Chuyển hướng tin nhắn
Eco Coulometer with generator electrode without diaphragm

Eco Coulometer with generator electrode without diaphragm

2.1028.0110

    • Electrode cable plug-in head G (pol.) / plug P, 0.55 m
    • 6.02104.040
    • Cable for connecting an analog polarizable electrode (plug-in head G) to an analog measuring module from OMNIS.
    • <p>Cable for connecting an analog polarizable electrode (plug-in head G) to an analog measuring module from OMNIS.</p>
    • PCS
    • 1
    • Stylus - Metrohm
    • 6.02201.001
    • Stylus for instruments with touch user interface
    • <p> Stylus for instruments with touch user interface</p>
    • PCS
    • 1
    • Cotton for adsorber tube
    • 6.02801.000
    • Wad of cotton (4 pieces), suitable for OMNIS 601406010 adsorber tube.
    • <p>Wad of cotton (4 pieces), suitable for OMNIS 601406010 adsorber tube.</p>
    • PCS
    • 1
    • Double Pt-wire electrode for coulometry
    • 6.0341.100
    • Indicator electrode used for coulometric Karl Fischer titration.
    • <p>Indicator electrode used for coulometric Karl Fischer titration.</p>
    • PCS
    • 1
    • Generator electrode without diaphragm
    • 6.0345.100
    • Generator electrode without diaphragm for coulometric Karl Fischer titrations, SGJ 29/22. This generator electrode is well suited for most applications where the sample is highly soluble in alcohol.
    • <p>Generator electrode without diaphragm for coulometric Karl Fischer titrations, SGJ 29/22. This generator electrode is well suited for most applications where the sample is highly soluble in alcohol.</p>
    • PCS
    • 1
    • Stirring bar / 25 mm
    • 6.1903.030
    • Stirring bar with magnetic core, PTFE covering, length 25 mm.
    • <p>Stirring bar with magnetic core, PTFE covering, length 25 mm.</p>
    • PCS
    • 1
    • Titration vessel holder for 899/917
    • 6.2047.040
    • Titration vessel holder for coulometric cells for 899 Coulometer and 917 Ti-Touch
    • <p>Titration vessel holder for coulometric cells for 899 Coulometer and 917 Ti-Touch</p>
    • PCS
    • 1
    • Electrode cable / 1 m / H
    • 6.2104.120
    • With plug H. For connecting generator electrode - KF Coulometer.
    • With plug H. For connecting generator electrode - KF Coulometer.
    • PCS
    • 1
    • Power supply unit 100 - 240 V/24 V DC
    • 6.2164.010
    • Power supply unit for 915 KF Ti-Touch, 916 Ti-Touch, 917 Coulometer and all Eco Titrators / Eco Dosimat.
    • <p>Power supply unit for 915 KF Ti-Touch, 916 Ti-Touch, 917 Coulometer and all Eco Titrators / Eco Dosimat.</p>
    • PCS
    • 1
    • GL 18 screw cap with hole
    • 6.2701.040
    • Made of PBT. With a hole for the 6.1448.020 septum. For the 6.5405.000 cell without diaphragm and the 6.1464.32X and 6.1465.320 titration vessels.
    • Made of PBT. With a hole for the 6.1448.020 septum. For the 6.5405.000 cell without diaphragm and the 6.1464.32X and 6.1465.320 titration vessels.
    • PCS
    • 1
    • PTFE sleeve SGJ14
    • 6.2713.000
    • For fat-free ground-joint connection with the standard ground-joint SGJ 14.
    • <p>For fat-free ground-joint connection with the standard ground-joint SGJ 14.</p>
    • PCS
    • 2
    • PTFE sleeve SGJ29
    • 6.2713.010
    • Sleeve for fat-free ground-joint connection with the standard ground-joint SGJ 29.
    • <p>Sleeve for fat-free ground-joint connection with the standard ground-joint SGJ 29.</p>
    • PCS
    • 1
    • PTFE sleeve SGJ19
    • 6.2713.020
    • For fat-free ground-joint connection with the standard ground-joint SGJ 19.
    • <p>For fat-free ground-joint connection with the standard ground-joint SGJ 19.</p>
    • PCS
    • 1
    • Funnel
    • 6.2738.000
    • For the KF coulometer.
    • <p>For the KF coulometer.</p>
    • PCS
    • 1
    • Molecular sieve
    • 6.2811.000
    • Molecular sieve. Bottle containing 250 g. Pore size: 0.3 nm. Without moisture indicator. For Rancimats and Karl Fischer instruments.
    • Molecular sieve. Bottle containing 250 g. Pore size: 0.3 nm. Without moisture indicator. For Rancimats and Karl Fischer instruments.
    • PCS
    • 1
    • Needle with Luer connector
    • 6.2816.030
    • Needle for filling in mercury into the Multi-Mode Electrode and for sample addition in Karl Fischer titration. 
