You have been redirected to your local version of the requested page
Ag Titrode 

Ag Titrode 

6.00430.100

Ag Titrode 

en

6.00430.100

Prezentare generală a caracteristicilor

Combined silver ring electrode with a pH glass membrane as reference electrode.
This maintenance-free electrode is suitable for precipitation titrations when the pH value remains constant (titrant silver nitrate), for example of:
 

  • chloride, bromide, iodide
  • sulfides
  • hydrogen sulfide
  • mercaptans
  • cyanides
     

This electrode is stored in distilled water.

Depending on the application, we recommend using an Ag Titrode with a coating (AgBr, AgCl or Ag2S coating), which can be ordered accordingly.

Specificații tehnice

Shaft materialGlass
Measuring range (theoretical)-2000...2000
Measuring unitmV
Temperature range, long-term (°C)0...80
Temperature range, short-term (°C)0...80
pH range0...14
Max. installation length (mm)125
SGJ sleeveflexible
Shaft diameter top (mm)12
Shaft diameter bottom (mm)6
Min. immersion depth (mm)20
Electrode plug-in headMetrohm plug-in head G
Indicator electrode typeAg
Indicator electrode shapeRing
Reference systempH
This field is required.
    • Sleeve with SGJ 14/12 mm
    • 6.1236.050
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • PCS
    • 1
    • Storage vessel 
    • 6.2008.040
    • Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
    • <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
    • PCS
    • 1
    • Sleeve with SGJ 14/12 mm
    • 6.1236.050
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • PCS
    • 1
    • Storage vessel 
    • 6.2008.040
    • Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
    • <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
    • PCS
    • 1
    • Electrode cable plug-in head G / plug P, 0.55 m
    • 6.02104.000
    • Cable for connecting an analog electrode (plug-in head G) to an analog measuring module from OMNIS.
    • <p>Cable for connecting an analog electrode (plug-in head G) to an analog measuring module from OMNIS.</p>
    • PCS
    • 1
    • Electrode cable plug-in head G / plug P, 1.5 m
    • 6.02104.010
    • Cable for connecting an analog electrode (plug-in head G) to an analog measuring module from OMNIS.
    • <p>Cable for connecting an analog electrode (plug-in head G) to an analog measuring module from OMNIS.</p>
    • PCS
    • 1
    • Electrode cable / 1 m / F
    • 6.2104.020
    • For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
    • For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
    • PCS
    • 1