Metrosep Carb 2 - 250/2.0

Metrosep Carb 2 - 250/2.0

6.01090.230

Metrosep Carb 2 - 250/2.0

en

6.01090.230

Visão geral

The Metrosep Carb 2 - 250/2.0 IC column is particularly suitable for the determination of carbohydrates using alkaline eluents and pulsed amperometric detection. The high-capacity anion exchanger column is based on a styrene-divinylbenzene copolymer. It is stable in the range of pH = 0 - 14 and separates monosaccharides and disaccharides. It is also suitable for the analysis of sugar alcohols, anhydrous sugars, amino sugars, etc. The 250 mm Microbore version of the Metrosep Carb 2 separation column is optimized for complex separations.

Thanks to its low eluent consumption, it is particularly suitable for IC-MS coupling.

Especificações técnicas

Housing materialPEEK
Carrier materialPolystyrene-divinylbenzene copolymer with quaternary ammonium groups
Particle size5.0 µm
Standard flow0.13 mL/min
Maximum pressure20 MPa
Maximum flow0.30 mL/min
pH range0–14
Column dimensions 250 x 2.0 mm
Temperature range20–60 °C
Standard temperature 30 °C

Cromatograma

  • Cromatograma
  • Cromatograma
This field is required.
    • Threaded stopper
    • 6.2744.060
    • For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.
    • <p>For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.</p>
    • PCS
    • 2
    • Threaded stopper
    • 6.2744.060
    • For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.
    • <p>For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.</p>
    • PCS
    • 2
    • Metrosep Carb 2 Guard/2.0
    • 6.01090.600
    • The Metrosep Carb 2 Guard/2.0 microbore guard column effectively removes contaminations, thus protecting the analytical separation column. The design of the guard column has been selected in such a way that its influence on the chromatographic separation can be ignored.
    • <p>The Metrosep Carb 2 Guard/2.0 microbore guard column effectively removes contaminations, thus protecting the analytical separation column. The design of the guard column has been selected in such a way that its influence on the chromatographic separation can be ignored.</p>
    • PCS
    • 1
    • PEEK capillary, 0.18 mm ID / 2 m
    • 6.01806.000
    • For use in the high-pressure flow path, e.g. as preheating capillary for Metrosep Carb 2 columns in the 2 mm version (6.01090.2x0).
    • <p>For use in the high-pressure flow path, e.g. as preheating capillary for Metrosep Carb 2 columns in the 2 mm version (6.01090.2x0).</p>
    • PCS
    • 1
    • Metrosep BO3 Trap 1 - 100/4.0
    • 6.1015.200
    • Trap column for the removal of borate contaminants from the eluent. The Metrosep BO3 Trap 1 - 100/4.0 is used mainly in carbohydrate analysis with hydroxide eluents.
    • <p>Trap column for the removal of borate contaminants from the eluent. The Metrosep BO<sub>3</sub> Trap 1 - 100/4.0 is used mainly in carbohydrate analysis with hydroxide eluents.</p>
    • PCS
    • 1
    • Metrosep CO3 Trap 1 - 100/4.0
    • 6.1015.300
    • Trap column for the removal of carbonate traces in hydroxide eluents.
    • <p>Trap column for the removal of carbonate traces in hydroxide eluents.</p>
    • PCS
    • 1