Search...
Tried-and-tested applications
Applications (26)Electrodes for combined fluoride ISE
Electrodes (3)Columns for combined fluoride ISE
Columns (5)News for combined fluoride ISE
News (4)Inspiring industry insights for combined fluoride ISE
Blog (9)On-demand webinars for combined fluoride ISE
Webinars (1)- AN-CIC-017AN-CIC-017Fluorine in copper concentrates using Metrohm Combustion IC
Copper concentrate is an important raw material for copper mills. The concentrate is often contaminated with corrosive fluorine, which is why the fluorine concentration must be checked at regular intervals. A convenient and reliable determination method is Combustion IC in combination with sacrificing vial technology. The sample is placed inside the quartz combustion pipe in a horizontally positioned quartz vial, both ends of which are sealed with glass wool. During combustion, the quartz-destroying components (e.g., fluoride, alkali and earth alkali metals) that are released are captured by the quartz vial and the quartz wool, ensuring that they are thus unable to reach the quartz combustion pipe at all.Keyword: pyrohydrolysis
- AN-T-181Lithium in brine
Lithium is a soft metal which is used for many applications, such as production of high-temperature lubricants or heat-resistant glass. Furthermore, lithium is used in large quantities in for battery production. It is obtained from brines and high-grade lithium ores. Depending on the lithium concentration, extraction may or may not be economically viable.This Application Note demonstrates a method to determine the lithium concentration in brines by potentiometric titration. Lithium and fluoride precipitate in ethanol as insoluble lithium fluoride. Using ammonium fluoride as the titrant and a fluoride ion-selective electrode (ISE), determination via potentiometric titration is possible. This method is more reliable, faster, and less expensive than the determination of lithium in brine by other more sophisticated techniques such as atomic absorption spectroscopy (AAS).
- AN-PAN-1042Online trace analysis of anions in the primary circuit of nuclear power plants
Measures to monitor or prevent corrosion are crucial in nuclear power plants, where significant risks to health and safety can occur if corrosion is left unchecked. Anions corrode metals under high temperature and pressure, therefore their concentrations must be monitored at all times. The analytical challenge in the primary circuit is detection of anions in the μg/L range alongside gram quantities of boric acid and lithium hydroxide. Precise, reliable trace analysis requires the method to be automated as much as possible. The 2060 IC Process Analyzer from Metrohm Process Analytics can measure several anions from a single injection, with combined Inline Preconcentration and Inline Matrix Elimination to measure low anion concentrations precisely and reliably time after time.
- AN-S-236Drinking water quality by EPA 300.1
Fast and reliable analysis of drinking water by combining EPA method 300.1 Parts A and B in a single IC run.
- WP-009WP-009Automated determination of major anions and oxyhalides in drinking water using OMNIS IC and single-standard calibration
This white paper demonstrates how OMNIS IC combines high analytical performance with advanced laboratory automation for drinking water analysis.
- AN-CIC-035Halogens and sulfur in solid samples according to EN 17813
Organic halides must be monitored in the environment. Combustion ion chromatography (CIC) is used for accurate halogen analysis in solids following EN 17813:2023.
- AN-CIC-033Monitoring PFASs in water sources
AOF (adsorbable organic fluorine) is used to screen for per- and polyfluorinated alkyl substances in aqueous matrices via pyrohydrolytic combustion and ion chromatography.
- AN-S-403Anions in lithium-ion battery solvents
N-Methylpyrrolidone (NMP) is crucial for lithium-ion battery production. Metrohm’s intelligent Preconcentration Technique with Matrix Elimination enables µg/L-level anion analysis in NMP.
- AN-S-404Water quality testing with EPA 300.1
The Metrosep A Supp 21 column and 948 Continuous IC Module, CEP enable efficient, automated single-run analysis of major anions and disinfection byproducts in water.
