Chuyển hướng tin nhắn
Combined F-ISE with Pt1000

Combined F-ISE with Pt1000

6.00500.600

Combined F-ISE with Pt1000

vi

6.00500.600

Tổng quan

Combined fluoride-selective electrode with crystal membrane with integrated Pt1000 temperature sensor.
This ISE is suitable for:
 

  • Ion measurements of F- (10-6 mol/L to sat.)
  • Automated ion measurements
  • Titrations


Reference electrolyte: c(KCl) = 3 mol/L
The electrode is stored in the reference electrolyte.

Thông số kỹ thuật

SGJ sleeveFlexible
Shaft material (completion)Fiberglass-reinforced epoxy
Resistance (kOhm)5
Shaft materialGlass
Measuring range (theoretical)1x10-6...sat.
Measuring unitmol/L
Temperature range, long-term (°C)0...40
Temperature range, short-term (°C)0...50
pH range5...7
Max. installation length (mm)125
Shaft diameter top (mm)12
Shaft diameter bottom (mm)6
Min. immersion depth (mm)20
Electrode plug-in headMetrohm plug-in head U
Indicator electrode typeCrystal (F)
DiaphragmGround-joint diaphragm
Reference electrolyte typec(KCl) = 3 mol/L
Reference systemAg/AgCl/3M KCl
Membrane materialCrystal
IonF-
Indicator electrode shapeFlat
This field is required.
    • Sleeve with SGJ 14/12 mm
    • 6.1236.050
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Stk
    • 100
    • Storage vessel 
    • 6.2008.040
    • Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
    • <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
    • Stk
    • 100
    • Sleeve with SGJ 14/12 mm
    • 6.1236.050
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Stk
    • 100
    • Storage vessel 
    • 6.2008.040
    • Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
    • <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
    • Stk
    • 100
    • Electrode cable plug-in head U / plug P, 0.55 m
    • 6.02104.600
    • Cable for connecting an electrode with plug-in head U to an analog measuring module from OMNIS.
    • <p>Cable for connecting an electrode with plug-in head U to an analog measuring module from OMNIS.</p>
    • PCS
    • 1
    • Electrode cable plug-in head U / plug P, 1.5 m
    • 6.02104.610
    • Cable for connecting an electrode with plug-in head U to an analog measuring module from OMNIS.
    • <p>Cable for connecting an electrode with plug-in head U to an analog measuring module from OMNIS.</p>
    • PCS
    • 1
    • Electrolyte 3 mol/L KCl (250 mL)
    • 6.2308.020
    • Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
    • Electrolyte solution c(KCl) &#61; 3 mol/L, (for Ag/AgCl reference systems)
    • PCS
    • 1