- AN-CIC-017Fluorine in copper concentrates using Metrohm Combustion IC
Copper concentrate is an important raw material for copper mills. The concentrate is often contaminated with corrosive fluorine, which is why the fluorine concentration must be checked at regular intervals. A convenient and reliable determination method is Combustion IC in combination with sacrificing vial technology. The sample is placed inside the quartz combustion pipe in a horizontally positioned quartz vial, both ends of which are sealed with glass wool. During combustion, the quartz-destroying components (e.g., fluoride, alkali and earth alkali metals) that are released are captured by the quartz vial and the quartz wool, ensuring that they are thus unable to reach the quartz combustion pipe at all.Keyword: pyrohydrolysis
- AN-T-181Lithium in brine
Lithium is a soft metal which is used for many applications, such as production of high-temperature lubricants or heat-resistant glass. Furthermore, lithium is used in large quantities in for battery production. It is obtained from brines and high-grade lithium ores. Depending on the lithium concentration, extraction may or may not be economically viable.This Application Note demonstrates a method to determine the lithium concentration in brines by potentiometric titration. Lithium and fluoride precipitate in ethanol as insoluble lithium fluoride. Using ammonium fluoride as the titrant and a fluoride ion-selective electrode (ISE), determination via potentiometric titration is possible. This method is more reliable, faster, and less expensive than the determination of lithium in brine by other more sophisticated techniques such as atomic absorption spectroscopy (AAS).
- AN-PAN-1042Online trace analysis of anions in the primary circuit of nuclear power plants
Measures to monitor or prevent corrosion are crucial in nuclear power plants, where significant risks to health and safety can occur if corrosion is left unchecked. Anions corrode metals under high temperature and pressure, therefore their concentrations must be monitored at all times. The analytical challenge in the primary circuit is detection of anions in the μg/L range alongside gram quantities of boric acid and lithium hydroxide. Precise, reliable trace analysis requires the method to be automated as much as possible. The 2060 IC Process Analyzer from Metrohm Process Analytics can measure several anions from a single injection, with combined Inline Preconcentration and Inline Matrix Elimination to measure low anion concentrations precisely and reliably time after time.
- AN-S-236Drinking water quality by EPA 300.1
Fast and reliable analysis of drinking water by combining EPA method 300.1 Parts A and B in a single IC run.
- WP-009Automated determination of major anions and oxyhalides in drinking water using OMNIS IC and single-standard calibration
This white paper demonstrates how OMNIS IC combines high analytical performance with advanced laboratory automation for drinking water analysis.
- AN-CIC-035Halogens and sulfur in solid samples according to EN 17813
Organic halides must be monitored in the environment. Combustion ion chromatography (CIC) is used for accurate halogen analysis in solids following EN 17813:2023.
- AN-CIC-033Monitoring PFASs in water sources
AOF (adsorbable organic fluorine) is used to screen for per- and polyfluorinated alkyl substances in aqueous matrices via pyrohydrolytic combustion and ion chromatography.
- AN-S-403Anions in lithium-ion battery solvents
N-Methylpyrrolidone (NMP) is crucial for lithium-ion battery production. Metrohm’s intelligent Preconcentration Technique with Matrix Elimination enables µg/L-level anion analysis in NMP.
- AN-S-404Water quality testing with EPA 300.1
The Metrosep A Supp 21 column and 948 Continuous IC Module, CEP enable efficient, automated single-run analysis of major anions and disinfection byproducts in water.
