according to Karl Fischer by coulometric titration. To prevent unwanted side reactions special KF reagents are used.
- AN-T-013Cationic surfactant (cetrimide) in an antiseptic disinfectant
Determination of the cationic surfactant «cetrimide» in an antiseptic disinfectant by potentiometric titration with sodium dodecyl sulfate using the «Ionic Surfactant» electrode.
- AN-H-064Total base number (TBN) in used motor oils
The determination of the total base number (TBN) in motor oils is accomplished by means of titration with a standard solution made up of trifluoromethanesulfonic acid in glacial acetic acid and isobutyl vinyl ether as reagent for improved end point identification.
- AN-T-133Chloride in milk and milk powder
In order to maintain product quality, the sodium chloride content in dairy products must be monitored and not exceed the limits defined by the respective public health authorities. The chloride content in food correlates with the salt content, its determination is therefore described in various norms and standards. However, preparation of such samples is time consuming, as it includes a chloride extraction with warm water. Whole milk powders in particular are difficult to handle as an inhomogeneous dispersion of fat in the titration suspension occurs.In order to reduce the workload, increase sample throughput, and eliminate the matrix challenges posed by high fat products, this Application Note presents a fully automatic potentiometric titration of chloride with silver nitrate in milk and milk powder based on ISO 21422, IDF 242, AOAC 2015.07, AOAC 2015.08 and AOAC 2016.03
- AN-K-052Determination of the water content in sodium acetate with MATi 10
In this application note, Karl Fischer titration is used to determine water content in sodium acetate trihydrate. The MATi 10 allows this determination to be automated, saving users time in the laboratory.
- AN-K-010Water in coal dust
The water content of coal dust is determined according to Karl Fischer. Because of the low water content of the voluminous sample, the oven method (nitrogen, 270 °C) and coulometric titration have to be used.
- AN-K-008Water in plastic chips
The water content of plastic chips is determined according to Karl Fischer. Because of the low water content of the sample, the oven method (200 °C) and coulometric titration have to be used.
- AN-T-022Cyanide in alkaline plating baths for cadmium, copper, lead or zinc
Determination of cyanide in alkaline plating baths by potentiometric titration with silver nitrate using the Ag-Titrode.
- AN-T-031Na2O (free base) and SiO2 (silicate) in water glass
Determination of Na2O and SiO2 in water glass by potentiometric titration with HCl using the Sb electrode.
- AN-T-029Alkyllead (anti-knock agent) in gasoline
Determination of alkyllead compounds in petrol (gasoline) after reaction with iodine monochloride by potentiometric titration with EDTA using the Cu-ISE.
- AN-K-014Water in diesel fuel and gasoline
The water content of diesel fuel and petrol (gasoline) is determined according to Karl Fischer. Because of the low water content, the determinations are carried out by coulometric titration.
- AN-K-012Water in turbine oil
The water content of turbine oil is determined according to Karl Fischer. Because of the low water content of the sample, coulometric titration is used.
- AN-H-096Determination of total base number of lubricating oils
Dissolution of oil in toluene, and titration with standard 0.1 mol/L trifluoromethanesulfonic acid in acetic acid using isobutyl vinyl ether as a thermometric endpoint indicator.
- AN-H-010Determination of calcium in drilling fluids
Thermometric titration quickly and accurately assesses the total solids content of fluids employed in drilling oil and gas wells within minutes.
- AN-T-043Bromine index in low-level standards
Determination of the bromine index in low-level standards by bivoltametric titration with bromide/bromate using a double Pt electrode.
- AN-H-123Determination of sodium in instant noodles
This Application Note describes the determination of the total sodium content in instant noodles which are also called «two minute noodles» in some countries. These products contain considerable amounts of sodium (at least 50% of the recommended daily dosage), which means that precise analysis of the sodium content is required. Argentometric titration of the chloride content (assuming that the sodium content in the noodles originates exclusively from the sodium chloride that is added to them) is unsuitable for precise analysis, as the nutrient contents listed on the product packaging document the presence of additional sodium salts other than sodium chloride. Thermometric titration enables fast and direct determination of sodium. In addition to this application note, you can find more information on thermometric sodium determination in foods in our application video available on YouTube:https://youtu.be/lnCp9jBxoEs
- AN-T-024Metal contents of alkaline plating baths for cadmium, copper, lead or zinc
Determination of cadmium, copper, lead, and zinc in alkaline plating baths by potentiometric titration with EDTA using the Cu-ISE.
- AN-T-156Determination of surfactants on the basis of sugar and polyoxyethylene
Alkyl glycosides, alkyl maltosides and compounds with polyoxyethylene groups (POE) are numbered among the nonionic surfactants. These surfactants can be analyzed by standard titration with TEGO®trant following derivatization – in this case following sulfonation.
- AN-T-063Citrate in mineral water drinks
Determination of citrate in mineral water drinks by potentiometric titration with copper sulfate using the Cu-ISE. Before the determination, the sample is degassed and passed through a cation-exchange resin.
- AN-T-130Automatic determination of lead in aqueous solution with the Cu ISE
Lead can be analyzed with the Cu ISE. Diammonium tartrate is added to the solution to prevent the precipitation of lead hydroxide in the alkali titration medium.
- AN-T-161Sulfate in salts of laxatives and expectorants in accordance with Ph. Eur. 8.0
The composition of salts with laxative and expectorant effects must be determined precisely in medications. The sulfate content is determined using automatic potentiometric titration with EGTA as titrant in accordance with Ph. Eur. 8.0.
- AN-T-020Cr(VI) and Cr(III) in chromium baths
Determination of Cr(VI) and Cr(III) in chromium baths by iodometric potentiometric titration with thiosulfate using the combined Pt electrode.
- AN-T-093Total base number in used engine oil – Fully automatic photometric determination increases reliability of results
Basic additives are added to petroleum products to inhibit corrosion as they have a neutralizing effect on acidic compounds, which are formed as a result of degradation processes. Total base number (TBN) indicates the amount of basic additives present and thus can be used as a measure for the degradation of the petroleum product.Using an automated titration system with a photometric sensor to detect the end point ensures that the titrations are always carried out under the same conditions. This improves the precision and reliability of the results.This Application Notes describes the fully automated photometric determination of TBN in used engine oil using the Metrohm Optrode for the indication of the methyl orange endpoint (at 520 nm).
- AN-T-124Photometric copper determination in aqueous solution
Copper can be determined using photometric titration with EDTA at a wavelength of 520 nm.
