Wyszukiwarka akcesoriów
DRP-RPROBE-VIS-NIR
Reflection probe VIS-NIRReflection probe VIS-NIR designed to perform reflection experiments.
DRP-TFIBER-VIS-NIR
Transmission fiber VIS-NIRTransmission fiber VIS-NIR designed to perform transmission experiments
DRP-VKITSPELECNIR
Instruments verification kit for SPELEC NIRKit for verifying the correct performance of SPELECNIR instrument. With this kit, you will be able to perform electrochemical and optical verification.
A660044277
NIRS Analyzer PRO Lamp 12V/20WReplacement lamp for the NIRS Analyzer Pro (12V/20W)
A649281190
NIRS XDS Process Contact Lamp 50W, 12 Volt- White leadReplacement lamp with contact for NIRS Process instruments. 50W, 12 Volt- White lead.
6.07410.000
OMNIS NIR LampSpare lamp for 2060 The NIR Analyzer and OMNIS NIR Analyzer with built-in hour counter.
6.7425.000
NIRS XDS irisIris for focusing mini sample vessels, reflection standard, various vials or a transflection vessel in the NIRS XDS RCA Analyzer, the NIRS XDS MasterLab Analyzer and the NIRS XDS MultiVial Analyzer
6.7400.010
NIRS Liquid Sample Kit TransflectionThe NIRS Liquid Sample Kit Transflection supplements the following instruments with the function of the transflection measurement of liquids:NIRS DS2500 Analyzer (order number: 2.922.0010); NIRS XDS MasterLab Analyzer (order number: 2.921.1310); NIRS XDS MultiVial Analyzer (order number: 2.921.1120); NIRS XDS RapidContent Analyzer (order number: 2.921.1110); NIRS XDS RapidContent Analyzer - Solids (order number: 2.921.1210);
6.7401.000
NIRS transflection vessel, optically flatOptically flat transflection vessel for the spectral measurement of liquids. Can be used in combination with the following instruments:NIRS DS2500 Analyzer (order number: 2.922.0010); NIRS XDS MasterLab Analyzer (order number: 2.921.1310); NIRS XDS MultiVial Analyzer (order number: 2.921.1120); NIRS XDS RapidContent Analyzer (order number: 2.921.1110); NIRS XDS RapidContent Analyzer - Solids (order number: 2.921.1210);
6.7450.000
NIRS reflection standard, set of 2Set of wavelength standard and 80% reflection standard for the calibration of an NIRS XDS MasterLab Analyzer, NIRS XDS RCA Analyzer, NIRS XDS MultiVial Analyzer, NIRS XDS SmartProbe Analyzer, NIRS XDS Interactance OptiProbe Analyzer and NIRS DS2500 Analyzer.
6.7450.010
NIRS reflection standard, set of 7Set comprised of six reflection standards and one wavelength standard for the calibration of an NIRS XDS MasterLab Analyzer, NIRS XDS RCA Analyzer, NIRS XDS MultiVial Analyzer, NIRS XDS SmartProbe Analyzer, NIRS XDS Interactance OptiProbe Analyzer and NIRS DS2500 Analyzer in regulated environments.
6.7450.020
NIRS tablet transmission standardNIRS transmission standard for the spectral measurement of tablets in the NIRS XDS MasterLab Analyzer
6.7450.040
NIRS transmission wavelength calibration standardTransmission wavelength calibration standard for NIRS XDS RLA Analyzer and NIRS XDS Transmission OptiProbe Analyzer
6.7402.020
NIRS disposable backs for 6.7402.030, 100 pcs.The disposable backs are used for the secure sealing of the mini sample cups. The sample cups are used in the following:NIRS DS2500 Analyzer (order number: 2.922.0010); NIRS XDS MasterLab Analyzer (order number: 2.921.1310); NIRS XDS RCA Analyzer (order number: 2.921.1110); NIRS XDS MultiVial Analyzer (order number: 2.921.1210); The package is comprised of 100 disposable backs.
