Hamilton RCX-30 - 250/4.6

Hamilton RCX-30 - 250/4.6

6.1018.000

Hamilton RCX-30 - 250/4.6

en

6.1018.000

Visão geral

The Hamilton RCX-30 - 250/4.6 is a column for separating monosaccharides, disaccharides and sugar alcohols. It is an anion exchange column based on polystyrene-divinylbenzene resin. The RCX-30 - 250/4.6 can be used for universal applications.

The Hamilton RCX-30 - 250/4.6 separation column exhibits an outstanding separation of fructose and lactose. The column also offers the advantage that flows of up to 2 mL/min can be used in order to accelerate the chromatography. The long version of the column (250 mm) is preferred for the determination of small carbohydrates (monosaccharides, disaccharides and sugar alcohols).

Especificações técnicas

Housing materialPEEK
Carrier materialStyrene-divinylbenzene copolymer
Particle size7 µm
Standard flow1.0 mL/min
Maximum pressure34 MPa
Maximum flow2.0 mL/min
pH range1–13 (T > 35°C max. pH 8)
Column dimensions 250 x 4.6 mm
Temperature range20–60 °C

Cromatograma

  • Cromatograma
  • Cromatograma
    • Metrosep RP 2 Guard/3.5
    • 6.1011.030
    • The Metrosep RP 2 Guard/3.5 is a guard column for universal use. It reliably protects the analytical separation column against contaminations. It reliably protects the analytical separation column against contamination, removing the smallest particles, traces of iron oxide and bacteria. The Metrosep RP 2 Guard/3.5 helps to reduce costs; its filter disk can be replaced very easily.
    • <p>The Metrosep RP 2 Guard/3.5 is a guard column for universal use. It reliably protects the analytical separation column against contaminations. It reliably protects the analytical separation column against contamination, removing the smallest particles, traces of iron oxide and bacteria. The Metrosep RP 2 Guard/3.5 helps to reduce costs; its filter disk can be replaced very easily.</p>
    • PCS
    • 1
    • Metrosep RP 3 Guard HC/4.0
    • 6.1011.040
    • The Metrosep RP 3 Guard HC/4.0 is a guard column for universal use. It reliably protects the analytical separation column against contamination, securely removing lipophilic organic contamination, the smallest particles, traces of iron oxide and bacteria. The guard column is based on a polymer material and thanks to its larger pack volume, has a significantly higher capacity that the Metrosep RP 2Guard/3.5. It can be used throughout the entire pH range.
    • <p>The Metrosep RP 3 Guard HC/4.0 is a guard column for universal use. It reliably protects the analytical separation column against contamination, securely removing lipophilic organic contamination, the smallest particles, traces of iron oxide and bacteria. The guard column is based on a polymer material and thanks to its larger pack volume, has a significantly higher capacity that the Metrosep RP 2Guard/3.5. It can be used throughout the entire pH range.</p>
    • PCS
    • 1