- 8.000.6042Straightforward multipoint calibration using a single standard
The combination of 850 Professional IC, 858 Professional Sample Processor, Dosino and MagIC NetTM software offers a variety of automated ion chromatographic sample preparation and calibration techniques available as an anion, cation or dual channel system. Calibration is straightforward and requires only one multi-ion standard.Inline calibration allows the calibration of any standard concentration in the ppt range by using one single stable standard solution at the ppb level. By using a preconcentration column and switching the valves one, two or more times different calibration concentrations at the ultra-trace level can be created with unprecedented reproducibility. The inline preconcentration technique uses a pre-concentration column and is ideally suited for trace analysis in complex matrices, especially when combined with matrix elimination. Besides facilitating the preparation of g/L to ng/L calibration graphs Metrohm`s intelligent techniques are capable of logical decision making. While Metrohm`s intelligent Partial Loop technique (MiPT) allows samples with a wide concentration range to be injected without previous manual dilution, the intelligent inline dilution technique, after the first sample injection, compares peak areas, calculates, if necessary, the dilution factor, dilutes and automatically re-injects the sample. The presented inline techniques allow the rationalization of the time-consuming, error-prone and cost-intensive manual preparation of standard solutions. They guarantee that the determined sample concentrations always lie within the calibration range. Higher sample throughputs as well as lower analysis costs and improved data reliability are achieved.
- AN-CIC-034Fast analysis of AOX in waters by CIC
Combustion ion chromatography (CIC) measures AOX (adsorbable organically bound halogens, i.e., AOCl, AOBr, AOI) and AOF as well as CIC AOX(Cl) according to EN ISO 18127.
- AN-D-003Quality control of dialysis concentrates
Ion chromatography (IC) provides an automated, fast, and sensitive solution to accurately quantify cationic and anionic components including acetate simultaneously. This comprehensive approach makes IC an economic alternative to traditional techniques for the quality control of pharmaceutical solutions like haemodialysis concentrates. Ease-of use, accuracy, and the high-throughput of IC increase productivity and comply with the demands of modern routine and research labs.
- AN-S-378Anions in refining process water applying tandem conductivity and UV detection
ASTM D8234 describes the determination of anions in high saline water by applying suppressed conductivity followed by UV/VIS detection. This combination enables the determination of e.g. nitrite by UV detection. With conductivity detection, this quantification is not possible or difficult due to the very large chloride peak. The actual sample is a refining process liquid with a high chloride content. As the sample solution also contains organic material, Inline Dialysis is applied to protect the analytical column. The combination of the two detection modes and the Inline Dialysis option reduces manual sample preparation and substantially increases the accuracy of the analysis.
- AN-Q-008Trace monitoring in distilled water using ion chromatography
The combination of 940 Professional IC Vario, 942 Extension Module Vario LQH and 941 Eluent Preparation Module enables process monitoring with the aid of ion chromatography. Assigned the designation ProfIC Vario 12 Anion, this combination is the anion variant of Metrohm Process IC. Intelligent preconcentration technology with matrix elimination is used for sample preparation. The use of an ELGA PURELAB® Flex 6 guarantees the supply of ultrapure water of the highest quality, particularly in cases of high numbers of samples.
- AN-S-371Bromate in water with conductivity detection: optimized separation and LOQ
Determination of disinfection byproducts in water is a standard application for ion chromatography. Applying conductivity detection the separation of chlorite and bromate from chloride is crutial for μg/L detection limits. The combination of a Metrosep A Supp 7 - 250/4.0 and a Metrosep A Supp 16 Guard/4.0 lead to an improved separation. The Limit of Quantification for bromate is around 1 μg/L
- AN-Q-005Online analysis of trace anions in power plant water matrices
A setup that allows online sampling is crucial for immediate and contamination-free analysis of power plant water samples. This application recommends a setup that facilitates simultaneous anion/cation determinations. Automated inline sample preparation combines variable preconcentration (MiPCT) and calibration with a single multi-ion standard. AN-Q-004 displays the respective cation results.
- AN-S-382Metrohm IC Driver for OpenLab CDS: Anion and cation analysis in a soft drink
OpenLab CDS is the newest generation of chromatography data systems from Agilent, combining chromatography and mass spectrometry in a single software platform. The Metrohm IC Driver for OpenLab CDS integrates Metrohm IC instrumentation for full control and data acquisition. The present application describes the simultaneous analysis of anions and cations in a soft drink with a dual channel IC system. Eluent is prepared by applying Inline Eluent Production.