- 8.000.60428.000.6042Straightforward multipoint calibration using a single standard
The combination of 850 Professional IC, 858 Professional Sample Processor, Dosino and MagIC NetTM software offers a variety of automated ion chromatographic sample preparation and calibration techniques available as an anion, cation or dual channel system. Calibration is straightforward and requires only one multi-ion standard.Inline calibration allows the calibration of any standard concentration in the ppt range by using one single stable standard solution at the ppb level. By using a preconcentration column and switching the valves one, two or more times different calibration concentrations at the ultra-trace level can be created with unprecedented reproducibility. The inline preconcentration technique uses a pre-concentration column and is ideally suited for trace analysis in complex matrices, especially when combined with matrix elimination. Besides facilitating the preparation of g/L to ng/L calibration graphs Metrohm`s intelligent techniques are capable of logical decision making. While Metrohm`s intelligent Partial Loop technique (MiPT) allows samples with a wide concentration range to be injected without previous manual dilution, the intelligent inline dilution technique, after the first sample injection, compares peak areas, calculates, if necessary, the dilution factor, dilutes and automatically re-injects the sample. The presented inline techniques allow the rationalization of the time-consuming, error-prone and cost-intensive manual preparation of standard solutions. They guarantee that the determined sample concentrations always lie within the calibration range. Higher sample throughputs as well as lower analysis costs and improved data reliability are achieved.
- AN-CIC-034Fast analysis of AOX in waters by CIC
Combustion ion chromatography (CIC) measures AOX (adsorbable organically bound halogens, i.e., AOCl, AOBr, AOI) and AOF as well as CIC AOX(Cl) according to EN ISO 18127.
- AN-D-003Quality control of dialysis concentrates
Ion chromatography (IC) provides an automated, fast, and sensitive solution to accurately quantify cationic and anionic components including acetate simultaneously. This comprehensive approach makes IC an economic alternative to traditional techniques for the quality control of pharmaceutical solutions like haemodialysis concentrates. Ease-of use, accuracy, and the high-throughput of IC increase productivity and comply with the demands of modern routine and research labs.
- AN-S-378AN-S-378Anions in refining process water applying tandem conductivity and UV detection
ASTM D8234 describes the determination of anions in high saline water by applying suppressed conductivity followed by UV/VIS detection. This combination enables the determination of e.g. nitrite by UV detection. With conductivity detection, this quantification is not possible or difficult due to the very large chloride peak. The actual sample is a refining process liquid with a high chloride content. As the sample solution also contains organic material, Inline Dialysis is applied to protect the analytical column. The combination of the two detection modes and the Inline Dialysis option reduces manual sample preparation and substantially increases the accuracy of the analysis.
- AN-Q-008AN-Q-008Trace monitoring in distilled water using ion chromatography
The combination of 940 Professional IC Vario, 942 Extension Module Vario LQH and 941 Eluent Preparation Module enables process monitoring with the aid of ion chromatography. Assigned the designation ProfIC Vario 12 Anion, this combination is the anion variant of Metrohm Process IC. Intelligent preconcentration technology with matrix elimination is used for sample preparation. The use of an ELGA PURELAB® Flex 6 guarantees the supply of ultrapure water of the highest quality, particularly in cases of high numbers of samples.
- AN-S-371AN-S-371Bromate in water with conductivity detection: optimized separation and LOQ
Determination of disinfection byproducts in water is a standard application for ion chromatography. Applying conductivity detection the separation of chlorite and bromate from chloride is crutial for μg/L detection limits. The combination of a Metrosep A Supp 7 - 250/4.0 and a Metrosep A Supp 16 Guard/4.0 lead to an improved separation. The Limit of Quantification for bromate is around 1 μg/L
- AN-Q-005AN-Q-005Online analysis of trace anions in power plant water matrices
A setup that allows online sampling is crucial for immediate and contamination-free analysis of power plant water samples. This application recommends a setup that facilitates simultaneous anion/cation determinations. Automated inline sample preparation combines variable preconcentration (MiPCT) and calibration with a single multi-ion standard. AN-Q-004 displays the respective cation results.