- AN-H-124Determination of sodium content in the manufacturing of margarine
This Application Note describes the determination of the total concentration of sodium in precursor solutions used in the manufacturing of margarine. The solutions of the precursors are mixed with edible fats and oils to make margarine. Traces of sodium chloride and other sodium and potassium salts may be added to the margarine during this process, usually in the form of emulsifiers, stabilizers, antioxidants, vitamins, coloring agents or flavor enhancers. The analysis of the total sodium content in the precursor solutions is more efficient and cost-effective for the manufacturers than later total sodium content analyses in the final product.As a rule, argentometric titration of chloride is used for indirect determination of the sodium content of foodstuffs. The assumption behind this approach is that the chloride ions are present in a molar ratio of 1:1 with the sodium ions. This is however not the case when – as is usually the case with foodstuffs containing sodium – additional compounds containing sodium are also present in the margarine. The use of potassium chloride as a partial replacement for sodium chloride in some formulations is an additional source of error.The direct titration of sodium by means of thermometric endpoint titration (TET) eliminates these problems. TET is a direct determination method that not only takes into account the entire sodium content present in the solution but is also not hampered by the presence of potassium ions. In addition to this application note, you can find more information on thermometric sodium determination in foods in our application video available on YouTube:https://youtu.be/lnCp9jBxoEs
- AN-T-122Automatic thallium determination in aqueous solution using the ion-selective copper electrode (Cu ISE)
Thallium in aqueous solution can be determined using back titration in a weak acidic solution. The ion-selective copper electrode is used here as the indicator electrode.
- AB-280Automatic Karl Fischer water content determination with the 874 Oven Sample Processor
Generally speaking, the gas extraction or oven method can be used for all samples which release their water when they are heated up. The oven method is indispensable in cases in which the direct volumetric or coulometric Karl Fischer titration is not possible, either because the sample contains disruptive components or because the consistency of the sample makes it very difficult or even impossible to transfer it into the titration vessel.The present Application Bulletin describes automatic water content determination with the aid of the oven technique and coulometric KF titration, using samples from the food, plastic, pharmaceutical and petrochemical industry.
- AN-K-002Water in methyl ethyl ketone peroxide (butanone peroxide)
The water content of methyl ethyl ketone peroxide is determined according to Karl Fischer using two-component reagents in order to prevent unwanted side reactions. (Separate solvent is used to ensure a high excess of sulphur dioxide and amine in the titration vessel.)
- AN-T-019Cyanide and silver in a silver plating bath
Simultaneous determination of cyanide and silver in a silver plating bath by potentiometric titration with silver nitrate using the Ag-Titrode.
- AN-T-120Automatic manganese determination in aqueous solution using the ion-selective copper electrode (Cu ISE)
Manganese in aqueous solution can be determined using back titration in alkali solution. The ion-selective copper electrode is used here as the indicator electrode.
- AN-T-140Automatic photometric determination of lead using the Optrode
Lead is determined at pH 4 to 5 using back titration with zinc sulfate. Xylenol orange is used as an indicator for visualization of the equivalence point. The equivalence point is detected with the Optrode at a wavelength of 574 mm.
- AN-T-032Sulfide and hydrogen sulfide in water
This Application Note presents a potentiometric titration method for trace H2S analysis in water on an OMNIS system using silver nitrate and an Ag Titrode.
- AN-T-069Iron and nickel in binary mixtures
Determination of iron and nickel in binary mixtures by potentiometric titration with EDTA at different pH values using the Cu-ISE.
- AN-T-028Hydrogen sulfide and mercaptans in petroleum products
Simultaneous determination of hydrogen sulfide and mercaptans in petroleum products by potentiometric titration with silver nitrate using the Ag-Titrode.
- AN-T-169Determination of citrate in detergents in accordance with ASTM D4608
Citrate is used in detergents as a water softener for the prevention of lime deposits. The citrate or citric acid content is therefore an important parameter for the quality control of detergents that can be determined conveniently and precisely using titration with copper sulfate.
- AN-T-227Determination of sodium lactate
Sodium lactate is a salt form of lactic acid used in many regulated industries—therefore an accurate determination of the lactate content is required and is already covered in several norms. One such monograph by the US Pharmacopoeia (USP) results in high accuracies and well-defined titration curves but uses titrants and solvents that are more costly than necessary. In comparison, the presented modified method from Metrohm requires a 1:1 mixture of water and acetone and uses aqueous hydrochloric acid as titrant, resulting in an estimated cost reduction of 40% per titration compared to the USP method (USP–NF 2021, Issue 2). Furthermore, the time needed for each analysis is reduced to just 12% of the USP method (excluding blank determination). This Application Note presents both methods to determine lactate content and shows the results obtained on an OMNIS system.
- AN-H-126Determination of silver and nitric acid in silver electrolyte bath
Silver and nitric acid are determined in silver electrolyte solutions by means of thermometric titration. The method provides accurate results in a short time and is ideally suited for routine process control.
- AN-T-064Titanium and iron in mixtures
Simultaneous determination of titanium and iron by potentiometric titration with potassium dichromate using a platinum electrode. Before determination, Ti4+ and Fe3+ are reduced with Cr2+.
- AN-H-122Determination of sodium in canned fish products
This Application Note describes the determination of total sodium content in canned fish products using thermometric titration. In addition to this application note, you can find more information on thermometric sodium determination in foods in our application video available on YouTube:https://youtu.be/lnCp9jBxoEs
- AN-T-160Determination of the acid number in acrylic acid
Acrylic acid dimerizes spontaneously. Determining the dimer content is, therefore, a key part of the quality control for acrylic acid. One quality control parameter for the dimerization is the acid number. This Application Note describes its determination by automated, potentiometric titration.
- AN-T-185Determination of diamidoamine-based quaternary ammonium salts in fabric softener according to ASTM D5070
Quaternary ammonium salts are the active ingredients in fabric softener and require accurate determination to assess the cost and the performance of the fabric softener. This Application Note describes the determination of diamidoamine-based quaternary ammonium salts by potentiometric titration.
- AN-T-186Determination of dialkyl di-methyl quaternary ammonium salts in fabric softener according to ASTM D5070
Quaternary ammonium salts are the active ingredients in fabric softener and require accurate determination to assess the cost and the performance of the fabric softener. This Application Note describes the determination of dialkyl dimethyl quaternary ammonium salts by back titration.
- AN-T-023Hydroxide and carbonate in alkaline plating baths for cadmium, copper, lead, or zinc
Determination of hydroxide and carbonate in alkaline plating baths by potentiometric titration with HCl using the combined glass electrode.
- AN-T-042Citric and oxalic acid in mixtures
Citric acid and oxalic acid are present in many products, such as foods or chemical solvents (e.g., decontamination solutions). Both acids are reducing agents and citric acid is additionally a powerful antioxidant. Due to their mutual impact (buffer effect), a content calculation is only possible with correction factors for each acid. A fast and accurate determination by potentiometric titration using the dEcotrode plus and sodium hydroxide as titrant can be realized in this Application Note.
- AN-T-123Automatic zirconium determination in aqueous solution with ion-selective copper electrode (Cu ISE)
Zirconium can be analyzed quickly and easily in slightly acidic solutions with back titration. The ion-selective copper electrode is used in this Application Note to determine zirconium in aqueous solution.
- AN-H-116Determination of sulfate in phosphoric acid through the standard addition of sulfuric acid
This Application Note supplements AN-H-003 with the treatment of the standard addition of sulfate as sulfuric acid. This technique may be contemplated when either sulfate levels are too low for a satisfactory direct titration, or when the sample matrix hinders endpoint detection, leading to poor precision and accuracy.
- AN-H-121Determination of ferrous ion in acidic solutions with ceric solution
This Application Note looks at the determination of ferrous ion in acidic solutions from approximately 0.25 g/L by thermometric titration with ceric titrant. The exothermic oxidation reaction shows a sharp endpoint that is detected using the Thermoprobe as a sensitive temperature sensor.
