Modelos
Modelos (3)Aplicações
Aplicações (14)Accessories para 945
Peças de reposição (1)Software para 945
Software (1)Manuais & Folhetos para 945
Documentos (6)Inspirando insights do setor para 945
Perspectivas do setor (5)Notícias para 945
Notícias (1)2.945.0010
945 Professional Detector Vario – ConductivityIntelligent stand-alone detector equipped with a high-performance IC Conductivity Detector. For use with intelligent IC instruments or as independent conductivity detector.
2.945.0020
945 Professional Detector Vario – AmperometryIntelligent stand-alone detector equipped with the IC Amperometric Detector. Outstanding selectivity due to the four measuring modes: DC, PAD, flexIPAD, CV. The excellent signal/noise ratio and the very fast start-up guarantee the highest in measurement precision. For use with intelligent IC instruments or as independent detector.
2.945.0030
945 Professional Detector Vario – Conductivity & AmperometryIntelligent stand-alone detector equipped with the high performance IC Conductivity Detector and the IC Amperometric Detector, with the four measuring modes DC, PAD, flexIPAD and CV. For use with intelligent IC instruments or as independent detector for conductivity and amperometric detection.
- AN-P-087Quality labels for novel foods
This Application Note presents an update to the standard AOAC method for total GOS determination in foodstuffs.
- AN-BAT-016EIS at different states of charge with INTELLO
This application shows how EIS, combined with INTELLO and NOVA, tracks changes in internal battery resistance across SOC levels to study performance and aging mechanisms.
- AN-C-197Potassium assay in potassium citrate and citric acid oral solution
Potassium citrate and citric acid oral solutions act as systemic alkalizers. Potassium assays, validated per USP <621> and <1225>, use IC with L76 cation-exchange columns.
- AN-C-198Calcium acetate assay in calcium acetate capsules
The assay of calcium acetate, often used as a phosphate binder for dialysis patients, can be performed with ion chromatography (IC) as per USP <621> and <1225>.
- AN-CS-021Sodium in sodium bicarbonate and sodium phosphates compounded injections
Compounded injections of sodium bicarbonate are sterile solutions for correcting metabolic acidosis and other conditions requiring systemic alkalinization. Compounded injections of sodium phosphates serve as a phosphate source to either prevent or correct hypophosphatemia in patients with restricted oral intake. Ion chromatography (IC) with suppressed conductivity detection is the standardized way to accurately quantify sodium in these solutions.
- AN-FLU-002Understanding the mechanism of a bioassay indicator by fluorescence
Alamar Blue is monitored with fluorescence spectroelectrochemistry during its irreversible reduction to resorufin and further reversible reduction to dihydroresorufin.
- AN-NIR-022Quality Control of Gasoline
In recent years, there has been a significant push to reduce the environmental impacts of fuels through improvements to fuel quality. The determination of key quality parameters of gasoline, namely research octane number (RON, ASTM D2699-19), motor octane number (MON, ASTM D2700-19), anti knock index (AKI), aromatic content (ASTM D5769-15), and density, conventionally requires several different analytical methods, which are laborious and need trained personnel. This application note demonstrates that the XDS RapidLiquid Analyzer, operating in the visible and near-infrared spectral region (Vis-NIR), provides a cost-efficient and fast solution for the multiparameter analysis of gasoline.
- AN-S-375Fluoride in sodium fluoride for pharmaceutical use
Dental care products often contain sodium fluoride as an active ingredient. Manufacturers use the United States Pharmacopeia and National Formulary (USP-NF) Monograph «Sodium Fluoride» to quantify sodium fluoride and its anionic contaminants chloride and acetate in these products. The validated USP method proposes ion chromatography (IC) with suppressed conductivity detection to carry out the fluoride assay as well as the impurity determination in a single chromatogram.
- AN-S-376Fluoride in sodium fluoride gel for pharmaceutical use
Sodium fluoride gel for pharmaceutical use needs to comply with USP requirements. The actual monograph (USP 42) uses two different methods for the identification and the assay. Ion chromatography allows the analysis of these two parameters in one single determination. In the course of the USP monograph modernization, this ion chromatographic approach makes this type of analysis even easier.
