The NIRS XDS Process Analyzer – SingleFiber provides the next generation of process analyzers for real-time analysis in the pharmaceutical and chemical industries. Non-destructive, accurate measurements of clear liquids are performed directly in the process line or in a reaction vessel. Up to 9 probes and/or flow-cells can be connected to the analyzer. All 9 channels can be configured independently from each other in the software. Single Fiber optics allows the 9 measuring points to be up to 100 meter away from the XDS NIR process analyzer.
技術仕様
| Dimensions in mm (W/H/D) | 457/572/387 |
|---|---|
| Weight kg | 42 |
| Ingress Protection | IP65 |
| Ambient Temperature | 5-35 °C |
| Number of sample streams | 1 to 9 |
Technical specifications
Wavelength range: 800 - 2,200 nm
Detector: Extended InGaAs (Indium Gallium Arsenide)
Data Increment: 0.5 nm
Average time per result: 3 - 30 seconds
General
Lifetime of the light source: = 8000 h
Power supply: 100 - 240 VAC, 50 - 60 Hz, 1 A,
Power consumption: 100 W typical, max. 300 W
Software package: Vision for instrument operation and method development
Standard Operating temperature: 0 - 35 °C (32 - 95 °F)
Humidity: 10 - 90% relative
Weight: 42.2 kg (93 lbs)
Dimensions (W x H x D): 407 x 610 x 362 mm (16 x 24 x 14.25 inches)
Housing: basic device IP65/Nema 4X, stainless steel
Various enclosure options for hazardous areas or environmental conditions outside the above mentioned conditions available.
Fiber Optics and Probes
- Single Fiber Optic Cable with SMA connectors at the analyzer and probe (requires probe or flow-through cell for use)
- Stainless Steel or Hastalloy Probes (other materials available as well)
Micro Transmission Probe Pair
Single-sided Transmission Probe
Purge and 45 degree angle probe
Transmission flow-through cell
Process Communication Options
- OPC
- Digital protocols
MODBUS, PROFIBUS, etc. - VISION I/O Modules
Available with 8, 16, or 24 Analog Channels, 24 Digital Channels
-
- NIRS SingleFiber optical fiber, 2 m
- 6.7440.170
- One-channel optical fiber in 2 m length for NIRS Process Analyzers
- <p>One-channel optical fiber in 2 m length for NIRS Process Analyzers</p>
- PCS
- 1
- NIRS 99% reflection and wavelength standard for process instrument, 1 inch diameter, 45° bevel
- 6.7450.090
- NIRS 99% reflection and wavelength standard for process instrument with 1 inch diameter and 45° angle
- <p>NIRS 99% reflection and wavelength standard for process instrument with 1 inch diameter and 45° angle</p>
- PCS
- 1
- NIRS 99% reflection and wavelength standard for process instrument, 0.5 inch probe diameter
- 6.7450.080
- NIRS 99% reflection and wavelength standard for process instrument, 0.5 inch probe diameter
- PCS
- 1
- NIRS Process, I/O Communication box
- 6.7440.480
- I/O Communication box for process instruments with 24 analog and 24 digital channels
- <p>I/O Communication box for process instruments with 24 analog and 24 digital channels</p>
- PCS
- 1
- NIRS 99% reflection and wavelength standard process, 1 inch diameter
- 6.7450.070
- NIRS 99% reflection and wavelength standard for process instrument with 1 inch probe diameter
- PCS
- 1