- AN-S-382AN-S-382Metrohm IC Driver for OpenLab CDS: Anion and cation analysis in a soft drink
OpenLab CDS is the newest generation of chromatography data systems from Agilent, combining chromatography and mass spectrometry in a single software platform. The Metrohm IC Driver for OpenLab CDS integrates Metrohm IC instrumentation for full control and data acquisition. The present application describes the simultaneous analysis of anions and cations in a soft drink with a dual channel IC system. Eluent is prepared by applying Inline Eluent Production.
- AN-S-304AN-S-304Variable Inline Preconcentration including Matrix Elimination for trace anion analysis (MiPCT-ME)
Metrohm Inline Preconcentration Technique with Matrix Elimination (MiPCT-ME) is a powerful tool that combines preconcentration, matrix elimination, and multilevel calibration. The latter only requires a single multi-ion standard solution. The 800 Dosino takes over all liquid handling tasks. The shown system setup allows sample analysis from 0.1 µg/L up to 1.0 mg/L.
- AN-S-377AN-S-377Anions in high ionic water by IC using tandem conductivity and UV detection
«High ionic water» is typically water containing a high concentration of chloride (e.g. seawater, brine), but this also describes water samples resulting from petrochemical processes. Due to the high chloride concentrations, the conductivity determination of minor ionic components is limited. Thus, minor anions like nitrite, bromide, and nitrate can elute under or on the tail of the large chloride peak, and their detection in low concentrations is hampered. However, combining conductivity and UV/VIS detection as described in ASTM D8234 enables the determination of anions that are UV active. Chloride does not interfere in this situation. The described technique enables the interference-free simultaneous determination of trace anions besides high chloride content.
- AN-S-301AN-S-301Comprehensive water analysis with VoltIC pro I
VoltIC pro I is the perfect combination of voltammetry and ion chromatography for the fully automated analysis of anions, cations, and heavy metals (e.g., Zn, Cd, Pb, Cu): comprehensive water analysis on a single system.
- AN-S-387AN-S-387Comprehensive water analysis with TitrIC flex II
The TitrIC flex II system is the perfect combination of titration, direct measurement, and ion chromatography for fully automated analysis of all key parameters. These include pH, conductivity, hardness, anions, cations, as well as the calculation of the ion balance: comprehensive water analysis from one system.
- AN-S-347AN-S-347Comprehensive water analysis with VoltIC Professional 1
VoltIC Professional 1 is the perfect combination of voltammetry and ion chromatography for the fully automated, simultaneous analysis of anions, cations, and heavy metals (e.g., Zn, Cd, Pb, Cu). The multiple-parameter analysis uses the same "Liquid Handling" elements and a shared sample changer, thus saving on space and costs.
- 8.000.60128.000.6012Automated logical dilution for ion chromatographic determinations
The combination of 850 Professional IC, 858 Professional Sample Processor, Dosino and MagIC NetTM software offers a variety of sophisticated ion chromatographic sample preparation techniques. One of these is the automated inline dilution of samples.After the first sample injection, MagIC NetTM verifies if the area of the sample peak lies within the calibration range. If the measured peak area is outside these limits, the software calculates the appropriate dilution factor, dilutes and automatically re-injects the sample. For all investigated ions (Li+, Na+, K+, Ca2+, Mg2+, F-, Cl- , NO2-, Br-, NO3-, SO42- ), automated logical dilution yielded coefficients of determination (R2) better than 0.9999. Direct-injection recoveries for cations and anions were within 98.6…99.5% and 93.4…100.4% respectively. In contrast, after logical dilution, recoveries for cations and anions were within 100.1…102.9% and 98.2…102.6% respectively. The relative standard deviations for all determinations involving diluted sample solutions were smaller than 0.91%.
- AN-H-127Thermometric analysis of aluminum by back-titration
This Application Note describes the determination of aluminum in samples containing silicon dioxide using thermometric titration and EDTA as the titrant. Excess EDTA is titrated with a Cu2+ solution of known concentration. The initial, uncomplexed Cu2+ ions react immediately with the H2O2 present in the solution, leading to a recognizable sudden increase in temperature.
- AN-D-001Metrohm IC Driver for OpenLab CDS
This application focuses on the simultaneous analysis of cations and suppressed anions with a dual channel Metrohm IC operated by OpenLab CDS.