- AN-PAN-1010Online analysis of sulfuric acid and zinc sulfate in the viscose process
Monitoring sulfuric acid and zinc sulfate in the viscose wet-spinning process is essential. Online potentiometric titration and colorimetric analysis are recommended for this purpose.
- AN-K-070Water in petroleum products
Moisture in petroleum products causes several issues: corrosion and wear in pipelines and storage tanks, an increase in debris load resulting in diminished lubrication, blocked filters, or even harmful bacterial growth. As a result, increased water content can lead to infrastructure damage, higher maintenance costs, or even unwanted downtimes.Coulometric Karl Fischer titration is the method of choice for low water content in petroleum products. Using a Karl Fischer oven to vaporize the water present in the sample prior to titration not only greatly reduces matrix interferences, it can also be fully automated. This allows a reliable and cost-efficient analysis of the water content according to ASTM D6304 (Procedure B) in products such as diesel, hydraulic oil, lubricant, additive, turbine oil, and base oil.
- AN-T-168EDTA in liquid hand soap in accordance with ASTM D1767
Complexing agents such as EDTA are used in soaps and other detergents in order to remove unwanted metal ions and to lower water hardness. The EDTA content in soaps and detergents can be determined using potentiometric titration with copper sulfate as titrant and the Cu-ISE as electrode.
- AN-PAN-1008Online analysis of sulfuric acid in the cumene process (phenol production)
Phenol is a key chemical intermediate used to manufacture polymers, synthetic fibers, resins, detergents, herbicides, and pharmaceuticals. Most phenol production relies on the cumene hydroperoxide route, in which acid cleavage generates phenol and acetone. This Process Application Note describes the online potentiometric titration of sulfuric acid using the 2060 TI EX Proof Process Analyzer to maintain tight process control, enhance phenol quality, and reduce chemical consumption.
- AN-T-103Fully automated determination of aluminum in aqueous solution
In many countries, the aluminum concentration in water is limited to 0.2 mg/L. This application note shows how the analysis of aluminum in water can be done fully automatically by complexometric titration with EDTA.
- AN-T-174Determination of hydrolyzable chloride content in liquid epoxy resin in accordance with ASTM D1726 (Method B)
The quantity of hydrolyzable chloride in epoxy resins has an influence on their reactivity and on the properties of the epoxy coating obtained.Rapid and accurate determination is possible with an OMNIS system using potentiometric titration with the dAg ring electrode and silver nitrate as the titrant.
- AB-119Potentiometric determination of trace bromide and iodide in chlorides
Bromide is removed from the sample as BrCN by distillation. The BrCN is absorbed in sodium hydroxide solution and decomposed with concentrated sulfuric acid, then the released bromide ions are determined by potentiometric titration with silver nitrate solution. Iodide does not interfere with the determination.Iodide is oxidized to iodate by hypobromite. After destruction of the excess hypobromite, the potentiometric titration (of the iodine released from iodate) is carried out with sodium thiosulfate solution. Bromide does not interfere, even in great excess.The described methods allow the determination of bromide and iodide in the presence of a large excess of chloride (e.g., in brine, seawater, sodium chloride, etc.).
- AB-025Coatings on silver electrodes
Ag electrodes are used for the indication of the potentiometric endpoints in precipitation titrations between silver and halide or sulfide ions. A coating on the silver ring may increase the sensitivity of the electrode and can thus reduce the limit of detection. This is why a variety of coated Ag electrodes are commercially available. This bulletin describes how the silver ring of Ag electrodes can be coated with AgCl, AgBr, AgI or Ag2S by electrolysis.
- AN-T-159Basicity and CPR in polyols according to ISO 14899
The basicity and the CPR (controlled polymerization rate) are very important parameters for the quality of polyols used in polyurethane production. The knowledge of these values is crucial to prevent gelation during handling in the production. In this Application Note their determination by automated, potentiometric titration according to ISO 14899 is described.
- AN-T-112Acid value and free fatty acids in edible oils
This Application Note describes the titration of acid value and free fatty acids in different edible oils, based on the standards EN ISO 660, USP<401>, and Ph.Eur. 2.5.1.
- AN-T-090Determination of zinc sulfate
This Application Note describes the photometric determination of zinc sulfate using the Optrode at a wavelength of 610 nm. Complexometric titration of zinc requires EDTA as titrant and Eriochrome Black T as indicator. The method fully complies with Ph. Eur. and USP.
- AN-T-188Iron content in iron ore
The total iron content in iron ore plays a central economic role for mining companies. The higher the iron content in the ore, the more profitable the mining operation. Therefore, a fast and accurate analysis is important to determine the most profitable areas to work.The iron ore is dissolved in hydrochloric acid at 80 °C. Afterwards, the iron is quickly and accurately determined by potentiometric titration using the Pt-ring electrode and potassium dichromate as titrant.
- AN-T-166Hydroxyl number in unsaturated polyester resin according to EN ISO 2554
The hydroxyl number indicates the amount of potassium hydroxide in milligrams required to neutralize the acetic acid taken up on acetylation of 1 g of an unsaturated polyester resin (UPR) containing free hydroxyl groups. In this Application Note the determination of the hydroxyl number by automated, potentiometric titration according to EN ISO 2554 using KOH in methanol as titrant is described.
- AN-T-212FOS/TAC in fermentation substrate – Reliable determination for the monitoring of biogas plants
The FOS/TAC value, sometimes referred to as VFA/TA, is a meaningful parameter for assessing both the current condition and the development of anaerobic digestion processes in a digester of a biogas plant. Knowledge of this value can help decrease the risk of acidification problems, which can result in a costly crash of the entire digestion process. Therefore, an accurate and reliable determination of the FOS/TAC value is important for both efficient and cost-effective production operations. This value is determined by an acid-base titration. Using the Eco Titrator from Metrohm equipped with an Ecotrode plus electrode, a reproducible and accurate determination of the FOS/TAC value is possible.
- AN-T-170Nitrilotriacetate (NTA) in detergents in accordance with ASTM D4954
Nitrilotriacetate (NTA) is a complexing agent that is used in detergents as a water softener. NTA forms complexes with metal ions such as Ca2+, Cu2+ and Fe3+ and thus prevents the formation of lime and its deposits. The NTA content is therefore an important parameter for the quality of detergents and is determined using back titration of an excess of copper nitrate.
- AN-T-117Automatic determination of aluminum and magnesium mixtures with ion-selective copper electrode (Cu ISE)
Aluminum and magnesium ion mixtures are analyzed using back-titration at different pH values. The ion-selective copper electrode is used here as the indicator electrode. First, the aluminum is determined in acidic solution and then the magnesium in alkali solution.
- AN-T-165Total acid number in unsaturated polyester resin according to EN ISO 2114
The total acid number (TAN) indicates the amount of potassium hydroxide required for neutralizing all carboxyl-terminated groups and free acids plus the free anhydride groups in an unsaturated polyester resin (UPR). In this Application Note the TAN determination using automated, potentiometric titration according to EN ISO 2114 using KOH in ethanol as titrant is described.