6.7420.000
NIRS gold diffuse reflector, 1 mm total pathlengthGold diffuse reflector for the transflection measurement of liquids. Can be used in combination with the following instruments:NIRS DS2500 Analyzer (order number: 2.922.0010); NIRS XDS MasterLab Analyzer (order number: 2.921.1310); NIRS XDS MultiVial Analyzer (order number: 2.921.1120); NIRS XDS RapidContent Analyzer (order number: 2.921.1110); NIRS XDS RapidContent Analyzer - Solids (order number: 2.921.1210);
6.7420.010
NIRS gold diffuse reflector, 2 mm total pathlengthGold diffuse reflector for the transflection measurement of liquids. Can be used in combination with the following instruments:NIRS DS2500 Analyzer (order number: 2.922.0010); NIRS XDS MasterLab Analyzer (order number: 2.921.1310); NIRS XDS MultiVial Analyzer (order number: 2.921.1120); NIRS XDS RapidContent Analyzer (order number: 2.921.1110); NIRS XDS RapidContent Analyzer - Solids (order number: 2.921.1210);
6.7420.020
NIRS gold diffuse reflector, 4 mm total pathlengthGold diffuse reflector for the transflection measurement of liquids. Can be used in combination with the following instruments:NIRS DS2500 Analyzer (order number: 2.922.0010) NIRS XDS MasterLab Analyzer (order number: 2.921.1310) NIRS XDS MultiVial Analyzer (order number: 2.921.1120) NIRS XDS RapidContent Analyzer (order number: 2.921.1110) NIRS XDS RapidContent Analyzer - Solids (order number: 2.921.1210)
6.7400.030
NIRS DS2500 accessory kitAccessory kit for NIRS DS2500 Analyzer
6.7400.000
NIRS XDS accessory kitAccessory kit for NIRS XDS laboratory monochromators
6.7410.110
NIRS FlexiTrayThe NIRS FlexiTray permits maximum flexibility when analyzing tablets and capsules. A variety of forms are reproducibly positioned with the aid of the spring mechanism in order to ensure accurate and precise measurement results at all times.
6.7430.030
NIRS transmission pair calibration fixtureNIRS transmission pair calibration fixture
6.7410.000
NIRS XDS tray for reflection standardA reflection standard is required for the calibration of the monochromator with the sample module. A holder in which the standard is positioned is used to fasten the calibration standard in place. A reflection standard and its associated holder are required for:NIRS XDS MultiVial Analyzer (order number: 29211210); NIRS XDS MasterLab Analyzer (order number: 2.921.1310);
6.7430.050
Spare lamp for NIRS DS2500Spare lamp with 12.0 V and 35 W for NIRS DS2500 Analyzer
6.7402.030
NIRS mini sample cups, 10 pcs. including 100 disposable backsMini sample cup for the spectral recording of powders and granulates in reflection. The sample cup can be sealed with disposable backs in order to avoid sample loss and for the uniform distribution of the powder or granulate in the sample cup.The sample cups are used with the following instruments:NIRS DS2500 Analyzer (order number: 2.922.0010); NIRS XDS MasterLab Analyzer (order number: 2.921.1310); NIRS XDS MultiVial Analyzer (order number: 2.921.1120); NIRS XDS RapidContent Analyzer (order number: 2.921.1110); NIRS XDS RapidContent Analyzer - Solids (order number: 2.921.1210);
6.7430.000
NIRS XDS lab spare lampSpare lamp with 12 V and 50 W for the monochromator of the NIRS XDS laboratory instruments
6.7440.170
NIRS SingleFiber optical fiber, 2 mOne-channel optical fiber in 2 m length for NIRS Process Analyzers
6.7402.040
NIRS XDS coarse granular sample cellNIRS XDS coarse granular sample cell for the reflection measurement of samples with different surface properties.
6.7410.090
NIRS tablet tray for different tablet shapesNIRS tablet tray for different tablet shapes
6.7403.180
NIRS Spacer for 12.5 mm cuvettesThe NIRS Spacer for 12.5 mm cuvette set ensures spacers for an optimum position of the cuvette in the sample holder.
6.7430.010
NIRS XDS lab spare parts kitNIRS XDS spare parts kit of the lab instrument is comprised of two spare lamps, two fan filters and four fuses.
6.7410.010
NIRS MultiVial tray for 4x5 15 mm vialsNIRS MultiVial tray for 4x5 15 mm vials
6.7410.020
NIRS MultiVial tray for 3x5 19 mm vialsNIRS MultiVial tray for 3x5 19 mm vials
6.7410.030
NIRS MultiVial tray for 3x5 22 mm vialsNIRS MultiVial tray for 3x5 22 mm vials
6.7410.040
NIRS MultiVial tray for 2x3 27 mm vialsNIRS MultiVial tray for 2x3 27 mm vials
6.7410.050
NIRS MultiVial tray for 2x3 29 mm vialsNIRS MultiVial tray for 2x3 29 mm vials
6.7402.060
NIRS DS2500 large sample cup, 5 pcs.Set of five large sample cups for the spectral measurement of powders and granulates in reflection using the NIRS DS2500 Analyzer.