- AN-M-015Trace haloacetic acids, dalapon, and bromate measurement in drinking water
Chlorinating drinking water can form carcinogenic byproducts. EPA Method 557 enables µg/L-level quantification of haloacetic acids using Metrohm IC-MS/MS technology.
6.00500.600
Combined F-ISE with Pt1000Combined fluoride-selective electrode with crystal membrane with integrated Pt1000 temperature sensor.This ISE is suitable for: Ion measurements of F- ; Automated ion measurements; Titrations; Reference electrolyte: c(KCl) = 3 mol/LThe electrode is stored in the reference electrolyte.
6.00500.300
Combined dF-ISE with Pt1000Combined digital fluoride-selective electrode with crystal membrane for OMNIS Software with integrated Pt1000 temperature sensor. This ISE is suitable for: Ion measurements of F-; Automated ion measurements; Titrations; Reference electrolyte: c(KCl) = 3 mol/LThe electrode is stored in the reference electrolyte. dTrodes can be used on OMNIS Titrators.
6.0502.150
Ion-selective electrode, FFluoride-selective electrode with crystal membrane.This ISE has to be used in combination with a reference electrode and is suitable for:ion measurements of F- ; ion measurements in small sample volumes (minimum immersion depth 1 mm); titrations; Thanks to the robust/break-proof plastic shaft made of EP, this sensor is mechanically very resistant.
- Feb 21, 2022Ion selective electrodes general tips Part 1
Theory of ion measurement, types of ion-selective electrodes, why using TISAB or ISA solution for measuring ions, and more on our blog.
- May 16, 2022History of Metrohm IC – Part 6
Blog post on the history of combustion ion chromatography from Metrohm for sulfur and halogen determination.
- May 6, 2024Advancing precision and efficiency in ion chromatography with automated inline dilution
Fully automated solutions for ion chromatography like the Metrohm Inline Dilution Technique (MIDT) streamline sample preparation and ensure precise results.
- Nov 18, 2024Ion chromatography for the pharmaceutical industry
The principles of ion chromatography are introduced, then some applications and benefits of using IC for pharma analysis according to USP General Chapter <1065>.
- Sep 28, 2026Detection methods in ion chromatography: a comprehensive overview
This article reviews several detection techniques used in ion chromatography (IC) for the separation and quantification of ionic species, including non-suppressed and suppressed conductivity, UV/VIS, and amperometric detection.
- Sep 14, 2020History of Metrohm IC – Part 3
Blog post on Metrohm ion chromatography and the introduction of sequential suppression for increased sensitivity in ion chromatographic analysis.
- Sep 23, 2024Quality control of cathode materials
This article highlights several key parameters crucial for Li-ion battery cathode production quality and efficient recycling and the methods to analyze them.
- Nov 8, 2021Guide to online and inline surface finishing analysis
Online and inline surface finishing analysis for construction, automotive, semiconductor, and aerospace industries.
- Aug 23, 2021Best practice for separation columns in ion chromatography (IC) – Part 1
Blog on how to handle IC separation columns: standard operating conditions, equilibration, operating limits, and more.
6.01034.220
Metrosep A Supp 19 - 150/2.0The Metrosep A Supp 19 - 150/2.0 combines the outstanding separation performance of the Metrosep A Supp 19 stationary phase with the efficiency advantages of a 2 mm microbore format. It delivers excellent selectivity, sharp peak shapes, and high capacity, enabling precise quantification of both standard anions and organic acids, even in demanding sample matrices. Owing to its reduced eluent consumption and inherently low flow rates, the 150/2.0 version is particularly well suited for IC–MS coupling, offering enhanced sensitivity and reduced background noise in mass‑spectrometric detection.Built on the proven mechanical, thermal, and chemical stability of the Metrosep A Supp 19 packing material, this column maintains outstanding robustness even at elevated pressures and varying eluent conditions. Its narrow‑bore design ensures highly efficient separations, while still providing the high anion‑exchange capacity required for accurate analyses across a wide concentration range.In addition to its suitability for classical water and environmental analysis, the Metrosep A Supp 19 - 150/2.0 is an excellent choice for air‑monitoring applications, including fully automated systems such as MARGA (Monitor for Aerosols and Gases in Ambient Air) and MARS (Metrohm AeRosol Sampler). The combination of high separation efficiency, low flow requirements, and stable baseline performance makes this column ideal for continuous, high‑precision monitoring of atmospheric anions.
