Conductivity measuring cell c = 1.6 cm-1 with Pt1000 (fixed cable, 2.0 m)
6.00930.140
Conductivity measuring cell c = 1.6 cm-1 with Pt1000 (fixed cable, 2.0 m)
en
6.00930.140
Prezentare generală a caracteristicilor
3-conductor conductivity measuring cell with cell constant c = 1.6 cm-1 (guide value), with integrated Pt1000 temperature sensor and with fixed cable (2.0 m) for connecting to the OMNIS Measuring Module Conductivity.
This sensor is suitable for automated measurements of high conductivities (0.1 to 1000 mS/cm), e.g., in:
- Sea water
- Flush water
- Physiological solutions
Specificații tehnice
| Shaft material | Glass |
|---|---|
| Measuring range (theoretical) | 0.1...1000 |
| Measuring unit | mS/cm |
| Temperature range, long-term (°C) | 5...70 |
| Temperature range, short-term (°C) | 5...70 |
| Max. installation length (mm) | 125 |
| SGJ sleeve | Flexible ground-joint sleeve |
| Shaft diameter top (mm) | 12 |
| Shaft diameter bottom (mm) | 12 |
| Min. immersion depth (mm) | 40 |
| Electrode plug-in head | Fixed cable, plug N |
| Temperature sensor | Pt1000 |
| Type | 3-ring, Pt |
| Cell constant, guide value (1/cm) | 1.6 |
-
- Sleeve with SGJ 14/12 mm
- 6.1236.050
- Sleeve with SGJ 14/12 mm, polyethylene.
- Sleeve with SGJ 14/12 mm, polyethylene.
- PCS
- 1
- Storage vessel
- 6.2008.040
- Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
- <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
- PCS
- 1
-
- Sleeve with SGJ 14/12 mm
- 6.1236.050
- Sleeve with SGJ 14/12 mm, polyethylene.
- Sleeve with SGJ 14/12 mm, polyethylene.
- PCS
- 1
- Storage vessel
- 6.2008.040
- Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
- <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
- PCS
- 1
-
- Measuring module conductivity
- 6.02101.020
- Measurement channel for one OMNIS Titrator or Titration Module for the connection of conductivity measuring cells.
- <p>Measurement channel for one OMNIS Titrator or Titration Module for the connection of conductivity measuring cells.</p>
- PCS
- 1
- KCl ion standard 250 mL
- 6.2301.060
- KCl ion standard (c(ion) = 0.1000 +/-0.0005 mol/L), can also be used as standard solution for conductometry 12.87 mS/cm (25 °C).
- <p>KCl ion standard (c(ion) = 0.1000 +/-0.0005 mol/L), can also be used as standard solution for conductometry 12.87 mS/cm (25 °C).</p>
- PCS