6.7450.030
Certified NIRS 99% reflection standard for laboratory sensorsCertified 99% reflection standard for calibration of an NIRS XDS SmartProbe Analyzer
6.7403.110
NIRS XDS spacer for 0.5 mm cuvettes (6.7401.110)Spacer for fixing open quartz cuvettes with 0.5 mm total pathlength in an NIRS XDS RLA Analyzer.
6.7450.070
NIRS 99% reflection and wavelength standard process, 1 inch diameterNIRS 99% reflection and wavelength standard for process instrument with 1 inch probe diameter
6.7401.040
NIRS XDS quartz cuvette, screw top, 20 mm pathlengthQuartz cuvette, screw top, with 20 mm pathlength for the recording of a spectrum of volatile liquids in transmission using an NIRS XDS RLA Analyzer.
6.7401.110
NIRS XDS quartz cuvette with open top, 0.5 mm pathlengthOpen quartz cuvette with 0.5 mm pathlength for the recording of a spectrum of liquids in transmission using an NIRS XDS RLA Analyzer.
6.7450.080
NIRS 99% reflection and wavelength standard for process instrument, 0.5 inch probe diameterNIRS 99% reflection and wavelength standard for process instrument, 0.5 inch probe diameter
6.7450.090
NIRS 99% reflection and wavelength standard for process instrument, 1 inch diameter, 45° bevelNIRS 99% reflection and wavelength standard for process instrument with 1 inch diameter and 45° angle
6.7401.330
NIRS 12.5 mm quartz cuvette flow 5 mmThe flow quartz cuvettes enable continuous monitoring, for example of tablet disintegration processes and reaction kinetics. The high pressure resistance and a special bubble capturing system make all measurements particularly easy.Windows made of quartz glass of maximum purity and homogeneity ensure a transmission of more than 80% in the wavelength range of 200 nm - 2,500 nm.A variety of pathlengths are available:0.5 mm pathlength and a volume = 175 μL (order number: 67401300)1 mm pathlength and a volume = 350 μL (order number: 67401310)2 mm pathlength and a volume = 700 μL (order number: 67401320)5 mm pathlength and a volume = 1,750 μL (order number: 67401330)10 mm pathlength and a volume = 3,500 μL (order number: 67401340)Dimensions h x l x w = 35 mm x 12.5 mm x 12.5 mmWindow height = 15 mmCompatible with the NIRS spacer for the XDS RapidLiquid Analyzer
6.7401.340
NIRS 12.5 mm quartz cuvette flow 10 mmThe flow quartz cuvettes enable continuous monitoring, for example of tablet disintegration processes and reaction kinetics. The high pressure resistance and a special bubble capturing system make all measurements particularly easy.Windows made of quartz glass of maximum purity and homogeneity ensure a transmission of more than 80% in the wavelength range of 200 nm - 2,500 nm.A variety of pathlengths are available:0.5 mm pathlength and a volume = 175 μL (order number: 67401300)1 mm pathlength and a volume = 350 μL (order number: 67401310)2 mm pathlength and a volume = 700 μL (order number: 67401320)5 mm pathlength and a volume = 1,750 μL (order number: 67401330)10 mm pathlength and a volume = 3,500 μL (order number: 67401340)Dimensions h x l x w = 35 mm x 12.5 mm x 12.5 mmWindow height = 15 mmCompatible with the NIRS spacer for the XDS RapidLiquid Analyzer
6.7401.320
NIRS 12.5 mm quartz cuvette flow 2 mmThe flow quartz cuvettes enable continuous monitoring, for example of tablet disintegration processes and reaction kinetics. The high pressure resistance and a special bubble capturing system make all measurements particularly easy.Windows made of quartz glass of maximum purity and homogeneity ensure a transmission of more than 80% in the wavelength range of 200 nm - 2,500 nm.A variety of pathlengths are available:0.5 mm pathlength and a volume = 175 μL (order number: 67401300)1 mm pathlength and a volume = 350 μL (order number: 67401310)2 mm pathlength and a volume = 700 μL (order number: 67401320)5 mm pathlength and a volume = 1,750 μL (order number: 67401330)10 mm pathlength and a volume = 3,500 μL (order number: 67401340)Dimensions h x l x w = 35 mm x 12.5 mm x 12.5 mmWindow height = 8.5 - 15 mmCompatible with the NIRS spacer for the XDS RapidLiquid Analyzer and the DS2500 holder for the DS2500 Liquid Analyzer.