6.01034.230
Metrosep A Supp 19 - 250/2.0The Metrosep A Supp 19 - 250/2.0 is the high‑capacity variant of the Metrosep A Supp 19 microbore family. Building on the excellent selectivity and peak symmetry that characterize the Metrosep A Supp 19 stationary phase, this extended‑length 2 mm column provides substantially increased capacity, enabling reliable separation and quantification in highly complex sample matrices. Its narrow‑bore design ensures efficient separations with low eluent consumption, while the longer format delivers enhanced resolution for challenging analyte combinations.Thanks to its increased capacity, the Metrosep A Supp 19 - 250/2.0 excels in applications where the 150/2.0 version reaches its limits, such as environmental samples with substantial matrix loads, industrial wastewaters, or samples containing both standard anions and organic acids across broad concentration ranges. The extended column length ensures superior separation power and reliable performance, even when confronted with heavy matrix interferences.With inherently low flow rates, the Metrosep A Supp 19 - 250/2.0 is also particularly well suited for IC-MS coupling. The microbore format reduces background noise and enhances sensitivity in mass‑spectrometric detection, making this column a strong choice for laboratories requiring trace‑level quantification, high selectivity, and stable baselines.
6.1006.230
Metrosep A Supp 5 - 250/2.0The Metrosep A Supp 5 - 250/2.0 is the microbore high-performance separation column with which even complex separation problems can be solved easily and reproducibly. The range of applications possible with this column far exceeds the detection of standard anions. The Metrosep A Supp 5 - 250/2.0 is used wherever maximum separating efficiency must be combined with both the lowest of detection limits and low eluent consumption.With its low eluent flow, this column is particularly suitable for IC-MS coupling.
6.1006.520
Metrosep A Supp 5 - 150/4.0The 150 mm version of the Metrosep A Supp 5 is distinguished by its very good separation properties. High plate numbers and excellent peak symmetries facilitate working in the lower µg/L range. The particle size of 5 µm makes a decisive contribution to the separating efficiency of this column. The Metrosep A Supp 5 - 150/4.0 offers the optimum combination of selectivity and capacity, with which even complex separation tasks can be solved within a short time. This property makes the Metrosep A Supp 5 - 150/4.0 one of the best universally applicable standard IC columns.
6.1006.220
Metrosep A Supp 5 - 150/2.0The Metrosep A Supp 5 - 150 in the Microbore version is distinguished for its excellent separation properties. The particle size of 5 µm makes a decisive contribution to the separating efficiency of this column. The Metrosep A Supp 5 - 150/2.0 offers the optimum combination of selectivity and capacity, with which even complex separation tasks can be solved within a short time. The 2 mm Metrosep A Supp 5 separation columns are packed with the same material as the corresponding 4 mm separation columns. The 150 mm version of this column type is used for universal applications at low eluent consumption.With its low eluent flow, this column is particularly suitable for IC-MS coupling.
- Jun 14, 2022Monitoring fluoride in drinking water
- Jan 5, 2022Quality control and optimization of coating processes using ion chromatography (IC)
Impurities can have detrimental effects for example on the electrical properties of integrated circuits and final products in the semiconductor industry. Ion chromatography (IC) is the ideal method for analyzing ionic impurities, even in the ng/L range.
- Jan 10, 2022Quality control and optimization of coating processes in chrome plating
- Sep 21, 2021Fluoride Ion Selective Electrode (ISE) launched
The new Fluoride ISE from Metrohm combines the measuring electrode, the reference electrode, and a temperature sensor in a space saving design. The fluoride electrode is ideal for measurements in small sample volumes.