Combined Sb electrode. This electrode is well suited for pH titrations in:
 

  • matrices containing hydrofluoric acid
  • strongly hygroscopic matrices
     

Thanks to the robust/break-proof plastic shaft made of polypropylene, this electrode is mechanically resistant.

Especificações técnicas

Shaft materialNoryl/PP
Measuring range (theoretical)-2000...2000
Measuring unitmV
Temperature range, long-term (°C)0 ... 70
Temperature range, short-term (°C)0 ... 70
pH range2 ... 11
Max. installation length (mm)113
SGJ sleeveFlexible SGJ sleeve
Shaft diameter top (mm)12
Shaft diameter bottom (mm)12
Min. immersion depth (mm)10
Electrode plug-in headMetrohm plug-in head G
Indicator electrode typeSb rod
Internal reference electrode typeLL system
DiaphragmCeramic diaphragm
Reference electrolyte typec(KCl) = 3 mol/L
Electrolyte flow rate (μl/h) at 10 cm water column3 ... 10
Reference systemLL system
Resistance (kOhm)5
Diaphragm resistance (kOhm)1.2 ... 1.8
Este campo é obrigatório.
    • Sleeve with SGJ 14/12 mm
    • 6.1236.050
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • PCS
    • 1
    • Storage vessel 
    • 6.2008.040
    • Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
    • <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
    • PCS
    • 1
    • Polishing set for solid-state electrodes
    • 6.2802.000
    • Polishing set with 1 polishing cloth and about 2 g aluminum oxide powder (grain size 0.3 µm)
    • Polishing set with 1 polishing cloth and about 2 g aluminum oxide powder (grain size 0.3 µm)
    • PCS
    • 1
    • Sleeve with SGJ 14/12 mm
    • 6.1236.050
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • PCS
    • 1
    • Storage vessel 
    • 6.2008.040
    • Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
    • <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
    • PCS
    • 1
    • Polishing set for solid-state electrodes
    • 6.2802.000
    • Polishing set with 1 polishing cloth and about 2 g aluminum oxide powder (grain size 0.3 µm)
    • Polishing set with 1 polishing cloth and about 2 g aluminum oxide powder (grain size 0.3 µm)
    • PCS
    • 1
    • Electrode cable / 1 m / F
    • 6.2104.020
    • For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
    • For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
    • PCS
    • 1
    • Electrolyte 3 mol/L KCl (250 mL)
    • 6.2308.020
    • Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
    • Electrolyte solution c(KCl) &#61; 3 mol/L, (for Ag/AgCl reference systems)
    • PCS