6.07410.010
Dust protection cover OMNIS NIRDust protection cover for the OMNIS NIR Analyzer. Protects the Analyzer against dust and dirt for prolonged periods when not in use.
6.07401.010
Holder OMNIS NIR, cuvette, 1 mmCuvette holder for the OMNIS NIR Analyzer for 1 mm quartz cuvettes (6.7401.200).
6.07401.020
Holder OMNIS NIR, cuvette, 2 mmCuvette holder for the OMNIS NIR Analyzer for 2 mm quartz cuvettes (6.7401.210).
6.07401.030
Holder OMNIS NIR, cuvette, 5 mmCuvette holder for the OMNIS NIR Analyzer for 5 mm quartz cuvettes (6.7401.220).
6.07401.040
Holder OMNIS NIR, cuvette, 10 mmCuvette holder for the OMNIS NIR Analyzer for 10 mm quartz cuvettes (6.7401.230).
6.07401.050
Holder OMNIS NIR, vial, 2 mmVial Holder for the OMNIS NIR Analyzer for 2 mm disposable vials (6.7402.070).
6.07401.060
Holder OMNIS NIR, vial, 4 mmVial Holder for the OMNIS NIR Analyzer for 4 mm disposable vials (6.7402.250).
6.07401.070
Holder OMNIS NIR, vial, 8 mmVial Holder for the OMNIS NIR Analyzer for 8 mm disposable vials (6.7402.240).
6.07401.080
Holder OMNIS NIR, vial, 10 mmVial Holder for the OMNIS NIR Analyzer for 10 mm disposable vials (6.7402.100).
6.07401.100
Holder OMNIS NIR, flow-through cellsCuvette holder for the OMNIS NIR Analyzer for flow-through cells(6.7401.300; 6.7401.310; 6.7401.320; 6.7401.330; 6.7401.340).
6.07410.030
External standards OMNIS NIR, reflectionSet of 5 reflection standards and 1 wavelength standard for checking the wavelength accuracy, the photometric linearity, and the noise characteristics of the OMNIS NIR Analyzer in reflection mode.
6.07410.040
External standards OMNIS NIR, transmissionSet of 5 transmission standards and 1 wavelength standard for checking the wavelength accuracy, the photometric linearity, and the noise characteristics of the OMNIS NIR Analyzer in transmission mode.
6.07402.100
Large holder OMNIS NIR, 100 mmLarge holder for large sample vessel OMNIS NIR, 100 mm (6.07402.110).Permits unambiguous positioning of the sample vessel and the rotation of the sample vessel.
6.07402.200
Small holder OMNIS NIR, 60 mmSmall holder for small sample vessel OMNIS NIR, 60 mm (6.07402.210).Permits unambiguous positioning of the sample vessel and the rotation of the sample vessel.
DRP-REFLECELL-C
UV-Vis/NIR spectroelectrochemical cell for conventional electrodesCell for UV-Vis/NIR spectroelectrochemical measurements with conventional electrodes.
6.07402.210
Small cup OMNIS NIR, 60 mmSmall sample vessel for the spectra acquisition of powders and granulates in reflection at various sample positions.The glass bottom is made of resistant Gorilla® Glass.Compatible with:Small holder OMNIS NIR, 60 mm (6.07402.200);
6.07402.110
Large cup OMNIS NIR, 100 mmLarge sample vessel for the spectra acquisition of powders and granulates in reflection at various sample positions. The glass bottom is made of resistant Gorilla® Glass.Compatible with:Large holder OMNIS NIR, 100 mm (6.07402.100);
6.07402.120
Large lid OMNIS NIR, black, 100 mmLarge lid (black) for large sample vessel OMNIS NIR, 100 mm (6.07402.110) for the reduction of stray light and slight compression of the sample.
6.07402.220
Small lid OMNIS NIR, black, 60 mmSmall lid (black) for small sample vessel OMNIS NIR, 60 mm (6.07402.210) for the reduction of stray light and slight compression of the sample.
