You have been redirected to your local version of the requested page
Combined Ag ring electrode

Combined Ag ring electrode

6.00450.100

Combined Ag ring electrode

en

6.00450.100

Prezentare generală a caracteristicilor

Combined silver ring electrode with fixed ground-joint diaphragm.
This electrode is suitable for precipitation titrations when the pH value varies (titrant silver nitrate) of, e.g.:
 

  • Chloride, bromide, iodide
  • Sulfides
  • Hydrogen sulfide
  • Mercaptans
  • Cyanides

 

The fixed ground-joint diaphragm is insensitive to contamination and the permanently fused-in silver ring is resistant to more highly concentrated acids and saline solutions.

c(KNO3) = 1 mol/L is used as reference electrolyte and storage solution.

Depending on the application, we recommend using an Ag ring electrode with a coating (AgBr, AgCl or Ag2S coating), which can be ordered accordingly.

 

Specificații tehnice

Shaft materialGlass
Measuring range (theoretical)-2000...2000
Measuring unitmV
Temperature range, long-term (°C)0...70
Temperature range, short-term (°C)0...70
pH range0...14
Max. installation length (mm)125
SGJ sleeveflexible
Shaft diameter top (mm)12
Shaft diameter bottom (mm)6
Min. immersion depth (mm)15
Electrode plug-in headMetrohm plug-in head G
Indicator electrode typeAg
Indicator electrode shapeRing
DiaphragmFixed ground-joint diaphragm
Reference electrolyte typec(KNO3) = 1 mol/L
Electrolyte flow rate (μl/h) at 10 cm water column10...25
Reference systemLL system
This field is required.
    • Sleeve with SGJ 14/12 mm
    • 6.1236.050
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • PCS
    • 1
    • Storage vessel 
    • 6.2008.040
    • Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
    • <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
    • PCS
    • 1
    • Sleeve with SGJ 14/12 mm
    • 6.1236.050
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • PCS
    • 1
    • Storage vessel 
    • 6.2008.040
    • Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
    • <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
    • PCS
    • 1
    • Electrode cable plug-in head G / plug P, 0.55 m
    • 6.02104.000
    • Cable for connecting an analog electrode (plug-in head G) to an analog measuring module from OMNIS.
    • <p>Cable for connecting an analog electrode (plug-in head G) to an analog measuring module from OMNIS.</p>
    • PCS
    • 1
    • Electrode cable plug-in head G / plug P, 1.5 m
    • 6.02104.010
    • Cable for connecting an analog electrode (plug-in head G) to an analog measuring module from OMNIS.
    • <p>Cable for connecting an analog electrode (plug-in head G) to an analog measuring module from OMNIS.</p>
    • PCS
    • 1
    • Electrode cable / 1 m / F
    • 6.2104.020
    • For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
    • For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
    • PCS
    • 1
    • Electrolyte KNO3-1mol/L 250 mL
    • 6.2310.010
    • Electrolyte solution KNO3 1 M (reference electrolyte for combined silver electrodes)
    • Electrolyte solution KNO<SUB>3</SUB> 1 M (reference electrolyte for combined silver electrodes)
    • PCS
    • 1