    • <p>Needle for filling in mercury into the Multi-Mode Electrode and for sample addition in Karl Fischer titration.</p> <p> </p>
    • PCS
    • 2
    • Syringe 5 mL
    • 6.2816.090
    • 5 mL syringe made of PP, with Luer connector.
    • <p>5 mL syringe made of PP, with Luer connector.</p>
    • PCS
    • 2
    • Eco Coulometer
    • 1.1028.0010
    • The Eco Coulometer with integrated magnetic stirrer and touch-sensitive display is ideal for water content determination in the 10 µg to 200 mg absolute water range. Predefined methods enable a smooth and easy instrument start-up. In addition to GLP-compliant printouts on paper or as PDFs, the Eco Coulometer also offers the option of being able to connect balances or send determination data to a PC via PC / LIMS reports. Indicator electrode and generator electrode with diaphragm are included in the scope of delivery.Coulometry is the ideal method for water content determination in the trace range in liquids, solids and gases. In addition, coulometry is an absolute method making titer determination unnecessary.
    • <p>The Eco Coulometer with integrated magnetic stirrer and touch-sensitive display is ideal for water content determination in the 10 µg to 200 mg absolute water range. Predefined methods enable a smooth and easy instrument start-up. In addition to GLP-compliant printouts on paper or as PDFs, the Eco Coulometer also offers the option of being able to connect balances or send determination data to a PC via PC / LIMS reports. Indicator electrode and generator electrode with diaphragm are included in the scope of delivery.<br/>Coulometry is the ideal method for water content determination in the trace range in liquids, solids and gases. In addition, coulometry is an absolute method making titer determination unnecessary.</p>
    • PCS
    • 1
    • Electrode cable plug-in head G (pol.) / plug P, 0.55 m
    • 6.02104.040
    • Cable for connecting an analog polarizable electrode (plug-in head G) to an analog measuring module from OMNIS.
    • <p>Cable for connecting an analog polarizable electrode (plug-in head G) to an analog measuring module from OMNIS.</p>
    • PCS
    • 1
    • Stylus - Metrohm
    • 6.02201.001
    • Stylus for instruments with touch user interface
    • <p> Stylus for instruments with touch user interface</p>
    • PCS
    • 1
    • Cotton for adsorber tube
    • 6.02801.000
    • Wad of cotton (4 pieces), suitable for OMNIS 601406010 adsorber tube.
    • <p>Wad of cotton (4 pieces), suitable for OMNIS 601406010 adsorber tube.</p>
    • PCS
    • 1
    • Double Pt-wire electrode for coulometry
    • 6.0341.100
    • Indicator electrode used for coulometric Karl Fischer titration.
    • <p>Indicator electrode used for coulometric Karl Fischer titration.</p>
    • PCS
    • 1
    • Generator electrode without diaphragm
    • 6.0345.100
    • Generator electrode without diaphragm for coulometric Karl Fischer titrations, SGJ 29/22. This generator electrode is well suited for most applications where the sample is highly soluble in alcohol.
    • <p>Generator electrode without diaphragm for coulometric Karl Fischer titrations, SGJ 29/22. This generator electrode is well suited for most applications where the sample is highly soluble in alcohol.</p>
    • PCS
    • 1
    • Stirring bar / 25 mm
    • 6.1903.030
    • Stirring bar with magnetic core, PTFE covering, length 25 mm.
    • <p>Stirring bar with magnetic core, PTFE covering, length 25 mm.</p>
    • PCS
    • 1
    • Titration vessel holder for 899/917
    • 6.2047.040
    • Titration vessel holder for coulometric cells for 899 Coulometer and 917 Ti-Touch
    • <p>Titration vessel holder for coulometric cells for 899 Coulometer and 917 Ti-Touch</p>
    • PCS
    • 1
    • Electrode cable / 1 m / H
    • 6.2104.120
    • With plug H. For connecting generator electrode - KF Coulometer.
    • With plug H. For connecting generator electrode - KF Coulometer.
    • PCS
    • 1
    • Power supply unit 100 - 240 V/24 V DC
    • 6.2164.010
    • Power supply unit for 915 KF Ti-Touch, 916 Ti-Touch, 917 Coulometer and all Eco Titrators / Eco Dosimat.
    • <p>Power supply unit for 915 KF Ti-Touch, 916 Ti-Touch, 917 Coulometer and all Eco Titrators / Eco Dosimat.</p>
    • PCS
    • 1
    • GL 18 screw cap with hole
    • 6.2701.040
    • Made of PBT. With a hole for the 6.1448.020 septum. For the 6.5405.000 cell without diaphragm and the 6.1464.32X and 6.1465.320 titration vessels.
    • Made of PBT. With a hole for the 6.1448.020 septum. For the 6.5405.000 cell without diaphragm and the 6.1464.32X and 6.1465.320 titration vessels.
    • PCS
    • 1
    • PTFE sleeve SGJ14
    • 6.2713.000
    • For fat-free ground-joint connection with the standard ground-joint SGJ 14.
