Foi redireccionado para a sua versão local da página solicitada.
Combined antimony electrode

Combined antimony electrode

6.0421.100

Combined antimony electrode

en

6.0421.100

Visão geral

Combined Sb electrode. This electrode is well suited for pH titrations in:
 

  • matrices containing hydrofluoric acid
  • strongly hygroscopic matrices
     

Thanks to the robust/break-proof plastic shaft made of polypropylene, this electrode is mechanically resistant.

Especificações técnicas

Shaft materialNoryl/PP
Measuring range (theoretical)-2000...2000
Measuring unitmV
Temperature range, long-term (°C)0 ... 70
Temperature range, short-term (°C)0 ... 70
pH range2 ... 11
Max. installation length (mm)113
SGJ sleeveFlexible SGJ sleeve
Shaft diameter top (mm)12
Shaft diameter bottom (mm)12
Min. immersion depth (mm)10
Electrode plug-in headMetrohm plug-in head G
Indicator electrode typeSb rod
Internal reference electrode typeLL system
DiaphragmCeramic diaphragm
Reference electrolyte typec(KCl) = 3 mol/L
Electrolyte flow rate (μl/h) at 10 cm water column3 ... 10
Reference systemLL system
Resistance (kOhm)5
Diaphragm resistance (kOhm)1.2 ... 1.8
This field is required.
    • Sleeve with SGJ 14/12 mm
    • 6.1236.050
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • PCS
    • 1
    • Storage vessel 
    • 6.2008.040
    • Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
    • <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
    • PCS
    • 1
    • Polishing set for solid-state electrodes
    • 6.2802.000
    • Polishing set with 1 polishing cloth and about 2 g aluminum oxide powder (grain size 0.3 µm)
    • Polishing set with 1 polishing cloth and about 2 g aluminum oxide powder (grain size 0.3 µm)
    • PCS
    • 1
    • Sleeve with SGJ 14/12 mm
    • 6.1236.050
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • PCS
    • 1
    • Storage vessel 
    • 6.2008.040
    • Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
    • <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
    • PCS
    • 1
    • Polishing set for solid-state electrodes
    • 6.2802.000
    • Polishing set with 1 polishing cloth and about 2 g aluminum oxide powder (grain size 0.3 µm)
    • Polishing set with 1 polishing cloth and about 2 g aluminum oxide powder (grain size 0.3 µm)
    • PCS
    • 1
    • Electrode cable / 1 m / F
    • 6.2104.020
    • For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
    • For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
    • PCS
    • 1
    • Electrolyte 3 mol/L KCl (250 mL)
    • 6.2308.020
    • Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
    • Electrolyte solution c(KCl) &#61; 3 mol/L, (for Ag/AgCl reference systems)
    • PCS
    • 1