Chuyển hướng tin nhắn
895 Professional PVC Thermomat

895 Professional PVC Thermomat

2.895.0010

    • Polystyrene measuring vessel for stability measurements
    • 6.1428.107
    • Conductivity measuring vessel, made of polystyrene, for stability measuring instruments. Set of 50 pieces.
    • <p>Conductivity measuring vessel, made of polystyrene, for stability measuring instruments. Set of 50 pieces.</p>
    • PCS
    • 1
    • Reaction vessel short for stability measurements
    • 6.1429.040
    • Reaction vessel for stability measurements with Rancimat and PVC Thermomat. Set of 117 pieces.
    • <p>Reaction vessel for stability measurements with Rancimat and PVC Thermomat. Set of 117 pieces.</p>
    • PCS
    • 1
    • O-Ring
    • 6.1454.040
    • O-ring for air tube for stability measurements. Set of 8 pieces.
    • <p>O-ring for air tube for stability measurements. Set of 8 pieces.</p>
    • PCS
    • 4
    • Tubing adapter olive / M6 inner
    • 6.1808.020
    • 1 M6 inner thread and 1 tubing nozzle. Part of the screw connections for Exchange Units and stability measuring instruments.
    • 1 M6 inner thread and 1 tubing nozzle. Part of the screw connections for Exchange Units and stability measuring instruments.
    • PCS
    • 1
    • Tubing adapter olive / M8 outer
    • 6.1808.050
    • 1 M8 outer thread and 1 tubing olive. E.g. for thermostat jacket of exchange units and stability measuring instruments.
    • 1 M8 outer thread and 1 tubing olive. E.g. for thermostat jacket of exchange units and stability measuring instruments.
    • PCS
    • 16
    • Thread adapter M8 outer / M6 inner
    • 6.1808.090
    • Outer thread M8, inner thread M6, e.g. for mounting 6.2418.XXX Air tubes in 6.1429.XXX Reaction vessels of stability measuring instruments.
    • Outer thread M8, inner thread M6, e.g. for mounting 6.2418.XXX Air tubes in 6.1429.XXX Reaction vessels of stability measuring instruments.
    • PCS
    • 8
    • Silicone tubing 0.22 m
    • 6.1816.010
    • Connection tubing for stability measuring instruments.
    • Connection tubing for stability measuring instruments.
    • PCS
    • 24
    • Cannula for gas feeding
    • 6.1819.080
    • For stability measuring instruments.
    • For stability measuring instruments.
    • PCS
    • 8
    • Holder for reaction vessels
    • 6.2041.190
    • Reaction vessel holder for stability instruments; for 8 reaction vessels.
    • Reaction vessel holder for stability instruments; for 8 reaction vessels.
    • PCS
    • 1
    • Labels laminated
    • 6.2250.000
    • Labels for measuring vessel cover for stability measuring instruments. Labeling: A1, A2, A3, A4, B1, B2, B3, B4. 5 sets of 8 items each.
    • Labels for measuring vessel cover for stability measuring instruments. Labeling: A1, A2, A3, A4, B1, B2, B3, B4. 5 sets of 8 items each.
    • PCS
    • 1
    • Holder for reaction vessel
    • 6.2628.000
    • Reaction vessel holder for stability instruments; for 1 reaction vessel for weighing in the sample.
    • Reaction vessel holder for stability instruments; for 1 reaction vessel for weighing in the sample.
    • PCS
    • 1
    • 895 Professional PVC Thermomat
    • 1.895.0010
    • The 895 Professional PVC Thermomat is an analysis system for the automatic determination of the thermostability of polyvinyl chloride (PVC) and related copolymers. With eight measuring positions in two heating blocks. The built-in display shows the status of the instrument and each individual measuring position. Start buttons for every measuring position enable the measurement start on the instrument. Cleaning effort can be reduced to a minimum through the use of practical disposable reaction vessels and dishwasher-safe accessories. This saves time and costs and significantly improves accuracy and reproducibility.All accessories necessary for carrying out determinations are included in the scope of delivery. The StabNet software is required for instrument control, data recording and evaluation and for data storage.
    • <p>The 895 Professional PVC Thermomat is an analysis system for the automatic determination of the thermostability of polyvinyl chloride (PVC) and related copolymers. With eight measuring positions in two heating blocks. The built-in display shows the status of the instrument and each individual measuring position. Start buttons for every measuring position enable the measurement start on the instrument. Cleaning effort can be reduced to a minimum through the use of practical disposable reaction vessels and dishwasher-safe accessories. This saves time and costs and significantly improves accuracy and reproducibility.</p><p>All accessories necessary for carrying out determinations are included in the scope of delivery. The StabNet software is required for instrument control, data recording and evaluation and for data storage. </p>
