Chuyển hướng tin nhắn
Separate pH glass electrode

Separate pH glass electrode

6.0150.100

Separate pH glass electrode

vi

6.0150.100

Tổng quan

pH glass electrode for aqueous pH measurements or differential potentiometry in non-aqueous media. This pH electrode has to be used in combination with a reference electrode.
- Optimized length for sample changer applications
- Electrically shielded
- Blue T-glass for reliable results
Storage in deion. water.

Thông số kỹ thuật

Shaft materialGlass
Measuring unitpH
Temperature range, long-term (°C)0...80
Temperature range, short-term (°C)0...80
pH range0...14
Max. installation length (mm)142
SGJ sleeveFlexible SGJ sleeve
Shaft diameter top (mm)12
Shaft diameter bottom (mm)12
Min. immersion depth (mm)15
Electrode plug-in headMetrohm plug-in head G
Indicator electrode typeGlass electrode
Indicator electrode shapeSphere
Membrane glass typeT
Membrane resistance40 ... 150
Electrode zero point (mV)± 15
Electrode slope>0.97
Asymmetry potential± 15
This field is required.
    • Sleeve with SGJ 14/12 mm
    • 6.1236.050
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • PCS
    • 1
    • Storage vessel 
    • 6.2008.040
    • Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
    • <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
    • PCS
    • 1
    • Sleeve with SGJ 14/12 mm
    • 6.1236.050
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • PCS
    • 1
    • Storage vessel 
    • 6.2008.040
    • Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
    • <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
    • PCS
    • 1
    • Ag/AgCl reference electrode (length 12.5 cm)
    • 6.0726.100
    • Silver/silver chloride reference electrode with Double-Junction System, installation length 10 cm.The standard ground-joint 14/15 enables easy assembly, and the flexible ground-joint diaphragm, which is insensitive to contamination, can be replaced at any time. The reference electrolyte and the bridge electrolyte can be selected freely according to use, and are easy to replace. This sensor is supplied without electrolyte filling.
    • <p>Silver/silver chloride reference electrode with Double-Junction System, installation length 10 cm.<br/>The standard ground-joint 14/15 enables easy assembly, and the flexible ground-joint diaphragm, which is insensitive to contamination, can be replaced at any time. The reference electrolyte and the bridge electrolyte can be selected freely according to use, and are easy to replace. This sensor is supplied without electrolyte filling.</p>
    • PCS
    • 1
    • LL ISE reference electrode
    • 6.0750.100
    • Silver / silver chloride reference electrode with double junction system.This reference electrode is well suited for:automated applications; ion measurements; surfactant titrations; The ground-joint diaphragm, which is insensitive to contamination, offers a constant and reproducible electrolyte outflow. Additionally, the reference electrolyte is gelified for even better signal stability. The sensor is delivered with c(KCl) = 3 mol/L as bridge electrolyte, which can be freely selected and exchanged as needed.
    • <p>Silver / silver chloride reference electrode with double junction system.<br/>This reference electrode is well suited for:</p><ul><li>automated applications</li><li>ion measurements</li><li>surfactant titrations</li></ul><p>The ground-joint diaphragm, which is insensitive to contamination, offers a constant and reproducible electrolyte outflow. Additionally, the reference electrolyte is gelified for even better signal stability. The sensor is delivered with c(KCl) = 3 mol/L as bridge electrolyte, which can be freely selected and exchanged as needed.</p>
    • PCS
    • 1
    • Electrode cable / 1 m / F
    • 6.2104.020
    • For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
    • For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
    • PCS
    • 1