- AN-T-118Automatic determination of zinc and magnesium mixtures with ion-selective copper electrode (Cu ISE)
Zinc and magnesium ion mixtures are analyzed using back-titration at different pH values. The ion-selective copper electrode is used here as the indicator electrode. First, the zinc is determined in acidic solution and then the magnesium in alkali solution.
- AN-H-070Determination of ferric and cupric Ions in copper refining solutions
Determination of Fe3+ and Cu2+ in copper refining solutions by thermometric titration. It was found that the conventional approach of masking Fe3+ to permit the iodometric determination of Cu2+ is not possible in some copper refining solutions.
- AN-T-164Partial acid number in unsaturated polyester resin according to EN ISO 2114
The partial acid number (also partial acid value) describes the quantity of potassium hydroxide that is required for neutralizing all carboxyl-terminated groups and free acids plus half the anhydride groups in an unsaturated polyesterresin (UPR). This Application Note describes the determination of the partial acid value by automatic, potentiometric titration according to EN ISO 2114 using KOH in ethanol as titrant.
- AN-T-206Bromine index of petroleum-based hydrocarbons
The bromine index is an important parameter for the determination of aliphatic C=C double bonds in petroleum hydrocarbons. For the titration, a solvent mixture of glacial acetic acid, methanol, and dichloromethane is usually used.In this Application Note, the chlorinated solvent in the solvent mixture was replaced with toluene, resulting in a more environmentally beneficial method in comparison to ASTM D2710 and IP 299.
- AN-T-154Determination of alpha acids in hops according to EBC 7.4
The alpha acid level (AA%) in hops plays a major role in the bitterness they can impart to beer. The AA% can vary between 1% up to 20% in hops. During boiling in the brewing process, alpha acids transform into iso-alpha acids which make the beer bitter. For this reason, it is important for brewers to know the exact AA value of the hops they use. The determination of AA% in hops with conductometric titration according to the EBC method 7.4 is shown in this Application Note.
- AN-T-004Chloride in meat products
In order to maintain product quality, the sodium chloride content in meat products must be monitored, as the limit values defined by the respective public health authorities must not be exceeded. The chloride content in food correlates with the salt content, its determination is therefore described in various norms and standards. However, preparation of meat samples is time consuming, as it requires homogenization with a mixer and a chloride extraction with water.In order to reduce workload and working hours, this Application Note describes a fully automatic potentiometric titration of chloride with silver nitrate in meat products based on ISO 1841-2, including fully automated sample preparation using a Polytron homogenizer.
- AN-T-217Hypochlorite and sodium chloride in disinfectant
Sodium hypochlorite and sodium chloride can be effectively use as disinfectant for water and surfaces. The World Health Organization (WHO) recommends, depending on the application, concentrations in disinfectants of 1000 mg/L to 5000 mg/L NaOCl and up to 200 g/L NaCl.This Application Note demonstrates a reliable method to determine the hypochlorite and sodium chloride content in disinfectants by two subsequent argentometric titrations in the range recommended by the WHO.
- AB-206Titer determination in potentiometry
This Bulletin provides an overview of the potentiometric titer determination of current titrants. Many publications only describe methods with color indicators. However, the titration conditions chosen for the titer determination should resemble those used for the actual analysis as closely as possible. The tables contain suitable titrimetric standard substances and electrodes for selected titrants as well as additional information. Following this, an example is given to show what an SOP for a titer determination could look like.
- AN-T-200Potentiometric determination of acidity in ethanol according to ASTM D7795
Denatured fuel ethanol may contain additives such as corrosion inhibitors and detergents as well as contaminants from manufacturing that can affect the acidity of produced ethanol fuel. An increased acid content in solvents could lead to a variety of problems like a shorter storage stability or chemical corrosion.Using the dSolvotrode for indication, the acidity is determined as acetic acid by titration with sodium hydroxide as titrant.
- AN-H-118Determination of hydrochloric acid in acidic solutions containing iron and aluminum
The presence of the hydrated ion [Fe(H2O)6]3+ can interfere with the determination of «free acid» due to the low pKa value (~2.2) of this ion. Ions of metals such as Fe, Cu, and Al can be masked effectively with fluoride, and permit the determination of the acid content by thermometric alkalimetric titration with good accuracy and precision.
- AN-T-211Fully automated wine analysis – Determination of free and total sulfurous acid, reductants, total acidity and pH value according to OIV
The analysis of the reductants, free and total sulfurous acid, pH and total acidity of wine can be performed fully automated on an OMNIS system based on the directive OIV-MA-AS323-04B, OIV-MA-AS313-01 and OIV-MA-AS313-15.Added components like SO2 have preserving properties and affect the microbiological environment (anti-microbacterial and enzyme-deactivating), they trap fermentation byproducts such as acetaldehyde and suppress a coloring into brown. The bound and free sulfurous acid are in an equilibrium with each other and can be determined via iodometric titration. Iodometric titration is also the method of choice to quantify other reductants, such as dyes, tanning agents, degradation products of carbohydrates and ascorbic acid. Finally, the acidity of wine is an important quality parameter, which affects the color and taste of wines. The total acidity and the pH of wine can be determined on the same system. Hence, Metrohm offers an all-in-one solution for the analysis of these mentioned key parameters.
- AN-T-214Kjeldahl nitrogen in waste water
Nitrogen-based compounds are widely distributed in the environment and are essential growth nutrients for photosynthetic organisms. Therefore, it is important to monitor and control the amount of nitrogen compounds which are released into the environment.In this Application Note, a method to determine the nitrogen content in water by Kjeldahl digestion and distillation followed by a photometric or potentiometric titration according to ASTM D3590 is presented. The universality, precision, and reproducibility of the Kjeldahl method have made it the internationally recognized method for e.g. estimating the protein content in many matrices and it is the standard method to which all other methods are judged against.
- AN-T-167Isocyanate content of polyurethane raw materials
Polyurethane (PU) is a class of very important polymers due to its flexibility and insulating properties. It is used in various industries such as the automobile industry, in building construction, as well as in the production of synthetic fibers. PU is mostly produced via a chemical reaction between polyisocyanates and polyols.The isocyanate (NCO) content in the raw material is crucial to control its properties. This Application Note shows an easy and straightforward way to determine the NCO content in polyurethane raw materials using a fully automated titration system from Metrohm.
- 8.000.6062Water determination in various plastics
The presence of excessive water in plastics adversely affects the performance of polymeric goods which is why water determination is of crucial importance. This article describes the accurate and straightforward determination of the water content using the Karl Fischer Oven Method in ten different plastic types that are not amenable to direct Karl Fischer titration. The experiments revealed that besides the determination of the oven temperature, sample preparation is one of the most important steps of the analysis, especially in case of hygroscopic plastic samples.
- AN-T-191Determination of the silver in silver jewelry alloys according to EN ISO 11427 and GB/T 17832
The knowledge of the exact silver content of silver allows used for jewelry is very important to ensure the quality of jewelry. Therefore, the determination procedure is regulated internationally and nationally. A common approach is the titration with potassium bromide after an acidic digestion of the silver using a silver electrode for indication.
