Combined Ag ring electrode
6.00450.100
Combined Ag ring electrode
en
6.00450.100
Prezentare generală a caracteristicilor
Combined silver ring electrode with fixed ground-joint diaphragm.
This electrode is suitable for precipitation titrations when the pH value varies (titrant silver nitrate) of, e.g.:
- Chloride, bromide, iodide
- Sulfides
- Hydrogen sulfide
- Mercaptans
- Cyanides
The fixed ground-joint diaphragm is insensitive to contamination and the permanently fused-in silver ring is resistant to more highly concentrated acids and saline solutions.
c(KNO3) = 1 mol/L is used as reference electrolyte and storage solution.
Depending on the application, we recommend using an Ag ring electrode with a coating (AgBr, AgCl or Ag2S coating), which can be ordered accordingly.
Specificații tehnice
| Shaft material | Glass |
|---|---|
| Measuring range (theoretical) | -2000...2000 |
| Measuring unit | mV |
| Temperature range, long-term (°C) | 0...70 |
| Temperature range, short-term (°C) | 0...70 |
| pH range | 0...14 |
| Max. installation length (mm) | 125 |
| SGJ sleeve | flexible |
| Shaft diameter top (mm) | 12 |
| Shaft diameter bottom (mm) | 6 |
| Min. immersion depth (mm) | 15 |
| Electrode plug-in head | Metrohm plug-in head G |
| Indicator electrode type | Ag |
| Indicator electrode shape | Ring |
| Diaphragm | Fixed ground-joint diaphragm |
| Reference electrolyte type | c(KNO3) = 1 mol/L |
| Electrolyte flow rate (μl/h) at 10 cm water column | 10...25 |
| Reference system | LL system |
-
- Sleeve with SGJ 14/12 mm
- 6.1236.050
- Sleeve with SGJ 14/12 mm, polyethylene.
- Sleeve with SGJ 14/12 mm, polyethylene.
- PCS
- 1
- Storage vessel
- 6.2008.040
- Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
- <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
- PCS
- 1
-
- Sleeve with SGJ 14/12 mm
- 6.1236.050
- Sleeve with SGJ 14/12 mm, polyethylene.
- Sleeve with SGJ 14/12 mm, polyethylene.
- PCS
- 1
- Storage vessel
- 6.2008.040
- Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
- <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
- PCS
- 1
-
- Electrode cable plug-in head G / plug P, 0.55 m
- 6.02104.000
- Cable for connecting an analog electrode (plug-in head G) to an analog measuring module from OMNIS.
- <p>Cable for connecting an analog electrode (plug-in head G) to an analog measuring module from OMNIS.</p>
- PCS
- 1
- Electrode cable plug-in head G / plug P, 1.5 m
- 6.02104.010
- Cable for connecting an analog electrode (plug-in head G) to an analog measuring module from OMNIS.
- <p>Cable for connecting an analog electrode (plug-in head G) to an analog measuring module from OMNIS.</p>
- PCS
- 1
- Electrode cable / 1 m / F
- 6.2104.020
- For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
- For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
- PCS
- 1
- Electrolyte KNO3-1mol/L 250 mL
- 6.2310.010
- Electrolyte solution KNO3 1 M (reference electrolyte for combined silver electrodes)
- Electrolyte solution KNO<SUB>3</SUB> 1 M (reference electrolyte for combined silver electrodes)
- PCS
- 1