Metrosep Carb 2 - 150/2.0
6.01090.220
Metrosep Carb 2 - 150/2.0
en
6.01090.220
Visão geral
The Microbore version of the Metrosep Carb 2 - 150/2.0 IC column is particularly suitable for the determination of carbohydrates using alkaline eluents and pulsed amperometric detection. The anion exchanger column is based on a styrene-divinylbenzene copolymer. It is stable in the range of pH = 0 to pH = 14 and separates monosaccharides and disaccharides. It is also suitable for the analysis of sugar alcohols, anhydrous sugars, oligosaccharides, etc. The column capacity has been optimized to enable the combination of rapid separations and excellent separation properties.
Thanks to its low eluent consumption, it is particularly suitable for IC-MS coupling.
Especificações técnicas
| Housing material | PEEK |
|---|---|
| Carrier material | Polystyrene-divinylbenzene copolymer with quaternary ammonium groups |
| Particle size | 5.0 µm |
| Standard flow | 0.13 mL/min |
| Maximum pressure | 20 MPa |
| Maximum flow | 0.45 mL/min |
| pH range | 0–14 |
| Column dimensions | 150 x 2.0 mm |
| Temperature range | 20–60 °C |
| Standard temperature | 30 °C |
Cromatograma
-
- Threaded stopper
- 6.2744.060
- For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.
- <p>For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.</p>
- PCS
- 2
-
- Threaded stopper
- 6.2744.060
- For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.
- <p>For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.</p>
- PCS
- 2
-
- Metrosep Carb 2 Guard/2.0
- 6.01090.600
- The Metrosep Carb 2 Guard/2.0 microbore guard column effectively removes contaminations, thus protecting the analytical separation column. The design of the guard column has been selected in such a way that its influence on the chromatographic separation can be ignored.
- <p>The Metrosep Carb 2 Guard/2.0 microbore guard column effectively removes contaminations, thus protecting the analytical separation column. The design of the guard column has been selected in such a way that its influence on the chromatographic separation can be ignored.</p>
- PCS
- 1
- PEEK capillary, 0.18 mm ID / 2 m
- 6.01806.000
- For use in the high-pressure flow path, e.g. as preheating capillary for Metrosep Carb 2 columns in the 2 mm version (6.01090.2x0).
- <p>For use in the high-pressure flow path, e.g. as preheating capillary for Metrosep Carb 2 columns in the 2 mm version (6.01090.2x0).</p>
- PCS
- 1
- Metrosep BO3 Trap 1 - 100/4.0
- 6.1015.200
- Trap column for the removal of borate contaminants from the eluent. The Metrosep BO3 Trap 1 - 100/4.0 is used mainly in carbohydrate analysis with hydroxide eluents.
- <p>Trap column for the removal of borate contaminants from the eluent. The Metrosep BO<sub>3</sub> Trap 1 - 100/4.0 is used mainly in carbohydrate analysis with hydroxide eluents.</p>
- PCS
- 1
- Metrosep CO3 Trap 1 - 100/4.0
- 6.1015.300
- Trap column for the removal of carbonate traces in hydroxide eluents.
- <p>Trap column for the removal of carbonate traces in hydroxide eluents.</p>
- PCS
- 1