- AN-H-142Determination of metal-organic compounds
Metal-organic compounds are commonly used in organic chemistry, for example as Grignard reagents or as strong bases (e.g., butyl lithium compounds). The knowledge of the exact content of reactive species allows to better plan the required amounts for reactions preventing the waste of material or too low yields.This Application Note describes the analysis of metal organics by thermometric titration using 2-butanol as titrant. Due to the strongly exothermic nature of the reaction between 2-butanol with metal-organic compounds, a fast and quantitative analysis of these substances is possible.
- AN-T-229Determination of lime salts in sugar beet juices
About 20% of our sugar comes from sugar beet crops, mostly grown in Europe and the U.S. where the climate is temperate, whereas the other 80% is produced from sugar cane in tropical areas. Lime salts and pH are very important factors which are controlled during the sugar manufacturing process. Complexometric titration is often used to determine the concentration of lime salts in such kinds of samples. This Application Note presents a more robust method for determining calcium compounds in sugar beet juice. Subjectivity of color change determination is eliminated by using an ion selective electrode (ISE).
- AB-046Potentiometric determination of cyanide
The determination of cyanide is very important not only in electroplating baths and when decontaminating wastewater but, due to its high toxicity, also in water samples in general. Concentrations of 0.05 mg/L CN- can already be lethal for fish.This Bulletin describes the determination of cyanide in samples of different concentrations by potentiometric titration.Chemical reactions:2 CN- + Ag+ → [Ag(CN)2]-[Ag(CN)2]- + Ag+ → 2 AgCN
- AN-T-218Analysis of Li-ion battery cathode materials made from Co, Ni, and Mn
The lithium-ion battery market is continuously growing due to the tremendous demand for battery powered consumer products. So-called «NCMs», a mixture of nickel, cobalt, and manganese oxides, have been gathering interest as cathode materials, replacing traditional compounds like cobalt oxides.Quality analysis of the post-sintered materials or recycled batteries can be performed by titration, as demonstrated in this Application Note. A fully automated analysis of the corresponding metals can be performed with OMNIS and its pipetting equipment.
- AN-H-044Standardization of EDTA titrant by copper
Thermometric complexometric titration of metals is often performed with tetrasodium EDTA. This Application Note explains the standardization of tetrasodium EDTA titrant with copper.
- AN-T-084Total, calcium, and magnesium hardness in water samples
ASTM D8192 describes the photometric titration of the total hardness, calcium hardness, and magnesium hardness in water with an optical sensor for objective endpoint indication, increasing precision and reliability. The method is suitable for both colored and colorless samples such as groundwater, surface water, wastewater, and drinking water. Using a fully automated OMNIS system equipped with an Optrode ensures that the sample preparation and analysis are repeatable.
- AB-061Potentiometric determination of silver – Accurate determination according to EN ISO and GB/T standards
Silver is an important metal not only in jewelry and silverware but also in electrical conductors and contacts. The knowledge of the exact silver content in fine silver and silver alloys ensures that quality standards for jewelry and silverware are met. As for the plating industry, the knowledge of the amount of silver in silver plating baths helps to run the bath efficiently.While X-ray fluorescence (XRF) is a fast alternative to determine the silver content in fine silver and silver alloys, it can only determine the silver content of the outermost sections of the metal. In contrast, titration offers a more comprehensive solution considering the whole sample, thus preventing fraud by thick plating.This application bulletin describes the potentiometric determination of silver in fine silver and silver alloys accordingto EN ISO 11427, ISO 13756, GB/T 17823, and GB/T 18996 as well as in silver plating baths by a titration with potassium bromide or potassium chloride, respectively
- AN-T-199Photometric determination of acidity in ethanol according to ASTM D7795
Denatured fuel ethanol may contain additives such as corrosion inhibitors and detergents as well as contaminants from manufacturing that can affect the acidity of produced ethanol fuel. An increased acid content in solvents could lead to a variety of problems like a shorter storage stability or chemical corrosion. Using the Optrode with phenolphthalein as indicator, the acidity is determined as acetic acid by titration with sodium hydroxide as titrant.
- AB-089Potentiometric analysis of anodizing baths
This Bulletin describes potentiometric titration methods for checking sulfuric acid and chromic acid anodizing baths. In addition to the main components aluminum, sulfuric acid, and chromic acid, chloride, oxalic acid, and sulfate are determined.
- AN-T-055Determination of Lauryl Sulfate
Due to its price and wide availability, the anionic surfactant sodium lauryl sulfate (SLS; SDS) can be found in many detergents as an emulsifier or as a fat solvent e.g., in cleaning or cosmetic products. To avoid causing severe dry skin and hair, and thus skin irritation, regulations in many countries have restricted the sodium lauryl sulfate concentration in ready-to-use products to a range between 0.05–2.5% SLS. To control the concentration of SLS in different products, a titration is carried out with TEGO® trant A100 and the Optrode. The evaluation is done automatically by means of a software, leading to reliable and reproducible results.
- AN-H-148Potassium in potash
Potash is commonly mined from ore, deposited after ancient inland oceans evaporated. The potassium salt is then purified in evaporation ponds. At the end of this process, the potash is typically obtained as potassium chloride. Potash is mainly used as fertilizer, providing potassium—an essential nutrient—to plants. Additionally, it is used in the chemical industry and to produce medicine. Potassium content in potash is typically determined by flame photometry (F-AES) or ICP-OES. However, these techniques have high investment and running costs. By applying the historically used gravimetric precipitation reaction as a thermometric titration, it becomes possible to rapidly and inexpensively determine the potassium content in potash within minutes.
- AB-090Potentiometric analysis of tin plating baths
Potentiometric titration methods for the analysis of acid and alkaline tin plating baths are presented. The following methods are described: tin(II) / tin(IV) / total tin, free fluoroboric acid, or free sulfuric acid, chloride in acidic tin baths, free hydroxide, and carbonate in alkaline tin baths.
- AN-T-207Determination of bromine index of aromatic hydrocarbons according to ASTM D5776 and SH/T 1767
The bromine index is an important quality control parameter for the determination of aliphatic C=C double bonds in aromatic hydrocarbons and is thus a measure for the presence of aliphatic unsaturation in these materials. In situ generated bromine reacts with the aliphatic double bonds. When the titration is finished an excess of free bromine causes a sudden change in the measured potential thus indicating the equivalence point.
