942 Extension Module Vario ChS/PP
2.942.0300
-
- Bottle attachment / GL 45 - 3 x UNF 10/32
- 6.1602.150
- For the connection of 1/16 in. capillaries. Used in conjunction with MSM auxiliary solutions and in Metrohm Inline Sample Preparation.
- <p>For the connection of 1/16 in. capillaries. Used in conjunction with MSM auxiliary solutions and in Metrohm Inline Sample Preparation.</p>
- PCS
- 1
- Glass bottle / 1000 mL / GL 45
- 6.1608.020
- Bottle for auxiliary solutions.
- <p>Bottle for auxiliary solutions.</p>
- PCS
- 1
- PTFE capillary 0.5 mm i.d. / 3 m
- 6.1803.030
- Capillary for inline dialysis, for Dialysis Unit, IC Dialysis Sample Processor, IC Liquid Handling Dialysis Unit
- Capillary for inline dialysis, for Dialysis Unit, IC Dialysis Sample Processor, IC Liquid Handling Dialysis Unit
- PCS
- 1
- PharMed® pump tubing (orange/yellow), 3-stopper
- 6.1826.420
- For MSM regeneration with peristaltic pump.
- <p>For MSM regeneration with peristaltic pump.</p>
- PCS
- 2
- Cable Extension Module - Professional IC, 1 m
- 6.2156.070
- Cable connecting the extension module with the Professional IC instrument
- Cable connecting the extension module with the Professional IC instrument
- PCS
- 1
- Colored sleeves for capillaries
- 6.2251.000
- Colored pieces of heat shrink tubing for capillary coding. Three pieces each of five different colors.
- Colored pieces of heat shrink tubing for capillary coding. Three pieces each of five different colors.
- PCS
- 1
- カップリング チューブニップル/UNF 10/32、2個
- 6.2744.034
- 圧力調整ネジとポンプチューブを接続。2個。ペリスタリックポンプ付きIC装置用。
- <p>圧力調整ネジとポンプチューブを接続。2個。ペリスタリックポンプ付きIC装置用。</p>
- PCS
- 1
- Pump tubing connector with security lock and filter
- 6.2744.180
- For the connection of a pump tubing and a capillary with built-in filter
- For the connection of a pump tubing and a capillary with built-in filter
- PCS
- 2
- Accessory kit: Vario/Flex ChS
- 6.5000.030
- Set of accessories for chemical suppression (ChS) for Professional IC Vario and Compact IC Flex instruments. Without Suppressor Rotor.
- <p>Set of accessories for chemical suppression (ChS) for Professional IC Vario and Compact IC Flex instruments. Without Suppressor Rotor.</p>
- PCS
- 1
-
- 942 Extension Module Vario ChS/PP
- 1.942.0300
- 942 拡張モジュール Vario ChS/PPは、プロフェッショナルIC Vario装置群のための拡張モジュールです。このモジュールはプロフェッショナルIC Vario装置のサプレッサー再生用ペリスタリティックポンプ付きの完全なケミカルサプレッションの組み込み、あるいはインライン中和またはインライン陽イオン除去を可能にします。典型的な使用領域:- 2つ目の分析チャンネル用ケミカルサプレッション- インライン中和化/陽イオン除去
- <p>942 拡張モジュール Vario ChS/PPは、プロフェッショナルIC Vario装置群のための拡張モジュールです。このモジュールはプロフェッショナルIC Vario装置のサプレッサー再生用ペリスタリティックポンプ付きの完全なケミカルサプレッションの組み込み、あるいはインライン中和またはインライン陽イオン除去を可能にします。</p> <p>典型的な使用領域:</p> <p>- 2つ目の分析チャンネル用ケミカルサプレッション</p> <p>- インライン中和化/陽イオン除去</p>
- PCS
- 1
- Bottle attachment / GL 45 - 3 x UNF 10/32
- 6.1602.150
- For the connection of 1/16 in. capillaries. Used in conjunction with MSM auxiliary solutions and in Metrohm Inline Sample Preparation.
- <p>For the connection of 1/16 in. capillaries. Used in conjunction with MSM auxiliary solutions and in Metrohm Inline Sample Preparation.</p>
- PCS
- 1
- Glass bottle / 1000 mL / GL 45
- 6.1608.020
- Bottle for auxiliary solutions.
- <p>Bottle for auxiliary solutions.</p>
- PCS
- 1
- PTFE capillary 0.5 mm i.d. / 3 m
- 6.1803.030
- Capillary for inline dialysis, for Dialysis Unit, IC Dialysis Sample Processor, IC Liquid Handling Dialysis Unit
- Capillary for inline dialysis, for Dialysis Unit, IC Dialysis Sample Processor, IC Liquid Handling Dialysis Unit
- PCS
- 1
- PharMed® pump tubing (orange/yellow), 3-stopper
- 6.1826.420
- For MSM regeneration with peristaltic pump.
- <p>For MSM regeneration with peristaltic pump.</p>
- PCS
- 2
- Cable Extension Module - Professional IC, 1 m
- 6.2156.070
- Cable connecting the extension module with the Professional IC instrument
- Cable connecting the extension module with the Professional IC instrument
- PCS
- 1
- Colored sleeves for capillaries
- 6.2251.000
- Colored pieces of heat shrink tubing for capillary coding. Three pieces each of five different colors.
- Colored pieces of heat shrink tubing for capillary coding. Three pieces each of five different colors.