6.7440.480
NIRS Process, I/O Communication boxI/O Communication box for process instruments with 24 analog and 24 digital channels
6.7403.000
NIRS XDS spacer for disposable 8 mm vials (6.7402.000)Spacer for disposable glass vials with 8 mm diameter.
6.7403.010
NIRS XDS spacer for disposable 4 mm vials (6.7402.010)Spacer for disposable glass vials with 4 mm diameter
6.07402.300
Flexible holder OMNIS NIRFlexible holder with a variable diameter of up to 30 mm for the examination of samples in vials in reflection.
6.07402.260
Transflection vessel OMNIS NIR, 60 mmOptically flat transflection vessel for the spectral measurement of liquids.
6.07402.910
Small reflector OMNIS NIR, 1 mmReflector with a gap size of 1 mm (optical path length of 2 mm) for the transflection measurement of liquids.Suitable for disposable 28 mm reflection vials (6.7402.140).
6.07402.920
Small reflector OMNIS NIR, 2 mmReflector with a gap size of 2 mm (optical path length of 4 mm) for the transflection measurement of liquids. Suitable for disposable 28 mm reflection vials (6.7402.140).
6.07402.930
Small reflector OMNIS NIR, 4 mmReflector with a gap size of 4 mm (optical path length of 8 mm) for the transflection measurement of liquids.Suitable for disposable 28 mm reflection vials (6.7402.140).
6.07402.940
Large reflector OMNIS NIR, 1 mmReflector with a gap size of 1 mm (optical path length of 2 mm) for the transflection measurement of liquids.Suitable for transflection vessels (6.07402.260 and 6.7401.000).
6.07402.950
Large reflector OMNIS NIR, 2 mmReflector with a gap size of 2 mm (optical path length of 4 mm) for the transflection measurement of liquids.Suitable for transflection vessels (6.07402.260 and 6.7401.000).
6.07402.960
Large reflector OMNIS NIR, 4 mmReflector with a gap size of 4 mm (optical path length of 8 mm) for the transflection measurement of liquids.Suitable for transflection vessels (6.07402.260 and 6.7401.000).
6.07402.970
Small reflector OMNIS NIR, 0.5 mmReflector with a gap size of 0.5 mm (optical path length of 1 mm) for the transflection measurement of liquids.Suitable for disposable vials 28 mm reflection (6.7402.140).
6.07402.980
Large reflector OMNIS NIR, 0.5 mmReflector with a gap size of 0.5 mm (optical path length of 1 mm) for the transflection measurement of liquids. Suitable for transflection vessels (6.07402.260 and 6.7401.000).
AUT.FIBER.200.UVIR
Autolab 200 μm optical fiber for UV/VIS/NIR applications.The Autolab spectrophotometer and light source are designed to connect to the electrochemical cell or cuvette holder using optical fibers. The standard dimensions of the optical fibers is 2 m in length and 200 μm in diameter. The fibers are fitted with SMA-905 connectors on both ends.
6.7402.140
Disposable vials, 28 mm, reflection216 lockable disposable glass vials with a diameter of 28 mm for analyses of solids in reflection. Suitable for the following analyzers:NIRS DS2500 Analyzer; NIRS XDS RapidContent (Solid) Analyzer; NIRS XDS MultiVial Analyzer; NIRS XDS MasterLab Analyzer;
6.7450.130
Certified wavelength and transmission standards (6-pc. set).Certified wavelength and transmission standards (0.25 AU, 0.5 AU, 1 AU, 1.5 AU and 2.0 AU) for NIRS XDS RapidLiquid Analyzer and NIRS XDS Transmission OptiProbe Analyzer in regulated environments.