- 8.000.6047Fully automated potentiometric determination of the hydroxyl number (HN) according to ASTM E1899-08 and DIN 53240-2
Hydroxyl is an important functional group and knowledge of its content is required in many intermediate and end-use products such as polyols, resins, lacquer raw materials and fats (petroleum industry). The test method to be described determines primary and secondary hydroxyl groups. The hydroxyl number is defined as the mg of KOH equivalent to the hydroxyl content of 1 g of sample.The most frequently described method for determining the hydroxyl number is the conversion with acetic anhydride in pyridine with subsequent titration of the acetic acid released: H3C-CO-O-CO-CH3 + R-OH -> R-O-CO-CH3 + CH3COOH. However, this method suffers from the following drawbacks: - The sample must be boiled under reflux for 1 h (long reaction time and laborious, expensive sample handling) - The method cannot be automated - Small hydroxyl numbers cannot be determined exactly - Pyridine has to be used, which is both toxic and foul-smellingBoth standards, ASTM E1899-08 and DIN 53240-2, offer alternative methods that do not require manual sample preparation and therefore can be fully automated: The method suggested in ASTM E1899-08 is based on the reaction of the hydroxyl groups attached to primary and secondary carbon atoms with excess toluene-4-sulfonyl-isocyanate (TSI) to form an acidic carbamate. The latter can then be titrated in a non-aqueous medium with the strong base tetrabutyl- ammonium hydroxide (TBAOH). The method suggested in DIN 53240-2 is based on the catalyzed acetylation of the hydroxyl group. After hydrolysis of the intermediate, the remaining acetic acid is titrated in a non-aqueous medium with alcoholic KOH solution. The present work demonstrates and discusses an easy way to determine the hydroxyl number according to ASTM E1899-08 or DIN 53240-2 with a fully automated titrimetric system for a great variety of industrial oil samples.
- AN-T-203Acidity in volatile solvents and chemical intermediates
The presence of acidic components in volatile solvents could be a result of contamination, decomposition during storage, distribution or manufacture. An increased acid content in solvents could lead to a variety of problems like shorter storage stability or chemical corrosion. Using the Optrode for indication, the acidity is determined by photometric titration with sodium hydroxide as titrant and phenolphthalein as indicator. If the volatile solvent is water soluble, it is dissolved in deionized water, if not, it is dissolved in carbon-dioxide free ethanol.
- AB-322Fully automated potentiometric determination of the hydroxyl number (HN) according to ASTM E1899 and DIN EN ISO 4629-2
The presented titration system can be used for the fully automated determination of the hydroxyl number (HN) according to ASTM E1899 and EN ISO 4629-2. The method allows, the determination of polyols and oxooils without boiling under reflux or other sample preparation and is therefore a big benefit for laboratories that have to cope with a high sample throughput.The standards EN 15168 and DIN 53240-3 relay on the same analysis method as in ASTM E1899.
- AN-K-049Water in plastic pellets – Interference-free determination based on ASTM D6869
The water content, also called moisture content, of plastics is an important quality parameter, as it affects the properties and processability of some plastics. A high water content can lead to degradation of the plastic by hydrolysis or cause surface imperfections. Additionally, it can affect the physical properties of some plastics.For this analysis, the oven technique is used, as volatile compounds present in plastics will interfere, if the water content is directly determined by coulometric Karl Fischer titration. The water content determination in polycarbonate pellets, performed with the 885 Compact Oven Sample Changer and 899 Coulometer, is described in this Application Note.
- AN-PAN-1028Monitoring tetramethylammonium hydroxide (TMAH) in developer online
The chemicals used in the manufacture of semiconductors must exhibit an exceptional purity, because even traces of contaminants have a negative effect on electrical properties. For the manufacture of printed circuit boards, the light-sensitive photoresist applied to the substrate (wafer) is exposed to light at defined areas with the aid of a photo template and then developed in a chemical reaction. The developer contains 2.38 to 2.62% tetramethylammonium hydroxide (TMAH) and ensures that the exposed areas can be readily separated from the substrate. The monitoring of the TMAH concentration in the developer solution takes place with a process analyzer from Metrohm Applikon that is configured specially for titration. In addition to this, the analyzer helps with the mixing of the TMAH solutions.
- AN-T-213Ozone in water
Water treatment with ozone (O3) is a common procedure for the disinfection of swimming pools. It is important that a sufficient but not excessive amount of O3 is produced to disinfect the water. Otherwise, the remaining ozone could enter the swimming water, which could irritate the respiratory system or the skin of bathers.Ozone is also used in drinking and waste water treatment because it is significantly more effective than chlorine at inactivating or killing viruses and bacteria. This application note describes a method to determine the ozone concentration in water by potentiometric titration according to DIN 38408-3.
- AN-T-034Hydrofluoric and nitric acid in etching baths
Determination of hydrofluoric and nitric acid in etching baths by potentiometric titration.a) Determination of the total acid content using the combined Sb electrode and NaOH as titrant.b) Determination of hydrofluoric acid using the F-ISE and the titrant La(NO3)3.The concentration of nitric acid is then determined by calculation.
- AN-H-115Determination of hydrofluoric acid, ammonium fluoride, and maleic acid in acid cleaning solutions
A direct thermometric titration (TET) with 2 mol/L NaOH is used to determine the HF, NH4F, and maleic acid (C4H4O4) contents of acid cleaning solutions. Three endpoints (EPs) are obtained, which may be assigned as follows:EP1: C4H4O4 (pKa1 = 1.9), HF (pKa = 3.17)EP2: C4H4O4 (pKa2 = 6.07)EP2: NH4F (pKa = 8.2)The HF content is determined by subtracting the difference (EP2-EP1) from EP1.
- AN-T-074Conductivity, pH value, alkalinity, and hardness in tap water
In this application note, a fully automated system is presented which allows the determination of several parameters according to various standards within one analysis. These include conductivity (ISO 7888, EN 27888, ASTM D1125, EPA 120.1), the pH value (EN ISO 10523, ASTM D1293, EPA 150.1), alkalinity (EN ISO 9963, ASTM D1067, EPA 310.1), and Ca/Mg content (ISO 6059, ASTM D1126, EPA 130.2). Additionally, the system transfers the required sample volume into an external titration vessel for the analysis, reducing manual sample preparation. Furthermore, all sensors can be automatically calibrated and the titer of each titrant can also be determined.
- AN-T-075Conductivity, pH value, alkalinity, and chloride in tap water
In this application note, a fully automated system is presented which allows the determination of several parameters according to various standards within one analysis. These include conductivity (ISO 7888, EN 27888, ASTM D1125, EPA 120.1), pH value (EN ISO 10523, ASTM D1293, EPA 150.1), alkalinity (EN ISO 9963, ASTM D1067, EPA 310.1), and chloride content (ISO 9297, ASTM D512, EPA 325.3). Additionally the system transfers the required volume of sample into an external titration vessel, further reducing manual sample preparation. Furthermore, all sensors can be calibrated automatically and the titer of each titrant can also be determined.
- AB-087Analysis of dairy products
This Bulletin describes potentiometric titration methods for the determination of the acidity in milk and yoghurt according to DIN 10316, ISO/TS 11869, IDF/RM 150, ISO 6091 and IDF 86, the chloride content in milk, butter and cheese according to EN ISO 5943, IDF 88, ISO 15648, IDF 179, ISO 21422, and IDF 242. Additionally the determination of the sodium content in milk using the thermometric titration is described. The determination of the oxidation stability of butter in accordance to AOCS Cd 12b-92, ISO 6886 and GB/T 21121 as well as the determination of lactose in lactose free milk by ion chromatography is also described.For the determination of the pH value in dairy products see Application Bulletin AB-086 and for the determination of calcium and magnesium see Application Bulletin AB-235.