- PCS
- 1
- カップリング チューブニップル/UNF 10/32、2個
- 6.2744.034
- 圧力調整ネジとポンプチューブを接続。2個。ペリスタリックポンプ付きIC装置用。
- <p>圧力調整ネジとポンプチューブを接続。2個。ペリスタリックポンプ付きIC装置用。</p>
- PCS
- 1
- Pump tubing connector with security lock and filter
- 6.2744.180
- For the connection of a pump tubing and a capillary with built-in filter
- For the connection of a pump tubing and a capillary with built-in filter
- PCS
- 2
- Accessory kit: Vario/Flex ChS
- 6.5000.030
- Set of accessories for chemical suppression (ChS) for Professional IC Vario and Compact IC Flex instruments. Without Suppressor Rotor.
- <p>Set of accessories for chemical suppression (ChS) for Professional IC Vario and Compact IC Flex instruments. Without Suppressor Rotor.</p>
- PCS
- 1
-
- Adapter to Leak Sensor at Professional IC
- 6.2103.170
- Adapter to connect two leak sensors to a Professional IC instrument
- <p>Adapter to connect two leak sensors to a Professional IC instrument</p>
- PCS
- 1
- MSM Rotor A
- 6.2832.000
- Suppressor rotor for all IC instruments with MSM (Metrohm Suppressor Module)
- Suppressor rotor for all IC instruments with MSM (Metrohm Suppressor Module)
- PCS
- 1
- SPM Rotor A
- 6.2835.000
- Rotor for inline sample preparation with cation exchange
- Rotor for inline sample preparation with cation exchange
- PCS
- 1
- MSM-HC Rotor A
- 6.2842.000
- Suppressor rotor for all IC instruments with MSM-HC (Metrohm Suppressor Module with high capacity)
- Suppressor rotor for all IC instruments with MSM-HC (Metrohm Suppressor Module with high capacity)
- PCS
- 1
- アダプタスリーブ、MSM
- 6.2842.020
- アダプタスリーブを用いれば、MSM Rotor A と MSM-LC Rotor A のいずれも、ローターハウジングに取り付けることができます。
- <p>アダプタスリーブを用いれば、MSM Rotor A と MSM-LC Rotor A のいずれも、ローターハウジングに取り付けることができます。</p>
- PCS
- 1
- MSM-LC Rotor A
- 6.2844.000
- Suppressor rotor for use with 2 mm columns.
- Suppressor rotor for use with 2 mm columns.
- PCS
- 1
- MagIC Net 4.2 Multi: 3 ライセンス
- 6.6059.423
- すべてのインテリジェントな Professional IC システム、コンパクトな IC 装置とそれらの周辺機器、すべての検出器と様々なオートサンプラー、800 Dosino、771 Compact Interface などのコントロールのためのクライアント/サーバーに対応可能な Metrohm クロマトグラフィーソフトウェア。このソフトウェアにより、イオンクロマトグラフィー分析のチェック、データ取得、評価・モニタリングとレポートの作成が可能となります。データとメソッドは一元的に保存されます。ルーチンオペレーションのためのグラフィック ユーザーインターフェース、広範なデータベース プログラム、メソッド開発、コンフィグレーションならびに手動のシステム制御; 非常にフレキシブルなユーザー管理、高性能なデータベース オペレーション、広範なデータエクスポート機能、独自設定可能なレポート作成機能、全システム コンポーネントおよびクロマトグラフィー結果のコントロールおよびモニタリング。MagIC Net Multi は FDA 規定21 CFR パート 11および GLP に完全に準拠しています。MagIC Net は 15 のダイアログ言語で使用可能です: ドイツ語、英語、中国語 (繁体、簡体)、フランス語、イタリア語、スペイン語、ポルトガル語、ブルガリア語、チェコ語、ハンガリー語、日本語、韓国語、ロシア語、スロバキア語このバージョンではグラフィックユーザーインターフェースが新しくなり、4K モニターでのスケーリングやユーザーインターフェースの鮮明さ等が向上しました。社外ネットワークのサーバーによるクライアントサーバーシステムのための性能が向上しました。3 つのライセンスを有するクライアント・サーバーバージョン
- <p>すべてのインテリジェントな Professional IC システム、コンパクトな IC 装置とそれらの周辺機器、すべての検出器と様々なオートサンプラー、800 Dosino、771 Compact Interface などのコントロールのためのクライアント/サーバーに対応可能な Metrohm クロマトグラフィーソフトウェア。<br/>このソフトウェアにより、イオンクロマトグラフィー分析のチェック、データ取得、評価・モニタリングとレポートの作成が可能となります。<br/>データとメソッドは一元的に保存されます。<br/> <br/>ルーチンオペレーションのためのグラフィック ユーザーインターフェース、広範なデータベース プログラム、メソッド開発、コンフィグレーションならびに手動のシステム制御; 非常にフレキシブルなユーザー管理、高性能なデータベース オペレーション、広範なデータエクスポート機能、独自設定可能なレポート作成機能、全システム コンポーネントおよびクロマトグラフィー結果のコントロールおよびモニタリング。</p><p>MagIC Net Multi は FDA 規定21 CFR パート 11および GLP に完全に準拠しています。</p><p>MagIC Net は 15 のダイアログ言語で使用可能です: ドイツ語、英語、中国語 (繁体、簡体)、フランス語、イタリア語、スペイン語、ポルトガル語、ブルガリア語、チェコ語、ハンガリー語、日本語、韓国語、ロシア語、スロバキア語</p><p>このバージョンではグラフィックユーザーインターフェースが新しくなり、4K モニターでのスケーリングやユーザーインターフェースの鮮明さ等が向上しました。<br/>社外ネットワークのサーバーによるクライアントサーバーシステムのための性能が向上しました。</p><p>3 つのライセンスを有するクライアント・サーバーバージョン</p>
- PCS
- 1