6.07401.320
Flow-through cell, 2 mmFlow quartz cuvettes with an optical path length of 2.0 mm suitable for near-infrared spectroscopy (NIRS) analyses.Compatible with:Holder OMNIS NIR, flow-through cell (6.070401.100);
6.07401.330
Flow-through cell, 2.5 and 5 mmFlow quartz cuvettes with quartz glass window and two optical path lengths (2.5 mm or 5.0 mm) suitable for near-infrared spectroscopy (NIRS) analyses.Compatible with:Holder OMNIS NIR, flow-through cell (6.070401.100)
6.07401.340
Flow-through cell, 5 and 10 mmFlow quartz cuvettes with quartz glass window and two optical path lengths (5.0 mm or 10.0 mm) suitable for near-infrared spectroscopy (NIRS) analyses.Compatible with:Holder OMNIS NIR, flow-through cell (6.070401.100);
6.7401.310
Flow-through cell, 1 mmFlow quartz cuvettes with an optical path length of 1.0 mm suitable for near-infrared spectroscopy (NIRS) analyses.Compatible with:Holder OMNIS NIR, flow-through cell (6.07401.100); DS2500 holder for flow cells (6.7493.000) ;
6.7401.300
Flow-through cell, 0.5 mmFlow quartz cuvettes with quartz glass window and an optical path length of 0.5 mm suitable for near-infrared spectroscopy (NIRS) analyses.Compatible with:Holder OMNIS NIR, flow-through cell (6.070401.100); DS2500 holder for flow cells (6.7493.000);
6.7401.230
Quarzküvette, 10 mmQuarzglasküvette mit einem Fenster aus Quarzglas in höchster Reinheit und Homogenität. Die Küvetten haben eine Transmission von über 80% im Wellenlängenbereich von 200 nm - 2500 nm.Kompatibel mit:NIRS Spacer für 12.5 mm Küvettenset (6.7403.180); DS2500 Halter für 10 mm Küvette (6.7492.130); Halter OMNIS NIR, Küvette, 10 mm (6.07401.040) ;
6.7401.200
Quartz cuvette, 1 mmQuartz glass cuvette with a window made of quartz glass of maximum purity and homogeneity. The cuvettes have a transmission of more than 80% in the wavelength range of 200–2500 nm.Compatible with:NIRS Spacer for set of 12.5 mm cuvettes (6.7403.180); DS2500 holder for 1 mm cuvette (6.7492.100); Holder OMNIS NIR, cuvette, 1 mm (6.07401.010);
6.7401.210
Quartz cuvette, 2 mmQuartz glass cuvette with a window made of quartz glass of maximum purity and homogeneity. The cuvettes have a transmission of more than 80% in the wavelength range of 200–2,500 nm.Compatible with:NIRS Spacer for set of 12.5 mm cuvettes (6.7403.180); DS2500 holder for 2 mm cuvette (6.7492.110); Holder OMNIS NIR, cuvette, 1 mm (6.07401.010) ;
6.7401.220
Quartz cuvette, 5 mmQuartz glass cuvette with a window made of quartz glass of maximum purity and homogeneity. The cuvettes have a transmission of more than 80% in the wavelength range of 200–2500 nm.Compatible with:NIRS Spacer for set of 12.5 mm cuvettes (6.7403.180); DS2500 holder for 5 mm cuvette (6.7492.120); Holder OMNIS NIR, cuvette, 5 mm (6.07401.030);
6.7402.050
DS2500 large sample cupLarge sample cup for the spectral recording of powders and granulates in reflection at various sample positions using the NIRS DS2500 Analyzer.
6.7402.110
Disposable vials, 15 mm, reflection123 lockable disposable glass vials with a diameter of 15 mm for analyses of solids in reflection. Suitable for NIRS RapidContent (Solid) Analyzers of the XDS, DS2500 and OMNIS product families.
6.7402.120
Disposable vials, 19 mm, reflection225 lockable disposable glass vials with a diameter of 19 mm for analyses of solids in reflection. Suitable for NIRS RapidContent (Solid) Analyzers of the XDS, DS2500 and OMNIS product families.
6.7402.130
Disposable vials, 22 mm, reflection172 lockable disposable glass vials with a diameter of 22 mm for analyses of solids in reflection. Suitable for NIRS RapidContent (Solid) Analyzers of the XDS, DS2500 and OMNIS product families.
6.2164.020
Power supply unit 100-240 V / 24 V DCPower supply unit for OMNIS NIR Analyzer.
6.07410.020
Gripper fingers 8–28 mmGripper fingers for OMNIS Sample Robot – NIR for gripping vials with an outer diameter of 8–28 mm.