    • PCS
    • 1
    • Polystyrene measuring vessel for stability measurements
    • 6.1428.107
    • Conductivity measuring vessel, made of polystyrene, for stability measuring instruments. Set of 50 pieces.
    • <p>Conductivity measuring vessel, made of polystyrene, for stability measuring instruments. Set of 50 pieces.</p>
    • PCS
    • 1
    • Reaction vessel short for stability measurements
    • 6.1429.040
    • Reaction vessel for stability measurements with Rancimat and PVC Thermomat. Set of 117 pieces.
    • <p>Reaction vessel for stability measurements with Rancimat and PVC Thermomat. Set of 117 pieces.</p>
    • PCS
    • 1
    • O-Ring
    • 6.1454.040
    • O-ring for air tube for stability measurements. Set of 8 pieces.
    • <p>O-ring for air tube for stability measurements. Set of 8 pieces.</p>
    • PCS
    • 4
    • Tubing adapter olive / M6 inner
    • 6.1808.020
    • 1 M6 inner thread and 1 tubing nozzle. Part of the screw connections for Exchange Units and stability measuring instruments.
    • 1 M6 inner thread and 1 tubing nozzle. Part of the screw connections for Exchange Units and stability measuring instruments.
    • PCS
    • 1
    • Tubing adapter olive / M8 outer
    • 6.1808.050
    • 1 M8 outer thread and 1 tubing olive. E.g. for thermostat jacket of exchange units and stability measuring instruments.
    • 1 M8 outer thread and 1 tubing olive. E.g. for thermostat jacket of exchange units and stability measuring instruments.
    • PCS
    • 16
    • Thread adapter M8 outer / M6 inner
    • 6.1808.090
    • Outer thread M8, inner thread M6, e.g. for mounting 6.2418.XXX Air tubes in 6.1429.XXX Reaction vessels of stability measuring instruments.
    • Outer thread M8, inner thread M6, e.g. for mounting 6.2418.XXX Air tubes in 6.1429.XXX Reaction vessels of stability measuring instruments.
    • PCS
    • 8
    • Silicone tubing 0.22 m
    • 6.1816.010
    • Connection tubing for stability measuring instruments.
    • Connection tubing for stability measuring instruments.
    • PCS
    • 24
    • Cannula for gas feeding
    • 6.1819.080
    • For stability measuring instruments.
    • For stability measuring instruments.
    • PCS
    • 8
    • Holder for reaction vessels
    • 6.2041.190
    • Reaction vessel holder for stability instruments; for 8 reaction vessels.
    • Reaction vessel holder for stability instruments; for 8 reaction vessels.
    • PCS
    • 1
    • Labels laminated
    • 6.2250.000
    • Labels for measuring vessel cover for stability measuring instruments. Labeling: A1, A2, A3, A4, B1, B2, B3, B4. 5 sets of 8 items each.
    • Labels for measuring vessel cover for stability measuring instruments. Labeling: A1, A2, A3, A4, B1, B2, B3, B4. 5 sets of 8 items each.
    • PCS
    • 1
    • Holder for reaction vessel
    • 6.2628.000
    • Reaction vessel holder for stability instruments; for 1 reaction vessel for weighing in the sample.
    • Reaction vessel holder for stability instruments; for 1 reaction vessel for weighing in the sample.
    • PCS
    • 1
    • Pt100 temperature sensor for stability measuring devices
    • 6.1111.010
    • Pt100 temperature sensor (length 17.5 cm) with fixed cable and mini-DIN-plug. This glass-free temperature sensor is well suited for use with a 711 Liquino and instruments for stability measurement (743 Rancimat, 763 PVC Thermomat, 892 Professional Rancimat, or 895 Professional PVC Thermomat).
    • <p>Pt100 temperature sensor (length 17.5 cm) with fixed cable and mini-DIN-plug. This glass-free temperature sensor is well suited for use with a 711 Liquino and instruments for stability measurement (743 Rancimat, 763 PVC Thermomat, 892 Professional Rancimat, or 895 Professional PVC Thermomat).</p>
    • PCS
    • 1
    • Turning ring
    • 6.2059.000
    • Turning ring for the swiveling setup of stability measuring instruments.
    • Turning ring for the swiveling setup of stability measuring instruments.
    • PCS
    • 1
    • Conductivity standard 100 µS/cm 250 mL
    • 6.2324.010
    • Conductivity standard for calibration of conductivity measuring cells with cell constant = 0.1/cm.
    • Conductivity standard for calibration of conductivity measuring cells with cell constant = 0.1/cm.
    • PCS
    • 1
    • Sleeve set conductivity stability (8x)
    • 6.2771.000
    • Sleeve set for measuring vessel cover for stability measurement devices in PP.
    • <p>Sleeve set for measuring vessel cover for stability measurement devices in PP.</p>
    • PCS
    • 1