- AN-S-304Variable Inline Preconcentration including Matrix Elimination for trace anion analysis (MiPCT-ME)
Metrohm Inline Preconcentration Technique with Matrix Elimination (MiPCT-ME) is a powerful tool that combines preconcentration, matrix elimination, and multilevel calibration. The latter only requires a single multi-ion standard solution. The 800 Dosino takes over all liquid handling tasks. The shown system setup allows sample analysis from 0.1 µg/L up to 1.0 mg/L.
- AN-S-377Anions in high ionic water by IC using tandem conductivity and UV detection
«High ionic water» is typically water containing a high concentration of chloride (e.g. seawater, brine), but this also describes water samples resulting from petrochemical processes. Due to the high chloride concentrations, the conductivity determination of minor ionic components is limited. Thus, minor anions like nitrite, bromide, and nitrate can elute under or on the tail of the large chloride peak, and their detection in low concentrations is hampered. However, combining conductivity and UV/VIS detection as described in ASTM D8234 enables the determination of anions that are UV active. Chloride does not interfere in this situation. The described technique enables the interference-free simultaneous determination of trace anions besides high chloride content.
- AN-S-301Comprehensive water analysis with VoltIC pro I
VoltIC pro I is the perfect combination of voltammetry and ion chromatography for the fully automated analysis of anions, cations, and heavy metals (e.g., Zn, Cd, Pb, Cu): comprehensive water analysis on a single system.
- AN-S-387Comprehensive water analysis with TitrIC flex II
The TitrIC flex II system is the perfect combination of titration, direct measurement, and ion chromatography for fully automated analysis of all key parameters. These include pH, conductivity, hardness, anions, cations, as well as the calculation of the ion balance: comprehensive water analysis from one system.
- AN-S-347Comprehensive water analysis with VoltIC Professional 1
VoltIC Professional 1 is the perfect combination of voltammetry and ion chromatography for the fully automated, simultaneous analysis of anions, cations, and heavy metals (e.g., Zn, Cd, Pb, Cu). The multiple-parameter analysis uses the same "Liquid Handling" elements and a shared sample changer, thus saving on space and costs.
- 8.000.6012Automated logical dilution for ion chromatographic determinations
The combination of 850 Professional IC, 858 Professional Sample Processor, Dosino and MagIC NetTM software offers a variety of sophisticated ion chromatographic sample preparation techniques. One of these is the automated inline dilution of samples.After the first sample injection, MagIC NetTM verifies if the area of the sample peak lies within the calibration range. If the measured peak area is outside these limits, the software calculates the appropriate dilution factor, dilutes and automatically re-injects the sample. For all investigated ions (Li+, Na+, K+, Ca2+, Mg2+, F-, Cl- , NO2-, Br-, NO3-, SO42- ), automated logical dilution yielded coefficients of determination (R2) better than 0.9999. Direct-injection recoveries for cations and anions were within 98.6…99.5% and 93.4…100.4% respectively. In contrast, after logical dilution, recoveries for cations and anions were within 100.1…102.9% and 98.2…102.6% respectively. The relative standard deviations for all determinations involving diluted sample solutions were smaller than 0.91%.
- AN-H-127Thermometric analysis of aluminum by back-titration
This Application Note describes the determination of aluminum in samples containing silicon dioxide using thermometric titration and EDTA as the titrant. Excess EDTA is titrated with a Cu2+ solution of known concentration. The initial, uncomplexed Cu2+ ions react immediately with the H2O2 present in the solution, leading to a recognizable sudden increase in temperature.
- AN-D-001Metrohm IC Driver for OpenLab CDS
This application focuses on the simultaneous analysis of cations and suppressed anions with a dual channel Metrohm IC operated by OpenLab CDS.
- AN-M-015Trace haloacetic acids, dalapon, and bromate measurement in drinking water
Chlorinating drinking water can form carcinogenic byproducts. EPA Method 557 enables µg/L-level quantification of haloacetic acids using Metrohm IC-MS/MS technology.