- AN-S-379Fluoride in sodium fluoride tablets for pharmaceutical use
Sodium fluoride tablets for pharmaceutical use need to comply with U.S. Pharmacopeia (USP) requirements. Ion chromatography (IC) with suppressed conductivity detection has been approved by the USP as a validated method to quantify fluoride content in sodium fluoride tablets. In the course of the USP monograph modernization, using automated IC makes this type of analysis even easier.
- AN-S-380Monofluorophosphate and fluoride in sodium monofluorophosphate for pharmaceutical use
Ion chromatography (IC) with suppressed conductivity detection has been approved by the U.S. Pharmacopeia (USP) as a validated method to quantify the monofluorophosphate (MFP) content in sodium monofluorophosphate. This Application Note shows that all acceptance criteria for the USP Monograph «Sodium Monofluorophosphate» are fulfilled and the procedure was approved as a validated USP method.
- AN-S-397IC assay for sodium chloride in sodium chloride tablets for solution
As an alternative to titration, ion chromatography (IC) with suppressed conductivity detection has been approved by USP as validated method to quantify chloride content in NaCl tablets for solution or oral use.
- AN-S-399IC assay for fluoride in sodium fluoride and acidulated phosphate topical solution
Anticavity pharmaceuticals like sodium fluoride and acidulated phosphate topical solution products require strict quality control. This Application Note outlines the fluoride IC assay as described in the USP Monograph Sodium Fluoride and Acidulated Phosphate Topical Solution.
- AN-S-403Anions in lithium-ion battery solvents
N-Methylpyrrolidone (NMP) is crucial for lithium-ion battery production. Metrohm’s intelligent Preconcentration Technique with Matrix Elimination enables µg/L-level anion analysis in NMP.
- 26 de fev. de 2024Garantir e certificar a qualidade e a conformidade em ambientes regulamentados
Os instrumentos certificados pela AOAC Installation & Operational Qualification (Q2) da Metrohm proporcionam tranquilidade ao simplificar o processo de atendimento aos requisitos regulatórios.
- 14 de set. de 2020História do Metrohm IC – Parte 3
Postagem no blog sobre cromatografia iônica Metrohm e a introdução da supressão sequencial para aumentar a sensibilidade na análise cromatográfica iônica.
- 18 de nov. de 2024Cromatografia iônica para a indústria farmacêutica
Os princípios da cromatografia iônica são introduzidos, depois algumas aplicações e benefícios do uso de CI para análise farmacêutica de acordo com o Capítulo Geral da USP <1065>.
- 16 de out. de 2023Aplicação de métodos validados pela USP para equivalência de colunas de separação
A modernização das Monografias da USP permite agora uma seleção mais ampla de colunas de separação para análises farmacêuticas utilizando cromatografia iônica (CI). Os estudos de equivalência de colunas permitem o uso de colunas analíticas alternativas sem a necessidade de procedimentos complicados de validação de métodos. Isto beneficia os pesquisadores farmacêuticos, economizando tempo e esforço, mantendo a precisão e a confiabilidade dos resultados analíticos de acordo com métodos validados.
- 25 de mai. de 2020Titulação complexométrica fotométrica
- 8.945.50018.945.5001Brochure: 945 Professional Detector Vario IC Amperometric Detector – Amperometric detection for the determination of electroactive substances
Amperometric detectors are an alternative to conductivity and UV/VIS detectors. They are used when electroactive – i.e. oxidizable or reducible – substances are to be determined. The amperometric detector exists as an embedded detector – the IC Amperometric Detector – and as a stand-alone detector – the 945 Professional Detector Vario. The present brochure describes these two instruments
English
Outros idiomas
- 8.945.30048.945.3004Declaration of Conformity for 945 Professional Detector Vario
English
Outros idiomas
- 8.945.80018.945.8001Manual for 29450010 Professional Detector Vario Cond
English
Outros idiomas
- 8.945.80028.945.8002Manual for 29450020 Professional Detector Vario Amp
English
Outros idiomas
- 8.945.80038.945.8003Manual for 29450030 Professional Detector Vario Conductivity & Amperometry
English
Outros idiomas
- 8.894.50038.894.5003Brochure: 894 Professional CVS
This brochure presents the 894 Professional CVS portfolio, including automation and the viva software.
English