6.07402.140
Petri dishes, PS, 100 mm, qty. 100Disposable petri dishes of polystyrene with a diameter of 100 mm.Compatible with:Large holder OMNIS NIR, 100 mm (6.07402.100).;
6.07402.150
Petri dish, Duroplan, 100 mm, qty. 1Petri dish of Duroplan glass with a diameter of 100 mm.Compatible with:Large holder OMNIS NIR, 100 mm (6.07402.100).;
6.07402.240
Petri dishes, PS, 60 mm, qty. 100Disposable petri dishes of polystyrene with a diameter of 60 mm.Compatible with:Small holder OMNIS NIR, 60 mm (6.07402.200).;
6.07402.250
Petri dish, Duroplan, 60 mm, qty. 1Petri dish of Duroplan glass with a diameter of 60 mm.Compatible with:Small holder OMNIS NIR, 60 mm (6.07402.200).;
6.02041.130
OMNIS sample rack, 50 x 6 mL vialsOMNIS sample rack for OMNIS Sample Robot NIR, suitable for 50 x 6 mL sample glasses (62419000) with septum (61448057).
6.02041.090
OMNIS sample rack 77 x 15 mmOMNIS sample rack for OMNIS Sample Robot – NIR, suitable for 77 disposable vials with a diameter of 15 mm for measurements in reflection (6.7402.110).
6.02041.100
OMNIS sample rack 50 x 19 mmOMNIS sample rack for OMNIS Sample Robot – NIR, suitable for 50 disposable vials with a diameter of 19 mm for measurements in reflection (6.7402.120).
6.02041.110
OMNIS sample rack 50 x 22 mmOMNIS sample rack for OMNIS Sample Robot – NIR, suitable for 50 disposable vials with a diameter of 22 mm for measurements in reflection (6.7402.130).
6.02041.120
OMNIS sample rack 27 x 28 mmOMNIS sample rack for OMNIS Sample Robot – NIR, suitable for 27 disposable vials with a diameter of 28 mm for measurements in reflection (6.7402.140).
6.02041.080
OMNIS sample rack 77 x 8 mmOMNIS sample rack for OMNIS Sample Robot – NIR suitable for 77 disposable vials with an optical path length of 8 mm for measurements in transmission (6.7402.240).
6.7402.070
Disposable vials, 2 mm diameter, transmission200 lockable disposable glass vials (borosilicate) with a diameter of 2 mm for analyses of liquids in transmission mode.Compatible with:Holder OMNIS NIR, vial, 2 mm (6.07401.050); DS2500 holder for flow cells (6.7492.000);
6.7402.100
Disposable vials, 10 mm diameter, transmission195 lockable disposable glass vials (borosilicate) with a diameter of 10 mm for analyses of liquids in transmission.Compatible with:Holder OMNIS NIR, vial, 10 mm (6.07401.080); DS2500 holder for 4 mm disposable vials (6.7492.030);
6.7402.250
Disposable vial, 4 mm, transmission, qty. 200200 disposable glass vials (borosilicate) with an optical path length of 4 mm for analyses of liquids in transmission. Compatible with:Holder OMNIS NIR, vial, 4 mm (6.07401.060); DS2500 holder for 4 mm disposable vials (6.7492.010);
BWT-840000681
Raman Stand-off Lens (0.6-6 m)A telescope Stand-off lens for BAC100/BAC102 fiber-optic Raman probes. Wide zoom range for sample measurement ranges from 0.6 meters to 6 meters. Suitable for a Raman excitation range from 500 nm to 850 nm.RTS202-VIS-NIR
6.7402.240
Disposable vial, 8 mm, transmission, qty. 100100 disposable glass vials (borosilicate) with an optical path length of 8 mm for analyses of liquids in transmission. The disposable vials are supplied with the associated stoppers (number of pieces = 100).Compatible with:Holder OMNIS NIR, vial, 8 mm (6.07401.070); DS2500 holder for 8 mm disposable vials (6.7492.020) ;
001RDX
Optical fiber spectro-electrochemical flow cell setupThis is a horizontally mounted, multi-purpose spectroelectrochemical cell designed to be coupled with light sources and spectrometers (UV-Vis, NIR, IR) via optical fibers. It enables obtaining electrochemical and spectroscopic information from liquid sample or thin films in systems where variations in applied potential induce changes in observed spectra.Applied collimating lenses are curved optical lenses that enables parallel irradiation of the sample. Each lens is 5 mm in diameter, has focal length of 10 mm and wavelength range of 200-2000 nm. The cell consists of a polyether ether ketone (PEEK) flow chamber equipped with magnetic mount sample holder (a screw version is available on request), screw mount quartz window holder and two different mini tripods.The cell is meant to be used with standard reference electrode having 6 mm in diameter and counter electrode either in the form of a rod or helix with 6 mm in diameter and 15 mm active length.Please note: this product is not available from Metrohm Germany.