- AB-143Determination of complexing agents in detergents
Application Bulletin AB-076 contains a description of the polarographic determination of low concentrations (1–100 mg/L) of NTA and EDTA in bodies of water. NTA, EDTA and citrate have gained in importance as complexing agents and builders due to the fact that the laws of some countries have made it necessary to find a substitute for phosphates in detergents.This Bulletin describes the determination of larger quantities of complexing agents in detergents using potentiometric titration. The ion-selective copper electrode (Cu-ISE) is used here as the indicator electrode. The determination of complexing agents is not disturbed by the other constituents often present in detergents.
- AN-T-196Assay of Vitamin C
Vitamin C, also known as ascorbic acid or L-ascorbic acid, is an essential nutrient involved in the repair of tissues and the enzymatic production of certain neurotransmitters. It is required for the functioning of several enzymes and immune performance, and is also an important antioxidant. This nutrient is found in many foods and is often used as a dietary supplement.USP general chapter <580> describes a titration technique to determine the assay of Vitamin C as ascorbic acid, sodium ascorbate, and calcium ascorbate dehydrate, or their mixture in finished dosage forms as capsules, tablets, and oral suspensions. This Application Note demonstrates the Vitamin C determination in water-soluble vitamin tablets. The methodology can also be applied for oil-soluble vitamin or mineral tablets, as well as oil- and water-soluble vitamin or mineral capsules.
- AN-K-017Water in expandable polystyrene – Oven system with closed sample vials simplifies analysis
The presence of water in expandable polystyrene (EPS) can have a negative impact on the thermal insulation properties, as it increases thermal conductivity. If EPS is exposed to a high moisture environment, additional water may be absorbed, which can further affect thermal insulation.Direct analysis of the moisture content by Karl Fischer titration requires the water to be extracted from the EPS, which involves several time-consuming steps. Therefore, determination of the water content with an oven system is preferred. As EPS expands when heated, the use of sample boats, as required by ASTM D6869, is not possible, as the EPS will contaminate the oven system. This Application Note describes the determination of water content in EPS using an oven system with closed sample vials. A determination takes about 7 to 14 min depending on the water content of the sample and the sample size.
- AB-098Determination of ascorbic acid (Vitamin C) and its compounds
In addition to its natural occurrence in fruit and vegetables, ascorbic acid (Vitamin C) is used as an antioxidant in foods and drinks. Ascorbic acid is furthermore also to be found in numerous drugs.Ascorbic acid and its salts and esters can be determined with titration or by using polarography, for which ascorbic acid is oxidized to form dehydroascorbic acid.Bi-voltammetric or photometric equivalence point indication can be used for titrimetric determination. It must be taken into account here that only bi-voltammetric indication is independent of the inherent color of the sample. Polarography is the most selective of the methods described, as other reducing or oxidizing substances are not recorded.
- 8.000.6024Fully automated sample preparation for the content determination of tablets
Benzbromaron is one of the main uricosuric drugs currently used. In addition to sophisticated and expensive LC-MS and GC-MS methods, benzbromaron can be effectively determined by titration with sodium hydroxide solution using a straightforward, fully automated sample preparation method. A high-frequency homogenizer comminutes one or three tablets within 90 or 120 s respectively. The overall analysis time is 8 minutes. Ten-fold determinations with one and three tablets resulted in a benzbromaron content of 99.2 and 98.7 mg per tablet respectively. Increasing the number of tablets from one to three lowers the RSD from 1.36 to 0.88%. These results show an excellent agreement with the benzbromaron content indicated by the manufacturer (approx. 100 mg/tablet).Besides the presented Titrando/homogenizer combination, the other two members of the 815 Robotic Soliprep Sample Processor family offer comprehensive sample preparation possibilities within the fields of IC, HPLC, ICP or voltammetry.
- AN-T-076Conductivity, pH value, alkalinity, hardness, and chloride in tap water
In this application note, a fully automated system is presented which allows the determination of several parameters according to various standards within one analysis. These include conductivity (ISO 7888, EN 27888, ASTM D1125, EPA 120.1), pH value (EN ISO 10523, ASTM D1293, EPA 150.1), alkalinity (EN ISO 9963, ASTM D1067, EPA 310.1), Ca/Mg (ISO 6059, ASTM D1126, EPA 130.2), and chloride (ISO 9297, ASTM D512, EPA 325.3). Additionally the system transfers the required volume of sample into external titration vessels for the different analyses, reducing manual sample preparation. Furthermore, all sensors can be automatically calibrated and the titer of each titrant can also be determined.
- AN-T-135Chloride in cheese – Automation reduces sample preparation and increases throughput
The WHO recommends a maximum daily intake of 5 g salt for an adult. The chloride content in food correlates with the salt content, its determination is therefore described by various standards. In cheese and cheese products with a chloride content higher than 0.2%, chloride is usually determined by a precipitation titration with silver nitrate. However, time-consuming sample preparation is required, as the cheese has to be homogenized and the chloride extracted with hot water.This Application Note describes the fully automatic determination of chloride in cheese according to EN ISO 5943, ISO 21422, IDF 242 and IDF 88 including sample preparation with a Polytron homogenizer. This increases productivity due to a higher sample throughput and lower work load for the operator.
- 8.000.6048Fully automated determination of fluoride in blood samples
Sodium fluoride is used as a preservative in biological samples for alcohol analysis. All submitted blood samples, including those taken from vehicle drivers suspected of driving under the influence of liquor, have to be tested for adequate preservation prior to alcohol determination by gas chromatography. This is critical to ensure adequate sample preservation. Inadequate sample preservation may allow glycolysis and/or microorganism growth to produce ethanol.In the past this has been done by direct potentiometric measurement using a fluoride-selective electrode (F ISE), an ion meter and certified NaF standards. The sodium fluoride level was determined manually by dipping the electrode directly into the blood sample. Results were recorded manually. This poster describes two independent automated methods of analysis that allow the minimization of this tedious and time-consuming procedure.In the first one, the fluoride content in a blood aliquot is measured by direct potentiometric measurement after the addition of TISAB and deionized water. The second method employs the titration of the sample aliquot with La(NO3)3 after adding a buffer solution.
- AN-T-223Analysis of electroplating baths
Electroplating processes are used in several different industry sectors to protect the surface quality of various products against corrosion or abrasion and significantly improve their working life. It is essential to check the bath composition on a regular basis to ensure that the process is operating correctly. Typical examples of electroplating baths include alkaline degreasing baths or acidic or alkaline baths containing metals e.g. copper, nickel, or chromium, or components like chloride and cyanide. It is crucial that the chosen analysis technique fulfills high safety standards for these kinds of analyses and produces reliable results. The OMNIS Sample Robot system automatically pipettes and analyzes aggressive electroplating bath samples on different workstations, increasing the safety in the lab. This provides more reliable results in comparison to manual titration and is more time efficient as different parameters can be analyzed in parallel.
- WP-061Moisture in petroleum products according to ASTM D6304
Knowledge of the water content in lubricating oils, additives, and similar products is important in the manufacturing, purchase, sale, or transfer of petroleum products to help estimate their quality and performance characteristics. Monitoring the water content in such products can prevent damage to infrastructure and ensure safe operation by avoiding corrosion processes and subsequent engine wear. This White Paper explains the easy determination of moisture in petroleum samples by coulometric Karl Fischer titration according to the three procedures outlined in ASTM Method D6304. A comparison is given between the procedures to determine which is most suitable for different sample types.