    • <p>For fat-free ground-joint connection with the standard ground-joint SGJ 14.</p>
    • PCS
    • 2
    • PTFE sleeve SGJ29
    • 6.2713.010
    • Sleeve for fat-free ground-joint connection with the standard ground-joint SGJ 29.
    • <p>Sleeve for fat-free ground-joint connection with the standard ground-joint SGJ 29.</p>
    • PCS
    • 1
    • PTFE sleeve SGJ19
    • 6.2713.020
    • For fat-free ground-joint connection with the standard ground-joint SGJ 19.
    • <p>For fat-free ground-joint connection with the standard ground-joint SGJ 19.</p>
    • PCS
    • 1
    • Funnel
    • 6.2738.000
    • For the KF coulometer.
    • <p>For the KF coulometer.</p>
    • PCS
    • 1
    • Molecular sieve
    • 6.2811.000
    • Molecular sieve. Bottle containing 250 g. Pore size: 0.3 nm. Without moisture indicator. For Rancimats and Karl Fischer instruments.
    • Molecular sieve. Bottle containing 250 g. Pore size: 0.3 nm. Without moisture indicator. For Rancimats and Karl Fischer instruments.
    • PCS
    • 1
    • Needle with Luer connector
    • 6.2816.030
    • Needle for filling in mercury into the Multi-Mode Electrode and for sample addition in Karl Fischer titration. 
    • <p>Needle for filling in mercury into the Multi-Mode Electrode and for sample addition in Karl Fischer titration.</p> <p> </p>
    • PCS
    • 2
    • Syringe 5 mL
    • 6.2816.090
    • 5 mL syringe made of PP, with Luer connector.
    • <p>5 mL syringe made of PP, with Luer connector.</p>
    • PCS
    • 2
    • Solvent Pump
    • 2.1029.0010
    • Solvent Pump is used with an Eco Titrator / Eco KF Titrator / Eco Coulometer for reliably adding solvent and aspirating off titration vessel content without contact with the reagents.Device-independent use is also possible with optional 6.2164.010 power supply unit.
    • <p>Solvent Pump is used with an Eco Titrator / Eco KF Titrator / Eco Coulometer for reliably adding solvent and aspirating off titration vessel content without contact with the reagents.</p><p>Device-independent use is also possible with optional 6.2164.010 power supply unit.</p>
    • PCS
    • 1
    • TX-900MH impact printer
    • 2.143.0200
    • Compact impact printer with USB and RS232 interface for 900 Touch Control (+); 915 KF Ti-Touch (+); 916 Ti-Touch (+); 917 Coulometer (+); 91X Meter (+)Eco Dosimat/Titrator (+); 877/848 Titrino plus (additional 6.2151.100 required); 865/876 Dosimat plus (additional 6.2151.100 required); 862 Compact Titrosampler (additional 6.2151.100 required); 870 KF Titrino plus (additional 6.2151.100 required); 899 Coulometer (additional 6.2151.100 required);  (+) Cable included in scope of delivery
    • <p> Compact impact printer with USB and RS232 interface for </p><ul><li>900 Touch Control (+)</li><li>915 KF Ti-Touch (+)</li><li>916 Ti-Touch (+)</li><li>917 Coulometer (+)</li><li>91X Meter (+)<br/>Eco Dosimat/Titrator (+)</li><li>877/848 Titrino plus (additional 6.2151.100 required)</li><li>865/876 Dosimat plus (additional 6.2151.100 required)</li><li>862 Compact Titrosampler (additional 6.2151.100 required)</li><li>870 KF Titrino plus (additional 6.2151.100 required)</li><li>899 Coulometer (additional 6.2151.100 required)</li></ul><p> </p><p>(+) Cable included in scope of delivery</p>
    • PCS
    • 1
    • 860 KF Thermoprep
    • 2.860.0010
    • The 860 KF Thermoprep is designed for thermal sample preparation in Karl Fischer titration.Numerous substances cannot be analysed by direct Karl Fischer titration as they are not soluble, react with the Karl Fischer reagent or release their water only very slowly or not until heated to high temperatures. Using tightly sealed sample vials, the sample is inserted in the oven. The samples can be subsequently analysed by any volumetric or coulometric KF titrator.
    • <p>The 860 KF Thermoprep is designed for thermal sample preparation in Karl Fischer titration.</p><p>Numerous substances cannot be analysed by direct Karl Fischer titration as they are not soluble, react with the Karl Fischer reagent or release their water only very slowly or not until heated to high temperatures. Using tightly sealed sample vials, the sample is inserted in the oven. The samples can be subsequently analysed by any volumetric or coulometric KF titrator.</p>
    • PCS
    • 1
    • Reagent Replacement Solvent Module stopper
    • 6.1446.220
    • Stopper for reagent replacement in a coulometric titration cell with a Solvent Module.
    • <p>Stopper for reagent replacement in a coulometric titration cell with a Solvent Module.</p>
    • PCS
    • 1