Solvotrode easyClean (fixed cable 1.2 m)

Solvotrode easyClean (fixed cable 1.2 m)

6.0229.010

Solvotrode easyClean (fixed cable 1.2 m)

en

6.0229.010

Prezentare generală a caracteristicilor

Combined pH electrode with flexible easyClean diaphragm and fixed cable (1.2 m) for all non-aqueous acid/base titrations.
The glass membrane is optimized for poorly conducting solutions, and thanks to the easy-to-clean easyClean diaphragm, the electrode is also well suited for heavily contaminated samples, such as used oil.
This electrode can be used with non-aqueous reference electrolytes (lithium chloride or tetraethylammonium bromide). Storage in the respective reference electrolyte.

The Solvotrode easyClean is also available under the article number 6.0229.020 with a fixed cable length of 2.0 m.

Specificații tehnice

Shaft materialGlass
Measuring unitpH
Temperature range, long-term (°C)0 ... 70
Temperature range, short-term (°C)0 ... 70
pH range0...14
Max. installation length (mm)125
SGJ sleeveflexible ground-joint sleeve
Shaft diameter top (mm)12
Shaft diameter bottom (mm)12
Min. immersion depth (mm)20
Electrode plug-in headFixed cable with plug F
Indicator electrode shapeSphere
Membrane glass typeT
Membrane resistance40...150
Electrode zero point (mV)0...100
Electrode slope>0.90
DiaphragmeasyClean
Reference electrolyte typeLiCl(sat) in ethanol
Electrolyte flow rate (μl/h) at 10 cm water column3...50
Reference systemLL system
Resistance (kOhm)< 250
This field is required.
    • Sleeve with SGJ 14/12 mm
    • 6.1236.050
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • PCS
    • 1
    • Storage vessel 
    • 6.2008.040
    • Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
    • <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
    • PCS
    • 1
    • Sleeve with SGJ 14/12 mm
    • 6.1236.050
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • PCS
    • 1
    • Storage vessel 
    • 6.2008.040
    • Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
    • <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
    • PCS
    • 1
    • OMNIS adapter cable
    • 6.02109.000
    • This adapter cable comprising socket F to plug P is suitable for use as a fixed cable (e.g. Optrode or Solvotrode easyClean) connecting a sensor without temperature sensor to the OMNIS analog measuring module.
    • <p>This adapter cable comprising socket F to plug P is suitable for use as a fixed cable (e.g. Optrode or Solvotrode easyClean) connecting a sensor without temperature sensor to the OMNIS analog measuring module.</p>
    • PCS
    • 1
    • TEABr 0.4 mol/L in ethylene glycol (250 mL)
    • 6.2320.000
    • Electrolyte solution TEABr (tetraethylammonium bromide in ethylene glycol), c(TEABr) = 0.4 mol/L
    • Electrolyte solution TEABr (tetraethylammonium bromide in ethylene glycol), c(TEABr) = 0.4 mol/L
    • PCS
    • 1