- AB-177Automatic determination of the bromine number and the bromine index in petroleum products
The bromine number and bromine index are important quality control parameters for the determination of aliphatic C=Cdouble bonds in petroleum products. Both indices provide information on the content of substances that react withbromine. The difference between the two indices is that the bromine number indicates the consumption of bromine in gfor 100 g sample and the bromine index in mg for 100 g sample.This Application Bulletin describes the determination of the bromine number according to ASTM D1159, ISO 3839, BS2000-130, IP 130, GB/T 11135 and DIN-51774-1. The bromine index determination for aliphatic hydrocarbons is described according to ASTM D2710, IP 299, GB/T 11136 and DIN 51774-2. For aromatic hydrocarbons the determination of the bromine index is described according to ASTM D5776 and SH/T 1767. UOP 304 is not recommended for the determination of the bromine number or bromine index because its titration solvent contains mercuric chloride.
- AN-H-086Determination of sodium in potato chips
Titration of an unfiltered suspension of the sample with a standardized solution of aluminum containing a stoichiometric excess of potassium ions in the presence of ammonium hydrogen difluoride at ~ pH 3 to give an exothermic reaction, forming insoluble NaK2AlF6. The titrant is standardized against a solution prepared from anhydrous sodium sulfate or sodium carbonate. In addition to this application note, you can find more information on thermometric sodium determination in foods in our application video available on YouTube: https://youtu.be/lnCp9jBxoEs
- AN-I-034Investigation of nucleation processes with automated titrators
This Application Note covers the formation of calcium carbonate from solution.
- AN-T-219pH value and TTA in flour, dough, and bread
In order to consistently manufacture high quality baked goods, it is critical to measure the pH value and acidity content in the raw materials and during the production steps. These factors have a major influence on the taste and storage lifetime of the final product. Consistent product quality is only possible with precise measurements during the process.This Application Note describes the measurement of pH value and the total titratable acidity in flour, dough, and bread using the Eco Titrator from Metrohm.
- AN-T-244Standardization of sodium thiosulfate
The OMNIS Titrator equipped with a Pt Titrode accurately and reliably determines titer concentration even in diluted titrants as shown in this Application Note.
- AN-T-179Fully automated determination of TAN/TBN according to ASTM D664 and ASTM D2896
Fully automated determination of the total acid number and total base number in engine oils according to ASTM D664 and ASTM D2896 is possible with the OMNIS Titrator.
- AN-T-220Sodium chloride content in dough and bread
If consumed in excess, sodium may damage the cardiovascular system. It is therefore in the interest of food manufacturers to reduce the salt content and while preserving the flavor of the food.To ensure consistent quality, it is critical to know the exact salt content in the raw materials and the final products. This is only possible by performing precise measurements during the production process.This Application Note explains the determination of sodium chloride in dough and bread quickly according to AOAC 971.27 with the Eco Titrator equipped with an Ag Titrode.
- AN-T-102Standardization of hydrochloric acid with TRIS
Titrants are normally bought ready to use. However, it is necessary to determine the accurate concentration of your titrant solution on a regular basis using a primary standard. To correct the mentioned variation, a so-called «titer factor» is applied. The titer can be easily and quickly assessed by using the Metrohm brand of autotitrators. Predefined calculation formulas implemented in Metrohm titrators or software, respectively, as well as the automatic storage of the titer factor, makes standardization a simple task.
- AN-H-088Automated determination of total acid number (TAN) in oils
Automated determination of total acid number (TAN) in new and used lubricating oils and crude oils using the 814 USB Sample Processor. Dissolve oil sample in mixture of toluene and 2-propanol, add paraformaldehyde and titrate with 0.1 mol/L or 0.01 mol/L KOH in propan-2-ol. The endpoint is indicated by an endothermic response caused by the base-catalyzed depolymerization of paraformaldehyde.Reference: 1. M. J. D. Carneiro, M. A. Feres Júnior, and O. E. S. Godinho. Determination of the acidity of oils using paraformaldehyde as a thermometric end-point indicator. J. Braz. Chem. Soc. 13 (5) 692-694 (2002)
- AN-T-222Sulfur dioxide content in traditional Chinese medicines
Traditional Chinese medicine (TCM) remedies are gaining popularity in other cultures. In some TCM, sulfur dioxide (SO2) is used as a preservative, antioxidant, and disinfectant. The products are treated by sulfurization with SO2 gas. However, sulfur dioxide is a very poisonous gas. Global health authorities have set strict limits for the content of SO2 in products. It is therefore of crucial importance to determine the sulfur dioxide content to comply with these limits. In this well-suited method, the SO2 content in different natural TCM products are analyzed reliably and accurately according to ISO 22590 using the Eco Titrator equipped with an Optrode and sodium hydroxide as titrant.
- AB-100Biamperometric determination of potassium and/or ammonium
The potassium (or ammonium) ion is precipitated with sodium tetraphenyl borate, and the excess of this reagent back-titrated against the thallous(I) ion, using biamperometric endpoint detection. Ammonium can either be titrated together in an acid solution, or driven off by previous boiling in an alkaline solution. Methods are given for determining potassium in the presence of large excesses of sodium, ammonium, calcium, and magnesium.
- AN-T-085Photometric determination of sulfate
This Application Note describes the photometric determination of sulfate using the Optrode (610 nm). Sulfate is titrated with a lead nitrate solution; dithizone is used as indicator.
- AN-H-104Determination of free acid content of hydrometallurgical leach liquors
A measured amount of acidic hydrometallurgical leach liquor is treated with potassium oxalate solution to mask potential interference from Fe(III) and other metal ions, and then titrated with standard 1 mol/L NaOH solution.
- AN-T-116Automatic sulfate determination in aqueous solution using a combined ion-selective calcium electrode (Ca ISE)
This Application Note describes automatic sulfate determination using a combined ion-selective calcium electrode. Sulfate is precipitated with an excess of barium chloride solution. Excess barium is subsequently back-titrated with a standard EGTA solution.
- AN-H-107Determination of ferrous ion content in hydrometallurgical leach liquors
A measured amount of acidic hydrometallurgical leach liquor is further acidified with sulfuric acid, prior to being titrated with standard potassium dichromate solution to an exothermic endpoint. Thus, 1 mol K2Cr207 ≡ 6 mol Fe2+.
- AN-T-077Photometric determination of sulfate in aqueous solutions
This Application Note describes the photometric determination of sulfate in aqueous solutions using the Optrode (520 nm). Sulfate is precipitated with an excess of barium chloride solution. Excess barium is subsequently titrated with EDTA.
- AN-H-101Determination of the water content of mineral acids
A sample of concentrated mineral acid is dissolved in anhydrous acetonitrile, and the water content titrated with a solution of TEOF in acetonitrile. The TEOF reacts exothermically with water in the presence of a strong acid (acting as a catalyst).
- AN-T-197Surface glass test according to USP<660>
The surface glass test for hydrolytic resistance combined with the glass grains test determines the glass type. The hydrolytic resistance is determined by the quantity of alkali released from the glass under specified conditions. The released alkali is then titrated with hydrochloric acid to a pH value of 5.5.