Prezentare generală a caracteristicilor

Intelligent, combined pH electrode with integrated memory chip for storing sensor data for all non-aqueous acid/base titrations.
The glass membrane is optimized for poorly conducting solutions, and thanks to the flexible ground-joint diaphragm, the electrode is well suited for contaminated samples. This electrode can be used with non-aqueous reference electrolytes (lithium chloride or tetraethylammonium bromide). Storage in the respective reference electrolyte.
iTrodes can be connected to Titrando, Ti-Touch, or 913/914 meters.

Specificații tehnice

Shaft materialGlass
Measuring range (theoretical)0...14
Measuring unitpH
Temperature range, long-term (°C)0...70
Temperature range, short-term (°C)0...70
pH range0...14
Max. installation length (mm)113
Shaft diameter top (mm)12
Shaft diameter bottom (mm)12
Min. immersion depth (mm)30
Electrode plug-in headMetrohm plug-in head K
Indicator electrode shapeSphere
Membrane glass typeT
Membrane resistance40...150
Electrode zero point (mV)0...100
Electrode slope>0.90
DiaphragmGround-joint diaphragm
Reference electrolyte typeLiCl(sat) in ethanol
Electrolyte flow rate (μl/h) at 10 cm water column3...50
Reference systemLL system
Resistance (kOhm)<250
This field is required.
    • Sleeve with SGJ 14/12 mm
    • 6.1236.050
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • PCS
    • 1
    • Storage vessel 
    • 6.2008.040
    • Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
    • <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
    • PCS
    • 1
    • Sleeve with SGJ 14/12 mm
    • 6.1236.050
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • PCS
    • 1
    • Storage vessel 
    • 6.2008.040
    • Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
    • <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
    • PCS
    • 1
    • 854 iConnect
    • 2.854.0010
    • The 854 iConnect – Electrode cable and measuring amplifier for intelligent "iTrodes" electrodes (cable length 150 cm).
    • <p>The 854 iConnect – Electrode cable and measuring amplifier for intelligent "iTrodes" electrodes (cable length 150 cm).</p>
    • PCS
    • 1
    • TEABr 0.4 mol/L in ethylene glycol (250 mL)
    • 6.2320.000
    • Electrolyte solution TEABr (tetraethylammonium bromide in ethylene glycol), c(TEABr) = 0.4 mol/L
    • Electrolyte solution TEABr (tetraethylammonium bromide in ethylene glycol), c(TEABr) = 0.4 mol/L
    • PCS
    • 1